• Title/Summary/Keyword: 3-Dimensional Measurement

Search Result 1,256, Processing Time 0.034 seconds

Assessing Safety Requirements Based on KANO Model (KANO 모형 기반 안전요구사항 평가)

  • Sejung Lee;Seongrok Chang;Yongyoon Suh
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.3
    • /
    • pp.9-15
    • /
    • 2023
  • As the first step of risk management, risk identification is inevitable to understand the degree of work safety. However, the safety requirements can be divided in necessary factors and additional factors. Thus, we propose a safety requirements assessment model using Kano model derived from Herzberg's two-factor theory, classifying safety requirements into ideal elements and must-be elements. The Kano model is usually applied to evaluate customer satisfaction divided into three major requirements in the fields of product development and marketing: attractive, must-be, and one-dimensional requirements. Among them, attractive requirement and must-be requirement are matched with ideal element and must-be element for safety requirement classification, respectively. The ideal element is defined as preventive safety elements to make systems more safe and the must-be element is referred to as fatal elements to be essentially eliminated in systems. Also, coefficients of safety measurement and safety prevention are developed to classify different class of safety requirements. The positioning map is finally visualized in terms of both coefficients to compare the different features. Consequently, the proposed model enables safety managers to make a decision between safety measurement and prevention.

Development of a muon detector based on a plastic scintillator and WLS fibers to be used for muon tomography system

  • Chanwoo Park;Kyu Bom Kim;Min Kyu Baek;In-soo Kang;Seongyeon Lee;Yoon Soo Chung;Heejun Chung;Yong Hyun Chung
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.1009-1014
    • /
    • 2023
  • Muon tomography is a useful method for monitoring special nuclear materials (SNMs) such as spent nuclear fuel inside dry cask storage. Multiple Coulomb scattering of muons can be used to provide information about the 3-dimensional structure and atomic number(Z) of the inner materials. Tomography using muons is less affected by the shielding material and less harmful to health than other measurement methods. We developed a muon detector for muon tomography, which consists of a plastic scintillator, 64 long wavelength-shifting (WLS) fibers attached to the top of the plastic scintillator, and silicon photomultipliers (SiPMs) connected to both ends of each WLS fiber. The muon detector can acquire X and Y positions simultaneously using a position determination algorithm. The design parameters of the muon detector were optimized using DETECT2000 and Geant4 simulations, and a muon detector prototype was built based on the results. Spatial resolution measurement was performed using simulations and experiments to evaluate the feasibility of the muon detector. The experimental results were in good agreement with the simulation results. The muon detector has been confirmed for use in a muon tomography system.

Development of Stereocopic-PIV and its Application to the Measurement of the Near Wake of a Circular Cylinder (Stereocopic-PIV 개발과 원주근접 후류 계측)

  • Doh, D.H.;Kim, D.H.;Cho, G.R.;Lee, W.J.;Pyun, Y.B.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.555-559
    • /
    • 2001
  • A new stereoscopic PIV is developed using two CCD cameras, stereoscopic photogrammetry, and a 3D-PTV principle. The wake of a circular cylinder is measured by the developed stereoscopic PIV technique. The B mode vortical structure of the wake over the Reynolds number 300 is clearly seen by the developed technique. The arrangement of the two cameras is based on angular position. The calibration of cameras and the pair-matching of the three-dimensional velocity vectors are based on 3D-PTV technique.

  • PDF

A Study on Building 3-D Object Recognition System Using the Orientation Information (방향정보를 이용한 3차원 물체 인식시스템의 구축에 관한 연구)

  • 박종훈;이상훈;최연성;최종수
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.5
    • /
    • pp.757-766
    • /
    • 1990
  • In this paper a new knowledge based vision system using orientation information on each surface of the 3-dimensional object is discussed. The measurement of the orientation information is performed by photometric stereo method. And then the obtained orientations are segmented using Gaussian curvature and mean curvature. A hierarchical knowledge base which is based on the characteristics, shape, area and length of the surface is built up, and then the knowledge based system infers by the condition interprete system (CIS). As the results, an easier and more accurate 3-D object recognition system is implemented, because it uses the characteristics and shapes as units of the surface in the recognition process.

  • PDF

A Study on the Determination of 3-Dimensional Position by Trilateration (삼변측량에 의한 3차원 위치결정에 관한 연구)

  • 박운용;이종출;김희규
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.7 no.1
    • /
    • pp.1-9
    • /
    • 1989
  • Up to date, the ditermination of three dimentional position is performed sperately by horizontal and vertical adjustment. The purpose of this study is to determine simultaneously three dimentional coordinates of one unknown point by measuring only three slope distances from one unknown point to three fixed points. In this study, the adjustment problem for measurement values inclading redundancy is solved by observation equation and condition equation, and also the characteristic of these two analysis methods is studied and investigated.

  • PDF

EVALUATION OF FAST NEUTRON FLUENCE FOR KORI UNIT 3 PRESSURE VESSEL

  • Yoo, Choon-Sung;Kim, Byoung-Chul;Chang, Kee-Ok;Lee, Sam-Lai;Park, Jong-Ho
    • Nuclear Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.665-674
    • /
    • 2006
  • Three-dimensional neutron flux and fluence of Kori Unit 3 were evaluated using the synthesis technique described in Regulatory Guide 1.190 for all reactor geometry. For this purpose DORT neutron transport calculations from Cycle 1 to Cycle 15 were performed using BUGLE-96 cross-section library. The calculated flux and fluence were validated by comparing the calculated reaction rates to the measurement data from the dosimetry sensor set of the $5^{th}$ surveillance capsule withdrawn at the end of cycle 15 of Kori Unit 3. And then the best estimation of the neutron exposures for the reactor vessel beltline region was performed using the least square evaluation. These results can be used in the assessment of the state of embrittlement of Kori Unit 3 pressure vessel.

Evaluation of Focal Bone Mineral Density Using Three-dimensional Measurement of Hounsfield Units in the Proximal Humerus

  • Moon, Young Lae;Jung, Sung;Park, Sang Ha;Choi, Gwi Youn
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.2
    • /
    • pp.86-90
    • /
    • 2015
  • Background: Although there are several methods for evaluating bone quality, Hounsfield units (HU), a standardized computed tomography (CT) attenuation coefficient, provide a useful tool for estimating focal bone mineral density (BMD). The aim of this study is to investigate the HU for evaluating the degree of osteoporosis in greater tuberosity with regard to anchor positioning. Methods: Forty patients diagnosed as normal on shoulder CT were included and categorized according to age and gender. Axially sectioned CT images were processed to 3-dimensional models containing information about bone quality using Mimics (14.11 platform v14.1.1.1 Materialise). Three-dimensional anchors were simulated and positioned according to 6 regions of interest (ROI) in the greater tuberosity classified using Tingart's system. Mean HU of intra-anchor volumes in the 6 regions was measured. Results: A significant decrease in HU was observed with increasing age (p=0.0001) and menopause (p<0.001). A significant difference in HU was found between male and female groups with males showing the higher values (p=0.0001). HU of proximal areas of ROI was higher than those of distal areas (p<0.005). However, although mean HU of distal posterior ROI showed the lowest values, no statistically significant difference was found between anterior, middle, and posterior regions (p=0.087). Conclusions: Mean HU of ROIs provides a tool for preoperative assessment of focal BMD, which is a factor of suture anchor stability and can be used to aid decision-making regarding secure anchor positioning for rotator cuff repair. Our data support that the most secure point is the proximal regions of ROI.

Experimental Validation of Topology Design Optimization Considering Lamination Direction of Three-dimensional Printing (3D 프린팅 적층 방향을 고려한 위상최적설계의 실험적 검증)

  • Park, Hee-Man;Lee, Gyu-Bin;Kim, Jin-san;Seon, Chae-Rim;Yoon, Minho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.3
    • /
    • pp.191-196
    • /
    • 2022
  • In this study, the anisotropic mechanical property of fused deposition modeling three-dimensional (3D) printing based on lamination direction was verified by a tensile test. Moreover, the property was applied to solid isotropic materials with penalization-based topology optimization. The case of the lower control arm, one of the automotive suspension components, was considered as a benchmark problem. The optimal topological results varied depending on the external load and anisotropic property. Based on these results, two test specimens were fabricated by varying the lamination direction of 3D printing; a tensile test utilizing 3D non-contact strain gauge was also conducted. The measured strain was compared with that obtained by computer-aided engineering response analysis. Quantitatively, the measurement and analysis results are found to have good agreement. The effectiveness of topology optimization considering the lamination direction of 3D printing was confirmed by the experimental result.

Reliability Study of Three-Dimensional Motion Analysis Program for Wrist and Finger Joint Range of Motion Measurement (손목 · 손가락 관절가동범위 측정에 관한 3차원 동작분석 프로그램의 신뢰도 연구)

  • Park, Sun Ha;Park, Ji-Hyuk;Kim, Jong Bae;Jung, Young Jin;Lee, Joo Hyun;Park, Hae Yean
    • Therapeutic Science for Rehabilitation
    • /
    • v.12 no.1
    • /
    • pp.79-92
    • /
    • 2023
  • Objective : This study aimed to assess the reliability of a three-dimensional (3D) motion analysis program for measuring the range of motion (ROM) of wrist and finger joints. Methods : The study recruited 50 people who had no restrictions on wrist and finger movements, understood the purpose of this study, and agreed to participate. Using a goniometer and a 3D motion analysis program, a total of 11 wrist and finger ROM were measured once each. To measure the reliability of the 3D motion analysis program, the degree of agreement and inconsistency of the measured values were compared. Results : Analysis of the degree of agreement of the measured values revealed that 38 out of 44 items showed a very high degree of agreement. Regarding analysis of inconsistency in the measured values, inconsistencies were found in three items. Conclusion : The results of this study confirmed that the ROM of the joint could be measured using the 3D motion analysis program applied in this study. In addition, it might be expected that the 3D motion analysis program would be used in various clinical fields owing to the advantages of measurement convenience and accuracy.

Accuracy and Reliability of The Spine-Pelvis Monitor to Record Three-Dimensional Characteristics of The Spine-Pelvic Motion

  • Kim, Jung-Yong;Yoon, Kyung-Chae;Min, Seung-Nam;Yoon, Sang-Young
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.2
    • /
    • pp.345-352
    • /
    • 2012
  • Objective: The aim of this study is to evaluate the accuracy and reliability of Spine-Pelvis Monitor(SPM) that was developed to measure 3-dimensional motion of spine and pelvis using tilt sensor and gyro sensor. Background: The main cause of low back pain is very much associated with the task using the low back and pelvis, but no measurement technique can quantify the both spine and pelvis. Method: For testing the SPM, 125 angles from three anatomical planes were measured three times in order to evaluate the accuracy and reliability. The accuracy of SPM in measuring dynamic motion was evaluated using digital motion analysis system. The motion pattern captured by two measuring methods was compared with each other. In result, the percentage error and Cronbach coefficient alpha were calculated to evaluate the accuracy and reliability. Results: The percentage error was 0.35% in flexion-extension on sagittal plane, 0.43% in lateral bending on coronal plane, and 0.40% in twisting on transverse plane. The Cronbach coefficient alpha was 1.00, 0.99 and 0.99 in sagittal, coronal and transvers plane, respectively. Conclusion: The SPM showed less than 1% error for static measurement, and showed reasonably similar pattern with the digital motion system. Application: The results of this study showed that the SPM can be the measuring method of spine pelvis motion that enhances the kinematic analysis of low back dynamics.