• Title/Summary/Keyword: 3-D surface

Search Result 5,578, Processing Time 0.033 seconds

3D Overhead Modeling Using Depth Sensor

  • Song, Eungyeol;Lee, Sangyoun
    • Journal of International Society for Simulation Surgery
    • /
    • v.1 no.2
    • /
    • pp.83-86
    • /
    • 2014
  • Purpose This paper was purposed to suggest the method to produce the supportive helmet (head correction) for the infants who are suffering from plagiocephaly and to evaluate the level of transformation through 3D model. Method Either of CT or X-ray restored images has been used in making the supportive helmet (Head correction) in general, but these methods of measuring have problems in cost and safety. 3D surface measurement technology was suggested to solve such matters. Results It was to design the transformed model of the head within 0.7cm in average by scanning the surface of head and performing 3D restoration with marching cube and the changing rate of the head was compared in numerical data with 3D model. Conclusion The suggested methods displayed the better performance than the conventional method in respect of the speed and cost.

2D Pattern Development of Body Surface from 3D Human Scan Data Using Standing and Cycling Postures (3D 스캔을 이용한 사이클 동작 전후 체표 변화 고찰 및 2D 전개 패턴의 비교)

  • Jeong, Yeonhee;Lee, Yejin
    • Korean Journal of Human Ecology
    • /
    • v.21 no.5
    • /
    • pp.975-988
    • /
    • 2012
  • Although the pattern development for tight-fitting clothing has been carried out using 3D data on humans, the pattern development using 3D scan data obtained for various postures still remains an interesting subject. In this study, we have developed the 2D pattern using the 3D human body reflecting standing and cycling postures. The 3D scan data of a subject was obtained using Cyberware. 2C-AN program(Triangle simplification and the Runge-Kutta method) was used in the system to reduce the 3D scan data points and to make segmented triangular patches in a plane from 3D data. As results, surface distance and area of each body part of standing and cycling postures were also provided for the future application of the functional clothing construction. The area of center piece on the front (c.front) decreased by $106.45cm^2$(-13.08%) and that of lateral piece(s.back) on the back increased by $144.96cm^2$(18.69%) in the patterns of cycling posture. The girth of neck and waist for the cycling posture increased by 0.88cm (3.92%) and 1.56cm(4.40%) respectively, and the that of thigh decreased by 1.01cm(-2.24%). The differences between the area in the 2D pattern obtained from the 3D scan data and that in the 3D scan surface data for standing and cycling postures were very small($-10.34cm^2$(-0.32%) and $-44.33cm^2$(-1.32%)).

A Study of the Electrical Properties of the Buccal Area using Facial Surface Electromyography

  • Choi, Yoo Min;Kim, Jong Uk;Kim, Lak Hyung;Yook, Tae Han
    • Journal of Acupuncture Research
    • /
    • v.34 no.2
    • /
    • pp.75-82
    • /
    • 2017
  • Objectives : The purpose of this study was to determine the electrical properties of the buccal area using facial surface electromyography (sEMG). Methods : This research was conducted on 44 healthy participants irrespective of their sex. Surface electrodes were attached to the midpoints of three imaginary lines connecting ST4 (Dicang) to ST6 (Jiache), ST4 to SI18 (Quanliao), and ST4 to the center point of SI18 and ST6. Then, the participants were trained in the movement that included a comprehensive action of buccal area. While the participants were performing the motion, sEMG values ($E_1$, $E_2$, $E_3$) and the distance change of the three imaginary lines ($D_1$, $D_2$, $D_3$) were measured. The data were statistically analyzed using SPSS ver. 22.0. Results : Significant differences were observed in the distance changes ($D_1$>$D_3$, $D_2$>$D_3$) and sEMG values ($E_1$<$E_2$<$E_3$). Moreover, there were positive correlations between $D_1$ and $E_1$, $D_2$ and $E_2$. Conclusion : We suggest that the measurement at ST4 to the center point of ST6 and SI18 with this motion would be adequate to check the electrical characteristics of the buccal area.

Construction of 3D Geometric Surface Model from Laminated CT Images for the Pubis (치골 부위의 CT 적층 영상을 활용한 3D 기하학적 곡면 모델로의 가공)

  • Hwang, Ho-Jin;Mun, Du-Hwan;Hwang, Jin-Sang
    • Korean Journal of Computational Design and Engineering
    • /
    • v.15 no.3
    • /
    • pp.234-242
    • /
    • 2010
  • 3D CAD technology has been extended to a medical area including dental clinic beyond industrial design. The 2D images obtained by CT(Computerized Tomography) and MRI(Magnetic Resonance Imaging) are not intuitive, and thus the volume rendering technique, which transforms 2D data into 3D anatomic information, has been in practical use. This paper has focused on a method and its implementation for forming 3D geometric surface model from laminated CT images of the pubis. The implemented system could support a dental clinic to observe and examine the status of a patient's pubis before implant surgery. The supplement of 3D implant model would help dental surgeons settle operation plans more safely and confidently. It also would be utilized with teaching materials for a practice and training.

A study on surface settlement characteristics according to the cohesive soil depth through laboratory model tests (실내모형시험을 통한 점성토 지반의 토피고에 따른 지표침하 특성연구)

  • Kim, Young-Joon;Im, Che-Geun;Kang, Se-Gu;Lee, Yong-Joo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.6
    • /
    • pp.507-520
    • /
    • 2014
  • In this study, the surface displacement was investigated according to the various depth of cover when the tunnel excavation equipment was used in a clay soil. For this the laboratory scaled model test was carried out using the soil sample similar to the in-situ conditions. We carried out four tests according to tunnel depth(1.5D, 2.0D, 2.5D, 3.0D). The distribution of impact due to tunnelling was quantitatively analyzed in the three-dimension by measuring the surface displacement. In addition, the pattern of surface displacements was figured out.

Visualization and Localization of Fusion Image Using VRML for Three-dimensional Modeling of Epileptic Seizure Focus (VRML을 이용한 융합 영상에서 간질환자 발작 진원지의 3차원적 가시화와 위치 측정 구현)

  • 이상호;김동현;유선국;정해조;윤미진;손혜경;강원석;이종두;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.34-42
    • /
    • 2003
  • In medical imaging, three-dimensional (3D) display using Virtual Reality Modeling Language (VRML) as a portable file format can give intuitive information more efficiently on the World Wide Web (WWW). The web-based 3D visualization of functional images combined with anatomical images has not studied much in systematic ways. The goal of this study was to achieve a simultaneous observation of 3D anatomic and functional models with planar images on the WWW, providing their locational information in 3D space with a measuring implement using VRML. MRI and ictal-interictal SPECT images were obtained from one epileptic patient. Subtraction ictal SPECT co-registered to MRI (SISCOM) was performed to improve identification of a seizure focus. SISCOM image volumes were held by thresholds above one standard deviation (1-SD) and two standard deviations (2-SD). SISCOM foci and boundaries of gray matter, white matter, and cerebrospinal fluid (CSF) in the MRI volume were segmented and rendered to VRML polygonal surfaces by marching cube algorithm. Line profiles of x and y-axis that represent real lengths on an image were acquired and their maximum lengths were the same as 211.67 mm. The real size vs. the rendered VRML surface size was approximately the ratio of 1 to 605.9. A VRML measuring tool was made and merged with previous VRML surfaces. User interface tools were embedded with Java Script routines to display MRI planar images as cross sections of 3D surface models and to set transparencies of 3D surface models. When transparencies of 3D surface models were properly controlled, a fused display of the brain geometry with 3D distributions of focal activated regions provided intuitively spatial correlations among three 3D surface models. The epileptic seizure focus was in the right temporal lobe of the brain. The real position of the seizure focus could be verified by the VRML measuring tool and the anatomy corresponding to the seizure focus could be confirmed by MRI planar images crossing 3D surface models. The VRML application developed in this study may have several advantages. Firstly, 3D fused display and control of anatomic and functional image were achieved on the m. Secondly, the vector analysis of a 3D surface model was defined by the VRML measuring tool based on the real size. Finally, the anatomy corresponding to the seizure focus was intuitively detected by correlations with MRI images. Our web based visualization of 3-D fusion image and its localization will be a help to online research and education in diagnostic radiology, therapeutic radiology, and surgery applications.

  • PDF

3D Elastic Contact Analysis of Sharkskin Surface Pattern (상어 표피 형상의 3차원 탄성접촉해석)

  • Kim, Tae Wan
    • Tribology and Lubricants
    • /
    • v.28 no.6
    • /
    • pp.297-302
    • /
    • 2012
  • We conducted 3D elastic contact analysis of a sharkskin surface pattern for the characteristic assessment of biomimetic shark skin structure pattern for engineering applications. Rough sharkskin surfaces of similar size with real shark skin scales are generated numerically. Under the assumption of the contact of a plate on the generated sharkskin surface, contact performances such as contact pressure, real contact area, and surface separation are evaluated.

A Compact Metamaterial Chip Antenna with Ground Coupling Structure for Bluetooth Application (Ground Coupling 구조를 이용한 초소형 Metamaterial Bluetooth 칩 안테나)

  • Park, Young-Hwan;Lee, Kang-Hee;Ji, Jeong-Keun;Ryu, Ji-Woong;Kim, Gi-Ho;Seong, Won-Mo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.9
    • /
    • pp.930-935
    • /
    • 2009
  • This paper describes a miniaturezed metamaterial BT chip antenna for mobile devices. The size of the proposed antenna is $3.0\;mm(W){\times}2.0\;mm(L){\times}1.2\;mm(H)$. And it is fabricated by chip type. The zeroth-order resonant properties are analyzed by magnitude and phase distributions of the surface current using surface current scanning system. The antenna offers omni-directional radiation patterns and measured 3D average gain is over - 1.7 dBi.

$VC^2$ Chord-Length Spline Surface Using Hermite Interpolant (허미트 보간을 이용한 곡률 연속 현길이 스플라인 곡면)

  • Jun, C.S.;Ju, S.Y.;Jeon, M.G.
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.20 no.1
    • /
    • pp.87-98
    • /
    • 1994
  • This paper describes a method of constructing VC2 Chord-length spline surface from semi-evenly spaced 3D point array. The suface uses Hermite interpolant as Ferguson surface, and it is an extention of chord-length spline curve to surface The proposed surface may be widely used in interpolating smoothly 3D point data obtaind by measurement or engineering design.

  • PDF

Heat Transfer from each surface for a 3-D Thermally Asymmetric Rectangular Fin

  • Kang, Hyung Suk
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.4 no.2
    • /
    • pp.153-163
    • /
    • 2000
  • The non-dimensional convective heat losses from each surface are investigated as a function of the non-dimensional fin length, width and the ratio of upper surface Biot number to bottom surface Biot number (Bi2/Bi1) using the three-dimensional separation of variables method. Heat loss ratio in view of each surface with the variation of Bi2/Bi1 is presented. The variation of the non-dimensioal temperare profile along the fin center line for a thermally asymmetric conditions is also presented.

  • PDF