• Title/Summary/Keyword: 3-D position

Search Result 2,275, Processing Time 0.033 seconds

Real-time Reefer Container Monitoring System based on IoT (IoT 기반 실시간 냉장컨테이너 상태 모니터링 시스템)

  • Moon, Young-Sik;Jung, Jun-Woo;Choi, Sung-Pill;Kim, Tae-Hoon;Lee, Byung-Ha;Kim, Jae-Joong;Choi, Hyung-Lim
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.3
    • /
    • pp.629-635
    • /
    • 2015
  • In this paper, we propose the reefer container monitoring system that not only monitors internal temperature, humidity of reefer container but also tracks the real-time location using GPS. It consists of a tag of information of situation using 433MHz RF transmitter(communication), GPS to track the real-time location and a device using WCDMA/GSM communication to transmit information to the server. We tested by applying the proposed system in reefer containers with yellow melons, melons transported from Korea to Singapore to track the location and check the temperature and the humidity. The result of this test is that there is a temperature difference around 1.7 degree depending on the position of inside of container and maintains the humidity stably about 97%. If we apply this proposed system to agricultural marketing, it is possible to get the time that fruits start to decay and minimize the loss of fruits by decaying during shipping.

Three-dimensional Texture Coordinate Coding Using Texture Image Rearrangement (텍스처 영상 재배열을 이용한 삼차원 텍스처 좌표 부호화)

  • Kim, Sung-Yeol;Ho, Yo-Sung
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.6 s.312
    • /
    • pp.36-45
    • /
    • 2006
  • Three-dimensional (3-D) texture coordinates mean the position information of torture segments that are mapped into polygons in a 3-D mesh model. In order to compress texture coordinates, previous works reused the same linear predictor that had already been employed to code geometry data. However, the previous approaches could not carry out linear prediction efficiently since texture coordinates were discontinuous along a coding order. Especially, discontinuities of texture coordinates became more serious in the 3-D mesh model including a non-atlas texture. In this paper, we propose a new scheme to code 3-D texture coordinates using as a texture image rearrangement. The proposed coding scheme first extracts texture segments from a texture. Then, we rearrange the texture segments consecutively along the coding order, and apply a linear prediction to compress texture coordinates. Since the proposed scheme minimizes discontinuities of texture coordinates, we can improve coding efficiency of texture coordinates. Experiment results show that the proposed scheme outperforms the MPEG-4 3DMC standard in terms of coding efficiency.

THE EVALUATION OF THE POSITIONAL CHANGE OF THE MANDIBULAR CONDYLE AFTER BILATERAL SAGITTAL SPLIT RAMUS OSTEOTOMY USING THREE DIMENSIONAL COMPUTED TOMOGRAPHY IN SKELETAL CLASS III PATIENTS (골격성 3급 부정교합 환자에서 하악지시상분할골절단술 후 3D CT 영상을 이용한 하악과두 위치변화 분석)

  • Jang, Jung-Rok;Choi, Guen-Ho;Park, Young-Jun;Kim, Bang-Sin;Yu, Min-Gi;Kook, Min-Suk;Park, Hong-Ju;Ryu, Sun-Youl;Oh, Hee-Kyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.5
    • /
    • pp.316-323
    • /
    • 2009
  • Purpose: This study was performed to evaluate three-dimensional positional change of the condyle using 3D CT after bilateral sagittal split ramus osteotomy (BSSRO) in skeletal class III patients. Patients and methods: Nine patients who underwent BSSRO for mandibular set-back in skeletal class III malocclusion without facial asymmetry were examined. Miniplates were used for the fixation after BSSRO. 3-D CT was taken before, immediately after, and 6 months after undergoing BSSRO. After creating 3D-CT images using V-works $4.0^{TM}$ program, axial plane, coronal plane, & sagittal plane were configured. Three dimensional positional change, from each plane to the condyle, of the nine patients was measured before, immediately after, and 6 months after undergoing BSSRO. Results: 1. The mean value of mandibular set-back for nine mandibular prognathism patients was 7.36 mm (${\pm}\;2.42\;mm$). 2. In the axial view, condyle is rotated inward immediately after BSSRO (p < 0.05), comparing with preoperative but outward 6 months after BSSRO comparing with postoperative (p < 0.05). 3. In the axial view, condyle is moved laterally immediately after BSSRO (p < 0.05), comparing with preoperative but regressed 6 months after BSSRO comparing with preoperative (p > 0.05). 4. In the frontal & coronal view, there is changed immediately after and 6 months after BSSRO, comparing with preoperative but no statistical difference. Conclusion: These results indicate that three-dimensional positional change of the condyle in skeletal class III patients is observed lateral displacement & inward rotation immediate after BSSRO, but the condyle in 6 months after BSSRO tends to regress to preoperative position.

Development of Geocoding and Reverse Geocoding Method Implemented for Street-based Addresses in Korea (우리나라 도로명주소를 활용한 지오코딩 및 역 지오코딩 기법 개발)

  • Seok, Sangmuk;Lee, Jiyeong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.34 no.1
    • /
    • pp.33-42
    • /
    • 2016
  • In Korea, the address-point matching technique has been used to provide geocoding services. In fact, this technique brings the high positional accuracy. However, the quality of geocoding result can be limited, since it is significantly affected by data quality. Also, it cannot be used for the 3D address geocoding and the reverse geocoding. In order to alleviate issues, the paper has implemeted proposed geocoding methods, based on street-based addresses matching technique developed by US census bureau, for street-based addresses in Korea. Those proposed geocoding methods are illustrated in two ways; (1) street address-matching method, which of being used for not only 2D addresses representing a single building but also 3D addresses representing indoor space or underground building, and (2) reverse geocoding method, whichas converting a location point to a readable address. The result of street-based address geocoding shows 82.63% match rates, while the result of reverse geocoding shows 98.5% match rates within approximately 1.7(m) the average position error. According to the results, we could conclude that the proposed geocoding techniques enable to provide the LBS(Location Based Service). To develop the geocoding methods, the study has perfoermed by ignoring the parsing algorithms for address standardization as well as the several areas with unusual addresses, such as sub-urban areas or subordinate areas to the roads, etc. In the future, we are planning the improved geocoding methods for considering these cases.

Development of a split beam transducer for measuring fish size distribution (어체 크기의 자동 식별을 위한 split beam 음향 변환기의 재발)

  • 이대재;신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.3
    • /
    • pp.196-213
    • /
    • 2001
  • A split beam ultrasonic transducer operating at a frequency of 70 kHz to use in the fish sizing echo sounder was developed and the acoustic radiation characteristics were experimentally analyzed. The amplitude shading method utilizing the properties of the Chebyshev polynomials was used to obtain side lobe levels below -20 dB and to optimize the relationship between main beam width and side lobe level of the transducer, and the amplitude shading coefficient to each of the elements was achieved by changing the amplitude contribution of elements with 4 weighting transformers embodied in the planar array transducer assembly. The planar array split beam transducer assembly was composed of 36 piezoelectric ceramics (NEPEC N-21, Tokin) of rod type of 10 mm in diameter and 18.7 mm in length of 70 kHz arranged in the rectangular configuration, and the 4 electrical inputs were supplied to the beamformer. A series of impedance measurements were conducted to check the uniformity of the individual quadrants, and also in the configurations of reception and transmission, resonant frequency, and the transmitting and receiving characteristics were measured in the water tank and analyzed, respectively. The results obtained are summarized as follows : 1. Average resonant and antiresonant frequencies of electrical impedance for four quadrants of the split beam transducer in water were 69.8 kHz and 83.0 kHz, respectively. Average electrical impedance for each individual transducer quadrant was 49.2$\Omega$ at resonant frequency and 704.7$\Omega$ at antiresonant frequency. 2. The resonance peak in the transmitting voltage response (TVR) for four quadrants of the split beam transducer was observed all at 70.0 kHz and the value of TVR was all about 165.5 dB re 1 $\mu$Pa/V at 1 m at 70.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The resonance peak in the receiving sensitivity (SRT) for four combined quadrants (quad LU+LL, quad RU+RL, quad LU+RU, quad LL+RL) of the split beam transducer was observed all at 75.0 kHz and the value of SRT was all about -177.7 dB re 1 V/$\mu$Pa at 75.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The sum beam transmitting voltage response and receiving senstivity was 175.0 dB re 1$\mu$Pa/V at 1 m at 75.0 kHz with bandwidth of 10.0 kHz, respectively. 3. The sum beam of split beam transducer was approximately circular with a half beam angle of $9.0^\circ$ at -3 dB points all in both axis of the horizontal plane and the vertical plane. The first measured side lobe levels for the sum beam of split beam transducer were -19.7 dB at $22^\circ$ and -19.4 dB at $-26^\circ$ in the horizontal plane, respectively and -20.1 dB at $22^\circ$ and -22.0 dB at $-26^\circ$ in the vertical plane, respectively. 4. The developed split beam transducer was tested to estimate the angular position of the target in the beam through split beam phase measurements, and the beam pattern loss for target strength corrections was measured and analyzed.

  • PDF

The Investigation Image-guided Radiation Therapy of Bladder Cancer Patients (방광암 환자의 영상유도 방사선치료에 관한 고찰)

  • Bae, Seong-Soo;Bae, Sun-Myoung;Kim, Jin-San;Kang, Tae-Young;Back, Geum-Mun;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.1
    • /
    • pp.39-43
    • /
    • 2012
  • Purpose: In hospital image-guided radiation therapy in patients with bladder cancer to enhance the reproducibility of the appropriate amount, depending on the patient's condition, and image-guided injection of saline system (On-Board Imager system, OBI, VARIAN, USA) three of the Cone-Beam CT dimensional matching (3D-3D matching) to be the treatment. In this study, the treatment of patients with bladder cancer at Cone-Beam CT image obtained through the analysis of the bones based matching and matching based on the bladder to learn about the differences, the bladder's volume change injected saline solution by looking at the bladder for the treatment of patients with a more appropriate image matching is to assess how the discussion. Materials and Methods: At our hospital from January 2009 to April 2010 admitted for radiation therapy patients, 7 patients with bladder cancer using a Folly catheter of residual urine in the bladder after removing the amount determined according to individual patient enough to inject saline CT-Sim was designed after the treatment plan. After that, using OBI before treatment to confirm position with Cone-Beam CT scan was physician in charge of matching was performed in all patients. CBCT images using a total of 45 bones, bladder, based on image matching and image matching based on the difference were analyzed. In addition, changes in bladder volume of Eclipse (version 8.0, VARIAN, USA) persuaded through. Results: Bones, one based image matching based on the bladder and re-matching the X axis is the difference between the average $3{\pm}2mm$, Y axis, $1.8{\pm}1.3mm$, Z-axis travel distance is $2.3{\pm}1.7mm$ and the overall $4.8{\pm}2.0mm$, respectively. The volume of the bladder compared to the baseline showed a difference of $4.03{\pm}3.97%$. Conclusion: Anatomical location and nature of the bladder due to internal movement of the bones, even after matching with the image of the bladder occurred in different locations. In addition, the volume of saline-filled bladder showed up the difference between the 4.03 percent, but matched in both images to be included in the planned volumes were able to confirm. Thus, after injection of saline into the bladder base by providing a more accurate image matching will be able to conduct therapy.

  • PDF

Two- and Three-dimensional Analysis on the Bubble Flow Characteristics Using CPFD Simulation

  • Lim, Jong Hun;Lee, Dong Hyun
    • Korean Chemical Engineering Research
    • /
    • v.55 no.5
    • /
    • pp.698-703
    • /
    • 2017
  • Bubble flow characteristics in fluidized beds were analyzed by CPFD simulation. A fluidized bed, which had the size of $0.3m-ID{\times}2.4m-high$, was modeled by commercial CPFD $Barracuda^{(R)}$. Properties of bed material were $d_p=150{\mu}m$, ${\rho}_p=2,330kg/m^3$, and $U_{mf}=0.02m/s$. Gas was uniformly distributed and the range of superficial gas velocity was 0.07 to 0.16 m/s. Two other geometries were modeled. The first was a three-dimensional model, and the other was a two-dimensional model of $0.01m{\times}0.3m{\times}2.4m$. Bubble size and rising velocity were simulated by axial and radial position according to superficial gas velocity. In the case of three-dimensional model, simulated bubble rising velocity was different from correlations, because there was zigzag motion in bubble flow, and bubble detection was duplicated. To exclude zigzag motion of bubble flow, bubble rising velocity was simulated in the two-dimensional model and compared to the result from three-dimensional model.

Kinematic Analysis of Service Movement In Each Position of Soft Tennis (포지션별 정구 플랫서비스의 운동학적분석)

  • Kim, Hun-Soo
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.1
    • /
    • pp.221-231
    • /
    • 2002
  • The purpose of this study was to clarify the differences in service patterns of a forward and backward soft tennis players using 3D motion analyzer. Subjects were 4 forward players of $24.0\pm5.23$yrs and 4 backward players of $23.5\pm1.73$yrs. The results were as following: 1. There was no difference among each positions on swinging-time. The longest racket swinging-time was in the phase of takeback, the second one was in follow-through. The shortest one was in the phase of forward-swing so called force production phase, which had an influence on ball's velocity. 2. The racket speed on impact was 16.3m/s in forward subject and 19.53m/s in backward subject, when each velocity of balls was 44.6m/s, 52.9m/s. Although there was no significant difference along by positions, backward subject showed faster result. 3. The maximum speed of each performance was reached before the impact, and the speed at impact along by positions did not show any significant difference. The summation of velocity was measured in good order as following; hip, shoulder, elbow, wrist, top of racket. 4. In the angular velocity of all examine except one, the angular velocity of forearm was bigger than the one of racket top although there was no statistically significant difference between forward and backward subject. 5. The service grip of the forward players was shorter than that of backward players.

Self-efficacy, Nursing Organizational Culture and Emotional Labor in Clinical Nurses (임상간호사의 자아효능감, 간호조직문화 및 감정노동)

  • Kang, Moonhee;Kwon, Myoungjin;Youn, Soonyoung
    • Korean Journal of Occupational Health Nursing
    • /
    • v.21 no.3
    • /
    • pp.266-273
    • /
    • 2012
  • Purpose: The objective of this study was to investigate the relationship among self-efficacy, nursing organizational culture and the emotional labor in clinical nurses. Methods: The subjects of this study were the clinical nurses working at 3 general hospitals in D city. The self-reported questionnaires were administered to 293 clinical nurses and data were analyzed with SPSS/WIN 19.0. Results: The levels of self-efficacy, nursing organizational culture and emotional labor of the subjects were revealed moderate to high. Significant explanatory variables of the degrees of self-efficacy included age, career of work and job satisfaction and nursing organizational culture included position, nursing method and job satisfaction and emotional labor included education, number of patient and job satisfaction. Correlations between self-efficacy and emotional labor and nursing organizational culture and emotional labor were negative while self-efficacy and nursing organizational culture were positive. Conclusion: The findings suggested the intervention program in order to improve job performance and job satisfaction, develop effective nursing organizational culture and reduce role conflicts among clinical nurses.

An Improved GoGOP Structure for Multi-view Video Coding in H.264/AVC (H.264/AVC에서 다시점 비디오 부호화를 위한 향상된 GoGOP 구조)

  • Shin, Kwang-Mu;Lee, Seo-Young;Kim, Sung-Min;Chung, Ki-Dong
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.14 no.3
    • /
    • pp.271-275
    • /
    • 2008
  • Corresponding recent continuous development of multimedia technology with improved desire of using various contents, a new realistic feeling media technology is being created. Of them all, multi-view video is being researched actively as foundation technology of 3D TV, free-view point video etc. But encoding time and bit-rate are increased as view numbers are increased. In this paper we propose improved GoGOP structure to enhance the coding efficiency of multi-view video by applying methods which are using techniques such as Key frame position adjustment, dynamically changing the number of I frame and B frame. As experimental results, technique proposed in this paper reduces bit-rate having similar PSNR value compared with Anchor structure.