• Title/Summary/Keyword: 3-D motion analysis system

Search Result 295, Processing Time 0.035 seconds

Vector form intrinsic finite-element analysis of static and dynamic behavior of deep-sea flexible pipe

  • Wu, Han;Zeng, Xiaohui;Xiao, Jianyu;Yu, Yang;Dai, Xin;Yu, Jianxing
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.376-386
    • /
    • 2020
  • The aim of this study was to develop a new efficient strategy that uses the Vector form Intrinsic Finite-element (VFIFE) method to conduct the static and dynamic analyses of marine pipes. Nonlinear problems, such as large displacement, small strain, and contact and collision, can be analyzed using a unified calculation process in the VFIFE method according to the fundamental theories of point value description, path element, and reverse motion. This method enables analysis without the need to integrate the stiffness matrix of the structure, because only motion equations of particles established according to Newton's second law are required. These characteristics of the VFIFE facilitate the modeling and computation efficiencies in analyzing the nonlinear dynamic problem of flexible pipe with large deflections. In this study, a three-dimensional (3-D) dynamical model based on 3-D beam element was established according to the VFIFE method. The deep-sea flexible pipe was described by a set of spatial mass particles linked by 3-D beam element. The motion and configuration of the pipe are determined by these spatial particles. Based on this model, a simulation procedure to predict the 3-D dynamical behavior of flexible pipe was developed and verified. It was found that the spatial configuration and static internal force of the mining pipe can be obtained by calculating the stationary state of pipe motion. Using this simulation procedure, an analysis was conducted on the static and dynamic behaviors of the flexible mining pipe based on a 1000-m sea trial system. The results of the analysis proved that the VFIFE method can be efficiently applied to the static and dynamic analyses of marine pipes.

Accuracy and Consistency of Three-Dimensional Motion Analysis System (3차원 동작분석 시스템의 정밀도와 측정 일관성)

  • Park, Young-Hoon;Youm, Chang-Hong;Seo, Kook-Woong
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.2
    • /
    • pp.83-92
    • /
    • 2005
  • Computer-assisted motional analysis is a popular method in biomechanical studies. Validation of the specific system and its measurement are fundamental to its application in the areas. Because the accuracy and consistency of a particular system provide the researchers with critical information to assist in making judgements regarding the degree to which inferences can be drawn from measurement data. The purpose of this study was to assess the accuracy and consistency of the Kwon3D motion analysis system. Validation parameters were five lengths from eight landmarkers in combination with the DLT reconstruction error values, digitizing monitor resolutions, and numbers of control points. With the best setting, Kwon3D's estimations of 260cm, 200cm, 140cm, 100cm, and 20cm were $260.33{\pm}.688cm$, $199.98{\pm}.625cm$, $139.89{\pm}.537cm$, $99.75{\pm}.466cm$, $20.08{\pm}.114$, respectively. There was no significant DLT error value difference between two monitor resolutions, but 0.27cm significant difference in 260cm estimation. There were significant differences in 260cm and 200cm estimations between with 33-control-point DLT error and with 17-control-point DLT error, but no in 140cm, 100cm, and 20cm estimations. Test-retest results showed that Kwon3D measurements were highly consistent with reliability coefficients alpha of .9263 and above.

Biomechanical Analysis and Evaluation Technology Using Human Multi-Body Dynamic Model (인체 다물체 동역학 모델을 이용한 생체역학 분석 및 평가 기술)

  • Kim, Yoon-Hyuk;Shin, June-Ho;Khurelbaatar, Tsolmonbaatar
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.494-499
    • /
    • 2011
  • This paper presents the biomechanical analysis and evaluation technology of musculoskeletal system by multi-body human dynamic model and 3-D motion capture data. First, medical image based geometric model and material properties of tissue were used to develop the human dynamic model and 3-D motion capture data based motion analysis techniques were develop to quantify the in-vivo joint kinematics, joint moment, joint force, and muscle force. Walking and push-up motion was investigated using the developed model. The present model and technologies would be useful to apply the biomechanical analysis and evaluation of human activities.

3D Depth Information Extraction Algorithm Based on Motion Estimation in Monocular Video Sequence (단안 영상 시퀸스에서 움직임 추정 기반의 3차원 깊이 정보 추출 알고리즘)

  • Park, Jun-Ho;Jeon, Dae-Seong;Yun, Yeong-U
    • The KIPS Transactions:PartB
    • /
    • v.8B no.5
    • /
    • pp.549-556
    • /
    • 2001
  • The general problems of recovering 3D for 2D imagery require the depth information for each picture element form focus. The manual creation of those 3D models is consuming time and cost expensive. The goal in this paper is to simplify the depth estimation algorithm that extracts the depth information of every region from monocular image sequence with camera translation to implement 3D video in realtime. The paper is based on the property that the motion of every point within image which taken from camera translation depends on the depth information. Full-search motion estimation based on block matching algorithm is exploited at first step and ten, motion vectors are compensated for the effect by camera rotation and zooming. We have introduced the algorithm that estimates motion of object by analysis of monocular motion picture and also calculates the averages of frame depth and relative depth of region to the average depth. Simulation results show that the depth of region belongs to a near object or a distant object is in accord with relative depth that human visual system recognizes.

  • PDF

A Study on Walking Movements for Skirt Patterns with 3D Motion Analysis System (3차원 동작분석장치를 이름한 하지동작 연구)

  • Kim, Jung-Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.9
    • /
    • pp.1603-1613
    • /
    • 2001
  • 본 연구는 동작분석장치를 이용하여 하지동작분석을 시도함으로서 실제 동작 시 적응 할 수 있는 의복설계를 위한 기초 자료로서 하지부 실루엣 변화의 특성을 밝히고자 하였다. 대퇴돌기점을 기준으로 본 하지동작의 진행방향 이동과 상향 방향이동을 살펴보았는데 보행유형에 따라 여유량이 특히 요구되는 부위가 각기 다르며, 부위별 필요 여유 량도 각기 다르다는 것을 알 수 있었으며 , 이러한 보행유형 별 스커트 실루엣의 특징은 기능복 설계 시 고려되어야 하겠다. 평지보행 시는 발목부위가 전면방향보다 후면방향으로 이동의 범위가 크므로 트임이나 주름이 뒷면에 있는 것이 적합하고, 계단승강이나 버스승강의 경우 무릎전면에 여유량이 필요하므로 주름이나 트임을 앞쪽에 주는 것이 바람직하며 그 길이는 대퇴돌기점 높이정도에서 시작하여야 하고 무릎아래에 있는 앞트임은 하지동작에 도움이 되지 않음을 알 수 있었다.

  • PDF

Development of Motion Capture System (동작 획득 시스템의 개발)

  • U, Jeong-Jae;Choe, Hyeong-Sik;Kim, Yeong-Sik;Jeon, Dae-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.10
    • /
    • pp.139-146
    • /
    • 2002
  • We developed a motion capture system to utilize informations on the human walking motion. The system is composed of the mechanical and electronic devices to obtain the joint angle data and the software to analyze the obtained data and to transform the data into the input for a biped walking robot. The mechanical system is composed of a pair of links with 3 revolute joints, on which potentiometers are attached on joint axes to sense rotation angles. Analog signals from potentiometers are transformed into the digital data through the low pass filter and the A/D converter, and then which are stored at the computer. We analyzed the walking characteristics by applying FFT to the digital data, and then performed a 3-D computer simulation using the data. Finally, We apply the processed data to a biped walking robot.

The method to estimate 3-D coordinates of lower trunk muscles using orientation angles during a motion (몸통 운동시 지향각(Orientation angles)을 이용한 허리 근육의 3차원 위치 좌표 추정 기법)

  • Lim, Young-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.1
    • /
    • pp.125-133
    • /
    • 2002
  • The purpose of this study was to develop a method for estimating 3-D coordinates of lower trunk muscles using orientation angles during a motion. Traditional 3-D motion analysis system with DLT technique was used to track down the locations of eight reference markers which were attached on the back of the subject. In order to estimate the orientations of individual lumbar vertebrae and musculoskeletal parameters of the lower trunk muscle, the rotation matrix of the middle trunk reference frame relative to the lower trunk reference frame was determined and the angular locations of individual lumbar vertebrae were estimated by partitioning the orientation angles (Cardan angles) that represent the relative angles between the rotations of the middle and lower trunks. When the orientation angles of individual intervertebral joints were known at a given instant, the instantaneous coordinates of the origin and insertion for all selected muscles relative to the L5 local reference frame were obtained by applying the transformation matrix to the original coordinates which were relative to a local reference frame (S1, L4, L3, L2, or L1) in a rotation sequence about the Z-, X- and Y-axes. The multiplication of transformation matrices was performed to estimate the geometry and kinematics of all selected muscles. The time histories of the 3-D coordinates of the origin and insertion of all selected muscles relative to the center of the L4-L5 motion segment were determined for each trial.

Analysis of Motion and Pressure for Circular Friction Massage (전문수기마사지 동작 중 원형강찰법에 대한 동작 및 가압력 분석)

  • Kim, Y.H.;Ryu, J.S.;Son, J.S.;Hwang, S.H.;Sohn, R.H.;Cha, I.H.;Song, J.H.;Song, S.J.
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.6
    • /
    • pp.487-493
    • /
    • 2010
  • In this study, the circular friction massage technique was performed on the trapezius, the levator scapulae, and the deltoid muscles to collect the information on massage pressures and positions, and thus to utilize it in professional massage system design. Massage motion was measured with the 3-D motion capture system and finger pressures were simultaneously obtained with grip sensors. Massage motions, pressure patterns, and pressure times were different on each muscle, and the motion trajectory was similar to the ellipsoidal shape. The trapezius had higher pressure, longer massage time, and larger impulse than other muscles. These results could be useful to design a massage system based on biomechanical analysis. In order to improve massage effect, it is also strongly recommended that the tip of the system be similar with that of a human thumb in shape and material.

A Study on the Motion of a Single Point Moored Ship in Irregular Waves (불규칙파중 1점계류 선바의 거동해석에 관한 연구)

  • Lee, Seung-Keon;Jo, Hyo-Jae;Kang, Dong-Hoon
    • Journal of Navigation and Port Research
    • /
    • v.27 no.1
    • /
    • pp.55-61
    • /
    • 2003
  • The maneuvering equations of motion are derived to express the motion of a ship. The wave forces in the time domain analysis are generated from the frequency transfer function calculated by 3-D source distribution method. The linear wave forces whose periods are equal to those of incident waves and the nonlinear wave forces that make long period drift forces are computed for the simulation. The consideration of irregular waves and nonlinear wave force effects on the slew motion are carried on the analyzing the motion of ship in the regular and irregular waves.

Effects of Hallux Valgus Orthoses on Ground Reaction Force Using 3D Motion Analysis in Individuals With Hallux Valgus Deformity

  • Kim, Yong-wook
    • Physical Therapy Korea
    • /
    • v.27 no.4
    • /
    • pp.227-232
    • /
    • 2020
  • Background: Hallux valgus (HV) is a foot deformity developed by mediolateral deviation of the first metatarsophalangeal joint. Although various foot-toe orthoses were used to correct the HV angle, verification of the effects of kinetics variables such as ground reaction force (GRF) through three-dimensional (3D) gait analysis according to the various type of orthoses for HV is insufficient. Objects: This study aimed to investigate the effect of soft and hard types of foot and toe orthoses to correct HV deformity on the GRF in individuals with HV using 3D motion analysis system during walking. Methods: Twenty-six subjects participated in the experiment. Participants had HV angle of more than 15° in both feet. Two force platforms were used to obtain 3D GRF data for both feet and a 3D motion capture system with six infrared cameras was used to measure exact stance phase point such as heel strike or toe off period. Total walk trials of each participant were 8 to 10, the walkway length was 6 m. Two-way repeated measures ANOVA was used to determine the effects of each orthosis condition on the various GRF values. Results: The late anteroposterior maximal force and a first vertical peak force of the GRF showed that the hard type orthosis condition significantly increased GRF compared to the other orthosis conditions (p < 0.05). Conclusion: There were significant effects in GRF values when wearing the hard type foot orthosis. However, the hard type foot orthosis was uncomfortable to wear during walking. Therefore, it is necessary to develop a new foot-toe orthosis that can compensate for these disadvantages.