An Electrical Resistivity Survey for the Characterization of Alluvial Layers at Groundwater Artificial Recharge Sites (지하수 인공함양 지역 충적층 특성 평가를 위한 전기비저항탐사)

  • Won, Byeongho;Shin, Jehyun;Hwang, Seho;Hamm, Se-Yeong
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.3
    • /
    • pp.154-162
    • /
    • 2013
  • Vertical electrical sounding and 2D electrical resistivity survey were applied for evaluating the characteristics of alluvial layers at a groundwater artificial recharge site. The fine particles in alluvial layer, main target layer of groundwater artificial recharge, may cause clogging phenomena. In this case, electrical resistivity method is an effective technique to verify the spatial distribution of low-resistivity layers, such as saturated silts and clays. On the other hand, much attention should be paid to interpret the resistivity data in unconsolidated layers, because thick clayey overburden sometimes produces a masking effect on underlying interbedded resistive sands and gravels. Considering these points, we designed 35 points arranged in a grid form for vertical electrical sounding and 10 lines for 2D electrical resistivity survey, and concentrated our effort on enhancing the vertical and horizontal resolution of resistivity images. According to the results, 15 meters thick layers consisting of sands and gravels are located in 30 meters below ground. And the spatial distribution of silts and clays are mapped, which may cause clogging. Consequently, this approach can contribute to design and determine the location and depth of injection and observation wells for groundwater artificial recharge.

A Study on Electrical Resistivity Geophysical Surveys of the Noen Landfill Site (전기비저항 탐사를 이용한 노은매립장 침출수 분포에 관한 연구)

  • Kim, Jun-Kyoung;Hong, Sang-Pyo;Kim, Kwang-Yul;Cho, Yong-Jin
    • Journal of Environmental Impact Assessment
    • /
    • v.13 no.5
    • /
    • pp.223-230
    • /
    • 2004
  • The electrical resistivity prospecting method with dipole-dipole array were applied in order to survey 3-D structure characteristics of the Noen landfill site. For the electrical resistivity prospecting, 3 line of measurements were established parallel to the main boundary of the Noen landfill site and additional 2 lines were also established perpendicular to the existing 3 lines for the effective investigation of the landfill site. The results showed that the uppermost layer of the landfill site is believed to be stabilized generally based on the characteristics of electrical resistivity distribution. Lowest layer was partially polluted by the leachate.

Detection of cavities in a karst area by means of a 3D electrical resistivity technique (3차원 전기비저항탐사에 의한 카르스트 지역에서의 공동탐지)

  • Park, Sam-Gyu;Kim, Chang-Ryol;Son, Jung-Sul;Yi, Myeong-Jong;Kim, Jung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.1
    • /
    • pp.27-32
    • /
    • 2009
  • In this study, we examined the applicability of a 3D electrical resistivity technique for the probing of underground cavities at a field test site in a karst area in Yongweol-ri, Muan-gun, in the south-western part of the Korean peninsula. At the test site, where the ground has subsided in the past, underground cavities are commonly found in the limestone bedrock, which is overlain with alluvial deposits. The limestone cavities at the test site are mostly filled with groundwater and clay; hence, they show levels of electrical resistivity that are significantly lower than those of the surrounding host bedrock. The results of this study demonstrate that the zones of low resistivity correspond to the zones of the cavities identified in the boreholes at the site, and that our 3D electrical resistivity survey is a very effective tool for detecting and mapping underground cavities in a karst area.

Application Techniques of 2D-Resistivity Structure for Estimation of Inferred Fracture Zone in Weathered Slope (풍화사면에서의 추정파쇄대 평가를 위한 2차원 전기비저항 구조도 적용 기법)

  • Kim, Jae-Hong;Park, Chal-Sook;Lee, Hyun-Jae;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.19 no.3
    • /
    • pp.323-330
    • /
    • 2009
  • Electrical resistivity survey is applied for estimation of inferred fault and fractured zone in civil engineering and environment field. While 15 m diameter and 3 lines tunnels are excavated. It is recognized that core stone and fractured zone is existed in the weathered slope of the entrance to a tunnel. To make confirmation geological characteristics, dipole-dipole electric resistivity survey was carried out in weathered slope of the entrance to a tunnel. Core stone distribution and fracture zone characteristics are estimated by reverse analysis and 2D-resistivity structure using FDM.

An Electrical Resistivity Survey for Leachate Investigation at a Solid Waste Landfill (폐기물 매립지 침출수 조사를 위한 전기비저항 탐사)

  • Lee, Keun-Soo;Cho, In-Ky;Mok, Jong-Koo;Kim, Jeong-Woo
    • Geophysics and Geophysical Exploration
    • /
    • v.19 no.2
    • /
    • pp.59-66
    • /
    • 2016
  • The electrical resistivity method is an effective geophysical tool to detect subsurface contamination because the contaminated zones show generally lower electrical resistivity. In this study, the electrical resistivity surveys were applied to a waste landfill site to image the subsurface structure around the landfill and to identify the contaminated zones. First, the dipole-dipole 2D resistivity surveys were conducted along the boundaries of landfill to define the developed contaminated zones. Then the crosshole resistivity tomography was applied to confirm the suspected contaminated zones at depth. The results of drilling and geochemical analysis of ground water supported that the low resistivity zones coincide well with the contaminated zones and the leachate pathways could be delineated effectively from the resistivity survey.

Structural-Health Evaluation for Core Zones of Fill Dams in Korea using Electrical Resistivity Survey and No Water Boring Method (전기비저항 탐사와 무수보링을 이용한 국내 필 댐 코어존의 건전성 평가)

  • Lee, Sangjong;Lim, Heuidae;Park, Dongsoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.8
    • /
    • pp.21-35
    • /
    • 2015
  • Electrical resistivity survey (2D and 3D) were employed for detection of possible weak zone of core zones of three central core earth-rockfill dams in Korea. In the 2D results, the core zones is lower resistivity zone with less than $50{\sim}400ohm{\cdot}m$, and the basement is relatively higher resistivity zone with over $1,000ohm{\cdot}m$. In the 3D results, especially, the weak zone with under $100ohm{\cdot}m$ was detected spatial distribution area in the dam. We also drilled boreholes to collect soil samples of core zones of each dam. Water was not used during boring, because water for rotary wash boring could cause structural damages in earth dams. We found that the soil samples of core zones from all of the boreholes correspond to CL (USCS), but we also found that the fluidized or water-saturated soil samples were found in lower resistivity zones. Therefore, the electrical resistivity survey and drilling method without water are a quick and efficient method for structural-health evaluation which is detection of possible weak zones in earth core rockfill dams.

Analysis of Environmental Hazard by the Leachate from Disposal Waste (매립장 침출수 환경 재해에 관한 연구)

  • Kim, Jun-Kyoung;Bae, Hyo-Jun;Choi, Oh-Soon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.3 no.4 s.11
    • /
    • pp.145-151
    • /
    • 2003
  • The domestic and the industry wastes which mainly come out of human life activities have been usually processed mainly by the incineration method and/or the method of reclamation. The method of reclamation, specially open dumping, has caused significant environmental pollution problems on the local or regional soil and groundwater system by leachate. Therefore, to investigate the 3-D structure characteristics of environmental pollution area is one of the hot subjects. We applied dipole-dipole method of electrical resistivity survey to investigate 3-D environmental contamination characteristics of the Noeun landfill area. For electrical resistivity survey, the line for measurements was established parallel to the main boundary of the Noeun landfill, for effective investigation of the whole landfill area. The result shows that the uppermost layer of the Noeun landfill is believed to be stabilized completely, based on the result of electrical resistivity values. However, the lowest layer of the Noeun landfill was partially polluted by leachate. Therefore, the electrical resistivity survey method is believed to be the one of the most effective methods to investigate three-dimensional distribution of leachate occurred in the lower part of landfill area.

Electrical Resistivity Imaging for Upper Layer of Shield TBM Tunnel Ceiling (쉴드 TBM터널 상부 지반 연약대 전기탐사)

  • Jung, Hyun-Key;Park, Chul-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.401-408
    • /
    • 2005
  • Recently shield TBM tunnellings are being applied to subway construction in Korean cities. Generally these kinds of tunnellings have the problems in the stability of ground such as subsidence because urban subway is constructed in the shallow depth. A sinkhole occurred on the road just above the tunnel during tunneling in Kwangju, so a survey for upper layer of the tunnel was needed. But conventional Ground Probing Radar can't be applicable due to the presence of steel-mesh screen in the shield segment, so no existent geophysical method is applicable in this site. Because the outer surface of each shield segment is electrically insulated, dipole-dipole resistivity method which is popular in engineering site investigation, was tried to this survey for the first time. Specially manufactured flexible ring-type electrodes were installed into the grouting holes at an interval of 2.4 m on the ceiling. The K-Ohm II system which has been developed by KIGAM and tested successfully in many sites, was used in this site. The system consists of 1000Volt-1Ampere constant-current transmitter, optically isolated 24 bit sigma-delta A/D conversion receiver - maximum 12 channel simultaneous measurements, and graphical automatic acquisition software for easy data quality check in real time. Borehole camera logging with circular white LED lighting was also done to investigate the state of the layer. Measured resistivity data lack of some stations due to failing opening lids of holes, shows general high-low trend well. The dipole-dipole resistivity inversion results discriminate (1) one approximately 4 meter diameter cavity (grouted but incompletely hardened, so low resistivity - less than $30{\Omega}m$), (2) weak zone (100-200${\Omega}m$), and (3) hard zone (high resistivity - more than 1000${\Omega}m$) very well for the distance of 320 meters. The 2-D inversion neglects slight absolute 3-D effect, but we can get satisfactory and useful information. Acquired resistivity section and video tapes by borehole camera logging will be reserved and reused if some problem occurs in this site in the future.

  • PDF

The Technical Solution for Various Array Methods in Resistivity Survey (전기비저항 탐사의 다양한 배열 방법에 대한 해석 기법)

  • Park, Chung-Hwa
    • The Journal of Engineering Geology
    • /
    • v.17 no.1 s.50
    • /
    • pp.49-55
    • /
    • 2007
  • Various away methods are required in the electrical resistivity survey in order to find anomalous zone reliably. Array methods are classified as several groups. Among these group, a curved survey along the fixed elevation is designed to increase the mobility of men and survey equipments at the rough terrain. Another method is performed at the survey using inclined, curved, and horizontal boreholes. A survey can also be conducted in an arbitrary location by measurements of potentials for a multi sources. The complex data acquired using various away methods are represented by a correct images reconstructed from the 3D inversion. The element division is applied to the region in which the boreholes are curved and inclined because of a spatial discrepancies between the coordinate of each electrode and the nodal point in a model. The resistivity images are obtained from a good agreement for the anomalous zones in open slope and in survey using an inclined borehole.

Electrical resistivity survey and interpretation considering excavation effects for the detection of loose ground in urban area

  • Seo Young Song;Bitnarae Kim;Ahyun Cho;Juyeon Jeong;Dongkweon Lee;Myung Jin Nam
    • Geomechanics and Engineering
    • /
    • v.35 no.2
    • /
    • pp.109-119
    • /
    • 2023
  • Ground subsidence in urban areas due to excessive development and degraded underground facilities is a serious problem. Geophysical surveys have been conducted to estimate the distribution and scale of cavities and subsidence. In this study, electrical resistivity tomography (ERT) was performed near an area of road subsidence in an urban area. The subsidence arose due to groundwater leakage that carried soil into a neighboring excavation site. The ERT survey line was located between the main subsidence area and an excavation site. Because ERT data are affected by rapid topographic changes and surrounding structures, the influence of the excavation site on the data was analyzed through field-scale numerical modeling. The effect of an excavation should be considered when interpreting ERT data because it can lead to wrong anomalous results. A method for performing 2D inversion after correcting resistivity data for the effect of the excavation site was proposed. This method was initially tested using a field-scale numerical model that included the excavation site and subsurface anomaly, which was a loosened zone, and was then applied to field data. In addition, ERT data were interpreted using an existing in-house 3D algorithm, which considered the effect of excavation sites. The inversion results demonstrated that conductive anomalies in the loosened zone were greater compared to the inversion that did not consider the effects of excavation.