• 제목/요약/키워드: 3-D conformal treatment

검색결과 104건 처리시간 0.028초

직장암 치료 시 치료계획에 따른 선량평가 연구 (A study of the plan dosimetic evaluation on the rectal cancer treatment)

  • 정현학;안범석;김대일;이양훈;이제희
    • 대한방사선치료학회지
    • /
    • 제28권2호
    • /
    • pp.171-178
    • /
    • 2016
  • 목 적 : 직장암 방사선 치료 시 대퇴골두의 선량을 최소화하기 위해, 보편적인 치료방법인 3문 입체조형치료계획(3D Conformal radiation therapy)과 5문 입체조형치료계획 그리고 용적변조방사선치료(Volumetric Modulated Arc Therapy, 이하 VMAT) 계획의 유용성을 비교, 평가하고자 한다. 대상 및 방법 : 본원에서 21EX(Varian Medical Systems, USA)를 이용하여 치료 받은 직장암 환자 10명을 대상으로 3문, 5문 입체조형치료계획과 VMAT 전산화치료계획을 각각 세우고 이에 대한 선량분포를 비교분석하였다. 전산화 치료계획은 Eclipse(Ver 10.0.42, Varian, USA)를 이용하였으며, 선량계산을 위해 PRO3(Progressive Resolution Optimizer 10.0.28), AAA(Anisotropic Analytic Algorithm Ver 10.0.28) 알고리즘을 사용하였다. 3문 치료계획은 6MV POST field 와 15MV LT, RT field를 갠트리 각도 $0^{\circ}$, $270^{\circ}$, $90^{\circ}$로 구성하였고, 5문 치료계획은 6MV POST field와 15MV RAO, RPO, LAO, LPO field를 갠트리 각도 $0^{\circ}$, $95^{\circ}$, $45^{\circ}$, $315^{\circ}$, $265^{\circ}$ 로 환자 체표면을 감싸는 형태로 구성하였다. VMAT 치료계획은 갠트리 회전반경이 $360^{\circ}$인 1개의 ARC를 이용하여 수립하였다. 처방선량은 30회에 걸쳐 직장에 총 선량이 54Gy가 되도록 하였다. VMAT 치료계획시 최적화(Optimization) 과정에서 나타나는 선량 차이의 무작위성을 최소화하기 위하여 2회의 최적화와 선량계산과정을 거쳤으며 처방선량의 100%가 표적용적의 95%를 포함할 수 있도록 Plan normalization을 조절하였다. 각 치료 계획의 Total MU, 대퇴골두와 acetabular fossa의 최대선량, PTV의 H.I. (Homogeneity Index), C.I.(Conformity Index)를 평가 지표로 설정하였고, 전자영상유도장치를 이용하여 임상 적용 가능 여부 확인을 위한 IMRT verification Q.A. (Gamma test)를 실시하였다. 결 과 : Rt. femoral head 최대선량은 3문, 5문, VMAT 치료계획 순으로 평균 53.08 Gy, 50.27 Gy, 30.92 Gy를 나타냈다. 마찬가지로 Lt. femoral head 에서도 같은 순으로 평균 53.68 Gy, 51.01 Gy, 평균 29.23 Gy를 나타냈다. Rt. Aceta fossa 의 최대선량은 3문, 5문, VMAT 치료계획 순으로 평균 54.86 Gy, 52.40 Gy, 30.37 Gy의 값을 보였다. Lt. Aceta fossa에서 또한 같은 순으로 평균 54.90 Gy, 52.77 Gy, 평균 31.79 Gy를 나타내어, both femoral head 와 aceta fossa의 최대선량이 3문, 5문, VMAT 치료계획 순으로 높았다. PTV에 대한 H.I.는 모두 서로 비슷한 결과를 나타냈고, C.I.는 3문, 5문, VMAT 치료계획 순으로 평균 1.64, 1.48, 평균 0.99로 VMAT 치료계획이 가장 낮은 것으로 나타났다. Total MU는 VMAT 치료계획이 3문과 5문 치료계획에 비해 각각 평균 124.4MU, 299MU 더 많이 사용하는 것으로 나타났다. VMAT 치료계획에 대한 IMRT verification Q.A. 결과 2mm / 2%, Gamma pass rate 90.0% 기준을 모두 초과하여 통과하였다. 결 론 : VMAT 치료계획은 3D 치료계획과 비교하여 대부분의 평가지표에서 우수한 것으로 나타났다. 특히 대퇴골두의 선량을 크게 감소 시켰으며, 저선량 영역에서는 소장이 받는 선량이 증가 하였으나 오히려 고선량 영역에서는 우수한 선량분포를 보였다. 하지만 VMAT을 지원하지 않는 장비와 치료계획 시 추가되는 Contouring, 그리고 정도관리에 관한 수고 등의 현실적인 제약 때문에 VMAT 치료계획을 선택하기 어려운 경우가 있을 수 있다. 5문 치료계획은 기존 3문 치료계획에 비해, 추가적인 문제에 구애받지 않고 대퇴골두의 선량을 줄일 수 있는 장점이 있다. 따라서 각 병원 상황에 맞게 치료계획을 선택하여 방사선 치료 효과를 높인다면, 직장암 환자의 효율적인 방사선치료 및 생존 기간의 연장뿐만 아니라 삶의 질 향상에도 도움이 될 것으로 판단한다.

  • PDF

식도암의 방사선치료에서 부분 각도에 의한 회전 치료를 이용한 조사체적의 감소 (Decrease of Irradiated Volume using Rotational Treatment by Avoidance Sector in Radiation Therapy for Esophageal Cancer)

  • 황철환;김성후;구재흥;손종기
    • 한국방사선학회논문지
    • /
    • 제12권5호
    • /
    • pp.583-592
    • /
    • 2018
  • 세기변조방사선치료와 입체적세기조절회전치료 시 조사체적과 선량 퍼짐 현상을 줄이기 위한 방법으로 조사 각도를 제한하는 부분 각도에 의한 회전치료 기능을 적용하여 표적체적과 주변 정상장기의 선량에 대해 입체조형방사선치료와 비교 분석하였다. 치료계획에 따른 표적체적의 선량분포는 통계적으로 유의한 차이를 확인할 수 없었으며, 폐의 5 Gy(V5) 체적에서 입체조형방사선치료 56.53%, 세기변조방사선치료 52.03%, 입체적세기조절회전치료 47.84%를 나타내어 유의한 차이를 나타내었다(CRT-IMRT p=0.035, CRT-VMAT p<0.001, IMRT-VMAT p<0.001). 10 Gy 체적(V10)에서는 입체조형방사선치료 35.12%, 세기변조방사선치료 34.04%, 입체적세기조절회전치료 33.28%를 보여, 입체조형방사선치료와 세기변조방사선치료(p=0.018), 입체적세기조절회전치료(p=0.035)에서 유의한 차이를 나타내었으나 20 Gy 체적(V20)에서는 유의한 선량 차이를 확인할 수 없었다. 심장의 평균선량과 20 Gy 체적은 치료계획에 따라 유의한 차이를 확인할 수 없었으나, 30, 40 Gy 체적은 입체적세기조절회전치료에서 37.16%, 22.46%를 나타내어 입체조형방사선치료와 비교에서 유의한 차이(p=0.028)를 보였다. 이와 같이 조사체적 감소에 따른 폐의 저 선량 체적(V5, V10)의 감소를 확인할 수 있었으며, 세기변조방사선치료와 입체적세기조절회전치료 시 조사 각도를 일부 제한함으로써 표적체적의 선량분포는 동일하게 유지함과 동시에 조사체적을 줄일 수 있었다. 이로 인해 폐의 선량 퍼짐 현상의 감소로부터 폐의 독성을 낮추는데 기여할 수 있을 것으로 사료된다.

유방암 방사선치료 시 최적의 방사선치료계획기법에 대한 고찰 (Study of the Optimize Radiotherapy Treatment Planning (RTP) Techniques in Patients with Early Breast Cancer; Inter-comparison of 2D and 3D (3DCRT, IMRT) Delivery Techniques)

  • 김영범;이상록;정세영;권영호
    • 대한방사선치료학회지
    • /
    • 제18권1호
    • /
    • pp.35-41
    • /
    • 2006
  • 목 적: 유방암 방사선치료 시 유방(breast), 흉벽(chest wall, 국부적 임파관(loco-regional lymphatics) 등에 적정한 선량을 조사하기 위하여 다양한 치료계획이 이루어지고 있는데 이에 따른 선량분포를 정성적, 정량적으로 분석하여 최적의 방사선치료계획 기법을 고찰해 보고자 한다. 대상 및 방법: 최적의 유방암 방사선치료계획 기법을 평가하기 위해 기존의 전통적인 방법(2D)과 전산화단층촬영 영상에서 각각 유방체적을 설정하여 3차원적으로 접근하는 방법인 입체조형치료방법(3-dimensional conformal radiotherapy, 3DCRT)과 강도조절방사선치료 방법(intensity modulated radiotherapy, IMRT)을 비교하였다. 이를 위해 인체팬텀에 유방(breast), 흉벽(chest wall, 국부적 임파관(loco-regional lymphatics), 폐(lung) 등의 관심영역을 정하여 표지한 후 전산화단층촬영(Volume, Siemens, USA)을 시행하였다. 획득한 전산화단층촬영영상을 이용하여 입체조형치료방법과 강도조절방사선치료 방법을 적용하여 방사선치료계획(XiO 5.2.1, FOCUS, USA)을 수립하였고, 이는 기존의 전통적인 방법과 비교하였다. 비교, 분석은 방사선치료계획기법(2D, 3DCRT, IMRT)에 따른 방사선량분포와 선량-체적 간 히스토그람(dose-volume histogram, DVH) 및 관심영역의 점 선량 등을 분석하여 시행하였고, 또한 시간-노동력에 따른 치료효율성에 대해서도 평가하였다. 결 과: 유방체적을 설정하여 3차원 방사선치료계획 기법을 사용한 경우가 기존의 전통적인 방법에 비해 종양 설정과 빔 방향 및 조사면 경계 확인 등에 유용하다는 것을 알 수 있었다. 결 론: 유방암 방사선치료 시 방사선치료계획 기법에 따른 정성적, 정량적 분석을 통해 최적의 방사선치료계획 기법을 제시할 수 있었다. 그러나 3차원 방사선치료계획 시 치료계획종양용적(planning target volume, PTV) 설정과 유방 고정의 어려움에 따른 환자자세 재현성에 대한 문제를 알 수 있어 이에 대한 추가 연구가 필요할 것이라 사료된다.

  • PDF

방사선치료 시 환자자세 확인을 위한 영상 분석 도구의 개발 (Development of a Verification Tool in Radiation Treatment Setup)

  • 조병철;강세권;한승희;박희철;박석원;오도훈;배훈식
    • 한국의학물리학회지:의학물리
    • /
    • 제14권3호
    • /
    • pp.196-202
    • /
    • 2003
  • 3차원 입체조형방사선치료(3D conformal radiation therapy; 3D-CRT) 및 세기조절방사선치료(intensity modulated radiation therapy; IMRT) 에서와 같은 정밀 방사선 치료기술이 보다 효과적으로 이루어지기 위해서는 환자자세 오차를 최소화해야 한다. 치료계획용적(PTV)을 정할 때 필요한 마진을 최대한 줄여 줌으로써 치료 병변에 선량을 집중시키고, 정상조직의 선량은 감소시킬 수 있게 되기 때문이다. 이러한 목적 하에 조사문 사진(portal film)을 치료계획시 얻은 기준 영상에 정합시켜 환자자세 오차를 정량적으로 분석할 수 있는 프로그램 도구를 개발하고자 하였다. 현재 본원에서 치료 위치 확인을 위해서는 치료 계획 시행 중에 얻은 모의치료 사진과 치료시 EC-L 필름(KODAK사, 미국)을 사용하여 찍은 조사문 사진을 주로 사용하고 있다. 이 외에도, 모의치료시 영상을 디지털 캡춰한 영상이나, 치료계획으로부터 얻은 디지털화재구성영상(digitally reconstructed radiograph; DRR)도 기준 영상으로 이용할 수 있도록 하였다. 프로그램 제작 툴로는 IDL5.4 (RSI사, 미국)를 사용하였다. 조사문사진의 가장 큰 단점인 영상 대조도를 증가시키기 위해, histogram-equalization, adaptive histogram equalization, 특히 CLAHE (contrast limited adaptive histogram equalization) 등의 영상처리 기능을 구현하였다. 영상 정합 방법으로는 기준 영상에 골반입구(pelvic inlet) 와 같은 위치에 윤곽선을 그리고, 이를 조사문 사진 상에 중첩시킨 다음, 조사문 사진의 동일 해부학적 위치에 일치되도록 이동하여 그 오차를 수치화하였다. 조사문 사진에 CLAHE 필터를 적용한 결과, 치료면 확인을 위해 이중 조사된 영역의 대조도를 월등히 향상시킬 수 있었다. 전후면과 측면 영상을 위 과정을 사용하여 정합시킴으로, 전후, 좌우, 상하 방향으로의 환자자세 차이를 정량화 할 수 있었다. 또한, CLAHE 영상처리 기법을 이용하여 조사문 사진의 화질을 현저하게 향상시킬 수 있음을 확인하였다. 또한 'view-box' 방식과 비교하여 치료 환자자세의 정확도를 수치화 시킴으로써 계통오차(systemic error)와 임의오차(random error) 등의 정량적 분석이 가능해졌다. 더 나아가 환자자세오차를 교정하는 프로토콜을 도입한다면, 보다 정확한 치료에 도움이 될 것으로 기대한다.

  • PDF

전립선암 방사선치료 시 광자극발광선량계를 이용한 광중성자선량 평가 (Evaluation of Photoneutron Dose for Prostate Cancer Radiation Therapy by Using Optically Stimulated Luminescence Dosimeter (OSLD))

  • 이주아;백금문;김연수;손순룡;최관우;유병규;정회원;정재홍;김기원;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권2호
    • /
    • pp.125-134
    • /
    • 2014
  • 본 연구는 전립선암의 방사선치료에 적용되는 치료기법별 세기조절방사선치료의 적절한 조사문수의 선택 및 광중성자 피폭을 고려한 방사선 치료계획 수립을 위한 기초자료를 제공하고자 하였다. 연구대상은 2013년 9월부터 2014년 1월까지 5개월 동안 전립선암으로 방사선치료를 받은 환자 10명을 대상으로 하였다. 그리고 3-dimensional conformal radiotherapy (3D-CRT), volumetric-modulated arc radiotherapy (VMAT), intensity modulated radiation therapy (IMRT) 5, 7, 9 조사문으로 각각 치료계획을 수립하였다. 기술통계와 분산분석으로 광중성자선량의 평균적 차이를 비교하였으며, 상관관계분석과 회귀분석으로 상관성 및 영향을 분석하였다. 연구 결과, 치료기법별로는 3D-CRT가 가장 낮았다. 또한 IMRT가 가장 높게 측정되었으며, 통계적으로 매우 유의하였다 (p<.01). 세기조절방사선치료 조사문수별 광중성자선량은 평균 $4.37{\pm}1.08mSv$였으며, 조사문수 간에 통계적으로 매우 유의한 차이를 보였다(p<.01). 그리고 조사문수와 광중성자선량은 상관계수가 0.570으로 나타나 통계적으로 매우 유의한 양의 상관관계를 보였다 (p<.01). 조사문수와 광중성자선량의 선형회귀분석 결과, 조사문수가 1단계 증가할 때마다 평균적으로 광중성자선량이 0.373배로 유의하게 증가하였다. 결론적으로 전립선암의 방사선치료에 빈번히 사용하고 있는 IMRT의 조사문수의 선택 및 광중성자 피폭선량 및 방사선 치료계획의 질적 수준 평가를 고려한 적절한 치료계획 선택에 있어 기초자료로 활용될 수 있으리라 기대된다.

Dose Planning Study of Target Volume Coverage with Intensity-Modulated Radiotherapy for Nasopharyngeal Carcinoma: Penang General Hospital Experience

  • Vincent Phua, Chee Ee;Tan, Boon Seang;Tan, Ai Lian;Eng, Kae Yann;Ng, Bong Seng;Ung, Ngie Min
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권4호
    • /
    • pp.2243-2248
    • /
    • 2013
  • Background: To compare the dosimetric coverage of target volumes and organs at risk in the radical treatment of nasopharyngeal carcinoma (NPC) between intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3DCRT). Materials and Methods: Data from 10 consecutive patients treated with IMRT from June-October 2011 in Penang General Hospital were collected retrospectively for analysis. For each patient, dose volume histograms were generated for both the IMRT and 3DCRT plans using a total dose of 70Gy. Comparison of the plans was accomplished by comparing the target volume coverage (5 measures) and sparing of organs at risk (17 organs) for each patient using both IMRT and 3DCRT. The means of each comparison target volume coverage measures and organs at risk measures were obtained and tested for statistical significance using the paired Student t-test. Results: All 5 measures for target volume coverage showed marked dosimetric superiority of IMRT over 3DCRT. V70 and V66.5 for PTV70 showed an absolute improvement of 39.3% and 24.1% respectively. V59.4 and V56.4 for PTV59.4 showed advantages of 18.4% and 16.4%. Moreover, the mean PTV70 dose revealed a 5.1 Gy higher dose with IMRT. Only 4 out of 17 organs at risk showed statistically significant difference in their means which were clinically meaningful between the IMRT and 3DCRT techniques. IMRT was superior in sparing the spinal cord (less 5.8Gy), V30 of right parotid (less 14.3%) and V30 of the left parotid (less 13.1%). The V55 of the left cochlea was lower with 3DCRT (less 44.3%). Conclusions: IMRT is superior to 3DCRT due to its dosimetric advantage in target volume coverage while delivering acceptable doses to organs at risk. A total dose of 70Gy with IMRT should be considered as a standard of care for radical treatment of NPC.

Importance of PET/CT Scan Use in Planning Radiation Therapy for Lymphoma

  • Milana, Mitric-Askovic;Marko, Erak;Miroslav, Latinovic;Tihomir, Dugandzija
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권5호
    • /
    • pp.2051-2054
    • /
    • 2015
  • Background: Radiation therapy is a key part of the combined modality treatment for Hodgkin's lymphoma (HL) and non-Hodgkin's lymphoma (NHL), which can achieve locoregional control of disease. The 3D-conformal radiation oncology can be extended-field (EFRT), involved-field (IFRT) and involved node (INRT). New techniques have resulted in a smaller radiation field and lower dose for critical organs such as lung heart and breast. Materials and Methods: In our research, we made a virtual simulation for one patient who was treated in four different radiotherapeutic techniques: mantle field (MFRT), EFRT, IFRT and INRT. After delineatiion we compared dose-volume histograms for each technique. The fusion of CT for planning radiotherapy with the initial PET/CT was made using Softver Xio 4.6 in the Focal program. The dose for all four techniques was 36Gy. Results: Our results support the use of PET/CT in radiation therapy planning. With IFRT and INRT, the burden on the organs at risk is less than with MFRT and EFRT. On the other hand, the dose distribution in the target volume is much better with the latter. Conclusions: The aim of modern radiotherapy of HL and NHL is to reduce the intensity of treatment and therefore PET/CT should be used to reduce and not increase the amount of tissue receiving radiation.

유방암 방사선치료에 있어 치료도중 및 분할치료 간 위치오차에 대한 전자포탈영상의 컴퓨터를 이용한 자동 분석 (Computer Assisted EPID Analysis of Breast Intrafractional and Interfractional Positioning Error)

  • ;;;;진호상;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제17권1호
    • /
    • pp.24-31
    • /
    • 2006
  • 유방암 환자의 방사선치료에 있어 치료도중(intrafractional) 및 분할 치료 간(intefractional)에 발생되는 오차를 측정하는 자동분석소프트웨어를 개발하였다. 오차 분석 결과는 3차원 입체조형 방사선치료를 임상에 적용하기에 앞서 적절한 치료계획용적(Planning Target Volume, PTV)을 설정하는 데 있어 매우 중요하다. 본 연구에서는 전자포탈영상장치(Electrical Portal imaging Device, EPID)로써 Portal Vision LC250 액체 충전형 이온화 검출기를 사용하였다(fast frame-averaging 모드, 초당 1.4 프레임, 256X256 픽셀). 12명의 환자에 대해 최소 7일 이상씩 영상을 획득하였다. 매 치료마다 평균 8 내지 9개의 영상을 각 빔에 대해 얻었다(분당 400 MU 선량률). 총 2,931 (720 측정을 포함하는)개의 영상을 정량적으로 분석할 수 있는 자동화 영상 분석 소프트웨어를 개발하였다. 이를 통해 호흡으로 인해 발생하는 치료도중 오차와 분할 치료간 발생하는 분할치료오차의 표준편차($\sigma$)들을 계산하였다. 신뢰 구간 95%로 임상표적체적(Clinical Target Volume, CTV)을 포함할 수 있는 PTV 마진은 $2\;(1.96\;{\sigma})$으로 계산되었다. 주로 호흡으로 인해 유발되는 치료도중오차를 보상하기 위해 필요한 PTV 마진은 2 mm에서 4 mm이었다. 반면에 분할 치료간 오차를 보상하기위해 필요한 PTV 마진은 7 mm에서 31 mm이었다. 12명의 환자에 대한 전체 평균오차는 17 mm이었다. 분할치료 간 오차는 호흡에 의해 유발되는 치료도중 오차에 비해 2배에서 15배까지 더 크게 나타났다. 유방암 치료에 있어 3차원 입체정형조사나 세기조절방사선치료(Intensity Modulated Radiation Therapy, IMRT)를 적용하기에 앞서 반드시 셋업 오차의 크기를 측정하여 PTV에 적절히 반영되어야 한다. 유방에 대한 3차원 입체정형조사나 세기조절방사선치료를 위해 반드시 필요한 것은 아니지만, 큰 PTV 마진을 줄여주기 위해서는 영상유도방사선치료(Image Guided Radiation Therapy, IGRT)가 매우 유용하게 이용될 수 있다. 전자포탈영상장치 들은 본 보고서에서 기술한 바와 같은 자동분석소프트웨어를 반드시 포함하여야 한다. 이를 통해 수많은 EPID 영상들을 자동화 처리하고 오차분석을 시행함으로써 각 병원의 임상적용 방법 및 환경에 따라 상이하게 나타날 수 있는 오차의 크기를 감안한 적절한 PTV마진을 구하는데 도움을 얻을 수 있다. 이러한 장치들은 또한 최소의 노력으로 환자 치료를 관찰할 수 있는 귀중한 정보를 제공해 준다.

  • PDF

가임기 여성의 방사선 치료 시 난소 선량 평가 (Evaluation of Ovary Dose of Childbearing age Woman with Breast cancer in Radiation therapy)

  • 박성준;이영철;김선명;김영범
    • 대한방사선치료학회지
    • /
    • 제33권
    • /
    • pp.145-153
    • /
    • 2021
  • 목 적: 본 연구에서는 가임기 여성의 유방암 방사선 치료 시 난소 선량에 대해 실험을 통하여 평가해보고자 한다. 치료기법에 따른 치료계획시스템에서 계산된 선량과 열형광선량계를 이용한 측정선량을 비교·분석하여 난소 선량을 평가하고 납(Pb) 앞치마의 사용유무에 따른 선량 분석을 통해 임상에서의 유용성을 알아보고자 한다. 대상 및 방법: 측정에는 Rando humanoid phantom을 이용하였고, 치료기법으로는 쐐기필터치료기법, 3차원 입체조형치료, 세기변조방사선치료를 사용하였다. CT simulator를 이용하여 얻은 Rando humanoid phantom 3D 영상의 우측 유방에 처방선량의 95%가 전달될 수 있도록 치료계획을 세웠고, TLD를 Rando hunmanoid phantom의 가상 표적의 표면 및 심부에 삽입하고 방사선을 조사하였다. 측정위치는 치료 중심점과 Rando humanoid phantom의 정중앙을 중심으로 반대쪽 유방으로 2cm 이동한 지점과 치료 중심축 및 하방으로 우측 유방의 경계면에서 5cm, 10cm, 12.5cm, 15cm, 17.5cm, 20cm, 우측 난소 위치의 표면과 중심점을 포함하여 총 9개 지점에서 측정하였다. 치료계획시스템의 선량 비교에서는 쐐기필터치료기법 2가지와 3차원 입체조형치료, 세기변조방사선치료 등 총 4개의 치료 계획을 수립하여 비교하였다. 그리고 TLD를 이용한 측정값 비교는 세기변조방사선치료와 쐐기필터를 이용한 치료를 비교하였고, 납 앞치마의 사용유무에 따라서 세기변조방사선치료의 선량차이를 측정하여 비교·분석하였다. 측정값은 각 포인트마다 3개의 TLD값 평균을 내고 TLD 교정값을 이용하여 환산하였으며 이를 Point dose mean값으로 계산하였다. 치료계획값과 실제 측정값을 비교하기 위해 각 지점마다 절대선량값을 측정하여 %Diff 값으로 계산하였다. 결 과: 치료 중심점인 Point A에서는 치료계획시스템에서 최대 201.7cGy가 나왔고, 실제 TLD 측정값은 최대 200.6cGy가 나왔다. 모든 치료계획시스템에서 유방 경계면으로부터 하방으로 17.5cm 떨어진 지점인 Point G 부터는 0cGy로 계산이 되었다. 실제 TLD 측정 결과 Point G에서는 최대 2.6cGy가 나왔고, 난소선량인 Point J에서는 최대 0.9cGy로 나타났으며 %Diff값은 0.3%~1.3%였다. 납 앞치마의 사용유무에 따른 선량 차이는 최대 2.1cGy에서 최소 0.1cGy로 나타났으며 %Diff값은 0.1%~1.1%였다. 결 론: 치료계획시스템에서 3가지 치료계획에 따른 선량차이는 최저 0.85%에서 최고 2.45%로 큰 격차를 보이지 않았다. 난소에서 Rando humanoid phantom의 치료계획과 실제 측정한 선량차이는 0.9% 이내로 나타났으나 실제 측정에서 조금 더 높게 측정되었다. 이는 치료계획시스템에서 산란선의 영향을 정확하게 반영하지 못하였고, 실제 측정에서는 TLD를 삽입한 상태로 CBCT를 촬영한 선량과 산란선량이 반영된 것으로 사료된다. 납 앞치마의 유무에 따른 선량측정에서 납 앞치마를 사용했을 경우에 치료범위에서 가까운 거리일수록 차폐의 효과가 있었으며, 치료범위에서 15cm 이상 거리가 있는 경우에는 거의 영향을 미치지 않는 것으로 나타났다. 임상적으로 방사선 치료 중에는 임신이나 인공수정을 하기에는 적절하지 않지만, 치료 중 난소에 조사된 선량은 방사선 치료 후 가임기 여성의 생식 기능에 크게 영향을 주지 않을 것으로 생각된다. 하지만 가임 여성의 경우에는 지속적인 불안감을 가지고 있으므로 이번 결과를 통한 데이터를 제시함으로써 심리적인 안정을 도모할 수 있을 것으로 사료된다.

Treatment outcomes of radiotherapy for anaplastic thyroid cancer

  • Park, Jong Won;Choi, Seo Hee;Yoon, Hong In;Lee, Jeongshim;Kim, Tae Hyung;Kim, Jun Won;Lee, Ik Jae
    • Radiation Oncology Journal
    • /
    • 제36권2호
    • /
    • pp.103-113
    • /
    • 2018
  • Purpose: Anaplastic thyroid cancer (ATC) is a rare tumor with a lethal clinical course despite aggressive multimodal therapy. Intensity-modulated radiotherapy (IMRT) may achieve a good therapeutic outcome in ATC patients, and the role of IMRT should be assessed. We retrospectively reviewed outcomes for ATC treated with three-dimensional conformal radiotherapy (3D-CRT) or IMRT to determine the optimal treatment option and explore the role of radiotherapy (RT). Materials and Methods: Between December 2000 and December 2015, 41 patients with pathologically proven ATC received RT with a sufficient dose of ${\geq}40Gy$. Among them, 21 patients (51%) underwent surgery before RT. Twenty-eight patients received IMRT, and 13 received 3D-CRT. Overall survival (OS) and progression-free survival (PFS), patterns of failure, and toxicity were examined. Results: The median follow-up time for survivors was 38.0 months. The median and 1-year OS and PFS rates were 7.2 months and 29%, 4.5 months and 15%, respectively. Surgery significantly improved the prognosis (median OS: 10.7 vs. 3.9 months, p = 0.001; median PFS: 5.9 vs. 2.5 months, p = 0.007). IMRT showed significantly better PFS and OS than 3D-CRT, even in multivariate analysis (OS: hazard ratio [HR] = 0.30, p = 0.005; PFS: HR = 0.33, p = 0.005). Significantly higher radiation dose could be delivered with IMRT than 3D-CRT ($EQD2_{10}$ 66 vs. 60 Gy, p = 0.005). Only 2 patients had grade III dermatitis after IMRT. No other severe toxicity ${\geq}grade$ III occurred. Conclusion: Patients with ATC showed better prognosis through multimodal treatment. Furthermore, IMRT could achieve favorable survival rates by safely delivering higher dose than 3D-CRT.