• Title/Summary/Keyword: 3-D artifact

Search Result 102, Processing Time 0.027 seconds

Performance Comparison of the JPED and Full Frame Bit Allocation Techniques for Medical Image Compression

  • Ahn, C.B.;Ro, D.W.;Lee, J.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.58-63
    • /
    • 1992
  • The discrete cosine transform (DCT)-based progressive coding standard proposed by the International Standardization Orgnnization (ISO) Joint Photographic Experts Groups (JPEG) is investigated for medical image compression and the performance of the JPEG is compared to that of the full-frame bit-allocation (FFBA) technique. From the comparison, the JPEG standard appeals superior to the FFBA technique in the following aspects: 1) JPEG achieves higher compression than the FFBA technique with less mean square error. 2) Less Gibb's artifact is observed in the compressed images by the JPEG. 3) Computational time for the JPEG is about one-fourth or the FFBA technique. Other attractive points of the JPEG include: Implementation of the JPEG with VLSIs is commercially available in relative low price and the JPEG compression format can easily be interchangeable with other applications.

  • PDF

Development of Hand-held OCT probe for Ophthalmic Imaging (안구 영상을 위한 OCT용 손잡이 형 프로브의 개발)

  • Cho, Nam-Hyun;Jung, Woong-Gyu;Jung, Un-Sang;Sephen, A.Boppart;Shim, Jae-Hoon;Kim, Jee-Hyun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.1
    • /
    • pp.24-30
    • /
    • 2011
  • We have developed a hand-held probe for an ophthalmic OCT system. The hand-held probe for imaging was designed to be compact and portable. The cornea and retinal images were acquired by replacing the objective lens at the front of the probe. To verify the performance of the hand-held OCT probe, we acquired two dimensional OCT image of the rat eye in vivo and reconstructed three dimensional rat eye rendering images. In vivo 3D OCT images were showed distinct structural information in the posterior and anterior chamber with minimal motion artifacts. Thereby, OCT imaging speed is suitable for an dynamic in vivo experiment.

A Convergence Study on the Reduction of Noise and Streak Artifacts in Shoulder Joint Computed Tomography (어깨관절 컴퓨터 단층 검사 시 발생하는 노이즈 및 줄무늬 인공물 감소에 대한 융합 연구)

  • Jang, Hyon-Chol;Cho, Pyong-Kon
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.7
    • /
    • pp.189-194
    • /
    • 2021
  • The purpose of this study was to investigate the effect of reducing noise and streaking artefacts by applying the Boost3D algorithm in the case of noise and streaking artifacts generated during computed tomography of the shoulder joint. A phantom study using a thoracic phantom including shoulder joint and clinical evaluation were conducted through shoulder joint images of 35 patients who underwent computed tomography of the shoulder joint from September 2020 to October 2020. The evaluation was divided into groups before and after the application of the Boost3D algorithm, and the noise values, signal to noise ratio, and mean to standard deviation ratio values were analyzed. Both noise values and mean to standard deviation ratio values analyzed in phantom image evaluation and clinical image evaluation were statistically significantly lower in the group after Boost3D was applied (p<0.05). Through this study, it was found that noise and streak artifacts were reduced through the application of Boost3D, and the mean to standard deviation ratio was high, which can be judged as an excellent image. If the Boost3D algorithm is used for computed tomography of the shoulder joint, it is thought that excellent images can be obtained with reduced noise and streaking artifacts that may occur in the shoulder joint area.

Fast Motion Artifact Correction Using l$_1$-norm (l$_1$-norm을 이용한 움직임 인공물의 고속 보정)

  • Zho, Sang-Young;Kim, Eung-Yeop;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.22-30
    • /
    • 2009
  • Purpose : Patient motion during magnetic resonance (MR) imaging is one of the major problems due to its long scan time. Entropy based post-processing motion correction techniques have been shown to correct motion artifact effectively. One of main limitations of these techniques however is its long processing time. In this study, we propose several methods to reduce this long processing time effectively. Materials and Methods : To reduce the long processing time, we used the separability property of two dimensional Fourier transform (2-D FT). Also, a computationally light metric (sum of all image pixel intensity) was used instead of the entropy criterion. Finally, partial Fourier reconstruction, in particular the projection onto convex set (POCS) method, was combined thereby reducing the size of the data which should be processed and corrected. Results : Time savings of each proposed method are presented with different data size of brain images. In vivo data were processed using the proposed method and showed similar image quality. The total processing time was reduced to 15% in two dimensional images and 30% in the three dimensional images. Conclusion : The proposed methods can be useful in reducing image motion artifacts when only post-processing motion correction algorithms are available. The proposed methods can also be combined with parallel imaging technique to further reduce the processing times.

  • PDF

Quantitative analysis of three dimensional volumetric images in Chest CT (흉부 CT 검사에서 3차원 체적 영상의 정량적 분석)

  • Jang, Hyun-Cheol;Cho, Jae-Hwan;Park, Cheol-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.255-260
    • /
    • 2011
  • We wanted to evaluate the usefulness of three-dimensional reconstructive images using computed tomography for rib fracture patients. The reconstruction used in clinical multi planar reformation(MPR), volume rendering technique(VRT), and image data using quantitative methods and qualitative methods were compared. Much more, the artifact shadow was minimized to reconstruct with 3D volumetric image by using an law data in the analysis of the reconstructive image and chest CT scan of the evaluation result fractures of the thoracic patient. And we could know that the fractures of the thoracic determination and three dimension volume image reconstruction time were reduced.

An Advanced Evaluation Process for National R&D Projects based on Global Standards (글로벌스탠다드기반의 국가연구개발사업 평가프로세스)

  • Song, Byung-Sun;Lee, Sun-Hye;Lee, Nam-Yong;Rhew, Sung-Yul
    • The Journal of Society for e-Business Studies
    • /
    • v.13 no.3
    • /
    • pp.103-119
    • /
    • 2008
  • Over the last two decades, national R&D projects have been increased rapidly. The government has tried to improve the success of national R&D projects. But the weakness of the evaluation process for national R&D projects, there remains some problems. In order to solve those problems this study proposed an advanced evaluation process of national R&D projects on the basis of ISO/IEC15288, ISO/IEC12207 and ISO/IEC14598. The evaluation process consists of preparing evaluation, establishing evaluation requirements, specifying evaluation, designing evaluation, executing evaluation and reporting evaluation. The evaluation process is an artifact-oriented process. The results of this study can be used for reforming the evaluation process of national R&D projects.

  • PDF

CT characteristics of normal canine pulmonary arteries and evaluation of optimal contrast delivery methods in CT pulmonary angiography

  • Jung, Joohyun;Chang, Jinhwa;Yoon, Junghee;Choi, Mincheol
    • Korean Journal of Veterinary Research
    • /
    • v.47 no.2
    • /
    • pp.247-254
    • /
    • 2007
  • This study was performed to identify the normal anatomic orientation of pulmonary arteries and to obtain the normal baseline parameters and the optimal contrast material delivery methods of computed tomographic pulmonary angiography (CTPA) on normal beagle dogs. Based on the contrast injection flow rate, the contrast volume, and the administration methods, the experimental groups were divided into 4 groups such as group 1 : 2 ml/s, 3 ml/kg, and monophasic administration; group 2 : 5 ml/s, 3 ml/kg, and monophasic administration; group 3 : 5 ml/s, 4 ml/kg, and monophasic administration; group 4 : 5 ml/s and 2 ml/kg in first phase, 0.3 ml/s and 2 ml/kg in second phase, as biphasic administration. Normal anatomic orientation of pulmonary arteries in CTPA was evaluated through reformatted and 3D images after retro-reconstruction. Normal parameters for great arteries and peripheral pulmonary arteries were obtained on the factor of basement hounsfield unit (HU) values, contrast enhanced HU values, delay time, and peak time. And the optimal contrast delivery methods were evaluated on the factor of contrast enhanced HU values, image quality, and artifact. The monophasic administration with 5 ml/s contrast injection flow rate and 3 ml/kg contrast volume was optimal in canine CTPA.

Effects of NEX on SNR and Artifacts in Parallel MR Images Acquired using Reference Scan

  • Heo, Yeong-Cheol;Lee, Hae-Kag;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.18 no.4
    • /
    • pp.422-427
    • /
    • 2013
  • The aim of this study was to investigate effects of the number of acquisitions (NEX) on signal-to-noise (SNR) and artifacts in SENSE parallel imaging of magnetic resonance imaging (MRI). 3.0T MR System, 8 Channel sensitivity encoding (SENSE) head coils were used along with an in-vivo phantom. Reference sequence of 3D fast field echo (FFE) was consisted of NEX values of 2, 4, 6, 8, 10 and 12. The T2 turbo spin echo (TSE) sequence used for exams achieved SENSE factors of 1.2, 1.5, 1.8, 2.0, 2.2, 2.5, 2.8, 3.0, 3.2, 3.5, 3.8 and 4.0. Exams were conducted five times for each SENSE factor to measure signal intensity of the object, the posterior phase-encode direction and frequency direction. And SNR was calculated using mean values. SENSE artifacts were identified as background signal intensity in the phase-encoded direction using MRIcro. It was found that SNR increased but SENSE artifacts reduced with NEX of 4, 8 and 12 when the NEX increased in reference scan. It is therefore concluded that image quality can be improved with NEX of 4, 8 and 12 for reference scanning.

Development of a 32 Channel EEG and Evoked Potential Mapping System (32채널 뇌파 및 뇌유발전위 Mapping 시스템 개발)

  • Ahn, C.B.;Yoon, G.B.;Park, D.J.;Yoo, S.K.;Lee, S.H.;Ham, Y.J.;Kang, M.J.;Kim, D.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.86-89
    • /
    • 1995
  • A clinically oriented 32 channel Electroencephalogram (EEG) and evoked potential (EP) mapping system has been developed. The EEG and EP signals acquired from 32-channel electrodes are amplified by the pre-amplifier located near patient and are then tither amplified by main amplifier. An automatic artifact rejection scheme is employed using a neural network by which examination time is reduced substantially. Auditary and visual stimuli are used for the evoked potential mapping. A user-friendly graphical interface based on the Microsoft Window 3.1 is developed for the operation of the system. Statistical databases for the poop and individual comparisons are also included to support statistically based diagnosis.

  • PDF

Chemical Constituents of Lathyrus davidii

  • Park, Su-Yeon;Kim, Ju-Sun;Lee, So-Young;Bae, Ki-Hwan;Kang, Sam-Sik
    • Natural Product Sciences
    • /
    • v.14 no.4
    • /
    • pp.281-288
    • /
    • 2008
  • From the MeOH extract of the whole plants of Lathyrus davidii (Fabaceae), thirteen constituents were isolated and identified as the flavonoids astragalin, isoquercitrin, nicotiflorin, and rutin, as the saponins soyasapogenol B 3-O-${\beta}$-D-glucuronopyranoside, azukisaponins II and V, soyasaponins II and V and as 4-O-${\beta}$-Dglucopyranosyl syringic acid, uracil and n-hexacosanol. Five saponins and 4-O-${\beta}$-D-glucopyranosyl syringic acid were isolated from the BuOH fraction as their methyl esters. Ombuoside (rutin 7,4'-di-O-methyl ether) was also isolated from the methylated BuOH-soluble fraction. However, no ombuoside was detected in the HPLC analysis of the nonmethylated BuOH fraction. Therefore, ombuoside is an artifact derived from methylation of rutin. All of these compounds were isolated for the first time from this plant.