• Title/Summary/Keyword: 3-D Reconstruction

Search Result 1,147, Processing Time 0.324 seconds

Gamma Ray Detection Processing in PET/CT scanner (PET/CT 장치의 감마선 검출과정)

  • Park, Soung-Ock;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.125-132
    • /
    • 2006
  • The PET/CT scanner is an evolution in image technology. The two modalities are complementary with CT and PET images. The PET scan images are well known as low resolution anatomic landmak, but such problems may help with interpretation detailed anatomic framework such as that provided by CT scan. PET/CT offers some advantages-improved lesion localization and identification, more accurate tumor staging. etc. Conventional PET employs tranmission scan require around 4 min./bed position and 30 min. for whole body scan. But PET/CT scanner can reduced by 50% in whole body scan. Especially nowadays PET scanner LSO scintillator-based from BGO without septa and operate in 3-D acquisition mode with multidetectors CT. PET/CT scanner fusion problems solved through hardware rather than software. Such device provides with the capability to acquire accurately aligned anatomic and functional images from single scan. It is very important to effective detection from gamma ray source in PETdetector. And can be offer high quality diagnostic images. So we have study about detection processing of PET detector and high quality imaging process.

  • PDF

Surgical Treatment of Ebstein Anomaly (Ebstein 기형의 외과적 치험)

  • 이종호;김병렬
    • Journal of Chest Surgery
    • /
    • v.32 no.1
    • /
    • pp.5-9
    • /
    • 1999
  • Background: Ebstein anomaly is a rare congenital disease distinguished by its unique deformity in tricuspid valve and right ventricle & atrium. In its surgical treatment , tricuspid valve reconstruction and valve replacement are well known method, but various surgical methods were suggested. Material and Method : From January 1984 to December 1995, 8 patients with Ebstein anomaly underwent surgical correction. Age and sex distribution, clinical symtoms, radiologic findings, preoperative studies, operative findings, operative methods and its results were analyzed. Result: The sex ratio was 5 to 3(male : female). Patients' ages were averaged 17.6(2-28) years. In all cases, it showed typical deformities of the tricuspid valve. Associated anomalies were permenant foramen ovale, atrial septum defect, pulmonary stenosis. Surgical procedures included tricuspid valve replacement(n=4) and tricuspid valve reconstuction(n=4). Two cases of sinus tachycardia and complete AV block occured postoperatively. There were two hospital death and no late death. All survivors are in NYHA class I or II with median follow up of 64.8 months. 2-D echocardiogram disclosed improvement tricuspid regurgitation during the follow up period. Conclusion: Even though operative method of Ebstein anomaly should be decided according to each anatomical characteristics, we recommended that tricuspid valvuloplasty and plication can be one of the good methods method in the selective cases.

  • PDF

The Research about Role Area of RT in Digital Environment - Centers on PACS Workplace -

  • Jung, Young-Tae;Park, Bum-Jin;Son, Gi-Gyeong;Jung, Jae-Ho;Kang, Hee-Doo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.1
    • /
    • pp.13-20
    • /
    • 2011
  • Now a days in our society, occupation boundaries have become blurred, and come into the limelight in the prior occupation or miss about new workplace. Medical area is no exception also, So we face urgent problem about protecting and spreading RT work-sphere simultaneously. This research allow to identify on RT role area of digital environment that is obscure profession-realm specially, and open up a new field hereafter. We examined present RT role area of digital environment in the more than thirty medical facility(general or university hospital) through questionnaire/visit survey from PACS administrator. Survey sentence comprises total 29 sentence over all main quadrisection-(eX. hospital formation & treatment state and PACS team composition & organization and PACS team workplace and PACS team daily workload), We performed comparative analysis in general contents perspectively. further more, divided main 5 section based on upper analysis and then manufactured output in consideration of each medical facility's operation state. There are comparative problem of hospital policy, So we maintained information security of each facility exhaustively. First, we separated a survey output into main 5 section as follows-(eX. PACS server & maintenance manage, Client/interlock manage, PACS data conversion, 3D reconstruction, PACS data im/export)-that received by 35 medical facility. And then manufactured output with comparative analysis about RT role area each section, general IT managing team about medical environment was out of existence that fill up with RT manpower in the surveyed medical facility consequently. What is worse, hospitals that entirely fill up with another worker were 3 place amazingly. Our specific statistic results show, the respondents was 63% that agree with reorganization of formation base on independence team, and supplement of the personnel average -continuous with upper agreement simply-was about 2.64. Further more, if reorganization break out with only RT manpower, quota TO will increase by geometric progression. Protecting and spreading role workplace is much accounted of the our inevitable project surely and more than 95% PACS administrator's have confidence in this proposition unconditionally. Henceforth, look forward to meeting the RT vision of many-sided multiplayer, based on acquire a specialized IT knowledge actively and open up a new work-field with frontier spirit.

  • PDF

Evaluation of Total Lung Volume and Density using Multi-Detector Computed Tomography in Normal Dogs (정상견에서 다중채널 컴퓨터단층촬영술을 통한 폐용적과 밀도의 평가)

  • Choi, Ho-Jung;Lee, Ki-Ja;Choi, Soo-Young;Lee, Jung-Woo;Han, Woo-Sok;Lee, In;Kwon, Young-Hang;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.28 no.5
    • /
    • pp.510-515
    • /
    • 2011
  • This study was performed to quantitatively assess the normal lung volume and density according to the position by multi-detector computed tomography (MDCT) in dogs. Helical CT of the thorax was performed on 4 different positions with dorsal, left lateral, right lateral and ventral recumbency in 6 Pekingese and 6 Maltese dogs. During CT scanning, dogs were kept hyperventilated. Through the 3-dimensional reconstruction of CT images, the lung parameters were measured as the volume and density of the left, right including accessory lobe, and total lung. 3D images represented the different lung shape between Pekingese and Maltese dogs. Their difference of total lung volume and total lung density was not significant on the each position in both breeds. Right lung volume was significantly higher than left. The difference of left and right volume was $66.91{\pm}25.1$ ml. Linear relationship was shown between body weight and lung volume of ventral recumbency position. The dependent lung had higher density and lower volume than nondependent lung in both breed dogs. The volume of nondependent lung was not changed compared with the volume on ventral or dorsal recumbency. The total lung volume measured with MDCT is correlated with the lung density, and the lung density is useful to predict the normal total lung volume.

Development of cardiopulmonary resuscitation nursing education program of web-based instruction (웹 기반의 심폐소생술 간호교육 프로그램 개발)

  • Sin, Hae-Won;Hong, Hae-Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.4 no.1
    • /
    • pp.25-39
    • /
    • 2002
  • The purpose of this study is to develop and evaluate a web-based instruction Program(WBI) to help nurses improving their knowledge and skill of cardiopulmonary resuscitation. Using the model of web-based instruction(WBI) program designed by Rhu(1999), this study was carried out during February-April 2002 in five different steps; analysis, design, data collection and reconstruction, programming and publishing, and evaluation. The results of the study were as follows; 1) The goal of this program was focused on improving accuracy of knowledge and skills of cardiopulmonary resuscitation. The program texts consists of the concepts and importances of cardiopulmonary resuscitation(CPR), basic life support(BLS), advanced cardiac life support(ACLS), treatment of CPR, nursing care after CPR treatment. And in the file making step, photographs, drawings and image files were collected and edited by web-editor(Namo), scanner and Adobe photoshop program. Then, the files were modified and posted on the web by file transfer protocol(FTP). Finally, the program was demonstrated and once again revised by the result, and then completed. 2) For the evaluation of the program, 36 nurses who in K university hospital located in D city, and related questionnaire were distributed to them as well. Higher scores were given by the nurses in its learning contents with $4.2{\pm}.67$, and in its structuring and interaction of the program with $4.0{\pm}.79$, and also in its satisfactory of the program with $4.2{\pm}.58$ respectively. In conclusion, if the contents of this WBI educational program upgrade further based upon analysis and applying of the results the program evaluation, it is considered as an effective tool to implement for continuing education as life-long educational system for nurse.

  • PDF

Evaluation of Image Quality Change by Truncated Region in Brain PET/CT (Brain PET에서 Truncated Region에 의한 영상의 질 평가)

  • Lee, Hong-Jae;Do, Yong-Ho;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.68-73
    • /
    • 2015
  • Purpose The purpose of this study was to evaluate image quality change by truncated region in field of view (FOV) of attenuation correction computed tomography (AC-CT) in brain PET/CT. Materials and Methods Biograph Truepoint 40 with TrueV (Siemens) was used as a scanner. $^{68}Ge$ phantom scan was performed with and without applying brain holder using brain PET/CT protocol. PET attenuation correction factor (ACF) was evaluated according to existence of pallet in FOV of AC-CT. FBP, OSEM-3D and PSF methods were applied for PET reconstruction. Parameters of iteration 4, subsets 21 and gaussian 2 mm filter were applied for iterative reconstruction methods. Window level 2900, width 6000 and level 4, 200, width 1000 were set for visual evaluation of PET AC images. Vertical profiles of 5 slices and 20 slices summation images applied gaussian 5 mm filter were produced for evaluating integral uniformity. Results Patient pallet was not covered in FOV of AC-CT when without applying brain holder because of small size of FOV. It resulted in defect of ACF sinogram by truncated region in ACF evaluation. When without applying brain holder, defect was appeared in lower part of transverse image on condition of window level 4200, width 1000 in PET AC image evaluation. With and without applying brain holder, integral uniformities of 5 slices and 20 slices summation images were 7.2%, 6.7% and 11.7%, 6.7%. Conclusion Truncated region by small FOV results in count defect in occipital lobe of brain in clinical or research studies. It is necessary to understand effect of truncated region and apply appropriate accessory for brain PET/CT.

  • PDF

The Usefulness of LEUR Collimator for 1-Day Basal/Acetazolamide Brain Perfusion SPECT (1-Day Protocol을 사용하는 Brain Perfusion SPECT에서 LEUR 콜리메이터의 유용성)

  • Choi, Jin-Wook;Kim, Soo-Mee;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.94-100
    • /
    • 2011
  • Purpose: Basal/Acetazolamide-challenged brain perfusion SPECT is very useful to assess cerebral perfusion and vascular reserve. However, as there is a trade off between sensitivity and spatial resolution in the selection of collimator, the selection of optimal collimator is crucial. In this study, we examined three collimators to select optimal one for 1-day brain perfusion SPECT. Materials and Methods: Three collimators, low energy high resolution-parallel beam (LEHR-par), ultra resolution-fan beam (LEUR-fan) and super fine-fan beam (LESFR-fan), were tested for 1-day imaging using Triad XLT 9 (TRIONIX). The SPECT images of Hoffman 3D brain phantom filled with 99mTc of 170 MBq and a normal volunteer were acquired with a protocol of 50 kcts/frame and detector rotation of 3 degree. Filterd backprojection (FBP) reconstruction with Butterworth filter (cut off frequencies, 0.3 to 0.5) was performed. The quantitative and qualitative assessments for three collimators were performed. Results: The blind tests showed that LESFR-fan provided the best image quality for Hoffman brain phantom and the volunteer. However, images for all the collimator were evaluated as 'acceptable'. On the other hand, in order to meet the equivalent signal-to-noise ratio (SNR), total acquisition time or radioactivity dose for LESFR-fan must have been increased up to almost twice of that for LEUR-fan and LEHR-par. The volunteer test indicated that total acquisition time could be reduced approximately by 10 to 14 min in clinical practice using LEUR-fan and LEHR-par without significant loss on image quality, in comparison with LESFR-fan. Conclusion: Although LESFR-fan provides the best image quality, it requires significantly more acquisition time than LEUR-fan and LEHR-par to provide reasonable SNR. Since there is no significant clinical difference between three collimators, LEUR-fan and LEHR-par can be recommended as optimal collimators for 1-day brain perfusion imaging with respect to image quality and SNR.

  • PDF

Effects of enamel matrix derivative and titanium on the proliferation and differentiation of osteoblasts (법랑기질유도체를 도포한 타이태늄 표면에서 조골세포의 증식 및 분화)

  • Park, Sang-Hyun;Lee, In-Kyeong;Yang, Seung-Min;Shin, Seung-Yun;Lee, Yong-Moo;Ku, Young;Rhyu, In-Chul;Chung, Chong-Pyoung;Han, Soo-Boo;Choi, Sang-Mook
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.3
    • /
    • pp.359-372
    • /
    • 2003
  • Among objectives of periodontal therapy. the principal one is the morphological and functional reconstruction of lost periodontal supporting tissues. This includes de novo formation of connective tissue attachment and the regrowth of alveolar bone. The use of enamel matrix derivative(EMD) may be a suitable means of regeneration new periodontal attachment in the infrabony defects. Implant used to replace lost tooth but, implantitis occurred after installation. The purpose of this study was to investigate the effects of EMD on differentiation and growth of osteoblast in titanium disc. Twentyfive millimeter diameter and 1mm thick Ti disc which was coated 25, 50, 100, 200${\mu}g$/ml of EMD(Emdogain(R)) used as experimental group, 25, 50, 100, 200ng/d of rhBMP-2 as positive control group, and no coat as negative control group. A human osteosarcoma cell line Saos-2 was cultured in Ti disc and cell proliferation and Alkaline phosphatase (ALP) activity were measured at 1 and 6 days. PCR was performed at 2 and 8 hours. Semi-quantitative RT-PCR for mRNA expressions of various osteoblastic differentiation markers -type I collagen, ALP, osteopontin, and bone sialoprotein - were performed at appropriate concentrations based upon the results of MTT and ALP assay. Cultured cell-disc complexes were prepared for scanning electron microscopy (SEM) at 2 hour. Data were analyzed using Mann-Whitney and repeated- measures 1-way analysis of variance(SPSS software version 10,SPSS. Chicago. IL). After culture, there was more osteoblast in EMD100${\mu}g$/ml than in EMD50, 200${\mu}g$/ml on day 6. There was significant difference in experimental and positive control group compared control group, as times go by(1 and 6 days). Alkaline phosphatase activity was different significantly in EMD100, 200${\mu}g$/ml and BMP100, 200${\mu}g$/ml on day 6. The results of reverse transcriptase-polymerase chain reaction (RT-PCR) showed that expression of mRNA for ALPase, collagen type I, osteopontin. hone sialoprotein and BMP-2 was detected at 2 hour and 8 hour in EMI 200${\mu}g$/ml subgroup and BMP100ng/ml subgroup. The results of this study suggest that application of enamel matrix derivative on osteoblast attached to titanium surface facilitate the expression of bone specific protein and the differentiation and growth of osteoblast.

Stratigraphy and Paleoenvironment of Domi-1 and Sora-1 Wells, Domi Basin (도미분지 도미-1, 소라-1공의 층서와 고환경)

  • Yun, Hye-Su;Byun, Hyun-Suk;Oh, Jin-Yong;Park, Myong-Ho;Lee, Min-Woo
    • Economic and Environmental Geology
    • /
    • v.45 no.4
    • /
    • pp.407-429
    • /
    • 2012
  • There has been much debates on the geologic age of the sediments of the Domi Basin, since age results varied after research methods and fossil groups. This study carried out palynological analysis and seismic interpretation to establish a stratigraphy and environmental reconstruction mainly based on fossil dinoflagellates and Seismic data from the Domi-1 and Sora-1 wells. The dinocyst assemblages found enabled zonation of the well sediment sequence resulting in 4 ecozones. Index fossils among dinocysts and palynomorphic substances indicate geologic age of the well ranges from Eocene to Pleistocene, and paleoenvironment varies from freshwater to inner-neritic marine. The fossil association also suggests strong relationship to Japanese Tertiary basins in Kyushu area in terms of stratigraphy and basin developmental history.

Fast Motion Artifact Correction Using l$_1$-norm (l$_1$-norm을 이용한 움직임 인공물의 고속 보정)

  • Zho, Sang-Young;Kim, Eung-Yeop;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.22-30
    • /
    • 2009
  • Purpose : Patient motion during magnetic resonance (MR) imaging is one of the major problems due to its long scan time. Entropy based post-processing motion correction techniques have been shown to correct motion artifact effectively. One of main limitations of these techniques however is its long processing time. In this study, we propose several methods to reduce this long processing time effectively. Materials and Methods : To reduce the long processing time, we used the separability property of two dimensional Fourier transform (2-D FT). Also, a computationally light metric (sum of all image pixel intensity) was used instead of the entropy criterion. Finally, partial Fourier reconstruction, in particular the projection onto convex set (POCS) method, was combined thereby reducing the size of the data which should be processed and corrected. Results : Time savings of each proposed method are presented with different data size of brain images. In vivo data were processed using the proposed method and showed similar image quality. The total processing time was reduced to 15% in two dimensional images and 30% in the three dimensional images. Conclusion : The proposed methods can be useful in reducing image motion artifacts when only post-processing motion correction algorithms are available. The proposed methods can also be combined with parallel imaging technique to further reduce the processing times.

  • PDF