• 제목/요약/키워드: 3-D Mode Shape

검색결과 121건 처리시간 0.029초

Comparison of semi-active and passive tuned mass damper systems for vibration control of a wind turbine

  • Lalonde, Eric R.;Dai, Kaoshan;Bitsuamlak, Girma;Lu, Wensheng;Zhao, Zhi
    • Wind and Structures
    • /
    • 제30권6호
    • /
    • pp.663-678
    • /
    • 2020
  • Robust semi-active vibration control of wind turbines using tuned mass dampers (TMDs) is a promising technique. This study investigates a 1.5 megawatt wind turbine controlled by eight different types of tuned mass damper systems of equal mass: a passive TMD, a semi-active varying-spring TMD, a semi-active varying-damper TMD, a semi-active varying-damper-and-spring TMD, as well as these four damper systems paired with an additional smaller passive TMD near the mid-point of the tower. The mechanism and controllers for each of these TMD systems are explained, such as employing magnetorheological dampers for the varying-damper TMD cases. The turbine is modelled as a lumped-mass 3D finite element model. The uncontrolled and controlled turbines are subjected to loading and operational cases including service wind loads on operational turbines, seismic loading with service wind on operational turbines, and high-intensity storm wind loads on parked turbines. The displacement and acceleration responses of the tower at the first and second mode shape maxima were used as the performance indicators. Ultimately, it was found that while all the semi-active TMD systems outperformed the passive systems, it was the semi-active varying-damper-and-spring system that was found to be the most effective overall - capable of controlling vibrations about as effectively with only half the mass as a passive TMD. It was also shown that by reducing the mass of the TMD and adding a second smaller TMD below, the vibrations near the mid-point could be greatly reduced at the cost of slightly increased vibrations at the tower top.

DEEP-South: The Photometric Study of Non-Principal Axis Rotator (5247) Krylov

  • Lee, Hee-Jae;Moon, Hong-Kyu;Kim, Myung-Jin;Kim, Chun-Hwey;Durech, Josef;Park, Jintae;Roh, Dong-Goo;Choi, Young-Jun;Yim, Hong-Suh;Oh, Young-Seok
    • 천문학회보
    • /
    • 제41권2호
    • /
    • pp.49.2-49.2
    • /
    • 2016
  • The number of discovery of asteroids with peculiar rotational states has recently increased, and hence a novel approach for lightcurve analysis is considered to be critical. In order to investigate objects such as Non-Principal Axis (NPA) rotator, we selected a NPA candidate, (5247) Kryolv as our target considering its Principal Axis Rotation (PAR) code and the visibility in early 2016. The observations of Krylov were made using Korea Microlensing Telescope Network (KMTNet) 1.6 m telescopes installed at the three southern sites with TO (Target of Opportunity) observation mode. We conducted R-band time-series photometry over a total of 51 nights from January to April 2016 with several exposures during each allocated run. The ensemble normalization photometry was employed using the AAVSO Photomtric All-Sky Survey (APASS) catalog for the standardization. We successfully confirmed its NPA spin state based on the deviation from the reduced lightcurve, and thus Krylov is recorded as the first NPA rotator of its kind in the main-belt, with its precession and rotation periods, $P{\varphi}=81.18h$ and $P_{\Psi}=67.17h$, respectively. In this paper, we present the spin direction, the 3D shape model and taxonomy of the newly confirmed NPA asteroid (5247) Krylov.

  • PDF

Soil and ribbed concrete slab interface modeling using large shear box and 3D FEM

  • Qian, Jian-Gu;Gao, Qian;Xue, Jian-feng;Chen, Hong-Wei;Huang, Mao-Song
    • Geomechanics and Engineering
    • /
    • 제12권2호
    • /
    • pp.295-312
    • /
    • 2017
  • Cast in situ and grouted concrete helical piles with 150-200 mm diameter half cylindrical ribs have become an economical and effective choice in Shanghai, China for uplift piles in deep soft soils. Though this type of pile has been successful used in practice, the reinforcing mechanism and the contribution of the ribs to the total resistance is not clear, and there is no clear guideline for the design of such piles. To study the inclusion of ribs to the contribution of shear resistance, the shear behaviour between silty sand and concrete slabs with parallel ribs at different spacing and angles were tested in a large direct shear box ($600mm{\times}400mm{\times}200mm$). The front panels of the shear box are detachable to observe the soil deformation after the test. The tests were modelled with three-dimensional finite element method in ABAQUS. It was found that, passive zones can be developed ahead of the ribs to form undulated failure surfaces. The shear resistance and failure mode are affected by the ratio of rib spacing to rib diameter. Based on the shape and continuity of the failure zones at the interface, the failure modes at the interface can be classified as "punching", "local" or "general" shear failure respectively. With the inclusion of the ribs, the pull out resistance can increase up to 17%. The optimum rib spacing to rib diameter ratio was found to be around 7 based on the observed experimental results and the numerical modelling.

비선형 동적 해석을 이용한 비내진 상세 RC 골조의 지진거동 특성 분석 (A Study on the Seismic Response of a Non-earthquake Resistant RC Frame Using Inelastic Dynamic Analyses)

  • 정성훈;이광호;이수권
    • 콘크리트학회논문집
    • /
    • 제22권3호
    • /
    • pp.381-388
    • /
    • 2010
  • 이 논문에서는 내진상세가 적용되지 않은 RC골조의 지진 거동 특성을 파악하였다. 해석 대상 건물은 내진 규준의 적용을 받지 않고 중력하중만을 고려하여 설계되었다. 원형철근이 주철근으로 사용되었으며, 부재는 낮은 수준의 전단력을 견딜 수 있는 최소한의 스터럽이 사용되어 코어 부분의 구속효과는 거의 없다. 평면비정형성을 가진 건물의 경우, 푸쉬오버 해석을 통해서는 비틀림으로 인한 평면상에서 연단부의 손상집중을 파악할 수 없으므로 비선형 동적해석을 사용하는 것이 바람직하다. 섬유요소를 이용한 비선형 동적해석은 양방향 지진하중과 비틀림 거동의 영향을 받는 RC골조의 거동을 성공적으로 예측할 수 있었다. 하지만, 보다 진보된 응답 예측을 위해서는 부착 미끄러짐과 같은 보-기둥 접합부의 국부거동을 정밀하게 나타내는 모델링 요소의 개발이 필요하다.

The intrinsic instabilities of fluid flow occured in the melt of Czochralski crystal growth system

  • Yi, Kyung-Woo;Koichi Kakimoto;Minoru Eguchi;Taketoshi Hibiya
    • 한국결정성장학회:학술대회논문집
    • /
    • 한국결정성장학회 1996년도 The 9th KACG Technical Annual Meeting and the 3rd Korea-Japan EMGS (Electronic Materials Growth Symposium)
    • /
    • pp.179-200
    • /
    • 1996
  • The intrinsic instabilities of fluid flow occurred in the melt of the Czochralski crystal growth system Czochralski method, asymmetric flow patterns and temperature profiles in the melt have been studied by many researchers. The idea that the non-symmetric structure of the growing equipment is responsible for the asymmetric profiles is usually accepted at the first time. However further researches revealed that some intrinsic instabilities not related to the non-symmetric equipment structure in the melt could also appear. Ristorcelli had pointed out that there are many possible causes of instabilities in the melt. The instabilities appears because of the coupling effects of fluid flow and temperature profiles in the melt. Among the instabilities, the B nard type instabilities with no or low crucible rotation rates are analyzed by the visualizing experiments using X-ray radiography and the 3-D numerical simulation in this study. The velocity profiles in the Silicon melt at different crucible rotation rates were measured using X-ray radiography method using tungsten tracers in the melt. The results showed that there exits two types of fluid flow mode. One is axisymmetric flow, the other is asymmetric flow. In the axisymmetric flow, the trajectory of the tracers show torus pattern. However, more exact measurement of the axisymmetrc case shows that this flow field has small non-axisymmetric components of the velocity. When fluid flow is asymmetric, the tracers show random motion from the fixed view point. On the other hand, when the observer rotates to the same velocity of the crucible, the trajectory of the tracer show a rotating motion, the center of the motion is not same the center of the melt. The temperature of a point in the melt were measured using thermocouples with different rotating rates. Measured temperatures oscillated. Such kind of oscillations are also measured by the other researchers. The behavior of temperature oscillations were quite different between at low rotations and at high rotations. Above experimental results means that the fluid flow and temperature profiles in the melt is not symmetric, and then the mode of the asymmetric is changed when rotation rates are changed. To compare with these experimental results, the fluid flow and temperature profiles at no rotation and 8 rpm of crucible rotation rates on the same size of crucible is calculated using a 3-dimensional numerical simulation. A finite different method is adopted for this simulation. 50×30×30 grids are used. The numerical simulation also showed that the velocity and flow profiles are changed when rotation rates change. Futhermore, the flow patterns and temperature profiles of both cases are not axisymmetric even though axisymmetric boundary conditions are used. Several cells appear at no rotation. The cells are formed by the unstable vertical temperature profiles (upper region is colder than lower part) beneath the free surface of the melt. When the temperature profile is combined with density difference (Rayleigh-B nard instability) or surface tension difference (Marangoni-B nard instability) on temperature, cell structures are naturally formed. Both sources of instabilities are coupled to the cell structures in the melt of the Czochralski process. With high rotation rates, the shape of the fluid field is changed to another type of asymmetric profile. Because of the velocity profile, isothermal lines on the plane vertical to the centerline change to elliptic. When the velocity profiles are plotted at the rotating view point, two vortices appear at the both sides of centerline. These vortices seem to be the main reason of the tracer behavior shown in the asymmetric velocity experiment. This profile is quite similar to the profiles created by the baroclinic instability on the rotating annulus. The temperature profiles obtained from the numerical calculations and Fourier transforms of it are quite similar to the results of the experiment. bove esults intend that at least two types of intrinsic instabilities can occur in the melt of Czochralski growing systems. Because the instabilities cause temperature fluctuations in the melt and near the crystal-melt interface, some defects may be generated by them. When the crucible size becomes large, the intensity of the instabilities should increase. Therefore, to produce large single crystals with good quality, the behavior of the intrinsic instabilities in the melt as well as the effects of the instabilities on the defects in the ingot should be studied. As one of the cause of the defects in the large diameter Silicon single crystal grown by the

  • PDF

Improved Device Performance Due to AlxGa1-xAs Barrier in Sub-monolayer Quantum Dot Infrared Photodetector

  • Han, Im Sik;Byun, Young-Jin;Lee, Yong Seok;Noh, Sam Kyu;Kang, Sangwoo;Kim, Jong Su;Kim, Jun Oh;Krishna, Sanjay;Ku, Zahyun;Urbas, Augustine;Lee, Sang Jun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.298-298
    • /
    • 2014
  • Quantum dot infrared photodetectors (QDIPs) based on Stranski-Krastanov (SK) quantum dots (QDs) have been widely explored for improved device performance using various designs of heterostructures. However, one of the biggest limitations of this approach is the "pancake" shape of the dot, with a base of 20-30 nm and a height of 4-6 nm. This limits the 3D confinement in the quantum dot and reduces the ratio of normal incidence absorption to the off-axis absorption. One of the alternative growth modes to the formation of SK QDs is a sub-monolayer (SML) deposition technique, which can achieve a much higher density, smaller size, better uniformity, and has no wetting layer as compared to the SK growth mode. Due to the advantages of SML-QDs, the SML-QDIP design has attractive features such as increased normal incidence absorption, strong in-plane quantum confinement, and narrow spectral wavelength detection as compared with SK-DWELL. In this study, we report on the improved device performance of InAs/InGaAs SML-QDIP with different composition of $Al_xGa1-_xAs$ barrier. Two SML-QDIPs (x=0.07 for sample A and x=0.20 for sample B) are grown with the 4 stacks 0.3 ML InAs. It is investigated that sample A with a confinement-enhanced (CE) $Al_{0.22}Ga_{0.78}As$ barrier had a single peak at $7.8{\mu}m$ at 77 K. However, sample B with an $Al_{0.20}Ga_{0.80}As$ barrier had three peaks at (${\sim}3.5{\mu}m$, ${\sim}5{\mu}m$, ${\sim}7{\mu}m$) due to various quantum confined transitions. The measured peak responsivities (see Fig) are ~0.45 A/W (sample A, at $7.8{\mu}m$, $V_b=-0.4V$ bias) and ~1.3 A/W (sample B, at $7{\mu}m$, $V_b=-1.5V$ bias). At 77 K, sample A and B had a detectivity of $1.2{\times}10^{11}cm.Hz^{1/2}/W$ ($V_b=-0.4V$ bias) and $5.4{\times}10^{11}cm.Hz^{1/2}/W$ ($V_b=-1.5V$ bias), respectively. It is obvious that the higher $D^*$ of sample B (than sample A) is mainly due to the low dark current and high responsivity.

  • PDF

바텀애쉬와 폐유리를 사용하여 제조한 저온소성 경량골재의 열전도율과 기공특성 (Thermal Conductivity and Pore Characteristics of Low-Temperature Sintered Lightweight Aggregates Mode from Waste Glass and Bottom Ash)

  • 이한백;지석원;서치호
    • 콘크리트학회논문집
    • /
    • 제22권6호
    • /
    • pp.851-858
    • /
    • 2010
  • 이 연구에서는 대부분 폐기 매립되고 있는 산업부산물의 재활용 기술을 확보하고자, 연화점이 $700^{\circ}C$ 수준으로 낮은 폐유리와 에너지 연소물질을 포함하고 있는 바텀애쉬를 모재로 기존 경량골재의 소성온도보다 20~30%가 낮은 $800{\sim}900^{\circ}C$에서 제조가능한 에너지 절감형 저온소성 경량골재를 제조하고자 하였다. 경량골재의 열전도율은 $0.056{\sim}0.105W/m{\cdot}K$ 수준, 기공률은 40.36~84.89% 수준으로 나타났다. 열전도율과 기공률의 상관계수는 -0.97로 매우 높은 음(-)의 상관성을 보였는데, 기공률이 단열특성을 좌우하는 핵심 요소임을 확인할 수 있었다. 각 소성온도별 $CaCO_3$ 첨가량과 바텀애쉬 치환율에 따른 경량골재의 미세구조는 소성온도에 상관없이 $CaCO_3$ 첨가량이 증가할수록 기공크기도 증가하고, 바텀애쉬 치환율이 증가할수록 기공크기는 작아지며 일정하지 못하였다. 특히 바텀애쉬를 30% 치환한 경우 대부분의 기공형태가 구(球)형태의 폐기공이 아닌 불규칙한 형태의 개기공으로 존재했으며 기공크기도 바텀애쉬 0~20% 치환 사용한 경우에 비해 약 1/10~1/5 수준으로 관찰되었다. 또한 바텀애쉬 30% 치환시 소성온도 $900^{\circ}C$의 경우가 $700^{\circ}C$, $800^{\circ}C$에서 보다 더욱 불규칙한 형태의 개기공이 두드러지게 나타났는데, 이는 경량골재의 흡수율 증가, 강도 저하, 단열특성 저하에 일정부분 기여할 것으로 판단된다.

Ovality가 세그먼트 라이닝의 동적 거동 특성에 미치는 영향 (The effect of tunnel ovality on the dynamic behavior of segment lining)

  • 이경주;송기일
    • 한국터널지하공간학회 논문집
    • /
    • 제25권6호
    • /
    • pp.423-446
    • /
    • 2023
  • 쉴드 TBM 터널 라이닝은 세그먼트와 링으로 분절되어 있다. 2-링 빔-스프링 모델은 세그먼트 라이닝의 링과 세그먼트의 연결부 경계조건을 통해 불연속성을 고려하며 단면 설계 시 주로 활용하는 모델링 방법이다. 그러나 3차원 해석이 필요한 경우 대체로 Segmentation에 대한 고려 없이 연속체 라이닝으로 간주하여 세그먼트 라이닝에 대한 응력과 변위를 검토하는 경향이 일반적이다. 본 연구는 세그먼트와 링의 접촉면에 Coulomb의 마찰 법칙에 근거한 Shell interface element를 적용하여 세그먼트 간 계면 거동하는 모델링으로 지진 시 세그먼트 라이닝의 응력과 변위에 대한 응답 특성을 연구한다. 세그먼트 라이닝은 건설 과정에서 Ovaling 변형이 발생된다. 국내 세그먼트 라이닝의 Ovaling 변형에 대한 관리 기준은 없다. 스웨덴이나 중국의 경우 내경 7.0 m의 라이닝인 경우 5~10‰의 Ovality 기준을 갖고 있으나 이는 현실적으로 실현하기 어려운 기준치이다. 본 연구는 Shell interface element를 활용한 세그먼트 라이닝 모델링을 통해 지진 시 라이닝에 발생되는 응력과 변위의 특성을 연속체 모델링 결과와 비교하여 Segmentation이 고려된 라이닝의 지진에 대한 응답 특성을 연구하고 이를 통해 세그먼트 라이닝의 Ovality 기준과 의미를 연구한다. 연속체 라이닝과 세그먼트 라이닝의 지진 시 응력과 변위의 분포 양상은 유사하였다. 그러나 응력과 변위의 최댓값은 세그먼트 라이닝과 차이를 보여주었다. Shell로 모델링 된 연속체 라이닝의 지진 시 응력 분포는 3차원 원통형 형상에 연속성을 갖는 응력 분포를 보이지만 세그먼트 라이닝은 분절된 세그먼트 외측으로 응력이 집중되었고 세그먼트와 링의 접촉면이 집중되는 위치에서 가장 큰 응력이 발생되었다. 이러한 단속적이고 국부적 응력 분포는 라이닝의 Ovality가 클수록 지진 시 더욱더 국부적 집중도가 커진다. 응력 분포가 급격하게 커지는 Ovality는 150‰ 정도에서 발생되기 시작했으며 그보다 작은 Ovality 에서는 원형 단면 라이닝에서 발생되는 응력보다 작은 응력이 발생되었다. 그러나 Ovality 150‰는 실제 라이닝에서 실현될 수 없는 비현실적 값이다. 따라서 세그먼트 라이닝의 Ovality는 심도에 따라 증가될 수 있으나 지진 하중에 대한 안정성에는 큰 영향을 미치지 않는다. 그러나 터널의 단면 확보 및 품질관리를 위해서는 Ovality에 대한 계측과 관리가 요구된다.

카톨릭교 전례복에 관한 연구-독일 Paderborn 과 kevelaer의 전례복 회사를 중심으로 (A Study on the Liturgical Vestments of Catholic-With reference to the Liturgical Vestments Firm of Paderborn and kevelaer in Germany)

  • 양리나
    • 자연과학논문집
    • /
    • 제7권
    • /
    • pp.133-162
    • /
    • 1995
  • 전례복의 전통을 고수하며 최상의 예술적 가치를 지닌 제의를 생산하는 Paderborn의 Wameling과 Cassau, 그리고 성모마리아 성지 순례지인 Kevelaer에 위치한 Kevelaerer Fahnen + Paramenten GmbH는 "Hidden Company"로 전유럽과 아프리카, 미국과 스칸디나비아 반도에 까지 널리 알려진 독일의 전례복기업으로 수 세기동안 종교적인 중심이 서 있던곳, 교회의 예식의 삶이 발전되어온 곳, 바로 그곳에서 계속해서 오늘날까지 예술의 수호자와 격려자로서의 모습을 굳건이 지켜나가고 있다. 이러한 3개 회사를 통하여 알아본 카톨릭 전례복은 다양한 모양과 색채, 형태와 기법을 사용하여 단순한 종교적 상징성을 넘어 미적인 화려함과 조형적인 조화로 현대직물예술, 미술의상, 그리고 디자인 전반에 활용이 기대되며, 신자들에게는 전례복에 대한 상징의 미와 조화에 대한 이해를 돕고, 비신자들로 하여금은 종교예술에 대한 의식과 관심이 정식적인 사고나 신앙심을 유발시키는데 중요한 영향을 끼치리라 본다. 전례복은 성직자가 미사. 성사. 집행. 행렬. 강복등의 모든 의식때 교회규정에 따라 입는 예복들을 총칭하는 말이다. 이러한 전례복은 무언의 언어로써 신성의 표현을 겉으로 드러낸것으로 세속인과 성직자를 구별해준다. 또 예식을 집행하는 사제의 몸짓과 동작, 언어를 뒷받침하여 전례의 뜻을 더욱 시각적으로 강하게 나타내 주고, 성직자로 하여금 성직의 직무에 더욱 충실할수 있도록 심리적영향도 준다. 이뿐만 아니라 전례복은 성직자의 지위와 권위를 나타내며 신자들로 하여금 성직자에 대한 위엄과 존경심을 불러 일으키고 전례복의 상징과 색체를 통해 전례의식의 기쁨과 슬픔을 심리적으로 공감하여 예식의 아름답고 신비스런 분위기를 창출하게 하므로 더 한층 신앙의 깊이를 부과시켜 준다. 전례복은 그리이스, 로마의 초상기 세속복이 종교적 경향을 띄면서 기독교 복식으로 자리 잡은 것으로, 313년 로마 Constantinus 황제에 의해 기독교가 공인되기 전까지는 세속인과 구별되는 특별한 제복은 없었다. 인간의 심리를 가장 잘 표현한 제의의 색채도 원래는 순수 흰색이었던 것이 12C 교황 Innocentius 3세에 의해 전례축일과 각 시기에 따라 특수한 색채를 사용하도록 규정되었으며, 현재의 전례복 색채의 상징적 의미는 교황 St. Pius (재위1566-1572)에 의해서 지니게 되었다. 장식과 소재도 초창기에는 대부분 모, 아마등이 사용되다가 4C부터 비단과 같은 특별한 소재가 사용되기 시작하였고 12C에는 금실로 직조된 화려한 소재가 사용되었다. 장식으로는 상징 문양의 자수, 직조, 아프리케의 견고하고 아름다운 장식이 널리 사용된다. 또 형태는 전통적으로 가장 널리 사용되어온 반원형의 풍성한 제의가 죄를 덮어주는 자비의 상징으로 오늘날 다시 유행하고 있다. 미래의 제의 형태도 결정적인 큰 변화는 없을 것으로 예측된다. 전례복의 발전은 계속해서 보수적인 교회의 명령에 의해 움직여질것이며 오늘날까지 변화해온 그 방식 그대로 각 시대의 문화와 시대정신, 복식의 유행에 따라 조금씩 변화의 과정을 거쳐 시대감각에 적합하도록 단순하고, 간편하게 변해갈 것이다. 사제의 수가 줄고 전례용품의 수요가 급격히 줄어들지도 모르는 판매 부진의 시기가 곧 닥쳐오게 될지도 모르는 상황속에서도 전례복기업들은 각기업의 전례복 차별화와 예술적 진보를 위해 끊임없이 다양한 문양, 자수기술 개발, 창조적인 형태의 디자인 실현을 통하여 세계속에서 초 일류기업으로 당당하게 경쟁할 능력을 준비하고 있다. 또 각기업은 예술가의 적극적인 관심과 참여의식을 유도하고, 전시회와 전속예술가를 위한 Atelier를 마련하며, 다른 회사의 전례복과 구별되는 직물의 생산을 위해 자가 직물공장을 세우거나, 한 회사만을 위하여 직물을 생산토록 독점계약을 맺는등 소재의 독창화와 예술적 가치에 심혈을 쏟고 있다. 또한 외국신문에 기업광고를 내고, 영업사원을 활성화하며, 고객의 철저한 사후 A.S를 실시하여 기업의 발전에 노력하고 있다. 또 각 교회에서는 전례복 자수협회를 창단하여 취미 자수가나 재봉인의 교류에도 힘쓰며 전례복 생산과 자수공예를 배우려는 사람들에게 지원과 격려를 아끼지 않는다. 이와 같은 기업, 예술가, 교회의 노력은 3회사의 미래가 밝을 것임을 충분히 알려준다. 우리나라에서도 기업의 다양한 기술개발과 연구, 예술가의 종교미술의 참여, 교회의 관심을 통하여 세계적으로 유명한 전례복 생산지가 되기를 기대해 본다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF