• Title/Summary/Keyword: 3-Arm 형

Search Result 145, Processing Time 0.035 seconds

A Study on Apparatus of Smart Wearable for Mine Detection (스마트 웨어러블 지뢰탐지 장치 연구)

  • Kim, Chi-Wook;Koo, Kyong-Wan;Cha, Jae-Sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.263-267
    • /
    • 2015
  • current mine detector can't division the section if it is conducted and it needs too much labor force and time. in addition to, if the user don't move the head of sensor in regular speed or move it too fast, it is hard to detect a mine exactly. according to this, to improve the problem using one direction ultrasonic wave sensing signal, that is made up of human body antenna part, main micro processor unit part, smart glasses part, body equipped LCD monitor part, wireless data transmit part, belt type power supply part, black box type camera, Security Communication headset. the user can equip this at head, body, arm, waist and leg in removable type. so it is able to detect the powder in a 360-degree on(under) the ground whether it is metal or nonmetal and it can express the 2D or 3D film about distance, form and material of the mine. so the battle combats can avoid the mine and move fast. also, through the portable battery and twin self power supply system of the power supply part, combat troops can fight without extra recharge and we can monitoring the battle situation of distant place at the command center server on real-time. and then, it makes able to sharing the information of battle among battle combats one on one. as a result, the purpose of this study is researching a smart wearable mine detector which can establish a smart battle system as if the commander is in the site of the battle.

Development of Jacket Pattern for Muscular Men (근육형 남성용 재킷 패턴설계)

  • Jeong, Hye-Jin;Kim, So-Ra
    • Journal of Fashion Business
    • /
    • v.13 no.4
    • /
    • pp.137-153
    • /
    • 2009
  • Recently, young men have become more muscular as they become more interested in physical figure. However, most of these muscular men have fit problems regarding ready-made clothes. In view of this, this study aimed to develop a prototype jacket pattern for muscular men. For this study, five muscular men were selected to put on existing jacket pattern for wearing tests. The regression formula, in which muscular men body measures were adopted, was applied to unsuitable parts, especially the areas determined not to be appropriate in the evaluation of existing jacket pattern wearing tests. After the first and the second jacket pattern wearing tests, the final jacket pattern suitable for muscular men was developed. The results of the study were as follows: In order to make up for the problem of the loosening of the lapel area, due to the development of the chest muscle, the chest circumference line on the chest area of the pattern was cut to be 1.0cm wide; thus, the front length was modified with an increase. The wearing tests found that a wearers felt discomfort from the tight armhole area, so the armhole depth was set to be a little lower than that of ready-made clothes. A muscular men needs much more extra quantity in this area because the upper part of the back side is projected due to the greater development of the trapezius muscle and the deltoid than in average men. Hence, concerning the standard line for the length of the back interscye, ease of 1.0cm was added to the regression equation formula {(0.371${\times}$chest circumference+3.145)/2} in order to resolve the discomfort with the back area. Also, for the biacromion length, the upper arm protruded more than the shoulder point of the jacket because of the development of the deltoid and the upper arm muscle, and it was set to be wider than the actual shoulder. In order to solve the problem of discomfort from the narrow neck area during the wearing of a jacket owing to the development of the trapezius muscle, extra ease of 0.5cm was added to chest circumference/12-0.5cm in the existing jacket prototype to the width of back of the neck, and it was corrected to be chest circumference/12.

Development of a Moving Platform for a Upright Running Mobile Robot Based on an Inverted Pendulum Mechanism (역진자 기구에 기반한 직립주행 가능 이동로봇용 구동 플랫폼 개발)

  • Lee, Se-Han;Rhee, Sang-Yong
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.5
    • /
    • pp.570-576
    • /
    • 2012
  • In this research a moving platform for a mobile robot which can run with upright posture is proposed. It is able to stand with standing arms and run uprightly based on an inverted pendulum mechanism. Conventional mobile robots generally may equip 4 wheels or 3 wheels including a caster and have good statistic stability. They need a steering mechanism to choose which way to go since they have a square or rectangular configuration with multiple wheels. When a mobile robot meets a sharply perpendicular and narrow crossroad, it may need a special steering scheme such as going forward and backward repeatedly or it sometimes cannot even pass through the crossroad because of its size. The proposed moving platform for a mobile robot changes to a upright posture which has a small planar area and is able to pass through the crossroad. We propose a moving platform for a mobile robot with a inverted pendulum mechanism and standing arms which can make the mobile robot upright.

Area storage density of ideal 3-D holographic disk memories (이상적인 디스크형 3차원 홀로그래픽 메모리에서의 면적 저장밀도)

  • 장주석;신동학
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.1
    • /
    • pp.58-64
    • /
    • 2000
  • Assuming that the performance of holographic storage media is ideal, we estimate the area storage density of disk-type holographic memories, when the method of either angle multiplexing, or rotational multiplexing, or both are used. The area storage density is strongly dependent on the f numbers (ratio of focal length to diameter) of both the Fourier transform lens in the signal arm, denoted by $F/#_2$, and the angle range over which the reference beam is incident (or, the equivalent f number corresponding to the angle range denoted by $F/#_1$). The area storage density is largely independent of the pixel pitch of the spatial light modulator when the Fourier plane holograms are recorded, while it is sensitive to the pixel pitch when the image plane holograms are recorded. In general, to obtain high area storage density, the Fourier or at least near Fourier plane holograms rather than the image plane holograms should be recorded. In addition, when the thickness of the recording materials are less than approximately $500\mu\extrm{m}$, rotational multiplexing gives higher area storage densities than angle multiplexing does. To increase the storage density further, however, it is desirable to use both of the two multiplexing methods in combination.nation.

  • PDF

New Pre-charging Method for Modular Multi-level Converter Operated in Nearest Level Control Modulation (근사 계단 제어 변조로 동작하는 모듈형 멀티 레벨 컨버터를 위한 새로운 초기 충전 기법)

  • Kim, Kyo-Min;Kim, Jae-Hyuk;Kim, Do-Hyun;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1655-1663
    • /
    • 2016
  • Recently the researches on Modular Multi-level Converter (MMC) are being highlighted because high quality and efficient power transmission are key issues in the High Voltage Direct Current (HVDC) transmission system. This paper proposes an improved pre-charging method for the sub-module capacitors in MMC that operates in Nearest Level Control (NLC) modulation. The proposed method does not require additional circuits or Pulse Width Modulation (PWM) techniques. The feasibility of proposed method was verified through computer simulations for a scaled 3-phase 10kVA MMC with 12 sub-modules per each arm. Hardware experiments with a scaled prototype were performed in the lab to confirm the simulation results.

A STUDY ON THE RETENTIVE FORCE OF CIRCUMFERENTIAL CLASP (환상형 클래스프의 유지력에 관한 연구)

  • Lee, Jae-Sun;Vang, Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.5
    • /
    • pp.669-682
    • /
    • 1998
  • The purpose of this study was to compare the retentive force of cast half round circumferential clasps, cast round circumferential clasps and wrought wire clasps on three different depths of undercut(10G,20G.30G), and to determine the proper amount of undercut for cast round circumferential clasp. Three different lower second premolar crowns were cast and each of clasp was made. Each of clasp affixed to the different types of clasp. Their retentive forces were measured with universal testing machine. The results were as follows : 1. When the depth of undercut was same, the greatest retentive force was exerted by cast half round circumferential clasp, followed by cast round - 33 - circumferential clasp and wrought wire clasp. 2. The degree of variation amount of retentive force according to depth of undercut was greatest for cast round circumferential clasp. 3. Not only elastic deformation but also permanent deformation of the retentive arm was observed after insertion and removal of the clasp. The results of this study show that the retentive force of cast round circumferential clasp falls between those of cast half round circumferential clasp and wrought wire clasp, and suggest that a 20G undercut is suitable for ensuring an appropriate degree of the retentive force.

  • PDF

Effect of Conventional Transcutaneous Electrical Nerve Stimulation on Plasma $\beta-endorphin$ Level (고빈도-저강도 경피신경전기자극이 혈장 $\beta-endorphin$ 농도에 미치는 영향)

  • Lee Jae-Hyoung;Pack Chun-Seo;Kang Jung-Koo
    • The Journal of Korean Physical Therapy
    • /
    • v.5 no.1
    • /
    • pp.39-46
    • /
    • 1993
  • The purpose of this study was to examine the effect and $\beta-endorphin$ level as conventional transcutaneous electrical nerve stimulation (TENS) application on acupuncture paints. Twelve healthy adult male volunteers were participated in this study. The subjects were assigned to TENS group (n=6) and naloxone group (n=6). The LI 3 and M 10 meridian points of dominant arm were stimulated comfortably with 100 pps, $75{\mu}s$ conventional TENS for 30 minutes. Experimental pain threshold measurement and plasma $\beta-endorphin$ level were detected before and after conventional TENS application. Experimental pain threshold increased significantly (p<.01) but plasma $\beta-endorphin$ level was not change in TENS group. Experimental pain threshold increased significantly (p<.01) but plasma $\beta-endorphin$ level was not change in naloxone group. In this study, the conventional TENS induced analgesic effect, and plama $\beta-endorphin$ level was not increase concomitantly with analgesia. These results suggest that the $\beta-endorphin$ did not involved in conventional TENS analgesia.

  • PDF

Wheel &Track Hybrid Mobile Robot Platform and Mechanism for Optimal Navigation in Urban Terrain (도심지형 최적주행을 위한 휠.무한궤도 하이브리드형 모바일 로봇 플랫폼 및 메커니즘)

  • Kim, Yoon-Gu;Kim, Jin-Wook;Kwak, Jeong-Hwan;Hong, Dae-Han;Lee, Ki-Dong;An, Jin-Ung
    • The Journal of Korea Robotics Society
    • /
    • v.5 no.3
    • /
    • pp.270-277
    • /
    • 2010
  • Various robot platforms have been designed and developed to perform given tasks in a hazardous environment for the purpose of surveillance, reconnaissance, search and rescue, and etc. We have considered a terrain adaptive hybrid robot platform which is equipped with rapid navigation on flat floors and good performance on overcoming stairs or obstacles. Since our special consideration is posed to its flexibility for real application, we devised a design of a transformable robot structure which consists of an ordinary wheeled structure to navigate fast on flat floor and a variable tracked structure to climb stairs effectively. Especially, track arms installed in front side, rear side, and mid side are used for navigation mode transition between flatland navigation and stairs climbing. The mode transition is determined and implemented by adaptive driving mode control of mobile robot. The wheel and track hybrid mobile platform apparatus applied off-road driving mechanism for various professional service robots is verified through experiments for navigation performance in real and test-bed environment.

Development and performance evaluation of Machine Control Kit mountable to general excavators (일반 굴삭기 장착 가능한 머신 컨트롤 키트 개발 및 성능 평가)

  • K.S. Lee;K.S. Kim;J.B. Jeong;E.S. Pak;J.I. Koh;J.J. Park;S.H. Joo
    • Journal of Drive and Control
    • /
    • v.21 no.1
    • /
    • pp.31-37
    • /
    • 2024
  • In this study, to prevent accidents in underground facilities during excavation, we developed a Lv.3 automated control system that can be configured as an electronic control system without changing the existing hydraulic system in a general excavator and utilized digital map information of underground facilities. We aimed to develop a strategy to prevent accidents caused by operator error. To implement this, a real-time excavator bucket end position recognition and control system was developed through angle measurement of the boom, arm, and bucket using an electronic joystick, RTK-GPS, and angle sensors. In addition, excavators are large, machine-based equipment, and it is difficult to control overshoot due to inertia with feedback control using position recognition information of the bucket tip. Therefore, feed-forward control is used to calculate the moving speed of the bucket tip in real-time to determine the target position. We developed a technology that can converge and verified the performance of the developed system through actual vehicle installation and field tests.

Characteristics of the Anthropometry and Plasma Lipid Profiles of Patients with Simple and Combined Hypercholesterolemia (단순형과 혼합형 고콜레스테롤혈증 환자의 체위 및 혈장지질 특성)

  • 허영란;황금희;임현숙
    • Korean Journal of Community Nutrition
    • /
    • v.4 no.2
    • /
    • pp.186-193
    • /
    • 1999
  • Recent epidemiologic and clinical students have shown that plasma cholesterol and triglyceride levels are independent risk factors for coronary heart disease. However, there is not much data on the characteristics of anthropometry and lipid profiles of hypercholesterolemia patients with hypertiglyceridemia. In this study, 112 hypercholesterolemic subjects$(T.C{\ge}240mg/dl)$ were divided into two groups by their plasma triglyceride levels. We compared the anthropometric measurements and lipid profiles of the subjects between the two groups : the simples hypercholesterolemic group(SHC, TG<200mg/dl) and the combined hypercholesterolemic group$(CHC, TG{\ge}250mg/dl)$. The distribution of the subjects into the SHC and CHC groups was 36.6% and 47.3%, respectively. The frequency of the CHC patients decreased with age. The subjects in this group had higher weight, BMI, HWR, cricumferences of mid arm, waist, hip and thigh, and skinfold thicknesses of biceps and triceps than those of the SHC subjects. The difference of plasma total cholesterol level was mainly due to the difference of VLDL-C levels. These differences resulted in the CHC subjects having higher atherogenic indexes and T-C/HDL-C ratios than those of the SHC subjects. Also, the former had higher Apo-B and insulin levels than those the latter. However, blood pressure, fasting blood glucose and HDL-C levels were not significantly different between the two groups. These results suggest that hypercholesterolemic patients with hypertriglyceridemia have riskier lipid profiles for CHD than those of patients with normal triglyceridemia. They also indicate that CHC is closely associated with glucose resistance syndrome(obesity, hyperglycemia, hyperinsulinemia and hypertriglyceridemia), and more prevalent in young people.

  • PDF