• Title/Summary/Keyword: 3 phase boost converter

Search Result 112, Processing Time 0.026 seconds

Novel Modular 3-phase AC-DC Flyback Converter for Telecommunication

  • Choi Ju-Yeop;Lee J.P.;Kim T.Y.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.314-320
    • /
    • 2001
  • A novel mode of parallel operation of a modular 3-phase AC-DC flyback converter for power factor correction along with tight regulation was recently analyzed and presented. The advantage of the proposed converter does not require expensive high voltage and high current devices that are normally needed in popular boost type 3-phase converter. In this paper the detailed small signal analysis of the modular 3-phase AC-DC flyback converter is provided for control purposes and also experimental results are included to confirm the validity of the analysis.

  • PDF

A Study on the Variable Hysteresis Current Mode Control Method for Power Factor Improvement of the Single Phase Boost Converter (단상 부스터 콘버터의 입력역률 개선을 위한 가변 밴드폭 제어방식에 관한 연구)

  • 김철우;권순재;유동욱;박성준
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.3
    • /
    • pp.36-43
    • /
    • 1994
  • Many new electronic products are required to have a near unity power factor and a distortion free current input waveform. In this paper, single phase AC to DC Boost-Converter which is controlled with continuous conduction mode(CCM) is analyzed. Each parameter is determined for variable hysteresis current mode and real time simulation results showed high power factor possible. l(kW] boost converter was designed and constructed accordingly. Experimental results to load and parameter variations are well similar to the simulation results.

  • PDF

Dynamic Characteristics of DC-DC Converters Using Digital Filters

  • Kurokawa, Fujio;Okamatsu, Masashi;Ishibashi, Taku;Nishida, Yasuyuki
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.430-437
    • /
    • 2009
  • This paper presents the dynamic characteristics of buck and buck-boost dc-dc converters with digital filters. At first, the PID, the minimum phase FIR filter and the IIR filter controls are discussed in the buck dc-dc converter. Comparisons of the dynamic characteristics between the buck and buck-boost converters are then discussed. As a result, it is clarified that the superior dynamic characteristics are realized in the IIR filter method. In the buck converter, the undershoot is less than 2% and the transient time is less than 0.4ms. On the other hand, in the buck-boost converter, the undershoot is about 3%. However, the transient time is approximately over 4ms because the output capacitance is too large to suppress the output voltage ripple in this type of converter.

A Phase Shedding Control Algorithm to Increase Efficiency of 3-Phase Interleaved Boost Converter (3상 인터리브드 부스트 컨버터의 효율 상승을 위한 상 제어 알고리즘)

  • Lee, Kanghyun;Lee, Soon-Ryung;Baek, Seung-Ho;Lee, Jong-Young;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.391-392
    • /
    • 2016
  • A phase shedding control algorithm to increase efficiency of 3-Phase interleaved boost converter is proposed. Conventional interleaved converter has low efficiency under the light load condition. In this paper, the number of phase is controlled in accordance with the load condition to increase the light load efficiency. The validity of proposed phase control algorithm is verified by simulation results based on measured efficiency.

  • PDF

The Controller Design of Bi-directional DC-DC Converter for a Fuel Cell Energy Storage System (연료전지용 커패시터 충.방전을 위한 양방향 DC-DC 컨버터 제어기 설계)

  • Kim, Seung-Min;Yang, Seung-Dae;Choi, Ju-Yeop;An, Jin-Woong;Lee, Sang-Chul;Lee, Dong-Ha
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.222-228
    • /
    • 2012
  • This paper presents a design and simulation of bi-directional DC/DC boost converter for a fuel cell system. In this paper, we analyze the equivalent model of both a boost converter and a buck converter. Also we propose the controller of bi-directional DC-DC converter, which has buck mode of charging a capacitor and boost mode of discharging a capacitor. In order to design a controller, we draw bode plots of the control-to-output transfer function using specific parameters and incorporate 3pole-2zero compensator in a closed loop. As a result, it has increased PM(Phase Margin) for better dynamic performance. The proposed bi-directional DC-DC converter's 3pole-2zero compensation method has been verified with computer simulation and simulation results obtained demonstrates the validity of the proposed control scheme.

  • PDF

Analysis of Step-up AC/DC Converter (승압형 AC/DC 전력 변환기의 해석)

  • Park, S.Y.;Park, I.G.;Kang, Y.S.;Park, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.340-343
    • /
    • 1990
  • Recently, Power Electronics system increase makes harmonics and low input power factor problem. In this paper present new analysis method of PWM Boost AC/DC Converter. This PWM AC/DC Converter is capability of unity power factor, control of DC side voltage level, generation, and near sinusoidal current in 3-phase line. The control of this type of converter is widely discussed. And this paper propose new phase convert function and analysis in steady state of system to obtain amplitude and phaser of switching function. This switching function is general solution and it can use in high power approach. And this control method show the clear meaning of control variable. This paper propose new analysis method of Boost AC/DC Converter of steady state and 3-phase 2KW experimental system show its validity.

  • PDF

A Study on Excitation System for Synchronous Generator Using Two State Three Phase PWM AC/DC Converter (2단 3상 PWM AC/DC 컨버터를 이용한 동기발전기 여자제어시스템)

  • Lee, Sang-Hun;Lee, Dong-Hee;Ahn, Jin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.96-106
    • /
    • 2007
  • The terminal voltage of a synchronous generator is maintained by the field current control of excitation system. Generally AC/DC converter which is component of AVR(Automatic Voltage Regulator) system for excitation current control is connected to diode rectifier and DC/DC converter system. In the case of diode rectifier system of phase controlled converter as AC/DC converter have low power factor and harmonics of lower order in the line current. In this paper, two stage three phase PWM AC/DC converter is studied to solve these problems. The characteristics of a proposed converter reduces the harmonics and reactive power of the distribution line and has fast dynamic response in transient period using boost converter and current control mode buck converts. The proposed method is verified by the computer simulation and experimental results in prototype generation system.

Steady-State Analysis of N-phase Interleaved Boost Converter (N상 Interleaved Boost 컨버터의 정상상태 특성 해석)

  • 박종규;장성동;신휘범;김흥근
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.3
    • /
    • pp.196-205
    • /
    • 2004
  • Although many papers about the interleaved boost converter(IBC) have been published, there are, unfortunately, no analytical and rigorous expressions for steady-state operation of the N-phase IBC. To understand the operating characteristics of the N-phase IBC, the averaged state equation and the general steady-state solutions are derived in this paper. The general expressions of the current unbalance due to the parameter mismatch, the inductor and input current ripples, and the output voltage ripple are also presented. Through the analytical expressions presented, the steady-state characteristics of the N-phase IBC are analyzed theoretically and verified experimentally.

The Design of Digital Controller for Three-Phase Boost Converter using DSP (DSP를 이용한 3상 부스트 컨버터의 디지털 제어기 설계)

  • Cho, Seong-Min;Kim, Beung-Jin;Cho, Heung-Gi;Jeon, Hee-Jong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.11
    • /
    • pp.757-762
    • /
    • 2000
  • This paper presents a digital controller for three-phase Boost Converter. Generally, the conventional Space-Vector Pulse Width Modulation (SVPWM) have complex computation. Thereby, it should be implemented with high performance processor. In order to reduce calculation burden of the conventional SVPWM, digital controller which has a simplified SVPWM algorithm is designed in this study. A proposed digital controller consists of fuzzy pwm controller and prediction controller. In simulations and experiments, the proposed digital controller is validated.

  • PDF

Characteristic Analysis of Three Phase PWM Boost AC-AC Converter Using Circuit DQ Transformation (회로 DQ 변환을 이용한 3상 PWM Boost AC-AC 컨버터의 특성해석)

  • 최남섭
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.7
    • /
    • pp.1514-1519
    • /
    • 2003
  • This paper presents modeling and analysis of static and dynamic characteristics in three phase PWM Boost AC-AC converter used for input voltage sag compensation of custom power. Especially, using circuit DQ transformation technique, an equivalent circuit in fundamental frequency domain is obtained which has all the system characteristics. Moreover, voltage gain and input power factor is analytically induced and linearized state equation at the specific operating point is given. Finally, PSIM simulation results show the validity of the Nosed modelling and analyses.