• Title/Summary/Keyword: 3 phase

Search Result 21,012, Processing Time 0.044 seconds

Image Authentication Using Only Partial Phase Information from a Double-Random-Phase-Encrypted Image in the Fresnel Domain

  • Zheng, Jiecai;Li, Xueqing
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.3
    • /
    • pp.241-247
    • /
    • 2015
  • The double-random phase encryption (DRPE) algorithm is a robust technique for image encryption, due to its high speed and encoding a primary image to stationary white noise. Recently it was reported that DRPE in the Fresnel domain can achieve a better avalanche effect than that in Fourier domain, which means DRPE in the Fresnel domain is much safer, to some extent. Consequently, a method based on DRPE in the Fresnel domain would be a good choice. In this paper we present an image-authentication method which uses only partial phase information from a double-random-phase-encrypted image in the Fresnel domain. In this method, only part of the phase information of an image encrypted with DRPE in the Fresnel domain needs to be kept, while other information like amplitude values can be eliminated. Then, with the correct phase keys (we do not consider wavelength and distance as keys here) and a nonlinear correlation algorithm, the encrypted image can be authenticated. Experimental results demonstrate that the encrypted images can be successfully authenticated with this partial phase plus nonlinear correlation technique.

A Two-Phase Flow Accelerated Corrosion Study on Water Wall Tube of Coal-Fired Boiler According to Flexible Operation (유연운전에 따른 석탄화력보일러 수계통 튜브에서의 이상 유동가속부식(Two-Phase Flow Accelerated Corrosion) 고찰)

  • Sang-Ho Kim;Seung-Min Lee;Jae-Hong Lee
    • Corrosion Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.246-254
    • /
    • 2024
  • Recently, coal-fired power plants are experiencing many problems that they have never experienced before due to an increase in flexible operation. In particular, a two-phase flow accelerated corrosion on water wall tubes in a boiler has not been detected overseas or domestically. There is no response plan to deal with such corrosion problem either. However, oxide film damage and tube material corrosion due to a two-phase flow accelerated corrosion are being discovered on water wall boiler tubes of domestic coal-fired power plants recently. If this situation is severe, it can cause enormous damage such as tube rupture. Therefore, in this paper, in order to prepare a response plan for a two-phase flow accelerated corrosion on water wall tubes in the future, differences between a two-phase flow accelerated corrosion and a single-phase flow accelerated corrosion were investigated and an example of discovery of a two-phase flow accelerated corrosion on water wall tubes was presented.

Development of a one-dimensional system code for the analysis of downward air-water two-phase flow in large vertical pipes

  • Donkoan Hwang;Soon Ho Kang;Nakjun Choi;HangJin Jo
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.19-33
    • /
    • 2024
  • In nuclear thermal-hydraulic system codes, most correlations used for vertical pipes, under downward two-phase flow, have been developed considering small pipes or pool systems. This suggests that there could be uncertainties in applying the correlations to accident scenarios involving large vertical pipes owing to the difference in the characteristics of two-phase flows, or flow conditions, between large and small pipes. In this study, we modified the Multi-dimensional Analysis of Reactor Safety KINS Standard (MARS-KS) code using correlations, such as the drift-flux model and two-phase multiplier, developed in a plant-scale air-inflow experiment conducted for a pipe of diameter 600 mm under downward two-phase flow. The results were then analyzed and compared with those based on previous correlations developed for small pipes and pool conditions. The modified code indicated a good estimation performance in two plant-scale experiments with large pipes. For the siphon-breaking experiment, the maximum errors in water flow for modified and original codes were 2.2% and 30.3%, respectively. For the air-inflow accident experiment, the original code could not predict the trend of frictional pressure gradient in two-phase flow as / increased, while the modified MARS-KS code showed a good estimation performance of the gradient with maximum error of 3.5%.

Influence of Various Soil CharacteriBtics in GinBeng Field or the Growth and the Yield of Ginseng (Panax gisoseng C. A. Meyer) (인삼전지의 토양특성이 인삼의 생육및 수량에 미치는 영향에 관한 연구)

  • 이일호;육창수;한강완;박찬수;박현석;남기열
    • Journal of Ginseng Research
    • /
    • v.4 no.2
    • /
    • pp.175-185
    • /
    • 1980
  • A study was made to clarify the topographical. and Physical characteristics of ginseng field in terms of soil science and to find the relationship between soil characteristics and ginseng growth, as well as yield of ginseng roots Forty nine farmer's red ginseng field of ginseng growing area were chosen for this study and investigated for two years. The results obtained were as follow. 1. Ginseng fie1ds with high yield which represent the more than 1.8kg of ginseng root per 3.2m2 were found in soil series of Bancheon, Yeongog, Weongog, etc. whose texture were the clay loam to clay soil. On the other hand, ginseng field with low yield were observed in soil series of seogto whose texture was loamy soil with high content of gravels. 2 Soil of ginseng field with high yield had higher content of clay. silt soil moisture and soil pore as compared with soils of low yields. These soil characteristics were positively correlated with stem length stem diameter and root weight of ginseng plsnt and negatively correlated with rate of missing plant 3. The adequate ranges of soil 3 phase from high yield ginseng field were 40 to 50% of solid Phase, 22 to 35% of liquid phase, 25 to 35% of gaseous phase in top soil and 45 to 55% of solid phase. 28 to 30% of liquid phase. 15 to 20% of gaseous phase in subsoil respectively.

  • PDF

Counter-Current Air-Water Flow in Narrow Rectangular Channels With Offset Strip Fins

  • Kim, Byong-Joo;Sohn, Byung-Hu;Koo, Kee-Kahb
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.429-439
    • /
    • 2003
  • Counter-current two-phase flows of air- water in narrow rectangular channels with offset strip fins have been experimentally investigated in a 760 mm long and 100 mm wide test section with 3.0 and 5.0 mm gap widths. The two-phase flow regime, channel-average void fractions and two-phase pressure gradients were studied. Flow regime transition occurred at lower superficial velocities of air than in the channels without fins. In the bubbly and slug flow regimes, elongated bubbles rose along the subchannel formed by fins without lateral movement. The critical void fraction for the bubbly-to-slug transition was about 0.14 for the 3 mm gap channel and 0.2 for the 5 mm gap channel. respectively. Channel-average void fractions in the channels with fins were almost the same as those in the channels without fins. Void fractions increased as the gap width increased, especially at high superficial velocity of air. The presence of fins enhanced the two-phase distribution parameter significantly in the slug flow, where the effect of gap width was almost negligible. Superficial velocity of air dominated the two-phase pressure gradients. Liquid superficial velocity and channel gap width has only a minor effect on the pressure gradients.

CFD Investigation of Rocket Nozzle Plume for Flame Deflector Preliminary Analysis (화염유도로 예비 해석을 위한 로켓노즐 플룸의 CFD 해석 검증)

  • Jun, Doo-Sung;Kim, Jae-Woo;Kim, Jong-Rok;Kim, Woo-Kyeom;Kim, Seung-Cheol;Moon, Hee-Jang
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.313-316
    • /
    • 2011
  • This paper investigates CFD investigation on single phase supersonic nozzle flow and 2-phase subson ic flow prior to rocket nozzle supersonic 2-phase flow with water injection within the flame deflector. Numerical results of supersonic nozzle single phase flow showed no notable unrealistic behavior as it captures the usual shock cell structures. Three-dimensional 2-phase flow analysis has also been performed to verify whether the approach can grab the droplet behavior during cooling by water injection. It is expected these basic studies will enhance the cooling problem analysis of supersonic 2-phase rocket plume in the future.

  • PDF

Powder Preparation by Hydroxide Coprecipitation and Phase Development of Pb0.97La0.02(Zr0.64Sn0.25Ti0.11)O3 Ceramics

  • Lee, Joon-Hyung;Chiang, Yet-Ming
    • The Korean Journal of Ceramics
    • /
    • v.4 no.3
    • /
    • pp.260-267
    • /
    • 1998
  • A homogeneous and stoichimetric fine powder of the ferroelectric $Pb_[0.97}La_{0.02}(Zr_{0.64}Sn_{0.25}Ti_{0.11})O_3$ (PLZST) has been prepared by the hydroxide coprecipitation method. Studies on the crystallization behavior of precursor as a function of temperature by X-ray powder diffraction and transmission electron microscopy technique were consistent with the formation of the pyrochlore phase from amorphous, initially at low temperatures around 500~$550^{\circ}C$. Further heat treatment up to $750^{\circ}C$ resulted in development of the perovskite phase with no significant pyrochlore crystallite growth. At intermediate temperatures the precursor yields a fine mixture of pyrochlore and perovskite phases. When the pyrochlore phase was heat teated in air, slight weight increase was observed in the temperature range of 300~$700^{\circ}C$, which is thought to be caused from oxygen absorption. In argon atmosphere, weight increase was not observed. On the other hand, weight loss began to occur near $700^{\circ}C$, with giving off mostly CO2 gas. This implies that the pyrochlore phase seems to be crystallorgraphycally and thermodynamically metastable. An apparent activation energy of 53.9 ㎉/mol was estimated for the pyrochlore-perovskite phase transformation.

  • PDF

Spinodal Phase Separation and Isothermal Crystallization Behavior in Blends of VDF/TrFE(75/25) Copolymer and Poly(1,4-butylene adipate) (I) -Spinodal Phase Separation Behavior-

  • Kim, Kap Jin;Kyu, Thein
    • Fibers and Polymers
    • /
    • v.4 no.4
    • /
    • pp.188-194
    • /
    • 2003
  • Phase behavior and spinodal phase separation kinetics in binary blends of a random copolymer of vinylidene fluoride and trifluoroethylene (75/25) [P(VDF/TrFE)] and poly(l,4-butylene adipate) (PBA) have been investigated by means of optical microscopic observation and time-resolved light scattering. The blends exhibited a typical lower critical solution temperature (LCST)∼${34}^{\circ}C$ above the melting temperature of the P(VDF/TrFE) crystals over the entire blend composition range. P(VDF/TrFE) and PBA were totally miscible in the temperature gap between the melting point of P(VDF/TrFE) and the LCST. Temperature jump experiments of the 3/7 P(VDF/TrFE)/PBA blend were carried out on a light-scattering apparatus from a single-phase melt state (${180}^{\circ}C$) to a two-phase region (205∼${215}^{\circ}C$). Since the late stage of spinodal decomposition (SD) is prevalent in the 3/7 blend, SD was analyzed using a power law scheme. Self-similarity was preserved well in the late stage of SD in the 3/7 blend.

A Switching Method for Minimizing the Over Current in Transient Response of 3-phase Interleaved Bidirectional DC-DC Converter with Frequency Modulation (주파수 변조 방식 3상 인터리브드 양방향 DC-DC 컨버터의 과도상태 과전류를 최소화하기 위한 스위칭 기법)

  • Bae, Jongwoo;Jeong, Hyesoo;Jung, Jae-Hun;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.6
    • /
    • pp.530-537
    • /
    • 2016
  • This work deals with a switching method for minimizing overcurrent in a three-phase interleaved bidirectional DC-DC converter with frequency modulation. Generally, a three-phase interleaved DC-DC converter is used to reduce a current ripple component. The combined operation of three-phase and two-phase converters can significantly reduce the ripple component. However, the conventional PWM method cannot solve severe overcurrent during phase transfer or frequency variation for power control. To overcome this problem, this work proposes a new PWM switching method. A 3 kW DC-DC power converter is designed and implemented, and the converter is operated in discontinuous current mode with varying switching frequencies for power control. Simulation and experimental results show the validity of the proposed switching method. The proposed switching method can be widely used in the field of current ripple reduction for three-phase interleaved bidirectional DC-DC converters.

Three Phase Current Reconstruction Method of Three Shunt Sensing 3-Phase Inverter by Predictive Current Technique (예측 전류 기법을 적용한 3-션트 전류검출 3상 인버터의 전류 복원 방법)

  • Choo, Kyoung-Min;Hong, Sung-Woo;Jang, Young-Hee;Won, Il-Kuen;Kim, Do-Yun;Wo, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.2
    • /
    • pp.175-180
    • /
    • 2017
  • The measurement of three-phase current is important to control the instantaneous torque of a interior permanent magnet synchronous motor(IPMSM) using a three-phase inverter. Therefore, shunt resistors are used in low-cost motor-driving systems to measure three-phase current instead of additional current sensors that are too expensive for these systems. However, in certain regions of a space vector plane, shunt resistors cannot reconstruct three-phase current in high-speed driving mode. In this paper, predictive current control is used to compensate for the three-phase current in those regions, which results in a reduction of current ripple in a three-shunt sensing inverter(TSSI) and torque ripple in IPMSM.