• Title/Summary/Keyword: 3 inch

Search Result 553, Processing Time 0.024 seconds

Analysis of offshore pipeline laid on 3D seabed configuration by Abaqus

  • Moghaddam, Ali Shaghaghi;Mohammadnia, Saeid;Sagharichiha, Mohammad
    • Ocean Systems Engineering
    • /
    • v.5 no.1
    • /
    • pp.31-40
    • /
    • 2015
  • Three dimensional (3D) non-linear finite element analysis of offshore pipeline is investigated in this work with the help of general purpose software Abaqus. The general algorithm for the finite element approach is introduced. The 3D seabed mesh, limited to a corridor along the pipeline, is extracted from survey data via Fledermous software. Moreover soil bearing capacity and coefficient of frictions, obtained from the field survey report, and are introduced into the finite element model through the interaction module. For a case of study, a 32inch pipeline with API 5L X65 material grade subjected to high pressure and high temperature loading is investigated in more details.

Numerical Prediction of the Temperature Field in Hard disk Drive (하드디스크 드라이브 내부의 온도장 예측에 관한 연구)

  • Lee, Y.D.;Lee, Jae-Heon;Kim, K S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.3
    • /
    • pp.233-241
    • /
    • 1992
  • Temperature distributions in a 3.5 inch hard disk drive including disk surface and internal air have been simulated numerically. Solutions were obtained from fifteen cases regarding three power consumption rates and five ambient conditions. As a result, the velocity of cooling air should be maintained greater than ㏐/s when the power consumption reached 3W in the disk drive. A correlation equation was proposed to predict the temperature field of disk surface and caseing surface.

  • PDF

Flow-Induced Vibration Test in the Preheater Region of a Steam Generator Tube Bundle

  • Kim, Beom-Shig;Hwang, Jong-Keun
    • Nuclear Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.85-91
    • /
    • 1997
  • Cross-flow existing in a shell-and-tube steam generator can cause a tube to vibrate. There are four regions subjected to cross-flow in Yonggwang units 3 and 4 (YGN 3 and 4) steam generators, which are of the same design as the steam generators for Palo Verde nuclear power plant Palo Verde units 1 and 2 steam generators have experienced localized oar at the comers of the cold side recirculating fluid inlet regions. A number of design modifications were made to preclude tube failure in specific regions of YGN 3 and 4 steam generators. Therefore, flow induced vibration experiments were done to determine the vibration magnitude of tubes in the economizer tube free lane region. The objective of this experiment is to demonstrate that the tube displacement is less than 0.01 inch rms at 100% of full power flow and to quantify the remaining design margin at 120ft and 140% of full power flow.

  • PDF

De-NOX evaluation of SCR catalysts adding vanadium-graphene nanocomposite (바나듐 담지된 그래핀 나노복합체를 첨가한 SCR 촉매의 제조 및 활성 평가)

  • Jeong, Bora;Lee, Heesoo;Kim, Eok-Soo;Kim, HongDae
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.25 no.6
    • /
    • pp.252-256
    • /
    • 2015
  • Nitrogen oxides ($NO_X$) was emitted from flue gas of stationary sources and exhaust gas of mobile sources, can leads to various environments problems. Selective Catalysts Reduction (SCR) is the most effective $NO_X$ removal system. Commercial $V_2O_5-WO_3/TiO_2$ catalysts, usually containing $V_2O_5$ 0.5~3 wt%, $WO_3$ 5~10 wt%, and $V_2O_5$ is active in the reduction of $NO_X$ but also in the desired oxidation of $SO_2$ to $SO_3$. To reduce the amount of vanadium, using graphene matrix supported vanadium to synthesize nanocomposite. Then, we fabricated to 1 inch honeycomb type of SCR catalysts adding graphene-vanadium nanocomposite. The chemical-physical characteristics and the catalytic activity were performed by XRD, XRF, BET and Micro-Reactor (MR). As a result, the De-NOX performance was showed, similar to the commercial catalyst activity as 77.8 % and using nanocomposite catalyst as 77.1 % at $350^{\circ}C$.

Studies on Fabrication and Characteristics of $Al_{0.3}Ga_0.7N/GaN$ Heterojunction Field Effect Transistors for High-Voltage and High-Power Applications (고전압과 고전력 응용을 위한 $Al_{0.3}Ga_0.7N/GaN$ 이종접합 전계효과 트랜지스터의 제작 및 특성에 관한 연구)

  • Kim, Jong-Wook;Lee, Jae-Seung;Kim, Chang-Suk;Jeong, Doo-Chan;Lee, Jae-Hak;Shin, Jin-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.8
    • /
    • pp.13-19
    • /
    • 2001
  • We report on the fabrication and characterization of $Al_{0.3}Ga_{0.7}N$ HFETs with different barrier layer thickness which were grown using plasma-assisted molecular beam epitaxy (PAMBE). The barrier thickness of $Al_{0.3}Ga_{0.7}N$/GaN HFETs could be optimized in order to maximize 2 dimensional electron gas induced by piezoelectric effect without the relaxation of $Al_{0.3}Ga_{0.7}N$ layer. $Al_{0.3}Ga_{0.7}N$/GaN (20 nm/2 mm) HFET with 0.6 ${\mu}m$-long and 34 ${\mu}m$-wide gate shows saturated current density ($V_{gs}=1\;V$) of 1.155 A/mm and transconductance of 250 ms/mm, respectively. From high frequency measurement, the fabricated $Al_{0.3}Ga_{0.7}N$/GaN HFETs showed $F_t=13$ GHz and $F_{max}=48$ GHz, respectively. The uniformity of less than 5% could be obtained over the 2 inch wafer. In addition to the optimization of epi-layer structure, the relation between breakdown voltage and high frequency characteristics has been examined.

  • PDF

A FEM study about the initial stress distribution on canine altered by the application point of preangulated TMA T-loop spring (Preangulated TMA T-loop spring의 적용 위치 변화에 따른 견치의 초기 응력 분포에 대한 유한 요소법적 연구)

  • Kim, Jung-Min;Cha, Kyung-Suk;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.29 no.5 s.76
    • /
    • pp.521-534
    • /
    • 1999
  • The purpose of this study was to find the difference of stress distribution on canine altered by the application point of preangulated T-loop spring. For this study, the finite element models of upper left canine, upper left second premolar and upper left first molar were made. Also, the finite element models of $0.017{\times}0.025$ inch preangulated, preactivated T-loop spring and $0.018{\times}0.025$ inch stainless steel wire were made. Three types of T-loop spring were made . the middle of activated T-loop is positioned in accordance with the middle position of distance of bracket position of both the canine and first molar, 2mm anterior, 2mm posterior. We compared the forces and the distribution of stress that were generated by the difference of position of T-loop spring. The results were as follows. 1. All of the 3 types of T-loop spring showed the similar retraction forces. 2. All showed the similar amount & pattern of stress distribution. 3. The centers of rotation of canine in 3 types of T-loop spring were same and were positioned between C and D plane. 4. The canine showed the intrusive force by 2mm anterior positioned T-loop spring, but the extrusive force by 2mm posterior positioned T-loop suing. Neverthless, because of the small amount of the forces, the effect of vertical force was not significant.

  • PDF

A Study on the Utilization of 4K/UHD Camera with 2/3" Sensor : Focused on Application of HD Lens (2/3" 센서를 활용한 4K/UHD 카메라 활용방안 연구 : HD 렌즈 활용을 중심으로)

  • Kim, Sang-il;Park, Sung-chul;Kwon, Soon-chul;Lee, Seung-hyun;Hamacher, Alaric
    • Journal of Digital Contents Society
    • /
    • v.16 no.2
    • /
    • pp.227-234
    • /
    • 2015
  • Recently, there is more and more demand on broadcasting display environment that provides a sense of realism basically with high quality and high definition as in UHDTV, so various kinds of 4K cameras have been released. Super 35mm sensor 4K/UHD cameras being generally used can be usefully applied to the single camera-based system such as advertisements, dramas, nature documentaries, and culture programs. However, in the multicamera-based system such as entertaining programs, sports, and concerts, relay broadcasting may face limitations as there are restrictions of close-up or tight shots according to the distance. Besides, 4K lenses are not enough compared with the previous HD lenses' group, so there are limitations in camera photographing shots that have been realized in HD filming. Therefore, to complement this, the use of 2/3 inch sensor 4K/UHD cameras is being demanded, and it is also needed to use various lenses' groups to produce UHD image contents. Accordingly, this study used Grass Valley's LDX 4K/UHD camera to analyze its applicability based on the picture quality test at the use of HD lenses in 2/3 sensors and also the possibility of its efficient application.

TOMOGRAPHIC AND CEPHALOMETRIC STUDY OF CONDYLAR POSITION IN TEMPOROMANDIBULAR DISORDER PATIENTS (악관절 기능장애 환자의 하악과두 위치에 관한 단층 및 두부방사선 계측학적 연구)

  • Kim Min Sook;Ko Kwang Jun
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.2
    • /
    • pp.299-313
    • /
    • 1990
  • The author analysed tomographic and cephalometric radiographs of 82 temporomandibular joints from 41 symptomatic patients and 40 temporomandibular joints from 20 asymptomatic young adults. The results were as follows; 1. The mean condylar angulation in control group and patient group was 21.72±6.48° 20.13±9.14° respectively and there was no significant difference between two groups. 2. The mean depth of cut was 6.63±0.38㎝ in control group and 6.57±0.46㎝ in patient group. 3. Mean height and width of condylar head were 6.66±1.83㎜, 12.42±0.49㎜ in control group and 6.22±1.36㎜, 11.93±l.92㎜ in patient group. 4. The mean height of articular fossa was 10.20±2.04㎜ in control group and 9.89±1.98㎜ in patient group. The mean width of articular fossa was 21.08±2.08㎜ in control group and 21.24±3.03㎜ in patient group. 5. In centric occlusion the superior joint space was largest (4.15±0.93㎜), followed by the posterior joint space (2.99±0.97㎜) and the anterior joint space (2.70±0.73㎜) in control group. The superior joint space (3.47±1.31㎜) and posterior joint space (3.47±7.07㎜) were same in patient group. There was significant difference in left superior joint spaces between two groups (p<0.05). 6. The condylar position in articular fossa was displaced anteroinferiorly (0.99±3.65㎜ anteriorly, 1.75±1.01㎜ inferiorly) in control group and posteroinferiorly (3.20±4.69㎜ posteriorly, 1.25±1.87㎜ inferiorly) in patient group with 1 inch opening. In maximum opening, it was displaced anteroinferiorly (6.09±3.55㎜ anteriorly, 1.38±2.47㎜ inferiorly) in control group and anteroinferiorly (1.70±5.96㎜ anteriorly, 1.37±1.85㎜ inferiorly) in patient group. There was significant difference in anteroposterior position of both condyles with 1 inch opening and maximum opening between two groups (p<0.01). 7. The mean inclination of upper central incisor and the posterior inclination of articular eminence in control group was 65.60±6.04° 58.88±9.18° in control group, and 67.14±8.41°, 59.70±9.08° in patient group respectively. There was no significant correlation between two groups.

  • PDF

An experimental study on the cytotoxicity of orthodontic wires (교정용 호선의 세포독성에 관한 실험적 연구)

  • Lim, Yong-Kyu;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.26 no.5 s.58
    • /
    • pp.591-599
    • /
    • 1996
  • This study was undertaken to investigate the cytotoxicity of orthodontic wires after doing various treatments to the wires. 018x025 inch Stainless steel(A) and Co-Cr(B) wires were used and each of them were divided into 4 groups. A-1 and B-1 groups were as received state, and A-2 and B-2 groups were heat treated. A-3 and B-3 groups were electropolished after heat treatment, and A-4 and B-4 groups were soldered with Ag-solder. Each group had 3 wires and these were sterilized with Ethylene Oxide gas. We used human gingival fibroblast cell culture and agar overlay technique to investigate the cytotoxicity of each group of wires. The cytotoxicity of wire was assessed using reaction index (zone index/lysis index). The findings of this study were as follows. 1. Both of the stainless steel wire and Co-Cr wire showed no cytotoxicity in as received state. 2. Heat treatment or electropolishing of the wires had no effect on the cytotoxicity of the wires 3. Soldered stainless steel wires showed a little wider zone of discoloration than soldered Co-Cr wires, but the zone index and cytotoxicity(reaction index) was not different. 4. Soldered wires showed moderate cytotoxicity in both of the wires.

  • PDF

Nanoinjection Molding Process with Passive Heating System for Patterned Magnetic Media (패턴드 미디어 제작을 위한 나노 사출성형 공정에 관한 연구)

  • Choi, Eui-Sun;Lee, Nam-Seok;Han, Jeong-Won;Kim, Young-Joo;Kang, Shin-Ill
    • Transactions of the Society of Information Storage Systems
    • /
    • v.3 no.3
    • /
    • pp.149-153
    • /
    • 2007
  • Perpendicular patterned magnetic media have been regarded as a prime candidate to achieve an ultra-high magnetic recording density of over 1 Tera-bits/$inch^2$. Patterned magnetic media with nanoscale patterns have been fabricated using various nanopatterning technologies. We focused on the two technical issues of nanoinjection molding technology. Firstly, we have investigated a cost-effective method to fabricate metallic stamps. Secondly, we focused on the analysis of nanoinjection molding with passive heating, where the replication of 50 nm nanopillar arrays was successful. The effect of the thermal insulation layer on the replication quality was examined by analytical and experimental methods. Finally, we deposited a magnetic layer on a injection molded nanopillars and measured. Our methodology can provide cost-effective mass-production for patterned magnetic media.

  • PDF