• Title/Summary/Keyword: 3 Tesla

Search Result 206, Processing Time 0.021 seconds

A Robust Pair-wise Key Agreement Scheme based on Multi-hop Clustering Sensor Network Environments (멀티홉 클러스터 센서 네트워크 환경 기반에서 견고한 키 교환)

  • Han, Seung-Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.3
    • /
    • pp.251-260
    • /
    • 2011
  • In this paper, we proposed a scheme that it safely exchanges encrypted keys without Trust Third Party (TTP) and Pre-distributing keys in multi-hop clustering sensor networks. Existing research assume that it exists a TTP or already it was pre-distributed a encrypted key between nodes. However, existing methods are not sufficient for USN environment without infrastructure. Some existing studies using a random number Diffie-Hellman algorithm to solve the problem. but the method was vulnerable to Replay and Man-in-the-middle attack from the malicious nodes. Therefore, authentication problem between nodes is solved by adding a ��TESLA. In this paper, we propose a modified Diffie-Hellman algorithm that it is safe, lightweight, and robust pair-wise agreement algorithm by adding One Time Password (OTP) with timestamp. Lastly, authentication, confidentiality, integrity, non-impersonation, backward secrecy, and forward secrecy to verify that it is safe.

A Robust Pair-wise Key Agreement Scheme without Trusted Third Party and Pre-distributing Keys for MANET Environments (MANET에서 제 3 신뢰기관(TTP)과 사전 키 분배가 필요 없는 강인한 키 교환 방식)

  • Han, Seung-Jin;Choi, Jun-Hyeog
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.5
    • /
    • pp.229-236
    • /
    • 2008
  • In this paper, re proposed scheme that it safely exchange encrypted keys without Trust Third Party(TTP) and Pre-distributing keys in ubiquitous environments. Existing paper assume that exist a TTP or already pre-distributed encrypted keys between nodes. However, there methods are not sufficient for wireless environments without infrastructure. Some existing paper try to use the Diffie-Hellman algorithm for the problem, but it is vulnerable to Replay and Man-in-the middle attack from the malicious nodes. Therefore, Authentication problem between nodes is solved by modified the Diffie-Hellman algorithm using ${\mu}TESLA$. We propose safe, lightweight, and robust pair-wise agreement algorithm adding. One Time Password(OTP) using timestamp to modified the Diffie-Hellman in ubiquitous environments, and verify a safety about proposed algorithm.

  • PDF

Development of 1.0 Tesla Compact MRI System (1.0 Tesla 자기 공명 진단 장치의 개발)

  • Lee, H.K.;Oh, C.H.;Ahn, C.B.;Chang, Y.H.;Shin, D.W.;Lee, K.N.;Jang, K.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.129-134
    • /
    • 1996
  • 1차 년도 G-7 개발 과제로 수행된 자기 공명 진단 장치 (Magnetic Resonance Imaging System)의 개발 내용을 간략히 소개하였다. 성공적인 IT Compact 자기 공명 진단 장치의 완성을 위해 일차적으로 (1)RF (고주파), Gradient(경사 자계), Spectrometer 등의 Hard-ware 관련 MRI 핵심부분, (2) RF, Gradient, Spectrometer, Magnet 등의 각 Sub-system을 연결, 조합, 조정하여 하나의 체계적인 시스템으로 통합하고 운영하는 과정(System Integration), (3)사용자와 시스템을 연결하는 User Interface, Data Base Management, Real time 운영 SW 등과 (4)임상에 적용하여 구체적인 성능과 효용성을 확인하는 기술 등에 대하여 집중 연구하였다. 개발 방법은 (1)지난 16년간 국내에 축적 된 연구 개발 인력들을 최대한 활용하고 (2)연구 개발을 국제화 시켜 필요한 경우 부분별로 개발 인력을 해외에서 보완하고 (3)소수 정예 전문 인력 주의와 요소 기술 또는 중요 부품을 경쟁성 검토 후 필요 시 Out-sourcing 활용으로 최저의 비용으로 개발 기간을 최소화 하는 데 두었다. 개발된 1.0Tesla자기 공명 영상 장치는 미국 물리 학회에서 규격화한 Phantom및 임상 적용을 통하여 서울대 의대 연구 팀과 지속적으로 성능을 평가해 왔다. 개발된 시스템의 해상도는 $256{\times}256$ head 영상에서 1mm 이 하의 해상도를 가짐을 resolution phantom 을 통하여 확인할 수 있었고, $512{\times}512$ 영상에서 는 약 0.5 mm 의 물체를 분리 해냄으로써 외제 시스템들 보다 우수하게 평가 되었다. 차폐 경사코일의 Eddy current영향은2%이내로 촬영 시 영향은 거의 무시할 수 있었다. 또한, 개발된 영상 기법들, 즉 Multislice/Multi Echo, Oblique angle imaging, 64 Echo train을 갖는 고속 촬영 기술들이 자기 공명 장치에 장착되어 임상 적용에 문제가 없도록 하였다. 또한 20mT/m/Amp의 강력한 능동 차폐 경사 자계 코일(Active Shield Gradient Coil)을 기본 사양으로 하고, 수신단을 최대 6개로 확장토록 하여 2차년도의 초고속 촬영 기법(EPI) 및 Phased Array 코일 촬영이 가능토록 하였다. 1차 년도 개발 과제 수행 결과와 향후 개발 과제를 바탕으로 최종 목표인 국제 경쟁력이 있는 자기 공명 진단 장치 즉 기능과 영상의 질은 선진국 제품과 동일하거나 우수하되, 저가격을 구현한 상용화 제품이 완성되어, 첨단 의료기기로서 산업 구조 고도화에 기여하고 수입대체 뿐만 아니 라 수출을 통한 국익 창출과 국가의 기술을 통한 위상 제고에 기여되길 기대한다.

  • PDF

Improved Diagnostic Accuracy in Characterization of Adnexal Masses by Detection of Choline Peak Using 1H MR Spectroscopy in Comparison to Internal Reference at 3 Tesla

  • Malek, Mahrooz;Pourashraf, Maryam;Gilani, Mitra Modares;Gity, Masoumeh
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.12
    • /
    • pp.5085-5088
    • /
    • 2015
  • Background: The aim of this study was to assess the role of the presence of a choline peak in 3 Tesla 1H magnetic resonance spectroscopy (MRS) for differentiating benign from malignant adnexal masses. Materials and Methods: A total of 46 adnexal masses (23 malignant and 23 benign) underwent 1H MRS study prior to surgery to assess the presence of choline peak. Results: A choline peak was detected in 16 malignant masses (69.5%) and was absent in the other 7 (30.5%). A choline peak was only detected in 6 (26%) of the benign adnexal masses. The presence of an MRS choline peak had a sensitivity of 69.5%, a specificity of 74%, a positive predictive value (PPV) of 72.7%, and a negative predictive value (NPV) of 71% for diagnosing malignant adnexal masses. A significant difference between the frequency of mean choline peaks in benign and malignant adnexal masses was observed (P value < 0.01). Conclusions: A 1H MRS choline peak is seen in malignant adnexal masses more frequently than the benign masses, and may be helpful for diagnosing malignant adnexal masses.

Application and Type of Magnetic Separator (자력선별장비의 유형과 활용)

  • Lee, Sang-hun;Yang, Injae;Choi, Seungjin;Park, Jayhyun
    • Resources Recycling
    • /
    • v.27 no.6
    • /
    • pp.11-22
    • /
    • 2018
  • Magnetic separators has been used in the mining and the recycling fields in general, and is still applied in wide variety of fields. It is classified into the equipments for separating coarse ferrous scrap from non-ferrous materials and the equipments for concentrating fine ferromagnetic particles below 3mm. Magnetic separation equipments for concentrating fine materials also falls into two categories of low intensity and high intensity magnetic separators. The former is used for ferromagnetic materials but also paramagnetic materials of high magnetic susceptibility, and the latter for paramagnetic materials of lower magnetic susceptibility. Both low and high intensity magnetic separators could be utilized either dry and wet. Recently, the High gradient magnetic separators(HGMS) used in the range of less than 0.7 tesla has been gradually replaced by the magnetic separator made of rare earth permanent magnets commercialized in the 1980s. In addition, the expansion of nanotechnology in terms of synthetic magnetic materials in the environmental and biological fields is expected to contribute positively to the development of magnetic separation technology.

Research Trends in Domestic and International Al chips (국내외 인공지능 반도체에 대한 연구 동향 )

  • Hyun Ji Kim;Se Young Yoon;Hwa Jeong Seo
    • Smart Media Journal
    • /
    • v.13 no.3
    • /
    • pp.36-44
    • /
    • 2024
  • Recently, large-scale artificial intelligence (AI) such as ChatGPT have been developed, and as AI is used across various industrial fields, attention is focused on AI chips (semiconductors). AI chips refer to chips designed for calculations for AI algorithms, and many companies at domestic and abroad, such as NVIDIA, Tesla, and ETRI, are developing AI chips. In this paper, we survey research trends on nine types of AI chips. Currently, many attempts have been made to improve the computational performance of most AI chips, and semiconductors for specific purposes are also being designed. In order to compare various AI semiconductors, each chip is analyzed in terms of operation unit, speed, power, and energy efficiency. We introduce currently existing optimization methodologies for AI computation. Based on this, future research directions for AI semiconductors are presented in this paper.

Magnetic Properties of SrRuO3 Thin Films Having Different Crystal Symmetries

  • Kim, Jin-I;Jung, C.U.
    • Journal of Magnetics
    • /
    • v.13 no.2
    • /
    • pp.57-60
    • /
    • 2008
  • This study examined the effect of various types of epitaxial strain on the magnetic properties of $SrRuO_3$ thin films. Epitaxial $SrTiO_3$ (001), $SrTiO_3$ (110), and $SrTiO_3$ (111) substrates were used to apply different crystal symmetries to the grown films. The films were grown using pulsed laser deposition. The X-ray diffraction patterns of the films grown under optimum conditions showed very clear peaks for the $SrRuO_3$ film and $SrTiO_3$ substrates. The saturated magnetic moment at 5 K after 7 Tesla field cooling was $1.2-1.4\;{\mu}_B$/Ru. The magnetic easy axis for all three types of films was along the surface normal. The magnetic transition temperature for the $SrRuO_3$ film with lower symmetry was slightly larger than the $SrRuO_3$ film with higher symmetry.

f-MRI with 2D & 3D Visual Stimuli

  • 김치영;김남주;문길영;임종우;정성택;최보영;신경섭;안창범
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.141-141
    • /
    • 2001
  • 목적: 최근 들어 컴퓨터 그래픽의 발전과 함께 가상 현실 등에 연구 및 응용이 급증하고 있다. 본 연구의 목적은 fMRI를 이용하여 이차원 및 삼차원 시각자극에 대한 뇌의 기능을 살펴보는 것이다. 같은 영상에 대한 2D와 3D영상을 보여 주면서, fMRI 영상 데이터를 얻었다. 사람에게 미치는 자극 중에 하나인 시각 자극에서 2D와 3D에 대해 반응하는 차이를 규명하고자 하였다. 대상 및 방법: Gradient echo를 기반으로 한 EPI 영상기법을 이용하여, 가톨릭 의대의 3.0 Tesla whole body MRI system에서 실험하였다. 해부학적 영상을 얻기 위해서는 spin echo를 이용하였다. 4명의 volunteer에 대해 같은 영상에 대한 2D와 3D영상을 보여주면서 실험을 수행하였다. 시각자극의 paradigm은 5단계 (rest, active, rest, active, rest)로 하였고, 3번의 rest와 2번의 active구간을 사이에 두었다. 각각의 구간은 10번의 iteration으로 이루어져 있고, 첫 번째 구간은 15번으로 하여 처음 5개의 결과를 버리고, 데이터를 얻었다. 결과는 spm99를 이용하여 분석하였다.

  • PDF

f-MRI with 2D & 3D Visual Stimuli

  • 김치영;김남주;문길영;임종우;정성택;최보영;신경섭;안창범
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.110-110
    • /
    • 2001
  • 목적: 최근 들어 컴퓨터 그래픽의 발전과 함께 가상 현실 등에 연구 및 응용이 급증하고 있다. 본 연구의 목적은 fMRI를 이용하여 이차원 및 삼차원 시각자극에 대한 뇌의 기능을 살펴보는 것이다. 같은 영상에 대한 2D와 3D영상을 보여 주면서, fMRI 영상 데이터를 얻었다. 사람에게 미치는 자극 중에 하나인 시각 자극에서 2D와 3D에 대해 반응하는 차이를 규명하고자 하였다. 대상 및 방법: Gradient echo를 기반으로 한 EPI 영상기법을 이용하여, 가톨릭 의대의 3.0 Tesla whole body MRI system에서 실험하였다. 해부학적 영상을 얻기 위해서는 spin echo를 이용하였다. 4명의 volunteer에 대해 같은 영상에 대한 2D와 3D영상을 보여주면서 실험을 수행하였다. 시각자극의 paradigm은 5단계 (rest, active, rest, active, rest)로 하였고, 3번의 rest와 2번의 active구간을 사이에 두었다. 각각의 구간은 10번의 iteration으로 이루어져 있고, 첫 번째 구간은 15번으로 하여 처음 5개의 결과를 버리고, 데이터를 얻었다. 결과는 spm99를 이용하여 분석하였다.

  • PDF

Analysis and reduction of thermal magnetic noise in liquid-He dewar for sensitive low-field nuclear magnetic resonance measurements

  • Hwang, S.M.;Yu, K.K.;Lee, Y.H.;Kang, C.S.;Kim, K.;Lee, S.J.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.2
    • /
    • pp.20-23
    • /
    • 2013
  • For sensitive measurements of micro-Tesla nuclear magnetic resonance (${\mu}T$-NMR) signal, a low-noise superconducting quantum interference device (SQUID) system is needed. We have fabricated a liquid He dewar for an SQUID having a large diameter for the pickup coil. The initial test of the SQUID system showed much higher low-frequency magnetic noise caused by the thermal magnetic noise of the aluminum plates used for the vapor-cooled thermal shield material. The frequency dependence of the noise spectrum showed that the noise increases with the decrease of frequency. This behavior could be explained from a two-layer model; one generating the thermal noise and the other one shielding the thermal noise by eddy-current shielding. And the eddy-current shielding effect is strongly dependent on the frequency through the skin-depth. To minimize the loop size for the fluctuating thermal noise current, we changed the thermal shield material into insulated thin Cu mesh. The magnetic noise of the SQUID system became flat down to 0.1 Hz with a white noise of 0.3 $fT/{\surd}Hz$, including the other noise contributions such as SQUID electronics and magnetically shielded room, etc, which is acceptable for low-noise ${\mu}T$-NMR experiments.