• 제목/요약/키워드: 3 Point bending test

검색결과 371건 처리시간 0.024초

FRC를 적용한 FRP-콘크리트 합성보의 거동특성 (Behavior Characteristics of FRP-Concrete Composite Beam using FRC)

  • 조정래;조근희;김병석;진원종;김성태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.742-745
    • /
    • 2004
  • The FRP-concrete composite deck system has advantages of corrosion free and easy construction. The system is, however, comprised of two brittle materials, so that it suffers from inherent disadvantage of lack of ductility. In this study, some conceptual design is presented for preventing the brittle failure of FRP-concrete composite deck at ultimate load level. 4-point bending tests are performed for FRP-concrete composite beams using FRC(Fiber Reinforced Concrete). The specimens use the box-shape FRP member in the lower portion. Four types of concrete with different compressive strengths and ductilities including normal mortar and 3 FRCs are placed in the upper portion. Typical failure mode in the test is identified; Concrete compressive failure occurs first at the maximum moment region, and the interfacial debonding between FRP and concrete member proceeds. Finally, the tensile rupture of FRP member occurs. The specimen using FRC with the high compressive ductility of concrete fails with less brittle manner than other specimens. The reason is that the ductility from the concrete in compression prevents the sudden loss of load-carrying capacity after compressive concrete failure.

  • PDF

Space holder 공정으로 제조된 치과 임플란트용 타이타늄 다공체의 파손 분석 (Fracture Analysis of Porous Titanium for Dental Implant Fabricated by Space Holder Process)

  • 이승미;장진만;이원식;변재원
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제16권2호
    • /
    • pp.104-109
    • /
    • 2016
  • Purpose: The purpose of this study is to analyze fracture behavior and failure mechanism of porous titanium for dental implant fabricated by space holder process. Method: Three porous titanium specimens with a specific volume fraction of open pore were test by 3 point bending and compression stress condition, respectively. Fracture appearance was observed by scanning electron microscope and discussed in relation with oxygen content. Results: For compression-tested specimens, two specimen showed brittle failure, while the other one showed normal failure after deformation. High oxygen content was detected in the brittle-fractured specimen. Several micro-cracks initiated at the struts propagated down to the bottom of the specimen resulting in normal failure. Conclusion: Oxygen contamination during the fabrication process can leads brittle premature failure, and hence quality problem of the porous titanium for dental implant.

Recommendation for the modelling of 3D non-linear analysis of RC beam tests

  • Sucharda, Oldrich;Konecny, Petr
    • Computers and Concrete
    • /
    • 제21권1호
    • /
    • pp.11-20
    • /
    • 2018
  • The possibilities of non-linear analysis of reinforced-concrete structures are under development. In particular, current research areas include structural analysis with the application of advanced computational and material models. The submitted article aims to evaluate the possibilities of the determination of material properties, involving the tensile strength of concrete, fracture energy and the modulus of elasticity. To evaluate the recommendations for concrete, volume computational models are employed on a comprehensive series of tests. The article particularly deals with the issue of the specific properties of fracture-plastic material models. This information is often unavailable. The determination of material properties is based on the recommendations of Model Code 1990, Model Code 2010 and specialized literature. For numerical modelling, the experiments with the so called "classic" concrete beams executed by Bresler and Scordelis were selected. It is also based on the series of experiments executed by Vecchio. The experiments involve a large number of reinforcement, cross-section and span variants, which subsequently enabled a wider verification and discussion of the usability of the non-linear analysis and constitutive concrete model selected.

Repaired glass ionomer cement의 결합강도에 관한 연구 (A STUDY ON THE BOND STRENGTH OF REPAIRED GLASS IONOMER CEMENTS)

  • 서수정;김신
    • 대한소아치과학회지
    • /
    • 제23권2호
    • /
    • pp.347-355
    • /
    • 1996
  • The purpose of this study was to compare the bond strengths of different kinds of glass ionomer cements (GIC), which is recently increasing the clinical application in the field of pediatric dentistry and measure the repaired bond strengths in order to examine the clinical applicabilty of partial repaired cases. By using one kind of the light cured type GIC and three kinds of the chemical cured type GIC, the bond strengths of the followings were compared : unrepaired group as control, repaired conditioning group, which was treated the repaired surface using 25% polyacrylic acid and repaired non-conditioning group without surface treatment. Three point bending test was performed under Universal Testing Machine in order to measure the compressive bond strengths. The results were as follows : 1. Light cured GIC had higher bond strength than chemical cured type GIC in both of repaired and unrepaired groups. 2. In repaired cases, all of the materials decreased the bond strength when compared to the control group. In the light cured type, the bond strength of repaired conditioning group decreased 31.6%, repaired non-conditioning group decreased 40.8%. In chemical cured types, the bond strength of repaired conditining group decreased 11.8%, repaired non-conditioning group decreased 20.9%. 3. All the materials, in the case of the chemical treatment on the repaired surface using 25% polyacrylic acid had higher bond strength than untreated but, lower than control group.

  • PDF

강섬유 보강 콘크리트의 조기 재령에서의 휨 인성 발현에 관한 연구 (Investigation of Flexural Toughness Development of Steel Fiber Reinforced Concrete at Early Ages)

  • 이창준;신성우
    • 한국안전학회지
    • /
    • 제24권6호
    • /
    • pp.103-110
    • /
    • 2009
  • Since the mechanical properties of cement-based materials are time-dependent due to the prolonged cement hydration process, those of fiber reinforced concrete(FRC) may also be time-dependent. Toughness is one of important properties of FRC. Therefore, it should be investigated toughness development of FRCs with curing ages to fully understand the time-dependent characteristics of FRCs. To this end, the effect of curing ages on flexural toughness development of steel fiber reinforced concrete is studied. Three point bending test with notched beam specimen was adapted for this study. Hooked-end steel fiber(DRAMIX 40/30) was used as a fiber ingredient to investigate w/c ratio and fiber volume fraction effect on toughness development during curing. Three different water-cement ratios(0.44, 0.5 and 0.6) and fiber volume fractions(0%, 0.5% and 1%) were used as influence factors. Each mixture specimens were tested at five different ages, 0.5, 1, 3, 7 and 28 days. The study shows that flexure toughness development with age is quite different than other concrete material properties such as compressive strength. The study also shows that the toughness development trend correlates more closely to water/cement ratio than to fiber volume fraction.

STRUCTURAL TEST AND ANALYSIS OF RC SLAB AFTER FIRE LOADING

  • Chung, Chul-Hun;Im, Cho Rong;Park, Jaegyun
    • Nuclear Engineering and Technology
    • /
    • 제45권2호
    • /
    • pp.223-236
    • /
    • 2013
  • In the present study the behavior of fire and the residual strength of fire-ignited RC slabs are investigated by experimental tests and numerical simulations. The fire tests of RC slabs were carried out in a furnace using the ISO 834 standard fire. The load capacity of the cooled RC slabs that were not loaded during the fire tests was evaluated by additional 3 point bending tests. The influence of the proportion of PP (polypropylene) fibers in the RC slabs on the structural behavior of the RC slabs after the fire loading was investigated. The results of the fire tests showed that the maximum temperature of concrete with PP fiber was lower than that of concrete without PP fiber. As the concrete was heated, the ultimate compressive strength decreased and the ultimate strain increased. The load-deflection relations of RC slabs after fire loading were compared by using existing stress-strain-temperature models. The comparison between the numerical analysis and the experimental tests showed that some numerical analyses were reliable and therefore, can be applied to evaluate the ultimate load of RC slabs after fire loading. The ultimate load capacity after cooling down the RC slabs without PP fiber showed a considerable reduction from that of the RC slabs with PP fiber.

자동차용 $35kgf/\textrm{mm}^2$급 강판의 레이저 강화 (Laser Strengthening of $35kgf/\textrm{mm}^2$ Grade Steel Sheet far Automobile)

  • 서정;이제훈;김정오;오상진;조원석;이두환;신철수;이문용;이규현
    • Journal of Welding and Joining
    • /
    • 제20권1호
    • /
    • pp.34-40
    • /
    • 2002
  • The laser strengthening of $35kgf/\textrm{mm}^2$ grade steel sheet is investigated by using $CO_2$ laser beam irradiation. The increase of tensile strength is dominated by the number of fully penetrated melting lines. Also, the optimal laser irradiation pattern is obtained by 3-point bending test. Local laser strengthening clay be effective for the weight reduction of automobile components where the tailored welded blank can not be applied.

웨이퍼 그라인딩 공정으로 생성된 스크래치 마크를 갖는 실리콘 칩들에서의 벽개 파괴현상 (Cleavage Fracture Phenomenon in Silicon Chips with Wafer Grinding-Induced Scratch Marks)

  • 이동기;이태규;이성민
    • 대한금속재료학회지
    • /
    • 제49권9호
    • /
    • pp.726-731
    • /
    • 2011
  • The present work shows how the flexural displacement-induced fracture strength of silicon devices, whose back surfaces have wafer grinding-induced scratch marks, depends on the crystallographic orientation. Experimental results indicate that silicon devices with scratch marks parallel to their lateral direction (i.e. reference axis in this work) are very susceptible to flexural fracture, as compared to devices with marks which deviated from the direction. The 3-point bending test shows that the fracture strength of silicon devices having marks which are oriented away from the reference axis is 2.6 times higher than that of devices with marks parallel to the axis. It was particularly interesting to see that silicon devices with identical preferred marks even reveal different fracture strengths, depending on whether the marks are involved in specific crystal planes such as {111} or {011}, called cleavage planes. This work demonstrates that silicon devices with the reference axis-aligned scratch marks not existing on such cleavage planes can have higher fracture strength approximately 20% higher than those existing on the planes.

Dynamics of moored arctic spar interacting with drifting level ice using discrete element method

  • Jang, HaKun;Kim, MooHyun
    • Ocean Systems Engineering
    • /
    • 제11권4호
    • /
    • pp.313-330
    • /
    • 2021
  • In this study, the dynamic interaction between an Arctic Spar and drifting level ice is examined in time domain using the newly developed ice-hull-mooring coupled dynamics program. The in-house program, CHARM3D, which is the hull-riser-mooring coupled dynamic simulator is extended by coupling with the open-source discrete element method (DEM) simulator, LIGGGHTS. In the LIGGGHTS module, the parallel-bonding method is implemented to model the level ice using an assembly of multiple bonded spherical particles. As a case study, a spread-moored Artic Spar platform, whose hull surface near waterline is the inverted conical shape, is chosen. To determine the breaking-related DEM parameter (the critical bonding strength), the four-point numerical bending test is used. A series of numerical simulations is systematically performed under the various ice conditions including ice drift velocity, flexural strength, and thickness. Then, the effects of these parameters on the ice force, platform motions, and mooring tensions are discussed. The simulations reveal various features of dynamic interactions between the drifting ice and moored platform for various ice conditions including the novel synchronous resonance at low ice speed. The newly developed simulator is promising and can repeatedly be used for the future design and analysis including ice-floater-mooring coupled dynamics.

Experimental and numerical study of the behavior of fiber reinforced concrete beams with nano-graphene oxide and strengthening CFRP sheets

  • Mohammad Reza Halvaeyfar;Ehsanollah Zeighami;S. Mohammad Mirhosseini;Ali Hassani Joshaghani
    • Structural Engineering and Mechanics
    • /
    • 제87권4호
    • /
    • pp.375-389
    • /
    • 2023
  • In many fiber concrete beams with Carbon Fiber Reinforced Polymer (CFRP), debonding occurs between the carbon sheets and the concrete due to the low strength of the bonding resin. A total of 42 fiber concrete beams with a cross-section of 10×10 cm with a span length of 50 cm are fabricated and retrofitted with CFRP and subjected to a 4-point bending test. Graphene Oxide (GO) at 1, 2, and 3 wt% of the resin is used to improve the mechanical properties of the bonding resins, and the effect of length, width, and the number of layers of CFRP and resin material are investigated. The crack pattern, failure mode, and stress-strain curve are analyzed and compared in each case. The results showed that adding GO to polyamine resin could improve the bonding between the resin and the fiber concrete beam. Furthermore, the optimum amount of nanomaterials is equal to 2% by the weight of the resin. Using 2% nanomaterials showed that by increasing the length, width, and number of layers, the bearing and stiffness of fiber concrete beams increased significantly.