• Title/Summary/Keyword: 3 Dimensional Enclosure

Search Result 55, Processing Time 0.021 seconds

NUMERICAL STUDY FOR PRANDTL NUMBER DEPENDENCY ON NATURAL CONVECTION IN AN ENCLOSURE WITH SQUARE ADIABATIC BODY (사각 단열체가 존재하는 밀폐계 내부에서 Pr수 변화에 따른 자연대류 현상에 대한 수치적 연구)

  • Lee, Jae-Ryong
    • Journal of computational fluids engineering
    • /
    • v.16 no.3
    • /
    • pp.29-36
    • /
    • 2011
  • The natural convection in a horizontal enclosure heated from the bottom wall, cooled at the top wall, and having a square adiabatic body at its centered area was studied. Three different Prandtl numbers (0.01, 0.7 and 7) were considered for an effect of the Prandtl number on natural convection. A two-dimensional solution for unsteady natural convection was obtained, using Chebyshev spectral methodology for different Rayleigh numbers varying over the range of $10^4$ to $10^6$. It had been experimentally and numerically reported [1,2] that the heat transfer mode becomes oscillatory when Pr is out of a specific Pr band beyond the critical Ra. In this study, we reproduced this phenomenon numerically. The variation of time- and surface-averaged Nusselt numbers on the hot and cold walls for different Rayleigh numbers and Prandtl numbers was presented to show the overall heat transfer characteristics in the system. And also, the isotherms and streamline distributions were presented in detail to compare the physics related to their thermal behavior.

Natural Convective Heat Transfer and Flow Characteristics in Inclined Rectangular Enclosures with Localized Heating from Below (밑면에서 부분가열을 받는 경사4각형 밀폐공간내의 자연대류 열전달 및 유동특성)

  • Kim, Sang-Ho;Chung, In-Kee;Kim, Jung-Yeup
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.13 no.3
    • /
    • pp.148-156
    • /
    • 1984
  • The effect of inclination on the steady, two-dimensional, laminar natural convection in rectangular enclosures with localized heating from below has been investigated numerically. The enclosure was uniformly heated with a partial heat source at the center of the bottom wall and cooled from the upper wall while the other walls were insulated. The governing equations were solved numerically by using the ADI finite difference method with the SOR method. The computations were carrid out with air, Pr =0.733, in the Grashof number range, $1\times10^4\~3\times10^4$, for the inclination of the enclosures was varied from $0^{\circ}\;to\;90^{\circ}$. The effects of Grashof number and aspect ratio on the inclination for the transition of the flow pattern in enclosures were determined. From the results, it was found that the transition angles of the flow in the enclosures were greater in localized heating than in uniform heating from below, and that the inclination was to strongly effect on the heat transfer and the flow pattern within the enclosure.

  • PDF

A Numerical Study on the Two-Dimensional Turbulent Natural Convection Using a Low-Reynolds Number k-$\varepsilon$ Model (저레이놀즈수 k-$\varepsilon$ 모델을 사용한 2차원 자연대류 난류현상에 대한 수치적 연구)

  • 강덕홍;김우승;이관수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.3
    • /
    • pp.741-750
    • /
    • 1995
  • The turbulent buoyancy-driven flow in 2-dimensional enclosed cavities heated from the vertical side is numerically calculated for both cases of a Rayleigh number of 5*10$^{10}$ for air and 2.5*10$^{10}$ for water. Three different turbulence models are considered : standard k-.epsilon. model of Ozoe and low-Reynolds-number model of Lam and Bremhorst, and another low-Reynolds-number model of Davidson. The results indicate that the use of low-Reynolds number models is recommended for the indoor airflow computation, and the results from Davidson model are reasonably close to the reported experimental data. A sensitivity study shows that the amounts of wall-heat transfer and the velocity profiles with the Lam and Bremhorst model largely depend on the choice of the wall function for .epsilon..

A Fundamental Study on Development of a Wall Structure type Thermal Diode for Energy Saving (에너지 절약을 위한 벽체형 열다이오드 개발에 관한 기초)

  • Pak, E.T.;Chang, Y.G.;Chea, S.S.
    • Solar Energy
    • /
    • v.17 no.3
    • /
    • pp.67-73
    • /
    • 1997
  • In order to development of a new wall structure type thermal diode for energy saving, the numerical studies have been performed for natural convection across an rectangular enclosure with the various lengthes of the heat source and sink plate. The governing equations for the two-dimensional, laminar, natural convection process in an enclosure are discretized by the control volume approach which insures the conservative characteristics to be satisfied in the calculation domain, and solved by a elliptic SIMPLE algorithm. The momentum and energy equations are coupled through the buoyancy term.

  • PDF

Effect of Metallic Particles on E-field Enhancement in Extra High Voltage Gas-insulated Transmission Lines

  • Rao, M. Mohana;Satyanarayana, S.;Kumar, S. Vinay;Jain, H.S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.4
    • /
    • pp.631-636
    • /
    • 2010
  • Gas-insulated transmission lines (GITL) are valued as technological solutions in hydro-power stations due to their enormous power handling capabilities. The performance of GITL is a function of the size of metallic particles inside the gas-insulated chamber. Electrostatic field (E-field) enhancement is a common phenomenon in gas-insulated lines due to these metallic particles. In this study, the E-field enhancement factor is calculated by considering metallic particles at various locations in the gas-insulated line/bus section, such as high-tension (HT) conductor, high-voltage shields, support insulator, and inner surface of grounded enclosure. For this purpose, a two-dimensional model based on finite element (FE) method is developed. The length of the metallic particle is in the range of 1 to 10 mm while the diameter is between 1 to 3 mm. E-field enhancement is also computed for various particle configurations of the gas-insulated system, with focus on dielectric coating made of epoxy on HT conductor and inner surface of grounded enclosure.

Numerical Analysis of Natural Convection-Radiation Heat Transfer in an Enclosure Containing Absorbing, emitting and Linear Anisotropic Scattering Medium (흡수,방사 및 선형비등방 산란 매질을 포함하는 밀폐공간내의 자연대류- 복사열전달에 대한 수치해석)

  • 차상명;김종열;박희용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.5
    • /
    • pp.952-964
    • /
    • 1992
  • The interaction of natural convection and radiation heat transfer in a two dimensional square enclosure containing absorbing, emitting and linear anisotropically scattering gray medium is numerically analyzed. P-1 and P-3 approximation is introduced to calculate radiation heat transfer. The effects of scattering albedo, wall emissivity, scattering anisotropy, and optical thickness on the characteristics of the flow and temperature field and heat transfer are investigated. Temperature and velocity profiles depend a great deal on the scattering albedo, and the importance of this effect increases with decrease in albelo. Planck number is another important parameter in radiation heat transfer. The increase in scattering albedo increases convection heat transfer and decreases radiation heat transfer at hot wall. However, the increase in scattering albedo decreases both convection and radiation heat transfer at cold wall. The increase in optical thickness decreases radiation heat transfer. The scattering anisotropy has important effects on the radiation heat transfer only. The highly forward scattering leads to an increase of radiation heat transfer whereas the highly backward scattering leads to an decrease of radiation heat transfer. The effect of scattering anisotropy decreases when reducing the wall emissivity.

Three-dimensional natural convection cooling of the electronic device with the effects of convective heat dissipation and vents (전자장비에서 벽면의 대류열방출 및 통기구의 효과를 고려한 3차원 자연대류 냉각)

  • ;;;Baek, Chang-In;Lim, Kwang-Ok
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.11
    • /
    • pp.3072-3083
    • /
    • 1995
  • The numerical simulation on the three-dimensional natural convection heat transfer in the enclosure with heat generating chip is performed, and the effects of convective heat loss and vents are also examined. The effects of the Rayleigh number and outer Nusselt number (Nu$_{0}$) on the maximum chip temperature and the fractions of heat loss from the hot surfaces are investigated. The results show that conduction through the substrate is dominant in heat dissipation. With the increase of Rayleigh number, heat dissipation through the chip surfaces increases and heat loss through the substrate decreases. Maximum dimensionless temperature with vents is found to decrease about 40% compared to the one without vents at Nu$_{0}$=0.l. It is also shown that effects of size and location of the vents are negligible.ble.

Resonance Frequency of the Natural Convection in the Closure Cavity for the Variable Aspect Ratio (종횡비가 변하는 공동 내 자연대류의 공진주파수)

  • Chun, Kun-Ho;Joo, Kwang-Sup;Choi, Young-Don
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.609-614
    • /
    • 2000
  • This numerical study investigate resonance frequency of natural convection for steady state, periodic flow and chaotic flow in two-dimensional direct numerical simulations, differentially heated, vertical cavities having aspect ratios near unity. The enclosure cavity has isothermal and time dependent temperature side walls and adiabatic top/bottom walls. The aspect ratio is 1/3, 1/2, 1, 2, and 3 for the varying Rayleigh number. Resonance frequency for AR=1 has decrease as the aspect ratio and the Rayleigh number are increasing.

  • PDF

Study on Nongray Gas Radiation within a Cylindrical Enclosure by Using the Narrow Band Model (좁은밴드모델을 이용한 실린더 내의 비회색 가스 복사열전달 연구)

  • Park, Won-Hee;Jung, Hyun-Sung;Kim, Tae-Kuk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.6
    • /
    • pp.859-867
    • /
    • 2002
  • Radiative transfer in energy systems such as furnaces, combustors, boilers and high temperature machineries is a significant mode of heat transfer. Although there are many solution schemes suggested for analysis of radiative transfer in multi-dimensional systems, the applicabilities and accuracies of these schemes have not fully tested for nongray gases. Especially reference data for enclosures of non-orthogonal shapes are not yet enough. In this paper we present some precise radiative transfer solutions for a black walled 3-dimensional cylindrical system filled with nongray gases. The SNB(statistical narrow band) model and the ray-tracing method with the T$_{N}$ quadrature set are used for finding nongray solutions. Although the solution method used in this study is not suitable for engineering purposes, the resulting solutions are proved to be quite accurate and can be regarded as the exact solutions and the results presented in this paper can be used in developing various solution schemes fur radiative transfer by real gas mixtures.s.

Numerical Study of Thermal Convection in Horizontal Enclosure with Heat Generating Conducting Body (발열 전도체를 가지는 밀폐계 내부의 자연대류 현상에 대한 수치적 연구)

  • Lee, Jae-Ryong;Ha, Man-Yeong
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1080-1085
    • /
    • 2004
  • The physical model considered here is a horizontal layer of fluid heated below and cold above with heat-generating conducting body placed at the center of the layer. The dimensionless thermal conductivities of body considered in the present study are 0.01, 1 and 150. The dimensionless temperature difference ratios considered are 0.25, 2.5 and 25. Two-dimensional solution for unsteady natural convection is obtained using an accurate and efficient Chebyshev spectral methodology for variety of Rayleigh number from $10^{3}$ to $10^{6}$. Multi-domain technique is used to handle square-shaped heat-generating conducting body. The results for the case of conducting body with heat generation are also compared to those without heat generation.

  • PDF