• Title/Summary/Keyword: 3 Coordinate Measuring Machine

Search Result 91, Processing Time 0.026 seconds

Development of a measurement system for the surface of micro-parts (초소형 마이크로 부품 표면 측정 시스템 개발)

  • Hong Seong-Wook;Ko Myung-Jun;Shin Young-Hyun;Lee Deug-Woo
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.413-418
    • /
    • 2005
  • This paper proposes a measurement method for the surface of micro-parts by using AFM(Atomic Force Microscope). To this end, two techniques are presented to extend the capacity of AFM. First, the measurement range is extended by using an image matching method based on correlation coefficients. To account for the inaccuracy of the coarse stage implemented in AFM's, the image matching technique is applied to two neighboring images intentionally overlapped with each other. Second, a method to measure the shape of relatively large specimen is presented by using the inherent trigger mechanism due to the atomic force. The proposed method is proved effective through a series of experiments.

  • PDF

Development of a Measurement System for the Surface Shape of Micro-parts by Using Atomic Force Microscope (원자간력 현미경을 이용한 초소형 마이크로 부품 표면 형상 측정 시스템 개발)

  • Hong Seong-Wook;Ko Myung-Jun;Shin Young-Hyun;Lee Deug-Woo
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.6
    • /
    • pp.22-30
    • /
    • 2005
  • This paper proposes a measurement method for the surface shape of micro-parts by using an atomic force microscope(AFM). To this end, two techniques are presented: First, the measurement range is expanded by using an image matching method based on correlation coefficients. To account for the inaccuracy of the coarse stage implemented in AFM, the image matching technique is applied to two neighboring images intentionally overlapped with each other. Second, a method to measure the shape of relatively large specimen is proposed that utilizes the inherent trigger mechanism due to the atomic force. The proposed methods are proved effective through a series of experiments.

A Method for Generation of Grinding Map based on Automatic Mold Measurement (금형 자동측정에 의한 사상맵 생성)

  • Jeoung, Nam-Yeoung;Cho, Jin-Hyung;Oh, Hyun-Seung;Lee, Sae-Jae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.4
    • /
    • pp.248-255
    • /
    • 2018
  • Ensuring the quality of molds is one of the major issues in mass production. In general, securing the quality of the molds is achieved by repeating grinding and die spotting after machining the molds based on engineer's decision. However, this heuristic method is affected by the engineer's skill and working environment. Therefore, a lot of time and resources are needed in order to ensure quality. In this study, ensuring the quality of molds using grinding map which is generated using automatic measurement is proposed. An automatic measuring system based on CMM (Coordinate Measuring Machine) is developed for measuring the molds. This system generates the measurement path automatically using the 3D CAD model of products. CAD (ComputerAided-Design), CAM (Computer-Aided-Manufacturing), and CAQ (Computer-Aided-Quality) technology is integrated using DMIS (Dimensional Measuring Interface Standard) format in the automatic measuring system. After measuring the molds, a grinding map is generated using the gap between the CAD model and measured values of mold. The grinding map displays the machining tendency and the required amount of grinding with values on a 3D map. Therefore, the quality of molds can be ensured with exactness and quickness based on the grinding map. This study shows that integrating the planning, measuring, and analyzing based on computer technology can solve the problem of quality assurance of mold using the proposed method, therefore the productivity can be increased.

A Study of an OMM System for Machined Spherical form Using the Volumetric Error Calibration of Machining Center (머시닝센터의 체적오차 보상을 통한 구면 가공형상 측정 OMM시스템 연구)

  • Kim, Sung-Chung;Kim, Ok-Hyun;Lee, Eung-Suk;Oh, Chang-Jin;Lee, Chan-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.7
    • /
    • pp.98-105
    • /
    • 2001
  • The machining accuracy is affected by geometric, volumetric errors of the machine tools. To improve the product quality, we need to enhance the machining accuracy of the machine tools. To this point of view, measurement and inspection of finished part as error analysis of machine tools ahas been studied for last several decades. This paper suggests the enhancement method of machining accuracy for precision machining of high quality metal reflection mirror or optics lens, etc. In this paper, we study 1) the compensation of linear pitch error with NC controller compensation function using laser interferometer measurement, 2) the method for enhancing the accuracy of NC milling machining by modeling and compensation of volumetric error, 3) the spherical surface manufacturing by modeling and compensation of volumetric error of the machine tool, 4) the system development of OMM without detaching work piece from a bed of machine tool after working, 5) the generation of the finished part profile by OMM. Furthermore, the output of OMM is compared with that of CMM, and verified the feasibility of the measurement system.

  • PDF

Three-dimensional Reconstruction of X-ray Imagery Using Photogrammetric Technique (사진측량기법을 이용한 엑스선영상의 3차원 모형화)

  • Kim, Eui Myoung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2D
    • /
    • pp.277-285
    • /
    • 2008
  • X-ray images are wildly used in medical applications, and these can be more efficiently find scoliosis which is appearing during the growth of human skeleton than others. This research is focused on the calibration of X-ray image and three-dimensional coordinate determination of objects. Three-dimensional coordinate of objects taken by X-ray are determined by two step procedure. Firstly, interior and exterior orientation parameters are determined by camera calibration using Primary Calibration Object (PCO) which has two sides with embedded radiopaque steel ball. Secondly, calibration cage coordinates which is composed of two acrylic sheets that are perpendicular to X-ray source are determined by the parameters. Three-dimensional coordinates of calibration cage determined by photogrammetric technique are compared with that of Coordinate Measuring Machine (CMM). Though the accuracy analysis, X direction which is parallel to X-ray source error values are relatively higher than those of Y and Z directions. But, the accuracies of Y and Z axis are approximately -3 mm to 3 mm. From the research results, it is considered that photogrammetric technique is applied to determine three-dimensional coordinates of patients or assist to make medical devices.

A study on based shape monitoring in HERW pipe production by using structured light beam (구조화된 직선빔을 이용한 구조파 전기 저항 용접파이프의 비드 형상 측정에 관한 연구)

  • 고국원;김종형;조형석;공원일
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.672-678
    • /
    • 1993
  • The bead shape in high frequency electric resistance (HER) pipe welding gives important information ons judging current welding state. In most manufacturing process, the heat input is controlled by skilled operators observing color and bead shape. We proposed the bead shape monitoring system in HERW pipe process by using structured light beam. We reconstructs 3-D shape of bead from the measured data, and compare this shape with real 3-D shape obtained by coordinate-measuring machine. This experiment results show that the proposed system can monitor the bead shape with good accuracy.

  • PDF

The performance improvement of the volumetric interferometer with multi-CCDs (다중 CCD를 이용한 부피 간섭계의 성능 개선)

  • 주지영;이혁교;김승우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.268-271
    • /
    • 2003
  • The Volumetric Interferometer using two spherical wavefronts emitted from the ends of two single mode fibers has been suggested to measure 3-dimensional absolute coordinates. In this paper, we try to improve the performance of the volumetric interferometer using multi-CCDs. We get coordinates matching matrixes between CCDs and can obtain more information in the space with multi-CCDs. Also we find out the best arrangement of multi-CCDs by computer simulations. In the simulation we can know that it will be better to increase the distance between CCDs to improve performance. For the performance test, we do a repeatability test, a comparison test with 2-D stage and the self-calibration using artifact.

  • PDF

A STUDY FOR THE MEASUREMENTS OF THE RESIDUAL STRESS AND THE DISTORTIONS IN THE CERAMO-METAL BRIDGE OF Pd-Ag ALLOY (팔라듐-은 합금 도재소부전장 가공의치의 잔류응력과 변형에 관한 연구)

  • Jeon, Young-Chan;Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.2
    • /
    • pp.53-78
    • /
    • 1989
  • This study was taken to observe the changes of the residual stress in the alloy and to measure 3 dimensional distortions of the long span ceramo-metal bridge. The materials used in this study were Pors-on 4 (Pd-Ag alloy), and Ceramco and Vita VMK 68 powders. The residual stress of the alloy was measured on the six specimens (dia. 8m/m) by the X-ray diffraction stress analyzer according to the kind of ceramic powder and different measuring stages. And, for the measurement of the distortions, fifteen specimens of the anterior 8-unit ceramo-metal brige were fabricated and subjected to the 3-D coordinate measuring machine. Variables included the 2 kinds of a ceramic powder and the presence or absence of a splint bar at the cast metal framework. The measuring stages in both were after casting, after degassing and after glazing. The following conclusions were obtained : 1. The residual stress of the alloy showed increasing tendency for the tension by the ceramic fusing, but there was not significance. 2. The tendency of the distortions in the cast metal frameworks were decrease of the width, the anterior displacement and sagging. 3. The amount of the distortions at the degassing stage were greater than that at the ceramic fusing stage. 4. The splint bar was effective to control the distortion only at ceramic fusing stage. 5. The sagging distortion in the Ceramco firing were even through all measuring stages, but in the Vita firing, pronounced at degassing stage.

  • PDF

Error Assessment of CMM by Self-calibration Method (자가 보정 방법을 이용한 삼차원 측정기의 계통 오차 추출)

  • 유승봉;김승우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.379-382
    • /
    • 2002
  • Among the CMM calibration techniques, the calibration with standard specimen is most accurate way to acquire the required precision. When there is no standard specimen, the calibration of CMM with itself is possible. This calibration method is called "self-calibration". In this paper, we developed self-calibration algorithm for CMM XY plane. It is possible to calculate the in-plane error and out-of-plane error of CMM with 3 different measurement of same artifact. Experimental result shows that the non-orthogonality error is dominant in in-plane error and the self-calibration result and laser interferometer measured result have almost same value.ame value.

  • PDF

Failure Behavior of Piercing Plug during Seamless Tube Manufacturing Process (심리스 튜브 제조공정 시 피어싱 플러그의 파손거동)

  • Lim, Young-Bin;Yoon, Jeong-Mo
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.30 no.5
    • /
    • pp.207-214
    • /
    • 2017
  • In this study, failure behavior of piercing plug for seamless tube manufacturing process was studied. Three different kinds of passed piercing plugs (10, 90, 215 times) were prepared. The shape deformation of the passed piercing plugs was observed by 3D coordinate measuring machine, and the oxidized layer on the surface of piercing plug was observed by optical microscopy. The length reduction of piercing plug presented at 215 times passed plug. It was found that the oxidized layer consisted of outer scale, inner scale and internal oxidation layers, and the inner scale layer had vertical cracks, and interfaces had horizontal cracks. We proposed the failure mechanism of piercing plug during seamless tube manufacturing process based on the formation of vertical and horizontal crack.