• Title/Summary/Keyword: 3차원 CAD

Search Result 466, Processing Time 0.029 seconds

Accuracy of Digital Impression Made from Different Elastomeric Impression Materials: Three-Dimensional Superimpositional Analysis (치과용 탄성 인상재를 기반으로 채득된 디지털 모형의 정확성 연구: 3차원 중첩 분석)

  • Kim, Ki-Baek;Jung, Jae-Kwan;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.14 no.2
    • /
    • pp.94-100
    • /
    • 2014
  • The purpose of this study was to evaluate the accuracy of digitized elastomeric impression materials of crown abutment, using non-contact white light scanner and virtual three-dimensional superimpositional analysis. The stone models and impressions were digitized white light scanner to create three-dimensional surface models. Stone models were used as CAD reference model (CRM). The resulting point clouds (ASC file) from digitization of impressions using converting software. Discrepancies between the points in the point clouds and CRM were measured by superimpositional software. Mean and standard deviation of values of discrepancies were analyzed by one-way ANOVA and multiple comparison (${\alpha}=0.05$). The mean discrepancy between the impressions for the extra-light body (XLB), light body (LB), and heavy body (HB) group were $5.10{\pm}1.45{\mu}m$, $6.30{\pm}1.87{\mu}m$, $9.80{\pm}1.52{\mu}m$, respectively. The different impression materials affected the digitization of impressions significantly (p<0.05). As a result, digitization of elastomeric impression materials on dental scanner was influenced by material sort.

Comparison of Helical TomoTherapy with Linear Accelerator Base Intensity-modulated Radiotherapy for Head & Neck Cases (두경부암 환자에 대한 선량체적 히스토그램에 따른 토모치료외 선형가속기기반 세기변조방사선치료의 정량적 비교)

  • Kim, Dong-Wook;Yoon, Myong-Geun;Park, Sung-Yong;Lee, Se-Byeong;Shin, Dong-Ho;Lee, Doo-Hyeon;Kwak, Jung-Won;Park, So-Ah;Lim, Young-Kyung;Kim, Jin-Sung;Shin, Jung-Wook;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.89-94
    • /
    • 2008
  • TomoTherapy has a merit to treat cancer with Intensity modulated radiation and combines precise 3-D imaging from computerized tomography (CT scanning) with highly targeted radiation beams and rotating beamlets. In this paper, we comparing the dose distribution between TomoTherapy and linear accelerator based intensity modulated radiotherapy (IMRT) for 10 Head & Neck patients using TomoTherapy which is newly installed and operated at National Cancer Center since Sept. 2006. Furthermore, we estimate how the homogeneity and Normal Tissue Complication Probability (NTCP) are changed by motion of target. Inverse planning was carried out using CadPlan planning system (CadPlan R.6.4.7, Varian Medical System Inc. 3100 Hansen Way, Palo Alto, CA 94304-1129, USA). For each patient, an inverse IMRT plan was also made using TomoTherapy Hi-Art System (Hi-Art2_2_4 2.2.4.15, TomoTherapy Incorporated, 1240 Deming Way, Madson, WI 53717-1954, USA) and using the same targets and optimization goals. All TomoTherapy plans compared favorably with the IMRT plans regarding sparing of the organs at risk and keeping an equivalent target dose homogeneity. Our results suggest that TomoTherapy is able to reduce the normal tissue complication probability (NTCP) further, keeping a similar target dose homogeneity.

  • PDF

Accuracy of 5-axis precision milling for guided surgical template (가이드 수술용 템플릿을 위한 5축 정밀가공공정의 정확성에 관한 연구)

  • Park, Ji-Man;Yi, Tae-Kyoung;Jung, Je-Kyo;Kim, Yong;Park, Eun-Jin;Han, Chong-Hyun;Koak, Jai-Young;Kim, Seong-Kyun;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.294-300
    • /
    • 2010
  • Purpose: The template-guided implant surgery offers several advantages over the traditional approach. The purpose of this study was to evaluate the accuracy of coordinate synchronization procedure with 5-axis milling machine for surgical template fabrication by means of reverse engineering through universal CAD software. Materials and methods: The study was performed on ten edentulous models with imbedded gutta percha stoppings which were hidden under silicon gingival form. The platform for synchordination was formed on the bottom side of models and these casts were imaged in Cone beam CT. Vectors of stoppings were extracted and transferred to those of planned implant on virtual planning software. Depth of milling process was set to the level of one half of stoppings and the coordinate of the data was synchronized to the model image. Synchronization of milling coordinate was done by the conversion process for the platform for the synchordination located on the bottom of the model. The models were fixed on the synchordination plate of 5-axis milling machine and drilling was done as the planned vector and depth based on the synchronized data with twist drill of the same diameter as GP stopping. For the 3D rendering and image merging, the impression tray was set on the conbeam CT and pre- and post- CT acquiring was done with the model fixed on the impression body. The accuracy analysis was done with Solidworks (Dassault systems, Concord, USA) by measuring vector of stopping’s top and bottom centers of experimental model through merging and reverse engineering the planned and post-drilling CT image. Correlations among the parameters were tested by means of Pearson correlation coefficient and calculated with SPSS (release 14.0, SPSS Inc. Chicago, USA) ($\alpha$ = 0.05). Results: Due to the declination, GP remnant on upper half of stoppings was observed for every drilled bores. The deviation between planned image and drilled bore that was reverse engineered was 0.31 (0.15 - 0.42) mm at the entrance, 0.36 (0.24 - 0.51) mm at the apex, and angular deviation was 1.62 (0.54 - 2.27)$^{\circ}$. There was positive correlation between the deviation at the entrance and that at the apex (Pearson Correlation Coefficient = 0.904, P = .013). Conclusion: The coordinate synchronization 5-axis milling procedure has adequate accuracy for the production of the guided surgical template.

Development of A Cyber Education Contents for the Ship Outfitting Basic Design (선박 의장 기본 모델링을 위한 사이버 교육 컨텐츠 개발)

  • Kim, Mi-Sun;Park, Yong-Suk;Lee, Sangdon;Seo, Jae-Hyun
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.2
    • /
    • pp.241-253
    • /
    • 2013
  • A Shipbuilding design program used in the shipbuilding industry tends to be shifted from the TRIBON software to the AM(AVEVA MARINE) software these days. Many large domestic shipbuilding companies have been using the AM instead of the TRIBON. New design software requires education programs for the necessary personnel. However the education programs for the AM are largely based on offline education. They suffer from constraints in space and time, and from high costs. This paper describes a development of online contents for the AM software that are focused for cyber education. It covers the applied process and the organization of the contents. The details of the development decisions including the security issue for the contents are described also.

A Study on the Representation of Ship Hull Forms Using NURBS Surface - The Development of a Free Form Cutting Machine ; Part I - (NURBS 곡면을 이용한 선형표현에 관한 연구 - 자유곡면 가공기계 개발(I) -)

  • H. Shin;K.W. Park;H.G. Park;I.H. Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.37 no.2
    • /
    • pp.109-117
    • /
    • 2000
  • In order to develope ship hull forms. many various models are represented numerically in terms of B-spline surfaces and tested experimentally in the towing tank. It is very difficult to make various ship hulls with free forms in handiwork. As the first step of development of a free form cutting machine which becomes a good substitute for high-priced model cutting machines, free forms representation for model cutting are developed. In this paper, NURBUS surfaces are represented on the assumption that data points may be control points contrary to existing methods.

  • PDF

A study on the optimal conditions for machining accuracy when endmill fillet cutting at the corner (코너부 모깍기 엔드밀가공시 가공정밀도의 최적조건에 관한 연구)

  • Choi, Sung-Yun;Kwon, Dae-Gyu;Park, In-Su;Wang, Duck-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.4
    • /
    • pp.101-108
    • /
    • 2016
  • Endmill fillet cutting at the corner was conducted with the online measurement of cutting forces and tool deflection by a tool dynamometer and an eddy current sensor system. The profile of the machined surface was also compared with the CAD profile with a Coordinate Measuring Machine (CMM) and CALYPSO software. It was found that the end mill cutter with four blades has a better surface profile than that with two blades, and the cutting forces and tool deformation were increased as the cutting speed was increased. When the tool located at the degree $45^{\circ}$ corner was found to conduct the maximum cutting force than started to the point of the workpiece. As it was compared with the CMM and ANOVA analysis result in the case that the cutting force and tool deformation was the maximum, it was found that the result was affected by the spindle speed and the number of blades.

Study on Substitution Effect caused by Application of BIM Simulation System to Mock-up Site (시공단계 현장 Mock-up의 BIM 기반 시뮬레이션 기법 적용에 의한 기대효과 분석 연구)

  • Jang, Se-Jun;Yun, Seok-Heon;Paek, Joon-Hong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.147-151
    • /
    • 2008
  • Construction project is completed through several stages and problems of each stage affect directly not only now but also next. Defect of 2D drawings influence in construction phase, and it make many loss on project. Nowadays we practically use real Mock-up test in construction sites to solve the problems. But it also has many problems which are waste much money and time. Therefore, this study tries to analyze effect that is occurred by appling BIM Mock-up simulation instead of real Mock-up execution. These analysis is conducted by comparing two construction building site. These have same shape but one is made for BIM Mock-up, and another is real Mock-up. Comparison points of view are cost, time and operator's satisfaction. It is expect that BIM Mock-up is more effective at low cost and on shorter time. But our analysis show that each are conducted different part of function. So new Mock-up type is required. Hybrid Mock-up is combine real mock-up with BIM simulation and it can minimize risk of project.

  • PDF

Structural Design and Analysis of Coiling Arm Unloading Machine for Submarine Cable (해저케이블 하역용 코일링 암 구조설계 및 해석)

  • Kim, Myung-Hwan;Kim, Dong-Hyun;Ryu, Gyeong-Joong;Sim, Jae-Park;Choo, Heon-Ho;Lee, Seung-Min
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.574-578
    • /
    • 2011
  • 본 논문에서는 해저케이블 부두 하역용 장비인 코일링 암(coiling arm)에 대한 구조설계 및 해석을 수행하였다. 본 연구에서는 구조설계를 위해 3차원 CAD프로그램을 이용하여 모델링하였고 구조해석 프로그램을 이용하여 유한요소법에 기초한 전산해석 기법으로 해석을 수행하였다. 코일링 암의 목적에 맞추어 케이블을 케이블 탱크에 가이드 할 수 있도록 베어링 및 롤러를 설계하여 메인 암이 회전하고 케이블 가이드가 이동할 수 있도록 하였고, 기존의 외국 모델에서 사용하던 와이어 및 모터 시스템을 이용한 케이블 가이드 작동방식을 유압 시스템을 이용한 작동방식으로 변경하여 설계 및 제작이 쉽고 사용자가 직관적으로 작동할 수 있도록 설계하였다. 자중 및 케이블 하중에 대한 응력 해석을 수행하였고, 유압시스템에 의한 파손 가능성을 고려하였다. 케이블 가이드에 이동 및 지면 경사도에 따른 전복해석을 수행하였으며, 설치 장소를 고려한 풍하중 효과도 추가로 고려하였다. 본 연구를 통해 코일링 암의 작동방식을 개선하였으며 설계 및 해석 방법을 확립과 더불어 국내 최초로 실제 코일링 암을 제작 및 설치하였다.

  • PDF

Development of Five Axis Laser Cutting System for the Tangent Cutting Solid Freeform Fabrication System (임의형상가공시스템을 위한 레이저 5축 경사절단기 및 궤적생성 알고리즘의 개발)

  • 주영철;엄태준;이차훈;공용해;천인국;김승우;방재철
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.1
    • /
    • pp.1-6
    • /
    • 2003
  • A novel Solid Freeform Fabrication System, which makes prototype by cutting tapes at the boundary of object and accumulating the tapes, has been developed. In order to overcome the staircase shape at the surface of prototype, the laser beam is irradiated tangent to the surface. Five axis cutting system and the tangent cutting trajectory generation algorithm have been developed.

  • PDF

Manufacturing of a Korean Hand Phantom with Human Electrical Properties at 835 MHz and 1,800 MHz Bands (835 MHz 및 1,800 MHz 대역에서 인체의 전기적 특성을 가지는 한국인 손 모양의 팬텀 제작)

  • Choi, Donggeun;Gimm, Yoonmyoung;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.5
    • /
    • pp.534-540
    • /
    • 2013
  • Interest of the hand effect on the electromagnetic wave are internationally increasing with the increase of the use of the mobile phone. IEC TC106(International Electrotechnical Commission, Technical Committee 106) promotes international research exchange program in order to reflect the effect of human hands in the standard assessment method of human exposure dosimetry by the electromagnetic wave of mobile phones. Since current commercialized hand phantom is manufactured by taking into account the average size of westerners and provides only one grip posture, it imposes many restrictions on the accurate SAR measurement. Therefore, the development of proper hand phantom accounting for domestic situation and various grip posture capability is essential in order to analyze the accurate effect of human hand on the exposure estimation. In this paper, a jelly hand phantom suitable for Korean was manufactured with various grip posture capability at 835 MHz and 1,800 MHz bands. Although the tolerances of permittivity and conductivity of the manufactured hand phantom are with ${\pm}10%$ each, it was much less than CTIA(Cellular Telecommunication Industry Association) tolerance of ${\pm}20%$ at both bands. Its 3D CAD(3 Dimensional Computer Aided Design) file which was developed can be utilized for the simulation of human hand effect on SAR measurement of mobile phones. The findings in this study can be utilized for the analysis of human hand effect on SAR measurement of a mobile phone.