• Title/Summary/Keyword: 3차원 입체모형

Search Result 56, Processing Time 0.026 seconds

A Study on the Fabrication of bone Model X-ray Phantom Using CT Data and 3D Printing Technology (CT 데이터와 3D 프린팅 기술을 이용한 뼈 모형 X선 팬텀 제작에 관한 연구)

  • Yun, Myeong Seong;Han, Dong-Kyoon;Kim, Yeon-Min;Yoon, Joon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.879-886
    • /
    • 2018
  • A 3-dimensional (D) printer is a device capable of outputting a three-dimensional solid object based on data modeled in a computer. These features are utilized in the bone model X - ray phantom production etc using CT data by fusing with the radiation science field. A bone model phantom was made using data obtained by CT scan of an existing Pelvis phantom, using PLA, Wood, XT-CF20, Glow fill, Steel filaments which are materials of Fused Filament Fabrication (FFF) 3D printer.Measure Hounsfield Unit (HU) with images obtained by CT scan of the existing Pelvis phantom and five material phantoms made with 3D printer under the same conditions,SI and SNR were measured using a diagnostic X-ray generator, and each phantom was compared and analyzed.As a result, the X - ray phantom in the X - ray examination condition of the limb was found to be most suitable for the glow fill filament.The characteristics of the filament can be known to the base of this research and the practicality of X - ray phantom fabrication was confirmed.

A Study on the Flood Inundation Analysis using Autodesk Civil 3D and HEC-RAS (Autodesk Civil 3D와 HEC-RAS를 이용한 홍수범람 해석의 연구)

  • Moon, Chang-Geon;Lee, Jung-Sik;Park, Jong-Young;Cho, Sung-Geun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1187-1191
    • /
    • 2008
  • 우리나라는 기상이변에 따른 게릴라성 집중호우의 빈도 및 강우량이 해가 거듭할수록 증가함에 따라 이로 인한 피해지역의 범위 및 피해액이 계속 증가하고 있는 실정이다. 이에 국가 및 각 연구기관들은 전국의 자연유역 및 도시유역에 대해 홍수범람의 예상지역 및 대피지도 작성 등을 통해 재해에 대한 사전 피해예방및 보험제도 등으로 그 피해를 경감하고자 각종 사업 및 연구를 활발히 진행하고 있다. 이러한 연구에 주로 이용되는 것이 지리정보시스템(GIS)으로서, 기존 수작업 과정 등을 통해 소요되는 많은 시간과 비용적 투자를 획기적으로 줄이면서도 보다 정밀도 있는 홍수범람지도를 작성하는데 크게 이바지 하고 있다. 하지만 강력하고 광범위적인 기능의 GIS 프로그램에 대한 이해 및 원시자료의 부족과 이 자료들을 이용한 실제 지형 구축 및 편집 등의 어려움으로 GIS를 이용한 홍수범람해석은 여전히 실무에서 널리 적용되지 못하고 있는 실정이다. 따라서, 본 연구에서는 실무적 적용성 및 범용성을 고려하여 자연유역이 대부분 포함되는 지방2급 고부천 유역을 대상으로 최근 토목 전반의 평면적 2D설계 개념에서 입체적 3D설계로 변화하는데 중요한 역할을 하고 있는 Autodesk사의 Civil 3D를 이용하여 수치지형도 및 측량데이터 등 다양한 원시자료로부터 실제 지형과 매우 유사한 3D 지형을 구축하고, Civil 3D의 3rd Party 프로그램인 Engineered Efficiency사의 EE HEC-RAS Tool을 이용하여 하천정비 기본계획 및 소하천정비 종합계획 등 실무에서 홍수위 계산에 가장 많이 이용되는 1차원 수치모형인 HEC-RAS와 전 후처리를 연계함으로서 빈도별 홍수위에 따른 홍수범람 수심 및 범람지역 등을 산정하였다. 본 연구는 실무 설계에서 가장 많이 이용하는 Autodesk 프로그램의 적용을 통해 기존 GIS개념 및 프로그램의 이해부족과 편집의 어려움을 해소하여 실무적 홍수범람해석에 시간적, 비용적 효율성을 높이고 기존 수작업의 오류를 보완함으로서 보다 정밀한 홍수범람해석 및 치수경제성 분석에 도움이 될 것으로 판단된다.

  • PDF

Estimating the Application Possibility of High-resolution Satellite Image for Update and Revision of Digital Map (수치지도의 수정 및 갱신을 위한 고해상도 위성영상의 적용 가능성 평가)

  • 강준묵;이철희;이형석
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.20 no.3
    • /
    • pp.313-321
    • /
    • 2002
  • Supplying high-resolution satellite image, we take much interest in the update and the revision of digital map and thematic map based on the satellite image. This study presented the possibility of the update and the revision to the existing digital map on a scale of l/5,000 and 1/25,000 to take advantage of the IKONOS satellite image. We performed geometric correction to make use of the ground control points of the existing digital map in IKONOS mono-image and created ortho-image by extracting digital elevation model from three dimensional contour data and altitude on the existing digital map. We revised changed features in the method of screen digitizing by overlapping orthorectified satellite image and existing digital map and flawed features of the unchanged area on the satellite images for positional accuracy analysis. As a result, rectification error is calculated at $\pm$3.35m by RMSE. There is a good possibility of update of digital map under the scale of 1/10,000. It is possible to the update of the large scale digital map over the scale of l/5,000, as if we used the method of stereo image and ground control point surveying.

A Study on the Advertising Creative Based on the Technology Convergence (기술융합에 기반한 광고 크리에이티브에 관한 연구)

  • Jeong, Chang Jun
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.4
    • /
    • pp.235-241
    • /
    • 2015
  • As the broadcast, tele communication and media technology develop, the media are divided into various specialities from the internet to the mobile device. An advertising creative in the field, an innovative changes are taking place that had not been in the era of the passed traditional media TV, newspaper, magazine and etc. It's not but the various media's dividing, also the consumers who use the media are evolving in their media behavior from a passive attitude to a positive one. In other words, They consumers receive the advertising messages with positive attitude to researching the message in the searching tool by themselves and participate, act, and diffuse their acknowledgements. In this thesis, as the advertising creative circumstance like this, these varied advertising creative are tried to explained by the three dimension module that is suggested in this thesis.

Analysis of Lower Somatotype on Adult Women and Appearance Analysis of Flare Skirts by using the Image Processing (성인 여성의 하반신 체형분석과 염상처리를 이용한 플레어 스커트의 외관분석)

  • Lee, Soo-Jung;Hong, Jeong-Min
    • Fashion & Textile Research Journal
    • /
    • v.1 no.3
    • /
    • pp.252-258
    • /
    • 1999
  • The aims of this study is to classify the lower somatotype of adult women and appearance analysis on the shape of flare skirts by using the image processing. Also We have made skirts in order to analyze the various types of appearance of flare skirts by using the image processing. The subjects for our wear test lower somatotype, who were controlled in their waist, abdomen and hip shapes. The flare skirts used for wear test were 112 types(combinated 14 fabric type and 8 lower somatotype). The effect of lower somatotype on the shape of flare skirts was determined by the horizontally hem line section shape and the silhouette of flare skirts with image processing. The data were analyzed by using analysis of variance and Turkey, Duncan multiple range test. The results obtained are summarized as follows: It is shown that the fabric weight elongation differs in fabrics properties, in direction of textures. The shape horizontal section of flare skirt hem line has differed with the number of nodes, wave-height of nodes and breadth of silhouette by fabrics properties and lower somatotype. It is noticed that the breadth of flare skirts by the silhouette has high correlation with the drape ability of fabrics and lower somatotype. Results for our flare skirts show changes in amplitude and mean with fabrics, somatotype. Therefore we can say that gray-level histograms are correlated with changes in appearance, differences in drape spacing and related fabric properties and their somatotype.

  • PDF

The Usability Analysis of 3D-CRT, IMRT, Tomotherpy Radiation Therapy on Nasopharyngeal Cancer (NPC의 방사선치료시 3D-CRT, IMRT, Tomotherapy의 유용성 분석)

  • Song, Jong-Nam;Kim, Young-Jae;Hong, Seung-Il
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.365-371
    • /
    • 2012
  • The radiation therapy treatment technique is developed from 3D-CRT, IMRT to Tomotherapy. and these three technique was most widely using methods. We find out a comparison normal tissue doses and tumor dose of 3D-CRT, IMRT(Linac Based), and Tomotherapy on Head and Neck Cancer. We achieved radiological image used the Human model phantom (Anthropomorphic Phantom) and it was taken CT simulation (Slice Thickness : 3mm) and GTV was nasopharngeal region and PTV(including set-up margin) was GTV plus 2mm area. and transfer those images to the radiation planning system (3D-CRT - ADAC-Pinnacle3, Tomotherapy - Tomotherapy Hi-Art System). The prescription dose was 7020 cGy and measuring PTV's dose and nomal tissue (parotid gland, oral cavity, spinal cord). The PTV's doses was Tomotherapy, Linac Based - IMRT, 3D-CRT was 6923 cGy, 6901 cGy and 6718 cGy its dose value was meet TCP because its value was up to the 95% based on 7020 cGy, Nomal tissue (parotid gland, oral cavity, spinal cord) was 1966 cGy(Tomotherapy), 2405 cGy(IMRT), 2468 cGy(3D-CRT)[parotid gland], 2991 cGy(Tomotherapy), 3062 cGy(IMRT), 3684 cGy (3D-CRT)[oral cavity], 1768 cGy(Tomotherapy), 2151 cGy(IMRT), 4031 cGy(3D-CRT)[spinal cord] its value did not exceeded NTCP. All the treatment techniques are equated with tumor and nomal tissue doses. The 3D-CRT was worse than other techniques on dose distribution, but it is reasonable in terms of TCP and NTCP baseline Tomotherapy, IMRT -dose distribution was relatively superior- was hard to therapy to claustrophobic patients and patients with respiratory failure. Particularly, in case on Tomotherapy, it take MVCT before treatment so dose measurement will be unnecessary radiation exposure to patients. Conclusion, Tomotherapy was the best treatment technique and 2nd was IMRT, and 3rd 3D-CRT. But applicable differently depending on the the patient's condition even though dose not matter.