Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
The Korean Journal of Nuclear Medicine
/
v.38
no.3
/
pp.259-267
/
2004
Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.
We compared antiobese, hypocholesterolemic, antiplatelet and antioxidant effect of 10% green tea powder and 3% green tea extract in rats pair fed 5% cholesterol diets. The final body weight was decreased significantly compared with the control (p < 0.05). Plasma and liver total cholesterol were lower in group of green tea powder or extract, but not statistically different. HDL cholesterol was increased significantly in group of green tea powder compared with the control or green tea extract (p < 0.05). Plasma triglyceride was significantly decreased in group of green tea extract compared with green tea powder, and green tea powder compared with the control respectively (p < 0.05). Liver triglyceride was significantly decreased in group of green tea powder or green tea extract compared with the control (p < 0.01). Platelet aggregations in the maximum and initial slope were not different among groups. Hemolysis was significantly lower in group of green tea powder compared with the control (p < 0.05). Plasma TBARS production was decreased in group of green tea extract compared with the control (p < 0.05). Na passive leak in intact cells was not different, but Na leak in AAPH treated cell was significantly decreased in group of green tea powder than the control (p < 0.05). The leak increase (${\Delta}Na$ Leak) after AAPH treatment was significantly decreased in groups of green tea powder and extract compared with the control (p < 0.05). Isotope excretion after $^{14}C$-cholesterol ingestion was significantly increased in group of green tea extract compared with the control or the green tea powder (p < 0.05). Consumption of green tea in powder or extract may give beneficial effects in weight control and plasma lipid profiles, impeding metabolic syndrome. More studies are needed to clarify what component of green tea and what mechanism are involved in antiobese and hypolipedemic actions of green tea.
It has been assumed that the clarification of a message is a necessary element for successful communication. However, in the today's complicated and changing environment of business marketing media, it is shown that the clarification of the message of advertisement may inhibit the effectiveness of communication. This study was to examine what was effective communication in advertisement when the company, provoking the people's negative emotional response, needs to establish new identities such as the goals and the special fields of business. In particular, the study was to investigate what effect the advertising strategy of strategically emitting ambiguous messages makes on the consumer's recognition, emotional attitude, reliability, and attitude towards the company. It was hypothesized that an ambiguous message in an advertisement has an effect on the consumer's recognition, emotional attitude, reliability, and attitude towards the company. Three texts from the 'Imagination Praises' campaign of KT&G which has been in process since 2003 were systematically sampled and the survey was performed by the means of questionnaires made on the sample The results showed that the ambiguous message of advertising texts gained better responses on the consumer's attention, good impression, affirmation, memory, sympathy than the dear message and that the ambiguous message had an effect on the consumer's attitude towards the advertisement itself. Thus, it could be tentatively concluded that the ambiguous message could be more effective in recognition and recall to promote the changes of identities of the company having the people's unfavorable emotion. But there wasn't any evidence that an ambiguous message in an advertisement was more effective in terms of the consumer's emotional response, reliability, and attitude towards the company. From this, it could be inferred that the receiver had an uncomfortable, doubtful and negative attitude about the implicit expressive code contained in the message. In the future deeper qualitative studies can compensate for the limited explanation of this empirical study focused on statistical analyses.
Objective: The purpose of this study was to provide clinical guidelines to indicate the best location for mini-implants as it relates to the cortical bone thickness and root proximity. Methods: CT images from 14 men and 14 women were used to evaluate the buccal interradicular cortical bone thickness and root proximity from mesial to the central incisor to the 2nd molar. Cortical bone thickness was measured at 4 different angles including $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, and $45^{\circ}$. Results: There was a statistically significant difference in cortical bone thickness between the second premolar/first permanent molar site, central incisor/central incisor site, between the first/second permanent molar site and in the anterior region. A statistically significant difference in cortical bone thickness was also found when the angulation of placement was increased except for the 2 mm level from the alveolar crest. Interradicular spaces at the 1st/2nd premolar, 2nd premolar/1st permanent molar and 1st/2nd permanent molar sites are considered to be wide enough for mini-implant placement without root damage. Conclusions: Given the limits of this study, mini-implants for orthodontic anchorage may be well placed at the 4 and 6 mm level from the alveolar crest in the posterior region with a $30^{\circ}$ and $45^{\circ}$ angulation upon placement.
An integral imaging system enabling enhanced depth of field by incorporating a pair of liquid-crystal (LC) lens arrays was proposed and demonstrated. The lens arrays exhibit two different refractive indexes depending on the light polarization. The proposed LC lens array I and II were implemented by depositing a ZLI-4119 LC and an E-7 LC, respectively, on top of a lens-array substrate in glass. When the two LC lens arrays were aligned appropriately, a birefringence was obtained for a specific light polarization in such a way that the incoming light sees different refractive indexes for them. As a result, the focal length associated with the imaging system utilizing the LC lens arrays was adaptively varied, thereby enhancing the depth of field for the image reconstruction. We have theoretically analyzed the proposed integral imaging system with the $LightTools^{(R)}$ to confirm that the focal length could be adjusted with the help of the birefringent lens array. Finally the proposed imaging system successfully reconstructed the objects. The birefringent lens array employing the ZLI-4119 LC produced a real image with the focal length of 680 mm, while the other using the E-7 LC yielded a virtual image with the focal length of -29 mm.
To determine the effect of chemical structure of linear amine curing agents on thermal and mechanical properties, standard epoxy resin DGEBA was cured with ethylene diamine(EDA) and hexamethylene diamine(HMDA) in a stoichiometrically equivalent ratio. From this work, the effect of linear amine curing agents on the thermal and mechanical properties is significantly influenced by the chemical structure or chain length of curing agents. In contrast, the results show that the DGEBA/EDA system having the two carbons had higher values in the thermal stability, maximum conversion of epoxide, density, glass transition temperature, tensile modulus, flexural strength, and flexural modulus than the DGEBA/HMDA system having the six carbons, whereas the DGEBA/EDA cure system had relatively low values in the shrinkage(%), thermal expansion coefficient, tensile strength, and had similar values in the maximum exothermic temperature, and conversion of epoxide compared to the DGEBA/HMDA cure system. This findings indicate that packing ability in the HMDA structure affects the thermal and mechanical properties.
Journal of the Korean Crystal Growth and Crystal Technology
/
v.12
no.5
/
pp.240-246
/
2002
$TiO_2$ films on soda-lime-silica glasses were prepared by spin coating-pyrolysis process using titanium naphthenate as a starting material. As-deposited films were pyrolyzed at $500^{\circ}C$ for 10 min in air and annealed at 500, 550 and $600^{\circ}C$ for 30 min in air. Crystallinity of the film was investigated by X-ray diffraction analysis. A field emission-scanning electron microscope and an atomic force microscope were used for characterizing the surface morphology and the surface roughness of the film. After annealing at 550 and $600^{\circ}C$, the X-ray diffraction patterns consist of only anatase peak. Films annealed at 500 and $550^{\circ}C$ exhibited flat surfaces. While with the increase in annealing temperature to $600^{\circ}C$, the $TiO_2$ film showed abnormal growth of three-dimensional needle-shaped grains. For all samples, high transmittance, above 90 % at 500 nm, was obtained at visible range. To investigate photocatalytic properties, IR absorbance associated with the C-H stretching vibrations of a thin solution-cast film of stearic acid under 365 nm (2.4 mW/$\textrm{cm}^2$) UV irradiation was estimated.
By supply of high performance computer becomes all industries automation and convenient of our life. Can speak that is pursuit of swiftness and variety that is prior most development of information society and production system in competitive industrial design product development process. Specially, students who consumer personality studies design according to variableness must present idea in a short time. Therefore, find a new tool that can show quick modeling result for present of new idea or fast design specifications examination and production at college or corporation now. According to such environment change did request by cost time and cost-cutting until reach in production from product design because competition is gone vigorously. University arrived to think RP induction by result presentation and so on for third dimension model by various design process. This research purpose is going to compare difference methods(Manual processing, CNC machine) with students' design result manufacture process on RP appliance that is using in college. Consequently, think that this study is helpful in the college of which is making use of RP appliance or planning installation. By result of this research, model of big curved line is profitable in hand process, by CNC Is profitable when model is going to manufacture finely, RP work could know that size of product is profitable small thing as is complicated.
Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
/
2007.11a
/
pp.39-39
/
2007
원자층 증착(Atomic Layer Deposition: ALD) 방법은 반응물질들을 펄스형태로 챔버에 공급하여 기판표면에 반응물질의 표면 포화반응에 의한 화학적 흡착과 탈착을 이용한 박막증착기술이다. ALD법은 기존의 화학적 기상증착(Chemical Vapor Deposition: CVD)과 달리 자기 제한적 반응(self-limiting reaction) 에 의하여 반응가스가 기판 표면에서만 반응하고 가스와 가스 간에는 반응하지 않는다. 따라서 박막의 조성 정밀제어가 쉽고, 파티클 발생이 없으며, 대면적의 박막 증착시 균일성이 우수하고, 박막 두께의 정밀 조절이 용이한 장점이 있다. 이러한 ALD 방식으로 3차원의 반도체 장치 구조물에 산화막 등을 형성하는 공정에서 중요한 요소 중의 하나는 전구체의 충분한 공급이다. 따라서 증기압이 높은 전구체를 선호하는 경향이 있다. 그러나 증기압이 낮은 전구체를 사용할 경우, 공급량이 부족하여 단차 도포성(step coverage)이 떨어지는 문제가 있다. 원자층 증착 공정에서 전구체를 충분히 공급하기 위해전구체 온도를 증가시키거나 전구체의 공급시간을 늘리는 방법을 사용한다. 그러나 전구체 온도를 상승시키는 경우, 전구체의 변질이나 수명을 단축시키는 문제점을 발생시킬 수 있으며. 전구체를 충분히 공급하기 위하여 전구체의 공급시간을 늘이는 방법을 사용하면, 원하는 박막을 형성하기 위하여 소요되는 공정시간과 전구체 사용량이 증가된다. 본 논문에서는 이러한 문제점을 해결하기 위해 반응기 안에서 전구체 노출 시간을 조절하는 새로운 ALD 공정을 소개한다. 특히 이러한 기술을 적용하면 나노튜브를 성장시키는데 매우 유리하다. 본 연구에서 전구체 노출 시간을 조절하기 위하여 사용된 ALD 장비는 Lucida-D200-PL (NCD Technology사)이며 (TEMA)Zr와 H2O를 사용하여 ZrO2 나노튜브를 폴리카보네이트 위에 성장시켰다. 전구체의 노출 시간은 반응기의 Stop 밸브를 이용하여 조절하였으며, SEM, TEM 등을 이용하여 나노튜브의 균일성과 단차피복성 등의 특성을 관찰하였다. 그 결과 전구체 노출시간을 조절함으로써 높은 종횡비를 갖는 나노튜브를 성장 시킬 수 있음을 확인하였다. 또한 낮은 증기압을 가지는 전구체를 이용하여도 우수한 특성의 나노튜브를 균일하게 성장시킬 수 있었다.
Bae, Sung Geun;Choi, Seongcheol;Jang, Seung Yup;Cha, Soo Won
Journal of the Korean Society for Railway
/
v.17
no.5
/
pp.355-364
/
2014
The restrained volume changes of concrete due to variations of temperature and moisture produce transverse cracks in continuously reinforced concrete tracks (CRCTs). Such cracks are known to significantly affect the behaviors and long-term performance of CRCT. To investigate the effects of the transverse cracks on the behavior of CRCT and to develop more reasonable maintenance standards for cracks, in this study, the stress distribution of the track concrete layers (TCL) and the hydraulically stabilized base course (HSB) with transverse cracks were numerically predicted by a three dimensional finite element analysis when CRCT was subjected to train loads. The results indicate that the bending stresses of TCL and vertical stresses at the interfaces between TCL and HSB increased as the cracks were deepened. In addition, vertical stresses were locally concentrated near reinforcing steel in cracks in TCL when full-depth cracks developed, which may lead to punch-outs in CRCTs. Comparably, the effects of crack width and spacing were not as significant as crack depth. This study indicates that ensuring the long-term performance of CRCTs requires adequate maintenance not only for crack width and spacing but also for crack depth. Our results also show that locating HSB joints between sleepers is beneficial to the long-term performance of CRCTs.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.