• Title/Summary/Keyword: 3차원 기구

Search Result 251, Processing Time 0.028 seconds

3-D Form Generation Mechanism in the Centerless Grinding Process (I) -Infeed Grinding- (무심 연삭 공정의 3차원 형상화기구 (I) -인피드 연삭-)

  • Kim, Kang;Joo, Jong-Nam
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.5
    • /
    • pp.128-136
    • /
    • 1998
  • A mathematical model for investigating the form generation mechanism in the centerless infeed grinding process is described. For 3-D modeling of form generation, contact points are assumed to be on least squares contact lines at the grinding wheel, regulating wheel, and work-rest blade. Using force and deflection analysis, the validity of this assumption is shown. Based on the 2-D simulation model developed in the previous work and the least squares contact line assumption, a 3-D model is presented. To validate this model, simulation results were compared with the experimental works. The experiments and computer simulations were carried out using three types of cylindrical workpiece shapes with varying flat length. The experimental results agree well with the simulation. It can be seen that the effect of flat end propagated to the opposite end through workpiece reorientation.

  • PDF

A study on the density analysis of climatological stations using the correlation integral method in the fractal dimension (상관적분 기법의 프랙탈 차원 추정을 통한 기후관측소 밀도 분석에 관한 연구)

  • Kim, Hee-Kyung;Lee, Yung-Seop
    • Journal of the Korean Data and Information Science Society
    • /
    • v.24 no.1
    • /
    • pp.53-62
    • /
    • 2013
  • Currently we have 11 climatological stations registered in World Meteorological Organization. Geographically, these stations are unevenly distributed in Korea and are mainly located on seaside. Therefore station's density analysis should be performed to produce the high-quality climatological data. Using the correlation integral method, the density of climatological stations can be measured by the estimation of fractal dimension. In this study, new climatological stations having the higher fractal dimension were selected. Sequential or simultaneous selection method were carried out until 3 new stations were selected based on the fractal dimension.

Development of Conformal Radiotherapy with Respiratory Gate Device (호흡주기에 따른 방사선입체조형치료법의 개발)

  • Chu Sung Sil;Cho Kwang Hwan;Lee Chang Geol;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.41-52
    • /
    • 2002
  • Purpose : 3D conformal radiotherapy, the optimum dose delivered to the tumor and provided the risk of normal tissue unless marginal miss, was restricted by organ motion. For tumors in the thorax and abdomen, the planning target volume (PTV) is decided including the margin for movement of tumor volumes during treatment due to patients breathing. We designed the respiratory gating radiotherapy device (RGRD) for using during CT simulation, dose planning and beam delivery at identical breathing period conditions. Using RGRD, reducing the treatment margin for organ (thorax or abdomen) motion due to breathing and improve dose distribution for 3D conformal radiotherapy. Materials and Methods : The internal organ motion data for lung cancer patients were obtained by examining the diaphragm in the supine position to find the position dependency. We made a respiratory gating radiotherapy device (RGRD) that is composed of a strip band, drug sensor, micro switch, and a connected on-off switch in a LINAC control box. During same breathing period by RGRD, spiral CT scan, virtual simulation, and 3D dose planing for lung cancer patients were peformed, without an extended PTV margin for free breathing, and then the dose was delivered at the same positions. We calculated effective volumes and normal tissue complication probabilities (NTCP) using dose volume histograms for normal lung, and analyzed changes in doses associated with selected NTCP levels and tumor control probabilities (TCP) at these new dose levels. The effects of 3D conformal radiotherapy by RGRD were evaluated with DVH (Dose Volume Histogram), TCP, NTCP and dose statistics. Results : The average movement of a diaphragm was 1.5 cm in the supine position when patients breathed freely. Depending on the location of the tumor, the magnitude of the PTV margin needs to be extended from 1 cm to 3 cm, which can greatly increase normal tissue irradiation, and hence, results in increase of the normal tissue complications probabiliy. Simple and precise RGRD is very easy to setup on patients and is sensitive to length variation (+2 mm), it also delivers on-off information to patients and the LINAC machine. We evaluated the treatment plans of patients who had received conformal partial organ lung irradiation for the treatment of thorax malignancies. Using RGRD, the PTV margin by free breathing can be reduced about 2 cm for moving organs by breathing. TCP values are almost the same values $(4\~5\%\;increased)$ for lung cancer regardless of increasing the PTV margin to 2.0 cm but NTCP values are rapidly increased $(50\~70\%\;increased)$ for upon extending PTV margins by 2.0 cm. Conclusion : Internal organ motion due to breathing can be reduced effectively using our simple RGRD. This method can be used in clinical treatments to reduce organ motion induced margin, thereby reducing normal tissue irradiation. Using treatment planning software, the dose to normal tissues was analyzed by comparing dose statistics with and without RGRD. Potential benefits of radiotherapy derived from reduction or elimination of planning target volume (PTV) margins associated with patient breathing through the evaluation of the lung cancer patients treated with 3D conformal radiotherapy.

Performance analysis of the HEVC based 3DV Coding (HEVC 기반 3DV 부호화 성능 분석)

  • Park, Dae-Min;Son, So-Hee;Choi, Haechul
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2014.11a
    • /
    • pp.214-215
    • /
    • 2014
  • 3차원 비디오 부호화를 위한 표준안을 제정하기 위해 국제 표준화 기구인 JCT-3V(Joint Collaborative Team on 3D Video Coding Extension Development)에서는 3차원 비디오 부호화기술에 대한 표준화가 진행되고 있다. 본 논문은 현재 JCT-3V에서 HEVC(High Efficiency Video Coding) 기반으로 표준화가 진행 중인 3D-HEVC 부호화 기술들에 대해 살펴보고 그 부호화 및 복잡도 성능을 분석하였다. 이러한 성능 분석은 향후 3D-HEVC 기술에 대한 알고리즘 개발을 위한 기술 선별 및 조정에 유용할 것으로 판단된다.

  • PDF

Study on 3D Printer Production of Auxiliary Device for Upper Limb for Medical Imaging Test (의료영상 검사를 위한 상지 보조기구의 3D 프린터 제작 연구)

  • Kim, Hyeong-Gyun;Yoon, Jae-Ho;Choi, Seong-Dae
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.389-394
    • /
    • 2015
  • There is a progressive development in the medical imaging technology, especially of descriptive capability for anatomical structure of human body thanks to advancement of information technology and medical devices. But however maintenance of correct posture is essential for the medical imaging checkup on the shoulder joint requiring rotation of the upper limb due to the complexity of human body. In the cases of MRI examination, long duration and fixed posture are critical, as failure to comply with them leads to minimal possibility of reproducibility only with the efforts of the examiner and will of the patient. Thus, this study aimed to develop an auxiliary device that enables rotation of the upper limb as well as fixing it at quantitative angles for medical imaging examination capable of providing diagnostic values. An auxiliary device has been developed based on the results of precedent studies, by designing a 3D model with the CATIA software, an engineering application, and producing it with the 3D printer. The printer is Objet350 Connex from Stratasys, and acrylonitrile- butadiene-styrene(ABS) is used as the material of the device. Dimensions are $120{\times}150{\times}190mm$, with the inner diameter of the handle being 125.9 mm. The auxiliary device has 4 components including the body (outside), handle (inside), fixture terminal and the connection part. The body and handle have the gap of 2.1 mm for smooth rotation, while the 360 degree of scales have been etched on the handle so that the angle required for observation may be recorded per patient for traceability and dual examination.

Fuzzy Control and Implementation of a 3-Dimensional Inverted Pendulum System (3차원 도립진자 시스템의 구현 및 퍼지 제어)

  • Shin, Ho-Sun;Chu, Jun-Uk;Lee, Seung-Ha;Lee, Yun-Jung
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.13 no.2
    • /
    • pp.137-147
    • /
    • 2003
  • The fuzzy control and implementation of a new three-dimensional(3-D) inverted pendulum system are addressed. In comparison with conventional 1-D and 2-D systems, the 3-D inverted pendulum system is a proper benchmark system to simulate human's control action which includes the up and down motion to stabilize an inverted pendulum. To investigate the characteristics of the 3-D inverted pendulum system and to design of a fuzzy controller, we derive dynamic equations of the mechanism including a 3-axis cartesian robot and an inverted pendulum. We propose a design method of a fuzzy controller of the yaw and pitch angles of an inverted pendulum. In the design, the redundant degree-of-freedom(DOF) of the robot and the constrained workspace are taken into account. The performance of the proposed system is proved by experimental results using a developed PC-based Multi-Motion Control(MMC) board.

A development of quadruped walking robot with 3-D orthogonal legs using pantograph mechanism (팬터그라프 기구를 이용한 3차원 수직 직교형 다리 기구를 가진 4각 보행로봇의 개발)

  • 김인준;정경민
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1593-1596
    • /
    • 1997
  • Because the leg mechanism of walking roblt affect on the mobility and energy efficiency, we focus on the design of new leg mechanism based on the previous leg mechanisms. We mention the deficiency of the previous leg mechanisms and propose a new leg mechanism that consists of a 2-d.o.f pantograph mechanism and a vertical linear actuator. The pantograph mechanism is attached to the horizontal plane of the body and the verical linear actuator is vertical to that plane. In order to design a quadruped walking robot, we consider the kinematics of the 2-d.o.f pantograph mechanism and the arrangement of twol linear motion guides that drive the pantograph mechanism.

  • PDF

3-D Form Generation Mechanism in the Centerless Grinding Process (II) -Thrufeed Grinding- (무심 연삭 공정의 3차원 형상화기구 (II) -관통 연삭-)

  • Kim, Kang;Joo, Jong-Nam
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.5
    • /
    • pp.137-144
    • /
    • 1998
  • A mathematical model for investigating the form generation mechanism in the centerless thrufeed grinding process is described. The length of the contact line and the magnitude of the grinding force between the grinding wheel and workpieces vary with the change of the axial location of the current workpiece during grinding. Thus, a new coordinate system and a grinding force curve of previous and/or following workpieces are introduced to treat the axial motion. Experiments and computer simulations were carried out using three types of cylindrical workpiece shapes. To validate this model. simulation results are compared with the experimental results.

  • PDF

Effect of Link Stiffness on Error of Cubic Parallel Manipulator in 3D Workspace (3차원 작업영역에서 링크 강성이 육면형 병렬 기구 오차에 미치는 영향)

  • 박성철;임승룡;김현수;최우천;송재복
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.397-401
    • /
    • 1997
  • An error analysis is very important for a precision machine to estimate its performances. This study deals with error of a new parallel device, cubic parallel manipulator. There are so many error sources in this mechanism. Errors of the cubic parallel device vary depending on the stiffness of the manipulator. The stiffness of each link depends on the directions of the link and actuation force. In this paper, the stiffness of the manipulator is calculated by ARAQUS and the position and orlentation errors are predicted within a given workspace. The analysis shows that the method can be used in predicting the accuracy of other parallel devices and in designing parallel devices.

  • PDF

Precision Evaluation Method for the Positioning Error of Three-DOF Parallel Mechanism using Coordinate Measuring Machine (CMM) (CMM을 이용한 3자유도 병렬기구 위치 오차의 정밀 평가 기법)

  • 권기환;박재준;이일규;조남규;양현익
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.11
    • /
    • pp.99-109
    • /
    • 2004
  • This paper proposes precision evaluation method for the positioning error of three-DOF translational parallel mechanism. The proposed method uses conventional CMM as metrology equipment to measure the position of end-effector. In order to obtain accurate measurement data from CMM, the transform relationship between the coordinate system of the parallel mechanism and the CMM coordinate system must be identified. For this purpose, a new coordinate referencing (or coordinate system identification) technique is presented. By using this technique accurate coordinate transformation relationships are efficiently established. According to these coordinate transformation relationships, an equation to calculate error components at any arbitrary position of the end-effector is derived. In addition, mathematical fitting models to represent the position error components in the two-dimensional workspace of the parallel mechanism are also constructed based on response surface methodology. The proposed error evaluation method proves its effectiveness through the experimental results and its application to real three-DOF parallel mechanism.