• Title/Summary/Keyword: 3차원 건물 모델

Search Result 189, Processing Time 0.025 seconds

Automatic Generation of 3D Building Models using a Draft Map (도화원도를 이용한 3차원 건물모델의 자동생성)

  • Kim, Seong-Joon;Min, Seong-Hong;Lee, Dong-Cheon;Park, Jin-Ho;Lee, Im-Pyeong
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.15 no.2 s.40
    • /
    • pp.3-14
    • /
    • 2007
  • This study proposes an automatic method to generate 3D building models using a draft map, which is an intermediate product generated during the map generation process based on aerial photos. The proposed method is to generate a terrain model, roof models, and wall models sequentially from the limited 3D information extracted from an existing draft map. Based on the planar fitting error of the roof corner points, the roof model is generated as a single planar facet or a multiple planar structure. The first type is derived using a robust estimation method while the second type is constructed through segmentation and merging based on a triangular irregular network. Each edge of this roof model is then projected to the terrain model to create a wall facet. The experimental results from its application to real data indicates that the building models of various shapes in wide areas are successfully generated. The proposed method is evaluated to be an cost and time effective method since it utilizes the existing data.

  • PDF

Creation of 3D Images using DEM and a Satellite Image (단일 고해상도 위성영상과 수치지도를 이용한 3차원 영상 생성)

  • Park, Hyun-Ju;Shin, Sung-Sik;Gwoun, Ou-Bong
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2010.06b
    • /
    • pp.279-282
    • /
    • 2010
  • 최근 단일 고해상도 위성영상과 건물과 지형에 대한 정보를 가지고 있는 수치지도(DEM:Digital Elevation Model)를 이용하여 3차원 영상으로 구축하는 연구가 많이 이루어지고 있다. 3차원영상을 구축하기 위해서는 건물과 지형의 위치, 크기, 형상에 관한 정보가 필요하나 위성영상만으로는 구하기가 어려워 수치지도를 활용한다. 본 논문에서는 수치지도를 이용하여 3차원 건물과 지형의 고도 정보를 추출하고, 위성영상과 Snake 모델을 이용하여 반자동으로 추가적인 건물 높이와 바닥면에 대한 정보를 추출하여, 3차원 영상을 생성 하는 방법을 제안한다.

  • PDF

3D urban model generation from single high resolution satellite image (단일 고해상도 위성영상으로부터 3차원 도시 모델 생성)

  • Lee, Tae-Yoon;Kim, Tae-Jung
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2008.10a
    • /
    • pp.16-17
    • /
    • 2008
  • 최근 3차원 도시 모델의 활용이 증가하고 있다. 본 논문에서는 단일 고해상도 위성영상으로부터 3차원 도시 모델을 생성하는 연구를 수행하였다. 3차원 도심 모델은 크게 인공지물 정보와 지형정보가 필요하다. 본 연구에서 인공지물 정보는 단일 고해상도 위성영상으로부터 건물의 그림자를 이용한 방법으로 추출하였으며, 지형정보는 기존에 구축된 수치지도로부터 수치표고자료를 생성하여 적용하였다.

  • PDF

A Study on Position Matching Technique for 3D Building Model using Existing Spatial Data - Focusing on ICP Algorithm Implementation - (기구축 공간데이터를 활용한 3차원 건물모델의 위치정합 기법 연구 - ICP 알고리즘 구현 중심으로 -)

  • Lee, Jaehee;Lee, Insu;Kang, Jihun
    • Journal of Cadastre & Land InformatiX
    • /
    • v.51 no.1
    • /
    • pp.67-77
    • /
    • 2021
  • Spatial data is becoming very important as a medium that connects various data produced in smart cities, digital twins, autonomous driving, smart construction, and other applications. In addition, the rapid construction and update of spatial information is becoming a hot topic to satisfy the diverse needs of consumers in this field. This study developed a software prototype that can match the position of an image-based 3D building model produced without Ground Control Points using existing spatial data. As a result of applying this software to the test area, the 3D building model produced based on the image and the existing spatial data show a high positional matching rate, so that it can be widely used in applications requiring the latest 3D spatial data.

Extracting Building Geometry for Structural Analysis from IFC Physical File (IFC 파일로부터 구조해석을 위한 형상모델의 구축)

  • Goh, IL-Du;Choi, Joong-Hyun;Kim, E-Doo;Jeong, Yeon-Suk;Lee, Jae-Min
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.601-604
    • /
    • 2010
  • 기하형상이나 엔지니어링에 관한 정보를 3차원 모델기반으로 다루는 BIM기술은 기존의 2차원 도면작업들에 비해 업무의 효율성이나 신속성, 비용측면 등에서 많은 이점을 제공할 수 있어 건축계획 및 설계, 엔지니어링, 시공, 유지관리, 에너지분석 등 건설산업의 전 분야에 활용되고 있다. 본 논문은 BIM용 프로그램들간에 정보교환을 위해 사용되는 건물의 국제표준 정보모델인 IFC 파일로부터 구조해석을 위한 건물형상모델을 자동으로 구축하기 위한 방법을 제시하고, 실제 구현한 프로그램으로 적용사례를 보여준다.

  • PDF

Application of Library-Based Texture Mapping Method (라이브러리 기반의 Texture Mapping 기법 활용연구)

  • Song Jeong-Heon;Park Su-Yong;Lim Hyo-Suk;Kim Yong-Il
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2006.04a
    • /
    • pp.369-373
    • /
    • 2006
  • A 3D modeling of urban area can be composed the terrain modeling that can express specific and shape of the terrain and the object modeling such as buildings, trees and facilities which are found in urban areas. Especially in a 3D modeling of building, it is very important to make a unit model by simplifying 3D structure and to take a texture mapping, which can help visualize surface information. In this study, the texture mapping technique, based on library for 3D urban modeling, was used for building modeling. This technique applies the texture map in the form of library which is constructed as building types, and then take mapping to the 3D building frame. For effectively apply, this technique, we classified buildings automatically using LiDAR data and made 3D frame using LiDAR and digital map. To express the realistic building texture, we made the texture library using real building photograph.

  • PDF

A Study on the Derivation of Items for Development of Data Quality Standard for 3D Building Data in National Digital Twin (디지털 트윈국토 건물 데이터 품질 표준 개발을 위한 항목 도출에 관한 연구)

  • Kim, Byeongsun;Lee, Heeseok;Hong, Sangki
    • Journal of Cadastre & Land InformatiX
    • /
    • v.52 no.1
    • /
    • pp.37-55
    • /
    • 2022
  • This study presents the plans to derive quality items for develop the data quality standard for ensuring the quality of 3D building geospatial data in NDT(National Digital Twin). This paper is organized as follows. The first section briefly examines various factors that impact the quality of 3D geospatial data, and proposes the role and necessity of the data quality standard as a means of addressing the data errors properly and also meeting the minimum requirements of stakeholders. The second section analyzes the relationship between the standards - building data model for NDT and ISO 19157: Geospatial data quality - in order to consider directly relevant standards. Finally, we suggest three plans on developing NDT data quality standard: (1) the scope for evaluating data quality, (2) additional quality elements(geometric integrity, geometric fidelity, positional accuracy and semantic classification accuracy), and (3) NDT data quality items model based on ISO 19157. The plans reveled through the study would contribute to establish a way for the national standard on NDT data quality as well as the other standards associated with NDT over the coming years.

Experimental Study on the Active Controller of Structures Considering Modeling Uncertainty (구조물의 모델링 불확실성을 고려한 능동 제어기의 실험연구)

  • 민경원;김성춘
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.4
    • /
    • pp.53-61
    • /
    • 2000
  • 능동 제어기를 설계하기 위해서는 제어대상 구조물의 수학모델의 구해야한다. 그러나, 무한차원의 구조물에 대하여 정확한 모델을 구하는 것은 불가능하므로 유한차원인 저차원화된 모델을 사용하여 제어기를 설계한다. 그러나, 실제 구조물과 저차원화된 모델사이의 오차에 의하여 제어기의 성능이 저하가 되면 제어기와 구조물의 상호작용, 지진과 같은 오란 등의 불확실성, 지진시 구조물의 동적 특성 변화로 인하여 제어기의 성능이 더욱 저하가 된다. 이러한 저하 요인은 제어기 설계시 요구되는 구조물의 수학모델에 대한 불확실한 요소로 작용하기 때문에 제어성능의 저하를 일으키며 응답의 불안정을 유발하기로 한다. 본 연구에서는 질량형 능동제어기(AMD)가 설치된 3층 건물 모형의 모델 오차에 관한 불확실성을 반영한 강인제어기법을 적용하여 제어성능과 안정성을 실험을 통하여 분석하였다. 강인제어 기법인 $\mu$ 합성법에 요구되는 여러 가지 가중함수인 주파수필터는 건물과 AMD의 특성, 모델 오차, 제어율과 AMD 성능의 , 측정잡음 및 지진외란의 특성 등을 고려하여 정량적으로 선택되었다. $\mu$합성법에 의하여 제어기를 설계하였으며 강인성을 비교하기 위하여 불확실성이 고려되지 않는 LQG 기법에 의한 제어기를 선택하였다. $\mu$합성법은 규정된 불확성에 대하여 제어의 강인성을 가지므로 동적특성이 바뀐 건물모형에 관한 강인성을 LQG 기법에 의한 제어성능과 비교하였다. 그 결과 동적특성이 변화된 건물에 대하여 $\mu$합성법만이 제어의 효율성이 유지되는 강인성을 나타내었다.

  • PDF

Three-Dimensional Structural Analysis System for Nuclear Containment Building (원자로 격납건물의 3차원 구조해석시스템)

  • Kim, Sun-Hoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.2
    • /
    • pp.235-243
    • /
    • 2010
  • Three-dimensional structural analysis system for nuclear containment building is presented in this paper. This system includes high-performance plate/shell elements as finite element library. It also adopts numerical modeling technique for unbonded tendon as well as bonded tendon in prestressed concrete structures. This system is constructed by connecting several in-house program to a commercial program DIANA, and then is capable of performing nonlinear analysis for ultimate pressure capacity of nuclear containment building. Finally, three-dimensional structural analysis of CANDU-type containment building is carried out in order to test the reliability of this system. These numerical results are compared with reference values, which obtained from axisymmetric structural analysis.

(A) study on location correction method of indoor/outdoor 3D model through data integration of BIM and GIS (BIM과 GIS 데이터 융합을 통한 실내외 3차원 모델 위치보정 방안 연구)

  • Kim, Ji-Eun;Hong, Chang-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.56-62
    • /
    • 2017
  • As the need for 3D spatial information increases, many local governments and related industries are establishing map-based 3D spatial information services and offering them to users. In these services, positional accuracy is one of the most important factors determining their applicability to specific tasks. This study studied the location correction method between indoor and outdoor 3D spatial information through the construction of modeling data on a BIM/GIS platform. First, we selected the sites and processed the BIM/GIS data construction with 3 steps. When connecting the BIM model including indoor spatial data and 3D texturing model based on ortho images, mismatches occurred, so we proposed a location correction method. Using the conversion algorithm, the relative coordinate-based BIM data were converted to the absolute positions and then relocated by means of the texturing data on the BIM/GIS platform.