• Title/Summary/Keyword: 3차원유한차분해석

Search Result 172, Processing Time 0.028 seconds

FDTD Modeling of the Korean Human Head using MRI Images (MRI 영상을 이용한 한국인 인체 두부의 FDTD 모델링)

  • 이재용;명노훈;최명선;오학태;홍수원;김기회
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.4
    • /
    • pp.582-591
    • /
    • 2000
  • In this paper, the Finite-Difference Time-Domain(FDTD) modeling method of the Korean human head is introduced to calculate electromagnetic energy absorption for the human head by mobile phones. After MRI scanning data is obtained, 2 dimensional(2D) segmentation is done from the 2D MRI image data by the semi-automatic method. Then, 3D dense segmentation data with $1mm\times1mm\times1mm$ is constructed from the 2D segmentation data. Using the 3D segmentation data, coarse FDTD models of human head that is tilted arbitrarily to model the condition of tilted usage of mobile phone.

  • PDF

Numerical simulation for surface settlement considering face vibration of TBM tunnelling in mixed-face condition (복합지반에서 TBM 굴진 진동을 고려한 지표침하에 대한 수치모델링)

  • Kwak, Chang-Won;Park, Inn-Joon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.333-339
    • /
    • 2015
  • In this paper, the surface settlement resulted from the shallow TBM tunnelling has been numerically simulated. TBM tunnelling is especially used in urban area to avoid serious vibration and noise caused by explosion in NATM. Surface settlement is one of the most important problems encountered in all tunnelling and critical in urban areas. In this study, face vibration of TBM excavation is considered to estimate surface settlement trend according to TBM extrusion. The dynamic excavation forces are calculated by total torque on the TBM cutterhead in mixed-face of soil and weathered rock condition with shallow depth. A 3-dimensional FDM code is employed to simulate TBM tunnelling and mechanical-dynamic coupling analysis is performed. The 3D numerical analysis results showed that dynamic settlement histories and trend of surface settlement successfully. The maximum settlement occurred at the excavation point located at 2.5D behind the face, and the effect of face vibration on the surface settlement was verified in this study.

An FDTD Analysis of EMP problems with the Aperture on Metal Shields (FDTD에 의 한 금속차폐의 개구면을 통한 전파침투 연구)

  • Ju, Jeong-Ho;Jang, Geon-Ho;Kahng, Sung-Tek;Kim, Hyeong-Seok
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.238-240
    • /
    • 2007
  • 본 논문에서는 전자기파 산란 문제를 해석하는데 있어서 중요한 기법의 하나인 유한 차분 시간영역 해석방법(FDTD : Finite-Difference Time-Domain Method)을 이용하여 금속 차폐구조의 틈새인 개구를 통한 EMC 문제를 중점적으로 다루었다. 이와같은 3차원 FDTD를 이용한 전자파 산란 문제의 해석을 통한 연구는 통신 시스템의 차폐 방안과 전자파 내부침투 문제 해결을 위한 중요한 기반 작업이 될 것으로 기대된다.

  • PDF

Calculation of Pixel and Inter-Electrode Capacitance of In-Plane Switching Liquid Crystal Displays using Three-dimensional Simulation

  • Park, Woo-Sang;Jung, Sung-Min;Jang, Sang-Han
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.739-742
    • /
    • 2003
  • 본 연구에서는 정전계 에너지를 이용하여 IPS-LCD의 화소와 각 전극간 정전용량을 엄정한 방법으로 계산하였다. 정전계 에너지는 전극의 유한한 크기로 인해 발생하는 측면 전장효과를 고려한 3차원 방향자와 전위분포를 시뮬레이션 함으로써 얻을 수 있었다. 수치해석 방법으로는 유한차분법을 사용하였다. 그 결과 IPS-LCD의 화소 정전용량과 게이트-공통전극간 정전용량은 구조적 특성으로 인해 기존의 TN-LCD와 비교하여 1/16배 가량으로 훨씬 더 작은 값을 나타냄이 확인되었다.

  • PDF

Effectiveness of the Electrode Arrays for Delineating 2-D Subsurface Structure (2차원 지하구조 규명을 위한 전극배열의 효율성)

  • Yoon, Jong-Ryeol;Lee, Kiehwa
    • Economic and Environmental Geology
    • /
    • v.29 no.3
    • /
    • pp.345-355
    • /
    • 1996
  • The effectiveness of various electrode configurations in horizontal mappings and 1-D inversions of vertical sounding data for delineating 2-D structures was studied. Apparent resistivity values of three point, dipole-dipole, Wenner, and Schlumberger mappings were simulated for such structures as vertical dyke, tabular prism, buried vertical fault, ramp and complex structure by finite difference method (FDM) and they were compared with each other. Also 2-D cross sections for three structures obtained by interpolation of 1-D inverted sounding data in terms of three layers were compared for Schlumberger and Wenner arrays. On these cross sections, horizontal and vertical resistivity interfaces of the 2-D structures are revealed relatively clearly. Apparent resistivity curves of Schlumberger mapping show vertical resistivity discontinuities very well. On the whole, Schlumberger array is superior to the other arrays in electric sounding as well as mapping. This study clearly indicates that interpretations of 2-D structures based on 1-D inversion are possible.

  • PDF

A Study on the Transport of Soil Contaminant (A Development of FDM Model for 3-D Advection-Diffusion Equation with Decay Term) (토양 오염원의 이동에 관한 연구 (감쇠항이 있는 3차원 이송-확산 방정식의 수치모형 개발))

  • Kim, Sang-Jun
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.2
    • /
    • pp.179-189
    • /
    • 2012
  • To simulate the transport of pollutant, a numeric model for the advection-diffusion equation with the decay term is developed. This is finite-difference model using the implicit method (with the weight factor ${\alpha}$) and Gauss-Seidel SOR(successive over-relaxation). This model is compared to the analytical solutions (of simpler dimensional or boundary conditions), and in the condition of Peclet number < 5~20, the result shows stable condition, and Crank-Nicolson method (${\alpha}$=0.5) shows the more accurate results than fully-implicit method (${\alpha}$=1). The mass of advection, diffusion and decay is calculated and the error of mass balance is less than 3%. This model can evaluate the 3-D concentrations of the advection-diffusion and decay problems, but this model uses only the finite-difference method with the fixd grid system, so it can be effectively used in the problems with small Peclet numbers like the pollutant transport in groundwater.

The Effects of Tidal Currents and Residual Flow on the Sea Dike (해안방조제가 조류 및 잔류흐름에 미치는 영향)

  • Park, Joong-Cheol;Yoon, Young-Ho;Shin, Moon-Seup;Manh, Dinh-Van
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.1
    • /
    • pp.83-96
    • /
    • 2005
  • Three-dimensional hydrodynamic numerical simulation is carried out to investigate the effects of the coastal land reclamation on the marine hydrodynamics, environment and ecosystem. The changes of tide, tidal currents and residual currents, including tide-induced, wind driven and density driven components due to the construction of the sea dike system are simulated numerically The governing equations transformed into o-coordinates are solved by an implicit finite difference method. The numerical model is calibrated using the tide charts of 4 major tidal constituents, M$_2$, S$_2$, $K_1$ and $O_1$. The numerical solutions show that there are significant changes of residual currents, especially induced by both tidal and wind-driven currents.

OpenMP application to implement CUDA for FDTD algorithm and performance measurement (CUDA로 구현한 FDTD알고리즘의 OpenMP기술 적용 및 성능 측정)

  • Jung, Bok-Jae;Oh, Seung-Take;Lee, Cheol-Hoon
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2013.01a
    • /
    • pp.3-6
    • /
    • 2013
  • 반도체 공정에서 소자의 제조 비용 감소를 위해 제조 공정 검증을 위한 시뮬레이션을 수행하게 된다. 이 시뮬레이션은 반도체 소자 내부의 물리량 계산을 통해 반도체 소자 내부의 불순물의 거동을 해석하게 된다. 이를 위해 사용되는 알고리즘으로 3차원적 형상을 표현하는 물리적 미분 미분방정식을 계산하게 되는데, 정확한 계산을 위해 유한 차분 시간 영역법(이하 FDTD)과 같은 수치해석 기법을 이용한다. 실제적으로 반도체 공정의 시뮬레이션에서 FDTD연산의 실행 시간은 90% 이상을 소요하게 된다. 이러한 연산에서 더욱 빠른 성능을 확보하기 위해 본 논문에서는 기존의 CUDA(Compute Unified Device Architecture)로 구현된 FDTD알고리즘을 OpenMP를 통한 다중 GPU제어를 이용하여 연산 수행시간을 감소하고, 그 결과물을 통하여 성능 향상도를 측정한다.

  • PDF

Analysis on Contaminant Transport according to the Embedded Depth of Vertical Barrier of Offshore Landfill (해상 폐기물매립지 연직차수벽체 근입심도에 따른 오염물질 이동특성 분석)

  • Park, Haeyong;Oh, Myounghak;Kwon, Osoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.8
    • /
    • pp.29-37
    • /
    • 2016
  • In order to prevent leakage of contaminants in offshore landfill, vertical barrier should be installed. Vertical barrier should be installed at designed depth of seabed to prevent the horizontal transport of contaminant in the subsurface. In this study, the seepage and contaminant transport in the subsurface according to embedded depth of vertical barrier were analyzed by using 2-D finite element analysis program SEEP/W and 3-D finite difference analysis program Visual Modflow. Numerical modelling results show that seepage flux and contaminant transport in seabed was greatly reduced when vertical barrier was installed at certain depth of low permeable layer. Therefore, the determination of minimum embedded depth for preventing contaminant leakage is helpful to design the economical vertical barrier.

Coupled Effect of Pile/Slope Systems (억지말뚝-사면의 상호작용 효과)

  • 정상섬;유광호;이선근
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.5
    • /
    • pp.163-173
    • /
    • 2003
  • In this paper, a numerical comparison of predictions by limit equilibrium analysis and 3D analysis is presented for slope/pile system. Special attention is given to the coupled analysis based on the explicit finite difference code, FLAC 3D. To this end, an internal routine (FISH) was developed to calculate a factor of safety for a file reinforced slope according to shear strength reduction technique. The case of coupled analyses was performed for stabilizing piles in slope in which the pile response and slope stability are considered simultaneously. In this study, by using these methods, the failure surfaces and factors of safety were compared and analyzed in several cases, such as toe, middle and top of the slope, respectively. Furthermore, the coupled method based on shear strength reduction technique was verified by the comparison with other analysis results.