• Title/Summary/Keyword: 3상 원심분리장치

Search Result 6, Processing Time 0.026 seconds

A Study on Three-Phase Separation Efficiency according to the Diffusion Plate of a High-Speed Centrifugal Separator (고속 원심분리장치의 확산판에 따른 상 분리효율에 관한 연구)

  • Lee, Choon-Man;Jeong, Ho-In
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.10
    • /
    • pp.99-103
    • /
    • 2019
  • Recently, as the high-precision machinery industry has developed rapidly, peripheral equipment has been developed to improve machining efficiency. Peripheral equipment for machining includes cooling units, housings, oil separators, and much more. Oil, such as cleaning and cutting fluids, is used for machining. When waste oil is reused, the contamination of the workpieces and reduction in machining accuracy are generated by the waste oil, including sludge. Therefore, the development of an oil separator is necessary for efficiently separating oil, water, and sludge. The purpose of this study is to analyze the oil separation efficiency and flow characteristics of a high-speed centrifugal separator according to the rotation velocity and diffusion plate. The oil separation efficiency and flow characteristics were analyzed using hydrodynamic theory and computational fluid dynamics (CFD). The results of this study will be used as basic data for the development of a high-speed centrifugal separator.

A Study on Steady-State Simulation and Experimental Test of Small Turbo Shaft Engine with Free Power Turbine (분리축 방식 소형 터보축 엔진의 정상상태 모사 및 실험연구)

  • 공창덕;기자영;고광웅
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.23-23
    • /
    • 1997
  • 다목적으로 활용할 수 있는 분리축 방식의 터보축 엔진 개발을 위한 정상상태 해석 프로그램의 개발과 함께 동일 형식의 가스터빈엔진 시험장치를 이용한 실험을 통해 프로그램의 해석결과와 비교, 그 타당성을 입증하였다. 실험에 이용된 시험장치는 1단 원심형 압축기, Can형 연소기, 1단 Radial형 압축기 터빈 및 동력터빈으로 구성되어 있으며 출력은 3상 교류발전기를 통해 획득된다. 해석에 사용된 주요 구성품의 성능곡선은 시험장치 제작자로부터 획득된 자료를 이용하였으며, 경우에 따라 시험장치를 이용한 실험을 통하여 보정하였다. 시험장치를 이용한 실험결과를 프로그램 해석결과와 비교한 결과, 시험장치의 운용제한에 의해 실제 자동영역이 제한되기는 했으나, 압력비, 출력 등 주요 변수들에서 10% 미만의 오차를 보였다.

  • PDF

A Steady-State Simulation and Experimental Study of Turboshaft Engine with Free Power Turbine (분리축방식 터보축 엔진의 정상상태 모사 및 실험연구)

  • 공창덕;기자영;고광웅
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.1 no.2
    • /
    • pp.84-90
    • /
    • 1997
  • The turboshaft engine with the free power turbine has been used for various purposes, for instance electric power generator, emergency power source, helicopter powerplant and so on. Steady-state simulation program was developed and experimental tests was carried out for comparing with computer simulation results. The test unit was composed of 1-stage centrifugal compressor, the can type combustor chamber, 1-stage radial type compressor turbine, and radial type free power turbine, and its output power is obtained from 3-phase AC generator. Main component characteristics which was used for the steady state simulation program, were obtained from the manufacturer of the test unit, and modified from experimental results of test unit. In comparison between computer simulation and experimental test results even though the test unit has the operational limit, deviation of component performance characteristics in simulation were within 6% range of experimental results.

  • PDF

3D-Printed Microhydrocyclone for Oil/Water Separation (유수분리를 위한 3D 프린팅 기술 기반의 마이크로하이드로사이클론)

  • Kim, Joowan;Kim, Won Jin;Park, Seung;Park, Cherry;Yoo, Jung Heum;Ji, Inseo;Kang, Jeon-Woong;Kim, Taeyung;Hong, Jiwoo
    • Korean Chemical Engineering Research
    • /
    • v.60 no.2
    • /
    • pp.289-294
    • /
    • 2022
  • Oil contained in domestic and industrial wastewater or marine spilled oil gives rise to severe environmental pollution issues such as water pollution and ecosystem destruction. The membrane filtration method as one of representative oil/water separation strategies has technological challenges such as membrane fouling and low separation rate. In this work, we devise a 3D-printed microhydrocyclone for oil/water separation by utilizing a digital lighting processing-based 3D printer. We demonstrate that the 3D-printed microhydrocyclone can effectively separate oil and water phases from oil-in-water emulsion.

Development and Validation of the Determination of Sorafenib in Human Plasma using Tandem Mass Spectrometry Coupled with Liquid Chromatography (고속액체크로마토그래피 텐덤질량분석기법을 이용한 사람 혈장 내 소라페닙 농도분석법의 개발 및 검정)

  • Park, Daejin;Lee, Sunggon;Kim, Woomi
    • Journal of Life Science
    • /
    • v.22 no.11
    • /
    • pp.1456-1462
    • /
    • 2012
  • Sorafenib is a multikinase inhibitor and an oral anticancer drug approved for the treatment of patients with advanced renal cell carcinoma and those with unresectable hepatocellular carcinoma. The purpose of this study was to develop an efficient method of the determination of sorafenib in human plasma using tandem mass spectrometry coupled with liquid chromatography (LC/MS/MS) and validate the method by the guidelines of the Korean Food and Drug Administration (KFDA). Plasma samples ($100{\mu}l$) were added with chlorantraniliprole as an internal standard and then mixed with the 0.1% formic acid-containing extraction solution composed of isopropyl alcohol and ethyl acetate (1:4, v/v). After centrifugation, the supernatant was concentrated at $45^{\circ}C$ under negative pressure and centrifugal force. The residue was reconstituted with a mobile phase and injected into the HPLC instrument using a reverse phase Waters XTerra$^{TM}$ C18 column (particle size $3.5{\mu}m$). Liquid chromatography was carried out within the run time of 5 min using a mobile phase composed of buffer (0.1% formic acid and 10 mM ammonium formate), methanol, and acetonitrile (1:6:3, v/v/v). The analytes were monitored by tandem mass spectrometry in the multiple reaction monitoring method programmed to detect sorafenib at 'm/z 465.2 ${\rightarrow}$ 252.5' and chlorantraniliprole at 'm/z 484.4 ${\rightarrow}$ 286.2' with positive electrospray ionization mode ($ES^+$). The result showed the proper linearity ($r^2$ > 0.99) over the range of 2,000-5,000 ng/ml with good accuracy (90.7-103.9%) and precision (less than 10%). The newly developed method using LC/MS/MS was validated by the guideline of KFDA and identified as more sensitive compared to the previous methods.

Processing of Intermediate Product(Krill Paste) Derived from Krill (크릴을 원료로 한 식품가공용 중간소재(크릴페이스트) 가공에 관한 연구)

  • LEE Eung-Ho;CHA Yong-Jun;OH Kwang-Soo;Koo Jae-Keun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.18 no.3
    • /
    • pp.195-205
    • /
    • 1985
  • As a part of investigation to use the Anatrctic krill, Euphausia superba, more effectively as a food source, processing conditions, utilizations and storage stability of krill paste (intermediate product of krill) were examined and also chemical compositions of krill paste were analyzed. Frozen raw krill was chopped, agitated with $25\%$ of water to the minced krill and then centrifuged to separate the liquid fraction from the residue. This liquid fraction was heated at $98^{\circ}C$ for 20 min. to coagulate the proteins of krill, and it was filtered to separate the protein fraction. Krill paste was prepared with grinding the protein fraction, adding $0.2\%$ of polyphosphate and $0.3\%$ of sodium erythorbate to the krill paste for enhancing of functional properties and quality stability. The krill paste was packed in a carton box, and then stored at $-30^{\circ}C$. Chemical compositions of krill paste were as follows : moisture $78\%$, crude protein $12.9\%$, crude lipid $5.9\%$, and the contents of hazardous elements of krill paste as Hg 0.001 ppm, Cd 1.15 ppm, Zn 9.1 ppm, Pb 0.63 ppm and Cu 11.38ppm were safe for food. The amino acid compositions of krill paste showed relatively high amount of taurine, glutamic acid, aspartic acid, leucine, lysine and arginine, which occupied $55\%$ of total amino acid and also taurine, lysine, glycine, arginine and proline were occupied $65\%$ of total free amino acid. Fatty acid compositions of krill paste consist of $32.4\%$ of saturated fatty acid, $29.6\%$ of monoenoic acid and $38.0\%$ of polyenoic acid, and major fatty acids of product were eicosapentaenoic acid ($17.8\%$), oleic acid ($16.9\%$), palmitic acid ($15.3\%$), myristic acid ($8.7\%$) and docosahexaenoic acid ($8.4\%$). In case of procssing of fish sausage as one of experiment for krill paste use, Alaska pollack fish meat paste could be substituted with the krill paste up to $30\%$ without any significant defect in taste and texture of fish sausage, and the color of fish sausage could be maintained by the color of krill paste. Judging from the results of chemical and microbial experiments during frozen storage, the quality of krill paste could be preserved in good condition for 100 days at $-39^{\circ}C$.

  • PDF