• 제목/요약/키워드: 2D scanner

검색결과 403건 처리시간 0.024초

생약복합제제(生藥複合製劑)의 약효(藥效) 연구(硏究) (제1보)(第1報) -가미삼황탕(加味三黃湯)이 중추신경계(中樞神經系)에 미치는 영향(影響)- (Studies oh the Efficacy of Combined Preparations of Crude Drug (I) -The Effect of 'Kamisamhwang-Tang' on Central Nervous System-)

  • 홍남두;김종우;송일병;김남재
    • 생약학회지
    • /
    • 제12권3호
    • /
    • pp.136-142
    • /
    • 1981
  • In order to investigate the efficacy of combined preparations of crude drug, first, 'Kamisamhwang-Tang' were examined for pharmacological effect. Crude drug preparations were extracted successively with $H_2O$ and MeOH, and the extracts were developed on silicagel G plate were examined using the Dual-Wavelength TLC Scanner CS-910(Schimadzu) in ultra violet region. To estimate the clinical usefulness of 'Kamisamhwang-Tang' in heart disease (Symbyung syndrome), the above extracts were made an experiment on effects of the anticonvulsion, antipyretic, analgesic and sedative in mice, rats, and rabbits.

  • PDF

두건류 제작을 위한 남성의 두부 형태 분석 (Analysis of Head shape of college students for the Headgears)

  • 이진희
    • 한국의류학회지
    • /
    • 제28권1호
    • /
    • pp.182-188
    • /
    • 2004
  • The purpose of the study was to provide scientific and accurate data of head shape for men. This study was carried out on 214 men and Factor analysis, Cluster analysis, Duncan analysis with 15 variables were performed using the data. A 3D scanner was used for visual results of head shape. The results were as follows. First, through factor analysis of the variables, three factors were extracted upon factor scores. The first factor described thickness part, and second factor described width parts and the third factor described vertical length parts. Four clusters represented characteristics of men's head types. Type 1 had a larger head thickness, type 2 had a smaller thickness and smaller width. type 4 had a generally larger head. In the distribution of the four clusters, type 1 was distributed 34%. Type 4 was distributed 23%. According to the results, type 1 of the more thick and narrow head was dominant among head types of men.

유니버셜 관절을 이용한 2차원 레이저 영상 구현 (An Implementation of Laser image drawing with the uiversal joint)

  • 김종걸;김태강;이건영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2705-2707
    • /
    • 2000
  • The branch of the laser imaging has implemented 3D graphics, color graphics and video images after it drew a simple image by development the salvo's X-Y scanner in 1960 year. Now it is used as the multimedia show of an event and an advertisement. The latest issue of laserist is the ability to generate laser images with the same ease and speed associated with traditional computer graphics. All laser projector used in the interior of a countris was imported from other country. The most important component of the laser projector is the speed and the accuracy of a actuator and the software which actuates the controller on computer. In this paper we developed the controller with a universal joint and the PC based user interface software in order to implement the laser image of two dimension, and will prepare the base of beginning the home laser projector

  • PDF

초고장력 강판을 적용한 Cowl Cross Member의 레이저 용접 적용에 관한 연구 (A Study on Laser Welding Application of the Cowl Cross Member for Ultra-High Strength Steel)

  • 박동환;윤재정;김근영
    • 한국생산제조학회지
    • /
    • 제23권5호
    • /
    • pp.525-531
    • /
    • 2014
  • A cowl cross is a part of the car's instrument panel used to maintain the rigidity of the vehicle body side. The application of laser welding has the benefits of speed and thermal deformation compared to arc welding. An ultra-high strength steel sheet is used to reduce the weight of the vehicle body parts. Generally, formability of such a steel sheet is poor because its elongation is very low. For this reason, a method for cold forming of an ultra-high strength steel sheet is required. This paper describes how to improve the formability and weldability of the ultra-high strength steel sheet. Mechanical tests of this material were also performed to evaluate the welding properties of $CO_2$ (GMAW) and those of laser welding.

3차원 스캐너를 이용한 혼합치열기 반대교합아동의 구개형태에 관한 연구 (CHARACTERISTICS OF THE PALATAL MORPHOLOGY OF THE CHILDREN WITH CROSSBITE IN MIXED DENTITION BY 3-DIMENSIONAL LASER SCANNER)

  • 김동원;박호원
    • 대한소아치과학회지
    • /
    • 제30권1호
    • /
    • pp.132-142
    • /
    • 2003
  • 본 연구는 Hellman 치령 IIIA기에 해당되는 전치부 반대교합아동의 구개형태에 대한 특징을 3차원 레이저 스캐너를 이용하여 조사한 것이다. 반대교합아동과 정상교합아동 각각 20개의 상악 석고모형을 채득하였다. 각 모형은 3차원 레이저 스캐너(Intertec, Korea)로 스캔한 후 rapidform 2000 프로그램 (INUS, Korea)으로 3차원 이미지를 얻었으며, Rhino 3D 프로그램(rhinoceros, USA)으로 수치화 하였다. 측정부위는 양측 유견치 및 제1대구치를 연결한 횡단면상의 구개형태 곡선 그리고 절치유두의 최정점에서 양측 제1대구치 원심면까지의 구개봉합선을 따르는 구개형태곡선들이었다. 개체들간의 크기 차이 보정을 위해 측정부위를 각각 25mm, 35mm, 35mm로 조정하여 표준화 하였다. 표준화된 구개형태곡선들에서 직선거리 각 1mm에 해당되는 점들에서의 곡선 깊이를 소수점 3자리까지 수치화 하여 평균 구개형태곡선을 얻고, 그 좌표 차이를 95% 신뢰구간의 t-test를 통해 비교, 분석하여 다음과 같은 결론을 얻었다. 1. 양측 유견치를 연결한 횡단면상의 평균구개형태곡선은 반대교합아동이 좀더 평탄한 V자형의 곡선형태를 보였으나, 반대교합아동과 정상교합아동 사이에 통계적으로 유의할 만한 차이는 보이지 않았다(P>0.05). 2. 양측 제1대구치를 연결한 횡단면상의 평균구개형태곡선은 반대교합아동이 정상교합아동보다 더 구개의 깊이가 깊었으며, 상악 우측 제1대구치 치은 최하방점에서부터 8mm와 21mm위치 사이의 구간에서 통계적으로 유의할 만한 차이가 있었다(P<0.05). 3. 반대교합아동과 정상교합아동간의 구개봉합선의 평균구개형태곡선에서는 전구간에 걸쳐 반대교합아동이 더 깊은 곡선 형태를 보였고, 통계적으로도 유의할 만한 차이를 보였다(P<0.01).

  • PDF

기능성 소화불량에 대한 육군자탕 엑스과립의 사상체질별 치료효과: 위약 대조, 이중 맹검, 무작위 시험 (Effects of a Herbal Medicine, Yukgunja-Tang Extract Granule, on Functional Dyspepsia Patients by Sasang Constitution: Placebo-Controlled, Double-Blind, Randomized Trial)

  • 전수형;김종원
    • 사상체질의학회지
    • /
    • 제30권2호
    • /
    • pp.42-54
    • /
    • 2018
  • Objectives This study was aimed to compare effects of Yukgunja-tang (YGJT) extract granule on functional dyspepsia (FD) by sasang constitution. Methods A placebo-controlled, double-blind, randomized, two-center trial was performed. We obtained 3D face images of FD patients participating in this study using face-only scanner and classified them into two types as narrow face and wide face by 3D facial shape diagnosis system (3-FSDS). 96 subjects (48 subjects per type) were enrolled and were randomly allocated into treatment or control groups in a 2:1 ratio. YGJT extract granule or placebo were administered to each group during the 8 week treatment period. One of sasang constitutional specialist diagnosed their constitutions by referring to questionnaires and 3D face images. The primary outcome was total dyspepsia symptom scale (TDS scale), the secondary outcomes were single dyspepsia symptom scale (SDS scale), visual analog scale (VAS) and so on. This trial was registered with clinical research information service identifier: KCT0001920, 15 May, 2016. Results In the Taeeumin treatment group, the TDS scale was significantly decreased after 8 weeks compared to the control group (t=2.331, p=0.025) and the SDS scale also significantly decreased. (t=2.042, p=0.048). The specific effects of the YGJT extract granule without the placebo effect on the Taeeumin with functional dyspepsia were 30.61% in TDS scale and 28.33% in SDS scale. Conclusions The effects of Yukgunja-tang extract granule on functional dyspepsia was different according to Sasang constitution. So the constitution should be considered in randomized controlled trials using herbal extract granules.

사람 뇌의 3차원 영상과 가상해부 풀그림 만들기 (Manufacture of 3-Dimensional Image and Virtual Dissection Program of the Human Brain)

  • 정민석;이제만;박승규;김민구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.57-59
    • /
    • 1998
  • For medical students and doctors, knowledge of the three-dimensional (3D) structure of brain is very important in diagnosis and treatment of brain diseases. Two-dimensional (2D) tools (ex: anatomy book) or traditional 3D tools (ex: plastic model) are not sufficient to understand the complex structures of the brain. However, it is not always guaranteed to dissect the brain of cadaver when it is necessary. To overcome this problem, the virtual dissection programs of the brain have been developed. However, most programs include only 2D images that do not permit free dissection and free rotation. Many programs are made of radiographs that are not as realistic as sectioned cadaver because radiographs do not reveal true color and have limited resolution. It is also necessary to make the virtual dissection programs of each race and ethnic group. We attempted to make a virtual dissection program using a 3D image of the brain from a Korean cadaver. The purpose of this study is to present an educational tool for those interested in the anatomy of the brain. The procedures to make this program were as follows. A brain extracted from a 58-years old male Korean cadaver was embedded with gelatin solution, and serially sectioned into 1.4 mm-thickness using a meat slicer. 130 sectioned specimens were inputted to the computer using a scanner ($420\times456$ resolution, true color), and the 2D images were aligned on the alignment program composed using IDL language. Outlines of the brain components (cerebrum, cerebellum, brain stem, lentiform nucleus, caudate nucleus, thalamus, optic nerve, fornix, cerebral artery, and ventricle) were manually drawn from the 2D images on the CorelDRAW program. Multimedia data, including text and voice comments, were inputted to help the user to learn about the brain components. 3D images of the brain were reconstructed through the volume-based rendering of the 2D images. Using the 3D image of the brain as the main feature, virtual dissection program was composed using IDL language. Various dissection functions, such as dissecting 3D image of the brain at free angle to show its plane, presenting multimedia data of brain components, and rotating 3D image of the whole brain or selected brain components at free angle were established. This virtual dissection program is expected to become more advanced, and to be used widely through Internet or CD-title as an educational tool for medical students and doctors.

  • PDF

Feasibility of Fabricating Variable Density Phantoms Using 3D Printing for Quality Assurance (QA) in Radiotherapy

  • Oh, Se An;Kim, Min Jeong;Kang, Ji Su;Hwang, Hyeon Seok;Kim, Young Jin;Kim, Seong Hoon;Park, Jae Won;Yea, Ji Woon;Kim, Sung Kyu
    • 한국의학물리학회지:의학물리
    • /
    • 제28권3호
    • /
    • pp.106-110
    • /
    • 2017
  • The variable density phantom fabricated with varying the infill values of 3D printer to provide more accurate dose verification of radiation treatments. A total of 20 samples of rectangular shape were fabricated by using the $Finebot^{TM}$ (AnyWorks; Korea) Z420 model ($width{\times}length{\times}height=50mm{\times}50mm{\times}10mm$) varying the infill value from 5% to 100%. The samples were scanned with 1-mm thickness using a Philips Big Bore Brilliance CT Scanner (Philips Medical, Eindhoven, Netherlands). The average Hounsfield Unit (HU) measured by the region of interest (ROI) on the transversal CT images. The average HU and the infill values of the 3D printer measured through the 2D area profile measurement method exhibited a strong linear relationship (adjusted R-square=0.99563) in which the average HU changed from -926.8 to 36.7, while the infill values varied from 5% to 100%. This study showed the feasibility fabricating variable density phantoms using the 3D printer with FDM (Fused Deposition Modeling)-type and PLA (Poly Lactic Acid) materials.

Pose and Expression Invariant Alignment based Multi-View 3D Face Recognition

  • Ratyal, Naeem;Taj, Imtiaz;Bajwa, Usama;Sajid, Muhammad
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제12권10호
    • /
    • pp.4903-4929
    • /
    • 2018
  • In this study, a fully automatic pose and expression invariant 3D face alignment algorithm is proposed to handle frontal and profile face images which is based on a two pass course to fine alignment strategy. The first pass of the algorithm coarsely aligns the face images to an intrinsic coordinate system (ICS) through a single 3D rotation and the second pass aligns them at fine level using a minimum nose tip-scanner distance (MNSD) approach. For facial recognition, multi-view faces are synthesized to exploit real 3D information and test the efficacy of the proposed system. Due to optimal separating hyper plane (OSH), Support Vector Machine (SVM) is employed in multi-view face verification (FV) task. In addition, a multi stage unified classifier based face identification (FI) algorithm is employed which combines results from seven base classifiers, two parallel face recognition algorithms and an exponential rank combiner, all in a hierarchical manner. The performance figures of the proposed methodology are corroborated by extensive experiments performed on four benchmark datasets: GavabDB, Bosphorus, UMB-DB and FRGC v2.0. Results show mark improvement in alignment accuracy and recognition rates. Moreover, a computational complexity analysis has been carried out for the proposed algorithm which reveals its superiority in terms of computational efficiency as well.

미국 여성의 3차원 바디 스캔 이미지 분석을 통한 상반신 측면체형 분류 (Classification of Side Somatotype of Upper Lateral Torso Analyzing 3D Body Scan Image of American Females)

  • 나현신
    • 복식
    • /
    • 제57권4호
    • /
    • pp.9-17
    • /
    • 2007
  • Somatotype is human body shape and physique type which can be classified not only by the size, but also by the shape or posture of the body. Postural variations in the alignment of the back, shoulder, and neck can have an adverse effect on the fit of garments designed to hang from the shoulders. There have been some previous studies about the lateral upper torso by analyzing photographic measurements. In this study, 3D body scan images were used to classify the side somatotype of upper lateral method even though they are major data in the classification of upper torso. This study focused on following objective.; 1) To apply new and developing technology into the apparel industry analyzing 3D body scan images. 2) To classify upper laterla torso using the data through the new improver technology, 3D body scanner. 3) To propose basic materials for well fitted garments for each type of figure. The test subjects for this study were two hundreds nine female aged 19 years and up who were recruited in Cornell university body scan research team. Seventeen Variables(12 angles, 5 lengths) out of 3D body scan data were measured based on these landmarks and applied to analyze. The result of factor analysis indicated that 6 factors were extracted through factor analysis and orthogonal rotation by the method of Varimax and those factors comprise 62.5% of total variance. And the somatotype of upper body is classified into 3 types of figures according to cluster analysis; Bent forward posture, Straight posture, Swayback posture. Future study could be addressed about the somatotype of body by the age group based on the large database with wide variety of age.