• 제목/요약/키워드: 2D scanner

검색결과 403건 처리시간 0.031초

Validation of a low-cost portable 3-dimensional face scanner

  • Liu, Catherine;Artopoulos, Andreas
    • Imaging Science in Dentistry
    • /
    • 제49권1호
    • /
    • pp.35-43
    • /
    • 2019
  • Purpose: The goal of this study was to assess the accuracy and reliability of a low-cost portable scanner (Scanify) for imaging facial casts compared to a previously validated portable digital stereophotogrammetry device (Vectra H1). This in vitro study was performed using 2 facial casts obtained by recording impressions of the authors, at King's College London Academic Centre of Reconstructive Science. Materials and Methods: The casts were marked with anthropometric landmarks, then digitised using Scanify and Vectra H1. Computed tomography (CT) scans of the same casts were performed to verify the validation of Vectra H1. The 3-dimensional (3D) images acquired with each device were compared using linear measurements and 3D surface analysis software. Results: Overall, 91% of the linear Scanify measurements were within 1 mm of the corresponding reference values. The mean overall surface difference between the Scanify and Vectra images was <0.3mm. Significant differences were detected in depth measurements. Merging multiple Scanify images produced significantly greater registration error. Conclusion: Scanify is a very low-cost device that could have clinical applications for facial imaging if imaging errors could be corrected by a future software update or hardware revision.

소아 얼굴 연조직의 3차원 입체영상의 정확성 및 재현성 평가 (Accuracy and Precision of Three-dimensional Imaging System of Children's Facial Soft Tissue)

  • 최경화;김미선;이고은;남옥형;이효설;최성철;김광철
    • 대한소아치과학회지
    • /
    • 제47권1호
    • /
    • pp.17-24
    • /
    • 2020
  • 이 연구의 목적은 소아 얼굴 연조직의 선형 길이를 비교하여 삼차원 입체영상의 정확성과 재현성을 평가하는 것이다. 연구는 7 - 12세 아동 15명을 대상으로 하였다. 환자의 안모에 23개의 계측 점을 표시하고, 전자 캘리퍼를 이용하여 16 개의 선형길이를 직접 2번 계측하였다. 3차원(3D) 스캐너를 이용하여 2개의3D 얼굴 영상을 만들었으며, 직접계측과 동일한 16개의 선형 길이를 계측하였다. 연구결과 정확성 평가에서 전체 평균 차이 값은 0.9 mm였다. 3D 영상의 재현성은 직접계측의 재현성과 거의 유사한 정도로 나타났다. 이에 따라 이 3D 영상장비는 소아에서 임상적으로 충분한 정확성과 재현성을 가지고 있었다. 3D 영상 시스템은 정확한 이미지를 위하여 대상의 협조가 필요하다. 소아의 정확한 3D영상을 얻기 위한 구체적인 지시사항을 바탕으로 촬영을 한다면, 이 3D 영상 장비는 향후 소아의 성장과 발달을 조사하고, 소아교정치료에서 결과를 평가하는데 유용하게 사용될 수 있을 것이다.

XY 스캐너의 아베 오차 최소화를 위한 최적 설계 및 나노 정밀도의 원자 현미경 피치 측정 불확도 평가 (Optimal design of a flexure hinge-based XY AFM scanner for minimizing Abbe errors and the evaluation of pitch measuring uncertainty of a nano-accuracy AFM system)

  • 김동민;이동연;권대갑
    • 한국정밀공학회지
    • /
    • 제23권6호
    • /
    • pp.96-103
    • /
    • 2006
  • To establish of standard technique of nano-length measurement in 2D plane, new AFM system has been designed. In the long range (about several tens of ${\mu}m$), measurement uncertainty is dominantly affected by the Abbe error of XY scanning stage. No linear stage is perfectly straight; in other words, every scanning stage is subject to tilting, pitch and yaw motion. In this paper, an AFM system with minimum offset of XY sensing is designed. And XY scanning stage is designed to minimize rotation angle because Abbe errors occur through the multiply of offset and rotation angle. To minimize the rotation angle optimal design has performed by maximizing the stiffness ratio of motion direction to the parasitic motion direction of each stage. This paper describes the design scheme of full AFM system, especially about XY stage. Full range of fabricated XY scanner is $100{\mu}m\times100{\mu}m$. And tilting, pitch and yaw motion are measured by autocollimator to evaluate the performance of XY stage. As a result, XY scanner can have good performance. Using this AFM system, 3um pitch specimen was measured. The uncertainty of total system has been evaluated. X and Y direction performance is different. X-direction measuring performance is better. So to evaluate only ID pitch length, X-direction scanning is preferable. Its expanded uncertainty(k=2) is $\sqrt{(3.96)^2+(4.10\times10^{-5}{\times}p)^2}$ measured length in nm.

2D 라이다를 이용한 실내 구조 스캐너 개발 (Development of Indoor Structure Scanner using 2D LIDAR)

  • 김기준;박재형;문현민;이하은;이승대
    • 한국전자통신학회논문지
    • /
    • 제18권6호
    • /
    • pp.1189-1196
    • /
    • 2023
  • 실내 공간과 관련된 정보는 도시화의 가속과 기술의 발달로 인하여 그 중요성이 증가하고 있으며, 건물 내부의 다목적 활용을 위하여 다양한 스캐닝 기술이 개발되고 있다. 본 논문에서는 스캐닝에 2D 라이다를 이용하여 지면과 수직인 방향으로 라이다를 회전 및 이동시키며 2차원 데이터의 집합을 얻은 후 이를 취합하여 3차원의 실내 공간 정보를 얻는 시스템을 제안하였다. 최종적으로 오차 보정 등의 알고리즘을 적용하여 실내 구조를 입체적으로 시각화하여 출력하였다.

삼차원 스캐너와 가변 적층 쾌속조형공정을 이용한 대형 입체 형상의 쾌속 제작 : 러쉬모어산 기념물 제작 사례 (Rapid Fabrication of Large-Sized Solid Shape using 3D Scanner and Variable Lamination Manufacturing : Case Study of Mount Rushmore Memorial)

  • 이상호;김효찬;송민섭;박승교;양동열
    • 대한기계학회논문집A
    • /
    • 제28권12호
    • /
    • pp.1958-1967
    • /
    • 2004
  • This paper describes the method to rapidly fabricate the large-sized physical model with the envelope model size of more than 600 mm${\times}$ 600 mm${\times}$ 600 mm using two type semi-automatic VLM-ST processes in connection with the reverse engineering technology. The fabrication procedure of the large-sized solid shape is as follows: (1) Generation of STL data from 3D scan data using 3D scanner, (2) generation of shell-type STL data by Boolean operation, (3) division of shell-type STL data into several pieces by solid splitting, (4) generation of USL data for each piece with VLM-Slicer, (5) fabrication of each piece by cutting and stacking according to USL data using VLM-ST apparatus, (6) completion of a shell-type prototype by zigzag stacking and assembly for each piece, (7) completion of a 3D solid shape by foam backing, (8) surface finish of a completed 3D solid shape by coating and sanding. In order to examine the applicability of the proposed method, the miniature of the Mount Rushmore Memorial has been fabricated. The envelope model size of the miniature of the Mount Rushmore Memorial is 1,453 mm${\times}$ 760 mm${\times}$ 853 mm in size. From the result of the fabricated miniature of the Mount Rushmore Memorial, it has been shown that the method to fabricate the large object using two type semi-automatic VLM-ST processes in connection with the reverse engineering technology are very fast and efficient.

3차원 스캔 데이터에 의한 노년 남성의 발 측면유형 분류 (Classification of Elderly Men's Foot Side Type from 3D Scan Data)

  • 김남순;도월희
    • 한국의류학회지
    • /
    • 제38권4호
    • /
    • pp.427-439
    • /
    • 2014
  • This study identifies the foot side shapes of elderly men by classifying foot types according to 3D foot shapes and analyzing individual characteristics. The subjects were 284 elderly men over 60 years of age who lived in Gwangju and did not have foot related diseases. They were measured with a scanner (Nexcan$^{(R)}$ of K&I Technology) to obtain three dimensional feet shapes. Anthropometric measuring items consisted of 28 items estimated on the right foot of each subject. 3D scan data were analyzed by various statistical methods such as factor analysis, ANOVA and cluster analysis using the statistical program SPSS 19.0. A total of 7 factors were extracted through a factor analysis and these factors represent 77.56% of total variance. The 8 factors were: inside height and side gradient, ankle thickness, size from foot center to ankle, lateral malleolus height, forefoot height, instep and heel height and gradient. A total of 3 clusters (as foot type) were categorized using 7 factor scores by cluster analysis. Type 1 was classified as high forefoot and low midfoot compared to the length. Type 2 was classified as low forefoot and high midfoot, and type 3 was classified as low forefoot and low midfoot.

A study on the core technologies for industrial type digital 3D SFF system

  • Kim, Dong-Soo;An, Young-Jin;Kim, Sung-Jon;Choi, Byung-Oh;Lim, Hyun-Eui
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.2170-2174
    • /
    • 2005
  • Selective Laser Sintering (SLS) is a useful rapid prototyping technique for the manufacture of three dimensional (3D) solid objects directly from a scanning data. A new approach called a Selective Multi-Laser Sintering (SMLS) system has been developed at Korea Institute Machinery & Materials (KIMM) as an industrial type SFFS. This SMLS machine is built with a frame, heaters, nitrogen supply part, laser system. This system uses the dual laser and 3D scanner made in $Solutionix^{TM}$ to improve the precision and speed for large objects. The three-dimensional solid objects are made of polyamide powder. The investigation on each part of SMLS system is performed to determine the proper theirs design and the effect of experimental parameters on making the 3D objects. The temperature of the system has a great influence on sintering the polymer. Because the stability of the powder temperature prevents the deformation of each layer, the controls of the temperature in both the system and the powders are very important during the process. Therefore, we simulated the temperature distribution of build room using the temperature analysis with ANSYS program. Selected radiant heater is used to raise temperature of powder to melting point temperature. The laser parameters such as scan spacing, scan speed, laser power and laser delay time affect the production the 3D objects too. The combination of the slow scan speed and the high laser power shows the good results without the layer curling. The work is under way to evaluate the effect of experimental parameters on process and to produce the various objects. We are going to experiment continuously to improve the size accuracy and surface roughness.

  • PDF

CT data 기반 3D 프린팅으로 제작된 Small Finger, 실제 Small Finger 그리고 석고 Small Finger 형상 비교 연구 (Comparative study on the Shape between a Customized Finger Made by 3D Printing Technology, Real Small Finger, a plaster Small Finger, Based on CT Data)

  • 최현우;안도현;이도병;이종민;서안나
    • 한국방사선학회논문지
    • /
    • 제13권2호
    • /
    • pp.153-158
    • /
    • 2019
  • 이 연구의 목적은 3D 프린팅 기술로 만든 맞춤형 소지, 본인의 실제 소지 및 보조기 업체 석고 양성 소지를 이용하여 세 종류의 소지의 형상 차이를 CT와 3D 스캐너로 횡단면 넓이와 부피를 분산 분석하였다. PASC Progrm으로 실제 거리를 측정하는 (Caliper Toll) 기능을 이용하여 15.69 mm지점(Distal Interphalangel Joints(DIP))의 넓이를 각각 30회씩 측정하였고, 부피(Volume)에서 Meshmixer Program의 Configure Units을 이용하였다. 세 종류의 소지 횡단면 넓이에서는 유의한 차이를 볼 수가 없었고, 부피(Volume)에서 0.2 mm의 차이가 있었지만, 유의 수준보다 크게 나타났다. 따라서 본 연구의 결과는 의료분야에서 3D 프린팅 기술을 활용한 맞춤형 보조기 제작에 활성화될 것으로 보여준다.

2D 스캐너를 이용한 선재 위치 분류장치의 설계와 해석 (Design and Analysis of Wire Classification Device using the 2D Scanner)

  • 류환규;류정규;김정호
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2013년도 추계학술발표대회
    • /
    • pp.449-452
    • /
    • 2013
  • 최근 산업, 무역 및 유통 기업들은 수 많은 물류 자원에 IT 기술이 도입되어 운용되고 있다. 이러한 기업들은 물류 비용을 절감하기 위해 자동차 생산 분류와 물류 수송 부분으로 이어진다. 물류 분야 중 자동차 생산 분류에 선재 관리를 통해 기업과 기업으로 서로 운송되어 분류되어 있으며, 차량 선재 분배를 위해 POS에서 나온 데이터를 바코드를 사용하게 된다. 그러나, 이러한 선재의 문제점은 작업자의 분류지를 일일이 보면서 확인을 통해 작업을 하고 있으며, 작업자의 누락 혼합 발생된 물류 납품시 타사 기업으로 선재의 혼합, 누락 등으로 2차적 피해가 발생하게 된다. 따라서, 본 연구에서는 차량 선재의 분류에 대한 2D 스캐너 기반의 프로세서와 시스템을 포함하고 선재 물류 분류 장치를 통해 특성을 설계하고 현장을 개선하고자 한다.

계수공정영상의 비선형 대조도 증강효과에 관한 연구 (NONLINEAR CONTRAST ENHANCEMENT ON SUBTRACTION IMAGES)

  • 이건일;진연화
    • 치과방사선
    • /
    • 제27권2호
    • /
    • pp.83-90
    • /
    • 1997
  • This study was performed to demonstrate the effect of linear or nonlinear contrast enhancement on subtraction images. Three different textures were radiograped on dental film. The first radiograph was taken without the presence of an object. the second, which showed trabucular bone, was taken of the molar area of a human. the third radiograph was taken of the coronal part of molars. Each film was digitized into a 1312 x 1024 pixel x 8 bit depth matrix by means of a Nikon 35 mm film scanner(LS-3510AF, Japan) with fixed gain and internal dark current correction to maintain constant illumination. The scanner was interfaced to a Macintosh Le ill computer(Apple Computer, Charlotte, N.C) This resulted in three pairs of images, including different textures-plain, bone and enamel. Digital regular, linearly and nonlinearly enhanced subtraction was performed. Computer software was ,used to simulate lesions in the shape of a 2D-Gaussian curve on each of a pair of images. The each subtraction images were presented in a random sequence to two groups of 10 observers(students and dentists). ROC analysis was used to compare observer performance. The following results were obtained ; 1. All of LCE subtraction, equalized subtraction and regular subtraction images of plain texture were diagnosed the best by far. 2. The data revealed a siginificant LCE effect in both the student group and the expert group. 3. Clinical expertise was a helphul factor for the observers in this study.

  • PDF