• 제목/요약/키워드: 2D scanner

검색결과 403건 처리시간 0.026초

Reverse Engineering 기법의 레이저 스캐너를 이용한 의치상의 정확도에 관한 연구 (DIMENSIONAL ACCURACY OF DENTURE BASE USING LASER SCANNER OF REVERSE ENGINEERING TECHNIC)

  • 이시혁;장익태;임순호
    • 대한치과보철학회지
    • /
    • 제37권2호
    • /
    • pp.167-184
    • /
    • 1999
  • The purpose of this study was to evaluate and compare the at of denture bases processed by injection pressing technic using laser scanner of reverse engineering technic. The auther duplicated 20 maxillary edentulous models and 20 mandibular edentulous models, which were scanned on HYSCAN 45C 3D BCANNER(Hymarc Co., Canada). The scanned data were stored in the personal computer using SURFACER (Imageware Co. U.S.A.) software program. After 40 dentures were cured by PERform Inkovac system, SR-Ivocap system, Palajet system, and Sulfon system, they were stored in water at room temperature fir 24 hours. The dentures were scanned on HYSCAN 45C 3D SCANNER(Hymarc Co., Canada). The scanned data were stored in the personal computer using SURFACER (Imageware Co., U.S.A.) software program. By overlapping two images using the same program, the fit between two surfaces was scaled by positive and negative errors. The obtained results were as follows 1. In the upper denture, most of the positive errors occurred on the lingual side of anterior alveolar ridge and the negative errors were on the flange of denture bases. 2. In the lower denture, most of the positive errors occurred on the inner side of lingual flange and the negative errors were on the border of anterior labial flange areas, 3. There were no statistical differences among the positive errors of the four types of injection denture curing methods and also no statistical differences between negative errors except only in negative maximum errors. 4. In PERform system and SR-Ivocap system, they have the tendency of inaccurate at of lower denture bases comparing to that of upper denture bases. 5. The negative error scales were greater than the positive error scales in all types of injection denture curing methods.

  • PDF

Evaluation of different approaches for using a laser scanner in digitization of dental impressions

  • Lee, Wan-Sun;Kim, Woong-Chul;Kim, Hae-Young;Kim, Wook-Tae;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권1호
    • /
    • pp.22-29
    • /
    • 2014
  • PURPOSE. This study aimed to investigate the potential clinical application of digitized silicone rubber impressions by comparing the accuracy of zirconia 3-unit fixed partial dentures (FPDs) fabricated from 2 types of data (working model and impression) obtained from a laser scanner. MATERIALS AND METHODS. Ten working models and impressions were prepared with epoxy resin and vinyl polysiloxane, respectively. Based on the data obtained from the laser scanner (D-700; 3Shape A/S, Copenhagen, Denmark), a total of 20 zirconia frameworks were prepared using a dental CAD/CAM system (DentalDesigner; 3shape A/S, Copenhagen, Denmark / Ener-mill, Dentaim, Seoul, Korea). The silicone replicas were sectioned into four pieces to evaluate the framework fit. The replicas were imaged using a digital microscope, and the fit of the reference points (P1, P2, P3, P4, P5, P6, and P7) were measured using the program in the device. Measured discrepancies were divided into 5 categories of gaps (MG, CG, AWG, AOTG, OG). Data were analyzed with Student's t-test ($\alpha$=0.05), repeated measures ANOVA and two-way ANOVA (${\alpha}=0.05$). RESULTS. The mean gap of the zirconia framework prepared from the working models presented a narrower discrepancy than the frameworks fabricated from the impression bodies. The mean of the total gap in premolars (P=.003) and molars (P=.002) exhibited a statistical difference between two groups. CONCLUSION. The mean gap dimensions of each category showed statistically significant difference. Nonetheless, the digitized impression bodies obtained with a laser scanner were applicable to clinical settings, considering the clinically acceptable marginal fit ($120{\mu}m$).

17GHz 대역의 저출력 Electronic Scanner 개발 (Development of Low-Power Electronic Scanner for 17GHz Band)

  • 정선재;전성호;이영섭;이광근;임재홍
    • 한국정보통신학회논문지
    • /
    • 제23권4호
    • /
    • pp.445-452
    • /
    • 2019
  • 오늘날 해양 업계에서 활용되는 대부분의 탐지 시스템은 고출력의 X-Band 대역을 활용한 장비들이 대다수이다. 이러한 X-Band 대역의 주파수를 활용하는 대부분의 탐지 시스템들은 광범위한 탐지 성능 이득을 기대할 수 있지만, 장비의 특성상 크고 무거우며 정밀한 탐지를 요하는 분야에서는 적합하지 않다는 한계점을 지닌다. 본 논문에서는 Ku-Band 대역 중 17GHz 주파수 대역에서 2W 미만의 저출력으로 주변의 물표뿐만 아니라 바다의 파랑까지 탐지가 가능한 Electronic Scanner를 설계 및 제작하고, 시험을 진행하였다. 저전력에서도 충분한 탐지성능을 확보하기 위하여 고성능의 패치 어레이 안테나 및 도플러 효과를 활용하여 충분한 탐지 성능을 확보하였으며, 이에 대한 시험 결과 충분한 가능성을 확인할 수 있었다.

Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study

  • Kim, Sung-Jun;Son, KeunBaDa;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권5호
    • /
    • pp.388-394
    • /
    • 2018
  • PURPOSE. To measure axial displacement of different implant-abutment connection types and materials during screw tightening at the recommended torque by using a contact scanner for two-dimensional (2D) and three-dimensional (3D) analyses. MATERIALS AND METHODS. Twenty models of missing mandibular left second premolars were 3D-printed and implant fixtures were placed at the same position by using a surgical guide. External and internal fixtures were used. Three implant-abutment internal connection (INT) types and one implant-abutment external connection (EXT) type were prepared. Two of the INT types used titanium abutment and zirconia abutment; the other INT type was a customized abutment, fabricated by using a computer-controlled milling machine. The EXT type used titanium abutment. Screws were tightened at $10N{\cdot}cm$, simulating hand tightening, and then at the manufacturers' recommended torque ($30N{\cdot}cm$) 10 min later. Abutments and adjacent teeth were subsequently scanned with a contact scanner for 2D and 3D analyses using a 3D inspection software. RESULTS. Significant differences were observed in axial displacement according to the type of implant-abutment connection (P<.001). Vertical displacement of abutments was greater than overall displacement, and significant differences in vertical and overall displacement were observed among the four connection types (P<.05). CONCLUSION. Displacement according to connection type and material should be considered in choosing an implant abutment. When adjusting a prosthesis, tightening the screw at the manufacturers' recommended torque is advisable, rather than the level of hand tightening.

3차원 원격 스캐너를 이용한 알루미늄 5000 계열의 레이저 용접에서 공정 변수에 따른 용접 특성 분석 (Analysis of Weld Characteristics for Aluminum 5XXX Series Laser Welding Using 3-Dimension Remote Scanner)

  • 김동윤;박영환
    • 한국레이저가공학회지
    • /
    • 제14권2호
    • /
    • pp.1-7
    • /
    • 2011
  • The latest trends of vehicle technology development are fuel efficiency improvement, body designs declining air resistance and lightweight of materials. Especially, as lightened weight of materials makes engine efficient so that vehicles keep the best performance, it is the best way to protect the environment and reduce fuel consumption. In this study, we conducted laser welding by using 3-dimension remote scanner that is 5J32 aluminium alloy. Furthermore, conduction experiment that was 3 times repeated for changing factors such as observing angle, laser power and welding speed. we observed exterior and cross section of weled part and tensile strength. When increasing laser power and decreasing laser speed, tensile strength increased. In order to evaluate factors that affect tensile strength qualitatively we conducted ANOVA. We assumed that the factors are observing angle, laser power and welding speed. Then we found that laser power and laser speed affect tensile strength. We conducted evaluation of weldability of aluminium alloy by above ways.

  • PDF

수종의 치과용 스캐너로 채득된 3차원 치아 모형의 반복측정 안정성 평가 연구 (A Study on the Evaluation of Repeated Measurement Stability of 3D Tooth Model Obtained by Several Dental Scanners)

  • 배은정;김원수;임중연
    • 한국콘텐츠학회논문지
    • /
    • 제21권5호
    • /
    • pp.996-1003
    • /
    • 2021
  • 연구의 목적은 치과용 스캐너의 반복측정 안정성 비교를 통해 영향을 미치는 스캐너의 요소를 평가하는 것이다. 연구 목적을 달성하고자 청색광을 사용하는 I사의 스캐너와 광학 방식을 사용하는 Z사의 스캐너 그리고 백색광을 사용하는 D사의 스캐너를 본 연구의 반복측정 안정성 연구에 사용하였다. 측정 결과는 root mean square (RMS)로 계산하였고 one-way ANOVA 통계기법을 적용하여 유의수준을 확인하였다(𝛼=.05). 통계분석 결과 가장 큰 RMS 값을 가지는 스캐너는 Z-opt 그룹으로 38.2 ㎛이었다. 다음으로는 D-white가 35.2 ㎛로 나타났고, 가장 RMS 값이 적은 그룹은 I-blue 그룹으로 34.1 ㎛이었다. 각 그룹간에 RMS 평균을 비교한 결과는 유의하지 않은 것으로 나타났다(p>.05). 이 결과로부터 청색광, 백색광 그리고 광학 방식의 스캐너에서는 반복측정 안정성에서 청색광의 오차가 가장 낮은 것으로 나타났으나 통계적 유의성은 없었다. 연구결과 임상적 허용 가능하다는 것이 본 연구의 결론이다.

강아지에서 컨벡스스캐너를 이용한 정상적인 심장구조물의 초음파상 (Ultrasound Imaging of Normal Cardiac Structures with Convex Scanner in Puppies)

  • 정순욱;박희명;한숙희;윤정희;한홍율
    • 한국임상수의학회지
    • /
    • 제11권2호
    • /
    • pp.529-537
    • /
    • 1994
  • Sector scanner which has a conical end is used to image through the intercostal space because heart is protected by the ribs. Cardiac data published all around the world were also obtained by sector scanner. Although scanners being used in every small animal practice and animal hospital at college in Korea include convex ape and linear type, linear type is not appropriate f3r cardiac scan because of a wide contact surface. The purpose of this study is to establish ultrasonographic images of normal cardiac structures by measuring shape, size of reflectable cardiac structure according to restraint position in scanning normal heart of the puppies with 6.5 MHz convex scanner(SonoAce 4500, Medison, Korea) used in our veterinary teaching hospital, Seoul national university. Seventeen male and female puppies considered having healthy hear by X-ray and clinical examination are used feom April to July 1994. Scanning point selection of probe head and the distinction of imaged cardiac structures were accomplished by necropsy and cardiac scanning performed through thoracotomy under general anesthesia. At 10 o'clock position of transducer(at an angle of 30$^{\circ}$ between imaginary line from elbow joint to 3rd sternum and probe head, 60$^{\circ}$ from body surface, 4th intercostal space of right thorax) with the marker of scanner toward the head of dogs right atrium, left atrium and left ventricle were observed in 2, 3, 4, 5 intercostal space(2cm from the sternum) of experimental dog positioned ventrodorsally under general anesthesia. Under these conditions, the numerical values of imaged diastolic hear are as follows : the distance from skin to apex(mean$\pm$S.D) 47.53$\pm$6.94mm, thickness of left ventricular wall 6.00$\pm$1.60mm, length of left ventricle 16.27$\pm$5.31mm, width of left ventricle 15,33$\pm$4.25mm, length of left atrium 12.33$\pm$3.82mm, width of left atrium 11. 33$\pm$3.94mm, length of right atrium 1.00$\pm$2.41mm, width of right atrium 11.21$\pm$2.76mm and the area of left ventricle 270.92$\pm$109.81mm$^2$, area of left atrium 98.00$\pm$41.08mm$^2$, area of right atrium 62.75$\pm$21.04mm$^2$.

  • PDF

3D 발 스캐너와 3D 프린터를 이용한 남성화 라스트 설계 (Last Design for Men's Shoes using 3D Foot Scanner and 3D Printer)

  • 오설영;서동애;김형규
    • 한국콘텐츠학회논문지
    • /
    • 제16권2호
    • /
    • pp.186-199
    • /
    • 2016
  • 구두를 제작하는 기본 틀인 라스트는 3차원 형상과 관련된 정보와 기술이 총체적으로 집약된 결과물이다. 해외에서는 이미 3D 프틴팅 기술을 이용한 구두 제작이 상용화 단계에 도달하였으나, 국내에서는 아직 도입 초기 단계이다. 본 연구에서는 국내 제화산업의 경쟁력 확대를 위해, 3D 스캐닝, 3D 모델링, 3D 프린팅의 첨단 기술로 구성된 3D 제작 프로세스를 라스트 제작에 도입하였다. 이를 위해, 2010년도 SizeKorea에서 3D 스캔한 30대 남성 200명의 3D 발 형상을 사용하여, 요인분석, 군집분석을 실시하고, 3개의 발 유형을 분류한 후, 각 유형별 대표모델을 선정하였다. 대표모델들의 3D 스캐닝 형상에서 XY, YZ, XZ평면의 단면도들을 추출하고, 라스트 모델링의 스케치 단면으로 사용하였다. Solidworks CAD를 사용하여 라스트를 3D 모델링하였으며, 보급형 3D 프린터인 MakerBot Replicator2로 3D 프린팅 하였다. 본 연구 결과는 국내 제화산업에서 3D 프린팅 기술의 상용 가능성을 보여주었다. 3D 스캐닝, 3D 모델링, 3D 프린팅의 3단계 생산설계 방식은 향후 의류패션산업 전 분야에서 폭넓게 사용될 것으로 기대된다.

지상레이저스캐닝 기반 3차원 실내 모델링 (3D Indoor Modeling Based on Terrestrial Laser Scanning)

  • 홍승환;조형식;김남훈;손홍규
    • 대한토목학회논문집
    • /
    • 제35권2호
    • /
    • pp.525-531
    • /
    • 2015
  • 3차원 실내공간정보에 구축 시 경제성, 효율성 및 정확도 향상을 위한 지상레이저스캐너의 활용이 주목을 받고 있다. 그러나 실내공간정보 구축에 있어 지상레이저스캐너 관측방식과 기존 측량방식 방식에 대한 비교 연구는 미비한 실정이다. 본 연구에서는 설계도면 갱신 및 3차원 실내 모델링에 AMCW 방식 및 direct TOF 방식의 지상레이저스캐너와 토탈스테이션의 작업시간 및 위치정확도를 비교하여 지상레이저스캐너의 효율성과 경제성을 제시하였다. 비교결과, AMCW 방식은 direct TOF 방식에 비해 시간효율성이 뛰어났으며 두 관측값 사이의 RMSE는 ${\pm}1mm$ 수준으로 나타났다. 또한 지상레이저스캐닝 방식은 토탈스테이션 관측방식에 비해 2배 이상의 시간효율성을 보였으며 두 관측값 사이의 RMSE는 ${\pm}3.4cm$로 나타났다. 제시된 지상레이저스캐너를 이용한 3차원 실내모델링의 경제성과 효율성을 바탕으로 향후 3차원 실내공간 정보 구축에 지상레이저스캐닝 방식이 효과적으로 활용될 수 있을 것으로 기대된다.

3차원 의료기기용 초음파진단기 프로브 개발 (Development of a Ultrasound Probe for 3-D Ultrasonic Imaging)

  • 박종수;김성래;남윤수
    • 산업기술연구
    • /
    • 제25권A호
    • /
    • pp.87-93
    • /
    • 2005
  • Three-dimensional ultrasonic probes being applied to the medical imaging can be grouped into three depending on the scanning methods, which are a mechanical type system, a free-hand system, and 2D phased arrays system. A mechanical type scanner uses a mechanically driven transducer to acquire series of 2D plane images. By integrating these images, a 3-D medical image can be constructed. A motor driving mechanism is a conventional choice for mechanically driving a transducer assembly which picks the raw ultrasonic images up. In this paper we attempt to design a 3D ultrasonic probe which has a operating mechanism of s tilting 3-D scanning. The motion of a transducer assembly of the ultrasonic probe is analytically modelled. We propose a selection procedure for the diameter of a wire rope driving the transducer assembly and the size of torsional spring which gives an initial tension to wire ropes.

  • PDF