• 제목/요약/키워드: 2D scanner

검색결과 403건 처리시간 0.027초

단일 레이저 포인터를 이용한 저복잡도 휴대형 3D 스캐너 (Low-Complexity Handheld 3-D Scanner Using a Laser Pointer)

  • 이경미;이연경;박도영;유훈
    • 전기학회논문지
    • /
    • 제64권3호
    • /
    • pp.458-464
    • /
    • 2015
  • This paper proposes a portable 3-D scanning technique using a laser pointer. 3-D scanning is a process that acquires surface information from an 3-D object. There have been many studies on 3-D scanning. The methods of 3-D scanning are summarized into some methods based on multiple cameras, line lasers, and light pattern recognition. However, those methods has major disadvantages of their high cost and big size for portable appliances such as smartphones and digital cameras. In this paper, a 3-D scanning system using a low-cost and small-sized laser pointer are introduced to solve the problems. To do so, we propose a 3-D localization technique for a laser point. The proposed method consists of two main parts; one is a fast recognition of input images to obtain 2-D information of a point laser and the other is calibration based on the least-squares technique to calculate the 3-D information overall. To verified our method, we carry out experiments. It is proved that the proposed method provides 3-D surface information although the system is constructed by extremely low-cost parts such a chip laser pointer, compared to existing methods. Also, the method can be implemented in small-size; thus, it is enough to use in mobile devices such as smartphones.

직접측정과 3차원 측정에 따른 인체치수 및 의복 착장 비교분석 (Comparative Analysis of Body Measurement and Fit Evaluation between 2D Direct Body Measuring and 3D Body Scan Measuring)

  • ;임호선;천종숙
    • 복식문화연구
    • /
    • 제19권6호
    • /
    • pp.1347-1358
    • /
    • 2011
  • This study purposed to analyze differences in body measurement between the 2D direct body measuring method and the 3D body scan measuring method and to perform the appearance evaluation and cross-sectional evaluation of the fit of pants to which body measurements obtained by each measuring method were applied. Body measuring was conducted in 10 women in their 20s-30s using 2D direct body measuring and 3D automatic measuring with Hamamatsu body scanner. Among the 10 women, 3 participated in experimental garment wearing. Experimental pants were made using their 2D direct body measurements and 3D automatic measurements, and wearing tests were performed through expert evaluation and cross-sectional evaluation. The results of the experiment were as follows. According to the results of comparative analysis on differences between 2D direct body measurements and 3D scan measurements, 3D automatic measurements were significantly larger in bust circumference, ankle circumference, armscye circumference, shoulder length, scye depth, and arm length. As circumferences measured with the 3D body scanner were somewhat larger than directly measured ones, it is suggested to adjust ease when using existing pattern making methods. We prepared experimental garments by the same pattern making method through applying body measurements obtained with the two measuring methods, and assessed the fit of the garment comparatively through expert evaluation and 3D scan cross-sectional evaluation. According to the results, 2D-pants using 2D direct body measurements was slightly tighter than 3D-pants using 3D measurements in waist circumference, hip circumference, and abdominal circumference. In the results of comparing appearance in terms of the fit of the experimental garment in each subject, significant difference was observed in most of the compared items. This result suggests that 3D automatic body measuring data may show different accuracy according to body shape and therefore it is necessary to examine difference between 2D direct body measurements and 3D automatic measurements according to body shape.

분리된 마스트에 설치되는 선체고정 위상 배열 레이더의 기계적 정렬 (Mechanical Alignment of Hull Mounted Phased Array Radar on the Separated Mast)

  • 서형필;김대한;김준우;이경진;조규룡
    • 한국산학기술학회논문지
    • /
    • 제20권9호
    • /
    • pp.465-473
    • /
    • 2019
  • 본 논문은 4면 선체 고정형 위상 배열 레이더를 부착하기 위한 2개의 분리된 마스트를 해군 함정에 정확하게 탑재하기 위한 기계적 정렬 방법과 정렬을 위한 3D 스캐너를 활용한 계측 방법에 대해 연구하였다. 선체 고정 위상 배열레이더는 초고주파를 사용하므로 짧은 파장으로 인해 작은 위치오차에도 이로 인한 소자의 위상차이가 발생할 수 있고 배열 안테나가 선체 고정식이므로 4개의 배열 면에 대해 회전형 레이더 보다 높은 정도 관리(accuracy control)가 필수적이다. 육상 공장에서 제작된 2개의 레이더용 마스트에 대한 편평도 확인 방법, 마스트들을 함정에 탑재하기 위해 정렬을 하는 방법과 4개의 array 부착용 Pad 가공 면에 대해 정렬하는 방법을 도출하였다. 이에 대한 도구로 3D 레이저 스캐너에 의한 측량과 측량 결과를 3D CAD와 비교하기 위한 소프트웨어 활용의 방법이 사용된다. 이 논문은 한국 해군함정에서 분리된 마스트에 4면 선체 고정 위상 배열 레이더를 설치하고 기계적 정렬 방법을 도출한 최초의 사례로서 의미가 있다.

팔 동작에 따른 소매유무별 블라우스 착의형상의 3차원적 파악 (A Study on the Dressed Shapes of the Blouse with Short Sleeves and Sleeveless according to Arm Movement Using 3-D Scanner)

  • 이명희
    • 한국의류산업학회지
    • /
    • 제8권2호
    • /
    • pp.209-213
    • /
    • 2006
  • The 3-D information is useful as basic data which has been utilized in the development of simulating technology as fit-simulation. The experiment is designed to take some useful data on the variant shapes which contribute in simulating the adaptability of the clothes. The general figure of the clothes are made after the figure of the basic standing posture of the human body. The shape of the clothes fits with kinetic characteristic of the human body as the form of the clothes gets twisted, the ease of the clothes changes, and the clothes itself expands. We studied the dressed shapes of blouse according to two types of the arm movement(basic posture and reach forward) and three types of clothes(foundation, blouse with short sleeves and sleeveless) in the sit-down-posture. We accomplished some experimental data on three-dimensional measurement of the dressing shapes using TDS-3100 3-D scanner made in Japan PULSTECH. It is considered that the variant of shapes and distribution of gaps in the dressed shapes of blouse are determined by the adaptability of clothes made in arm movement.

3-Dimensional scan을 이용한 치아 마모량 측정 방법에 관한 연구 (A NOVEL 3D SCAN METHOD TO QUANTIFY TEETH WEAR)

  • 김승준;최대균;권긍록;이석형
    • 대한치과보철학회지
    • /
    • 제42권1호
    • /
    • pp.1-10
    • /
    • 2004
  • Statement of problem : Tooth wear is physiological phenomenon. Ninety-seven percent of normal people have tooth wear and about 7% has pathologic teeth wear. If we know the amount of tooth surface loss caused by pathologic tooth wear, we may restore it ideally Purpose : Recently measurement of tooth wear by using 3D scan has been increasing. Therefore, we need to know how accurate 3D scan is. Past accuracy test on 3D scan was about linear change, but as we know that tooth wear is volume change. Thus, the purpose of this study is to know how accurate 3D scan is. Material and Methods : For accuracy test of 3D scanner volume values measured by 3D scanner and micro-balance were compared. For test I, preliminary, 3 ball samples and 3 circular cones were made with pattern resin. For test II, 10 teeth shape rubber samples were used. Results and Conclusion : 1. The result of the accuracy test on 3D scan with 3 ball samples and 3 circular cones made of pattern resin has no significant difference(p<0.05). 2. The result of the accuracy test on 3D scan with 10 samples of tooth shape rubber has no significant difference (p<0.05). As a result, we may concluded the analysis of quantifying tooth wear used by 3D scan is useful in the clinic.

레이저 스케너 센서기반 보행패턴 인식 및 경로추적 (Tracking of Person Walking Pattern and Trajectory Following with 2D Laser Scanner)

  • 진태석
    • 전기학회논문지
    • /
    • 제67권7호
    • /
    • pp.903-909
    • /
    • 2018
  • We propose laser scanner sensor system based walking pattern and tracking method of multiple human. This system uses laser scanners sensors and is applicable to wide and crowded area such as hospital and medical care center. The primary objective of this research is to promote the development of robust, repeatable and transferable software for security system that can automatically detect, track and follow people in public area. We developed the method of human identification for this system. Our method is following: 1. Best-walking pattern data are obtained by the help of human position and direction data obtained by laser scanners. 2. Human identification is conducted by calculating the correlation between the step length of walking human. It becomes possible to conduct human identification even in crowded scenes by estimating the movements of waling human' feet are periodic. In the experiment in the station, some effectiveness of this method became clear.

ICP 알고리즘을 이용한 2차원 격자지도 보정 (2D Grid Map Compensation using an ICP Algorithm)

  • 이동주;황요섭;윤열민;이장명
    • 제어로봇시스템학회논문지
    • /
    • 제20권11호
    • /
    • pp.1170-1174
    • /
    • 2014
  • This paper suggests using the ICP (Iterative Closet Point) algorithm to compensate a two-dimensional map. ICP algorithm is a typical algorithm method using matching distance data. When building a two-dimensional map, using data through the value of a laser scanner, it occurred warping and distortion of a two-dimensional map because of the difference of distance from the value of the sensor. It uses the ICP algorithm in order to reduce any error of line. It validated the proposed method through experiment involving matching a two-dimensional map based reference data and measured the two-dimensional map.

AFM 시스템을 위한 XYZ 3축 스테이지의 설계 (The design of XYZ 3-axis stage for AFM system)

  • 김동민;김기현;심종엽;권대갑;엄천일
    • 한국결정학회:학술대회논문집
    • /
    • 한국결정학회 2002년도 정기총회 및 추계학술연구발표회
    • /
    • pp.36-36
    • /
    • 2002
  • To Establish of standard technique of length measurent in 2D plane, we develope AFM system. The XY scanner scans the sample only in XY plane, while the Z scanner scans the specimen only in Z-direction. Cantilever tip is controlled to has constant height relative to speciman surface by feedback of PSPD signal. To acquire high accuracy, Z-axis measuring sensor will be added.(COXI or others). In this paper we design XYZ stage suitable for this AEM system. For XY stage, single module parallel-kinnematic flexure stage is used which has high orthogonality and minimum out-of-plane motion. To obtain best performance optimal design is performed. For XY stage, to be robust about parasitic motion optimal design of maximizing Z and tilt stiffness is performed under the constraint of motion range and stage size. And for Z stage, optimal design of maximizing 1st resonant frequency is performed. Because if resonant frequency is get higher, scan speed is improved. So it makes reduce the error by sensor drift. Resultly XYZ stage each have 1st natural frequency of 115㎐, 201㎐, 2.66㎑ and range 109㎛, 110㎛, 12㎛.

  • PDF

안면 수기 마사지 후 안모의 변화 (The Change of Facial Contouring after Facial Massage)

  • 임은진;위수영;정다운;김성택
    • 구강회복응용과학지
    • /
    • 제28권1호
    • /
    • pp.103-108
    • /
    • 2012
  • 본 연구는 안면수기 마사지 시술 후 얼굴 부피 및 두께의 안모 변화를 평가하기 위해 20~40대 여성 10명을 선정하여 주 2회, 20회의 시술을 10주간 진행하였으며, Vivid 9i$^{(R)}$ laser scanner(Minolta, Tokyo, Japan)를 사용해서 마사지 관리 전과 마사지 관리 후의 부피 변화를 비교하였다. 결과, 수기 마사지 후 얼굴 부피는 평균 $731mm^3$ 정도로 다소 감소하였으며(p>.05), 광대뼈 부위의 두께는 평균 0.40mm로 감소하였고(p<.05) 저작 부위의 두께 변화는 평균 0.44mm로 감소하였다(p<.05) 이에 얼굴 수기마사지에 의한 안모 변화는 부피와 광대뼈 및 저작 부위에서 변화가 나타났음을 알 수 있다. 이는 비침습적이면서 비교적 안전한 방법으로 비대칭 및 저작근 비대 등으로 인한 얼굴형 변화를 개선하는데 긍정적 효과를 줄 것으로 사료된다.