• Title/Summary/Keyword: 2D scanner

Search Result 403, Processing Time 0.03 seconds

Validation of a low-cost portable 3-dimensional face scanner

  • Liu, Catherine;Artopoulos, Andreas
    • Imaging Science in Dentistry
    • /
    • v.49 no.1
    • /
    • pp.35-43
    • /
    • 2019
  • Purpose: The goal of this study was to assess the accuracy and reliability of a low-cost portable scanner (Scanify) for imaging facial casts compared to a previously validated portable digital stereophotogrammetry device (Vectra H1). This in vitro study was performed using 2 facial casts obtained by recording impressions of the authors, at King's College London Academic Centre of Reconstructive Science. Materials and Methods: The casts were marked with anthropometric landmarks, then digitised using Scanify and Vectra H1. Computed tomography (CT) scans of the same casts were performed to verify the validation of Vectra H1. The 3-dimensional (3D) images acquired with each device were compared using linear measurements and 3D surface analysis software. Results: Overall, 91% of the linear Scanify measurements were within 1 mm of the corresponding reference values. The mean overall surface difference between the Scanify and Vectra images was <0.3mm. Significant differences were detected in depth measurements. Merging multiple Scanify images produced significantly greater registration error. Conclusion: Scanify is a very low-cost device that could have clinical applications for facial imaging if imaging errors could be corrected by a future software update or hardware revision.

Accuracy and Precision of Three-dimensional Imaging System of Children's Facial Soft Tissue (소아 얼굴 연조직의 3차원 입체영상의 정확성 및 재현성 평가)

  • Choi, Kyunghwa;Kim, Misun;Lee, Koeun;Nam, Okhyung;Lee, Hyo-seol;Choi, Sungchul;Kim, Kwangchul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.1
    • /
    • pp.17-24
    • /
    • 2020
  • The purpose of this study was to evaluate the accuracy and precision of the three-dimensional (3D) imaging system of children's facial soft tissue by comparing linear measurements. The subjects of the study were 15 children between the ages of 7 and 12. Twenty-three landmarks were pointed on the face of each subject and 16 linear measurements were directly obtained 2 times using an electronic caliper. Two sets of 3D facial images were made by the 3D scanner. The same 16 measurements were obtained on each 3D image. In the accuracy test, the total average difference was 0.9 mm. The precision of 3D photogrammetry was almost equivalent to that of direct measurement. Thus, 3D photogrammetry by the 3D scanner in children had sufficient accuracy and precision to be used in clinical setting. However, the 3D imaging system requires the subject's compliance for exact images. If the clinicians provide specific instructions to children while obtaining 3D images, the 3D device is useful for investigating children's facial growth and development. Also the device can be a valuable tool for evaluating the results of orthodontic and orthopedic treatments.

Optimal design of a flexure hinge-based XY AFM scanner for minimizing Abbe errors and the evaluation of pitch measuring uncertainty of a nano-accuracy AFM system (XY 스캐너의 아베 오차 최소화를 위한 최적 설계 및 나노 정밀도의 원자 현미경 피치 측정 불확도 평가)

  • Kim Dong-Min;Lee Dong-Yeon;Gweon Dae-Gab
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.6 s.183
    • /
    • pp.96-103
    • /
    • 2006
  • To establish of standard technique of nano-length measurement in 2D plane, new AFM system has been designed. In the long range (about several tens of ${\mu}m$), measurement uncertainty is dominantly affected by the Abbe error of XY scanning stage. No linear stage is perfectly straight; in other words, every scanning stage is subject to tilting, pitch and yaw motion. In this paper, an AFM system with minimum offset of XY sensing is designed. And XY scanning stage is designed to minimize rotation angle because Abbe errors occur through the multiply of offset and rotation angle. To minimize the rotation angle optimal design has performed by maximizing the stiffness ratio of motion direction to the parasitic motion direction of each stage. This paper describes the design scheme of full AFM system, especially about XY stage. Full range of fabricated XY scanner is $100{\mu}m\times100{\mu}m$. And tilting, pitch and yaw motion are measured by autocollimator to evaluate the performance of XY stage. As a result, XY scanner can have good performance. Using this AFM system, 3um pitch specimen was measured. The uncertainty of total system has been evaluated. X and Y direction performance is different. X-direction measuring performance is better. So to evaluate only ID pitch length, X-direction scanning is preferable. Its expanded uncertainty(k=2) is $\sqrt{(3.96)^2+(4.10\times10^{-5}{\times}p)^2}$ measured length in nm.

Development of Indoor Structure Scanner using 2D LIDAR (2D 라이다를 이용한 실내 구조 스캐너 개발)

  • Ki-Jun Kim;Jae-Hyoung Park;Hyun-Min Moon;Ha-Eun Lee;Seung-Dae Lee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.6
    • /
    • pp.1189-1196
    • /
    • 2023
  • Due to the acceleration of urbanization and advancements in technology, the importance of information related to indoor spaces has been increasing. Various scanning technologies are being developed to enable versatile utilization of the interior of buildings. In this paper, a system is proposed that utilizes 2D LIDAR for scanning, rotating, and moving LIDAR in the vertical direction to obtain a collection of 2D data, which is then aggregated to acquire 3D indoor spatial information. Finally, algorithms, including error correction, are applied to visualize the indoor structure in three dimensions and generate an output.

Rapid Fabrication of Large-Sized Solid Shape using 3D Scanner and Variable Lamination Manufacturing : Case Study of Mount Rushmore Memorial (삼차원 스캐너와 가변 적층 쾌속조형공정을 이용한 대형 입체 형상의 쾌속 제작 : 러쉬모어산 기념물 제작 사례)

  • 이상호;김효찬;송민섭;박승교;양동열
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.12
    • /
    • pp.1958-1967
    • /
    • 2004
  • This paper describes the method to rapidly fabricate the large-sized physical model with the envelope model size of more than 600 mm${\times}$ 600 mm${\times}$ 600 mm using two type semi-automatic VLM-ST processes in connection with the reverse engineering technology. The fabrication procedure of the large-sized solid shape is as follows: (1) Generation of STL data from 3D scan data using 3D scanner, (2) generation of shell-type STL data by Boolean operation, (3) division of shell-type STL data into several pieces by solid splitting, (4) generation of USL data for each piece with VLM-Slicer, (5) fabrication of each piece by cutting and stacking according to USL data using VLM-ST apparatus, (6) completion of a shell-type prototype by zigzag stacking and assembly for each piece, (7) completion of a 3D solid shape by foam backing, (8) surface finish of a completed 3D solid shape by coating and sanding. In order to examine the applicability of the proposed method, the miniature of the Mount Rushmore Memorial has been fabricated. The envelope model size of the miniature of the Mount Rushmore Memorial is 1,453 mm${\times}$ 760 mm${\times}$ 853 mm in size. From the result of the fabricated miniature of the Mount Rushmore Memorial, it has been shown that the method to fabricate the large object using two type semi-automatic VLM-ST processes in connection with the reverse engineering technology are very fast and efficient.

Classification of Elderly Men's Foot Side Type from 3D Scan Data (3차원 스캔 데이터에 의한 노년 남성의 발 측면유형 분류)

  • Kim, Nam-Soon;Do, Wol-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.38 no.4
    • /
    • pp.427-439
    • /
    • 2014
  • This study identifies the foot side shapes of elderly men by classifying foot types according to 3D foot shapes and analyzing individual characteristics. The subjects were 284 elderly men over 60 years of age who lived in Gwangju and did not have foot related diseases. They were measured with a scanner (Nexcan$^{(R)}$ of K&I Technology) to obtain three dimensional feet shapes. Anthropometric measuring items consisted of 28 items estimated on the right foot of each subject. 3D scan data were analyzed by various statistical methods such as factor analysis, ANOVA and cluster analysis using the statistical program SPSS 19.0. A total of 7 factors were extracted through a factor analysis and these factors represent 77.56% of total variance. The 8 factors were: inside height and side gradient, ankle thickness, size from foot center to ankle, lateral malleolus height, forefoot height, instep and heel height and gradient. A total of 3 clusters (as foot type) were categorized using 7 factor scores by cluster analysis. Type 1 was classified as high forefoot and low midfoot compared to the length. Type 2 was classified as low forefoot and high midfoot, and type 3 was classified as low forefoot and low midfoot.

A study on the core technologies for industrial type digital 3D SFF system

  • Kim, Dong-Soo;An, Young-Jin;Kim, Sung-Jon;Choi, Byung-Oh;Lim, Hyun-Eui
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2170-2174
    • /
    • 2005
  • Selective Laser Sintering (SLS) is a useful rapid prototyping technique for the manufacture of three dimensional (3D) solid objects directly from a scanning data. A new approach called a Selective Multi-Laser Sintering (SMLS) system has been developed at Korea Institute Machinery & Materials (KIMM) as an industrial type SFFS. This SMLS machine is built with a frame, heaters, nitrogen supply part, laser system. This system uses the dual laser and 3D scanner made in $Solutionix^{TM}$ to improve the precision and speed for large objects. The three-dimensional solid objects are made of polyamide powder. The investigation on each part of SMLS system is performed to determine the proper theirs design and the effect of experimental parameters on making the 3D objects. The temperature of the system has a great influence on sintering the polymer. Because the stability of the powder temperature prevents the deformation of each layer, the controls of the temperature in both the system and the powders are very important during the process. Therefore, we simulated the temperature distribution of build room using the temperature analysis with ANSYS program. Selected radiant heater is used to raise temperature of powder to melting point temperature. The laser parameters such as scan spacing, scan speed, laser power and laser delay time affect the production the 3D objects too. The combination of the slow scan speed and the high laser power shows the good results without the layer curling. The work is under way to evaluate the effect of experimental parameters on process and to produce the various objects. We are going to experiment continuously to improve the size accuracy and surface roughness.

  • PDF

Comparative study on the Shape between a Customized Finger Made by 3D Printing Technology, Real Small Finger, a plaster Small Finger, Based on CT Data (CT data 기반 3D 프린팅으로 제작된 Small Finger, 실제 Small Finger 그리고 석고 Small Finger 형상 비교 연구)

  • Choi, Hyeun-Woo;An, Do-Hyun;Rhee, Do-byung;Lee, Jong-Min;Seo, Anna
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.153-158
    • /
    • 2019
  • The purpose of this study is to compare and analyse the differences between a customized small finger made by 3D printing technology, a real small finger, and the other made from plaster of an orthotic company. The areas and the volumes of each cross-section were measured by Computer tomography(CT) and a 3D scanner and analysis of variance was performed to find out the differences of each shape. The areas of the point of 15.69mm, Distal Interphalangel Joints, were measured 30 times respectively using the caliper toll function of Picture Archiving Communication System(PASC) program. The volumes were measured by Configure Units of Meshmixer Program. There was no significant difference in the areas between three of them and there was 0.2 mm gap in the volume, which was more than the significance probability. Therefore, the result of this study shows the availability of finger orthoses made by 3D printing technology in the medical field.

Design and Analysis of Wire Classification Device using the 2D Scanner (2D 스캐너를 이용한 선재 위치 분류장치의 설계와 해석)

  • Ryu, Hwan-Gyu;Ryu, Jeong-Gyu;Kim, Jeong-Ho
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2013.11a
    • /
    • pp.449-452
    • /
    • 2013
  • 최근 산업, 무역 및 유통 기업들은 수 많은 물류 자원에 IT 기술이 도입되어 운용되고 있다. 이러한 기업들은 물류 비용을 절감하기 위해 자동차 생산 분류와 물류 수송 부분으로 이어진다. 물류 분야 중 자동차 생산 분류에 선재 관리를 통해 기업과 기업으로 서로 운송되어 분류되어 있으며, 차량 선재 분배를 위해 POS에서 나온 데이터를 바코드를 사용하게 된다. 그러나, 이러한 선재의 문제점은 작업자의 분류지를 일일이 보면서 확인을 통해 작업을 하고 있으며, 작업자의 누락 혼합 발생된 물류 납품시 타사 기업으로 선재의 혼합, 누락 등으로 2차적 피해가 발생하게 된다. 따라서, 본 연구에서는 차량 선재의 분류에 대한 2D 스캐너 기반의 프로세서와 시스템을 포함하고 선재 물류 분류 장치를 통해 특성을 설계하고 현장을 개선하고자 한다.

NONLINEAR CONTRAST ENHANCEMENT ON SUBTRACTION IMAGES (계수공정영상의 비선형 대조도 증강효과에 관한 연구)

  • Lee Keon-Il;Jin Yeun-Hwa
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.2
    • /
    • pp.83-90
    • /
    • 1997
  • This study was performed to demonstrate the effect of linear or nonlinear contrast enhancement on subtraction images. Three different textures were radiograped on dental film. The first radiograph was taken without the presence of an object. the second, which showed trabucular bone, was taken of the molar area of a human. the third radiograph was taken of the coronal part of molars. Each film was digitized into a 1312 x 1024 pixel x 8 bit depth matrix by means of a Nikon 35 mm film scanner(LS-3510AF, Japan) with fixed gain and internal dark current correction to maintain constant illumination. The scanner was interfaced to a Macintosh Le ill computer(Apple Computer, Charlotte, N.C) This resulted in three pairs of images, including different textures-plain, bone and enamel. Digital regular, linearly and nonlinearly enhanced subtraction was performed. Computer software was ,used to simulate lesions in the shape of a 2D-Gaussian curve on each of a pair of images. The each subtraction images were presented in a random sequence to two groups of 10 observers(students and dentists). ROC analysis was used to compare observer performance. The following results were obtained ; 1. All of LCE subtraction, equalized subtraction and regular subtraction images of plain texture were diagnosed the best by far. 2. The data revealed a siginificant LCE effect in both the student group and the expert group. 3. Clinical expertise was a helphul factor for the observers in this study.

  • PDF