• 제목/요약/키워드: 2D position measurement

검색결과 187건 처리시간 0.031초

30대 여성 유방형태 분류에 관한 연구 (A Study on Classification of Breast Shapes for Women in Their 30s)

  • 김효숙;김지민
    • 복식
    • /
    • 제64권4호
    • /
    • pp.106-117
    • /
    • 2014
  • The purpose of this study is to provide basic information for the development of well-fitting and comfortable brassieres for women in their 30s, based on the classification of breast shapes by utilizing 3D body measurement data of women in the age group. The result of processing the measurements from the 3D body scan data through RapidForm 2006 shows that while the vertical body measurements decrease, the horizontal measurements, which indicates the degree of obesity, increase proportionally with age. Also, the relevant measurements for upper breasts increase proportionally with age, while the measurements for lower part of the breasts decrease as the degree of sagging increases. Four composition factors of the breasts were identified through the factor analysis: Factor 1 is the level of volume in the breasts and the surrounding area; Factor 2 is the position of nipples and the shape of upper part of breasts; Factor 3 is the position and vertical length of the breasts; Factor 4 is the shape of lower part of breasts; and Factor 5 is the shape of inner part of breasts and degree of width between both breasts. The breasts have been categorized into three distinctive shapes: Breast Shape 1, Breast Shape 2 and Breast Shape 3. According to the results of the cluster analysis, the largest percentage (36.68%) of women in their 30s falls into the category of Breast Shape 2 with small volume and flat upper breasts, followed by Breast Shape 1 (32.66%) with large volume in the upper and lower parts of breasts, and large side to side area, and Breast Shape 3 (30.65%) with average volume and width between breasts.

Memory Effect를 최소화한 C-대역 내부 정합 GaAs 전력증폭기 (C-Band Internally Matched GaAs Power Amplifier with Minimized Memory Effect)

  • 최운성;이경학;어윤성
    • 한국전자파학회논문지
    • /
    • 제24권11호
    • /
    • pp.1081-1090
    • /
    • 2013
  • 본 논문에서는 C-대역에서 입출력 정합 회로가 패키지에 내장된 10 W급 내부 정합 증폭기 설계 및 제작을 하였다. 전력증폭기 설계에 사용한 트랜지스터로 GaAs pHEMT bare-chip을 사용하였다. 트랜지스터 패드 위치와 커패시터 크기를 고려한 와이어 본딩 해석으로 정확도 높은 설계를 하였다. 패키지와 정합 회로를 함께 EM simulation하여 패키지가 정합 회로에 미치는 영향을 해석하였다. 2-tone 측정 시 memory effect로 인해 발생되는 IMD3의 비대칭성을 줄이기 위한 memory effect 감쇄 바이어스 회로를 제안 및 설계하였다. 측정 결과, 7.1~7.8 GHz 대역에서 $P_{1dB}$는 39.8~40.4 dBm, 전력 이득은 9.7~10.4 dB, 효율은 33.4~38.0 %을 얻었고, 제안된 memory effect 감쇄 바이어스 회로로 IMD3(Upper)와 IMD3(Lower)차는 0.76 dB 이하를 얻었다.

2계 미분기를 이용한 자화플라즈마의 전자에너지 분포함수의 측정에 관한 연구 (A Study on the Measurement of Electron Energy Distribution Function in Magnetoplasma with 2-stage Differentiators)

  • 김두환;성열문;신중홍;손재봉;조정수;박정후
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1311-1313
    • /
    • 1995
  • In this paper, We can obtain Electron energy distribution function(EEDF) by using two Differentiators. In addition, We investigate the characteristics of EEDF as function of the position of probe, magnetic field, and pressure.

  • PDF

중형카메라 RCD105 정확도 분석 (Accuracy Analysis of Medium Format CCD Camera RCD105)

  • 김태훈;원재호;김충평;소재경;윤희천
    • 한국측량학회지
    • /
    • 제28권4호
    • /
    • pp.449-454
    • /
    • 2010
  • 최근 항공측량분야에서 항공디지털카메라 및 항공레이저측량시스템은 수치정사영상지도 및 수치표고모델제작 등의 지리정보 구축에 활용되고 있다. 본 연구에서는 항공레이저측량시스템인 ALS50-II에 구성된 중형CCD카메라 RCD105의 3차원 위치정확도를 디지털항공사진카메라인 DMC와 비교하였다. 이를 위해 연구지역을 선정하고 항공사진촬영을 실시하였으며, 축적 1:1,000 수치지형도에서 항공삼각측량에 사용할 지상기준점과 수치도화기를 이용해 평면 및 수준정확도 검증에 사용할 검사점을 선점하였다. RCD105와 DMC의 정확도는 항공삼각측량의 결과와 수치도화기를 이용해 검사점과 동일한 지점을 관측한 결과로 평가하였다. 항공삼각측량 결과 RCD105의 X, Y, Z RMSE (Root Mean Square Error)가 DMC보다 각각 2.1배, 2.2배, 1.3배 크게 나타났다. 또한 수치도화기를 이용해 검사점을 관측한 결과 RCD105의 평면 및 수직방향 RMSE가 DMC보다 각각 2.5배, 4.3배 크게 나타났다. RCD105의 정확도가 DMC보다는 떨어지지만, RCD105도 수치지형도 및 정사사진 제작에 활용이 가능할 것으로 사료된다.

3차원 음향홀로그래픽을 이용한 음원위치 추정에 관한 연구 (A Study Absolute Position Estimation of Sound Source)

  • 김천덕;심동연;장비;이채봉;차경환
    • 한국음향학회지
    • /
    • 제16권5호
    • /
    • pp.76-82
    • /
    • 1997
  • 본 논문은 음원의 절대위치를 정확하게 추정할 수 있는 음향홀로그래픽법에 관하여 계산기상의 시뮬레이션 및 측정시스템을 이용한 실험과결과에 대하여 서술한다. 이 연구에서는 원거리 음장을 만족하도록 측정면을 설정하여 7개의 마이크로폰을 직선으로 배열한다. 음원의 측정은 음원면에 근접한 위치에 한 개의 기준 마이크로폰을 설치하고 측정면의 마이크로폰들을 등간격으로 스캐닝하면서 각지점의 음을 동시 기록한다. 수음한 기준음과 측정음간의 크로스 스펙트럼 알고리즘에 의하여 음원의 절대위치를 측정한다. 그리고 각 마이크로폰의 위상차는 기준 마이크로폰을 대상으로 위상보상 하였으며, 측정시의 시간지연은 제 1열 측정시점을 기준으로 시간보상을 행하였다. 측정면에 설정한 마이크로폰들의 최적 간격은 수치 시뮬레이션에 의하여 정한다. 음원신호는 정현파를 이용하고 S/N비를 30dB의 조건하에서 각각 실험을 행하였다. 시뮬레이션과 실험에서 결정한 최적 마이크로폰 간격은 2KHz인 정현파 음원을 기준으로 하여 공간상의 나이키스트 조건을 만족하도록 설정하였다. 무향실에서 측정한 실험결고, 500Hz 와 1KHz의 신호원에 대한 음원이 2KHz인 경우의 추정된 3차원 홀로그램의 주극폭이 각각 87%와 30%씩 감소하였고, 그 결과 수치 시뮬레이션의 타당성을 확인할 수 있었다. 그러므로 본 연구에서 제안하는 3차원 음향 홀로그래픽법을 이용한 음원위치 추정에 관한 연구의 유용성을 검증하였다.

  • PDF

Increase In Mean Alveolar Pressure Due To Asymmetric Airway Geometry During High Frequency Ventilation

  • Cha, Eun-J.;Lee, Tae-S.;Goo, Yong-S.;Song, Young-J.
    • 대한의용생체공학회:의공학회지
    • /
    • 제14권1호
    • /
    • pp.89-96
    • /
    • 1993
  • During high frequency ventilation (HFV), mean alveolar pressure has been measured to increase with mean airway opening pressure controlled at a constant level in both humans and experimental animals. Since this phenomenon could potentiate barotrauma limiting advantages of HFV, the present study theoretically predicted the difference between menu alveolar and airway opening pressures ($MP_{alv}$). In a Weibel's trumpet airway model, approximated formula for $MP_{alv}$ was derived based on momentum conservation assuming a uniform velocity profile. The prediction, equation was a func pion of gas density($\rho$), mean flow rate(Q), and diameter of the airway opening where the pressure measurement was made($D_0$) : $MP_{alv}=4{\rho}(Q/D_0^{2})^2$. This was a result of the difference in crosssectional area between the alveoli and the airway opening. A simple aireway model experiment was performed and the results well fitted to the prediction, which demonstrated the validity of the present analysis. Previously reported $MP_{alv}$ data from anesthetized dogs in supine position were comparable to the predicted values, indicating that the observed dissociation between mean alveolar and airway opening pressures during HFV can be explained by this innate geometric (or cross-sectional area) asymmetry of the airways. In lateral position, however, the prediction substantially underestimated the measurements suggesting involvement of other important physiological mechanisms.

  • PDF

국내.외 브래지어의 패턴비교분석 및 착의평가 연구 (Comparative Pattern Analysis and the Fitness Evaluation of Brassieres)

  • 서추연
    • 한국의류학회지
    • /
    • 제34권4호
    • /
    • pp.673-685
    • /
    • 2010
  • This study evaluates the fitness of brassieres through size measurement, comparative pattern analysis, cross section map analysis, 3-D shape analysis number, and fitness evaluation with a focus on domestic and overseas brands. Experimental brassieres were selected as mold brassieres of 3/4 cup in 75A size that is considered a popular design. Brands of selected brassiere were 2 domestic brands (A, B), 1 licensed brand (C), and 2 overseas brands (D, E). Subjects were 8 women in their early 20's. Data were analyzed by descriptive statistics, analysis of variance, reliability analysis, and factor analysis. The results were as follows; the size and pattern of brassieres showed a difference by each brand even though brassieres are the same design. In the wearing effect of brassieres, overseas brand brassieres played a major role in the breast-up effect, but they were not appropriate for the somatotype of Korean women. Domestic brand brassieres showed the volume-up effect, that was confirmed by the increasing bust circumference, bust depth when subjects wore it. In addition, the licensed brand brassieres showed the correction effect of body shape. Therefore, when purchasing a brassiere, the most important condition is to consider the individual characteristics of the somatotype. The results of factor analysis through a functional evaluation show that wearing satisfaction, size satisfaction, and the position of the bust point were important factors for fitness satisfaction and purchase.

SERVQUAL 모델을 이용한 간호 서비스 질 측정 (Measurement of Nursing Service Quality using SERVQUAL Model)

  • 임지영;김소인
    • 간호행정학회지
    • /
    • 제6권2호
    • /
    • pp.259-279
    • /
    • 2000
  • This study is a descriptive analytic research measuring nursing service quality, using SERVQUAL model, to make fundamental data and strategies for nursing service improvement. Data were collected by self-reported questionnaire from 202 patients and 142 nurses, from June 7 to 14, 1999. The reliability of instrument were adequate(Cronbach ${\alpha}=.94$). SAS program was utilized for statistical analysis of collected data. The results were as follows; 1. There was a gab between patient's expectation and perception on nursing service(Gap B). Gap D was indicated an affecting factor to decide nursing service quality. Gap C was indicated an indirect affecting factor of nursing service quality. Because it was not statistically significant in total item analysis, but in individual item analysis, 7 items were appeared statistically significant. Gap A was not a gap occurrence factor of nursing service quality. 2. Focuses of nursing service quality improvement strategies were; (1) to direct qualitative improvement of nursing service in order to correspondence patient's nursing service expectation. (2) to make nurse's service activity modified because nurse's practice were not reached patient's expectation level. (3) to need internal, external factor analysis affecting nurse's service activity. 3. Nursing service quality was decided by rather environmental inappropriateness provided nursing service than itself. Therefore, to make nursing service quality improvement, it is required to improve nursing service environment. For this, followings are required; (1) to strengthen nurse's education on lower part of nursing service satisfaction and QI activities. (2) to balance demand and supply of nursing personnel. 3) to fix computerized system for reducing other duties weight except nursing care through analysis of nursing activity. (4) to construct rational cooperating system among related departments. 4. The important parts for nursing service quality improvement were indicated as follows: (1) Gap B: 'prompt reaction', 'examination symptom before patient's complaint', 'hearted nursing service reducing patient's dissatisfaction', 'explanation goals of nursing activities', 'having special Knowledge enough', 'maintenance position comfortably', 'management of patient's physical hygiene'. (2) Gap C: 'maintenance physical safety', 'explanation about hospital rules and facilities'. (3) Gap D: 'tender, safe injection and wound care'. Because above items are mostly improved through nurse's attitude change and quality improvement, it is required to establish nursing standardization and to strengthen nurse's clinical education. As the based on above results, followings are suggested; 1. SERVQUAL model is very useful to make strategies for nursing service quality improvement because it indicates multiple factors affecting hap occurrence. 2. At individual items analysis of Gap C, statistically significant 7 items appeared higher nurse's perception level than patient's perception level on nursing service were trouble perception level on nursing service quality improvement. So. it need further research to analysis about these difference occurring factors. 3. At analysis of Gap D, it is indicated that in nursing service performance process, multiple factors lowing nursing service quality were intruded. So it needs further research to analysis what these factors are and how each factors affect on nursing performance process. 4. nursing service quality measurement is changeable according to sample select time or sampled subject's characteristics. So to develope strategy for nursing service quality improvement is based on the results of periodical analysis.

  • PDF

작업자세에 따른 어깨근육의 작업부하 측정 (Measurement of Shoulder Muscle Workload at Various Working Postures)

  • 김정룡;박지수;박창순;편흥국
    • 대한산업공학회지
    • /
    • 제25권2호
    • /
    • pp.266-273
    • /
    • 1999
  • The maximum work capacity at various shoulder angles was estimated in terms of joint moment through maximum voluntary contraction (MVC) measurement, and the result was compared to workload computed from 3-D static lifting model (3DSSPP) based upon national institute of safety and health (NIOSH) lifting guideline (1991). The electromyography (EMG) of anterior/posterior deltoid and trapezius muscle was also recorded to study the function of individual muscle during asymmetric shoulder lifting. Psychophysical workload was measured to observe the difference from MVC or biomechanical estimation. An apparatus was constructed for the study and twenty five trials including five flexion angles and five add/abduction angles were performed isometrically. Results indicated that MVC at 30 degree of flexion was the strongest whereas MVC at 120 degree was the weakest. In case of add/abduction, MVC decreased to 77 to 89 % during add/abduction compared to the MVC at neutral position. Regarding the normalized EMG value, a substantial increase was observed at 30 and 60 degree abduction. More importantly, the shoulder moment computed from maximum permissible limit (MPL) was greater than the moment at MVC condition during 30 degree adduction. Current result can be used as a reference information for a safe workplace design to prevent the shoulder from an excessive work load in industry.

  • PDF

Artificial neural network reconstructs core power distribution

  • Li, Wenhuai;Ding, Peng;Xia, Wenqing;Chen, Shu;Yu, Fengwan;Duan, Chengjie;Cui, Dawei;Chen, Chen
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.617-626
    • /
    • 2022
  • To effectively monitor the variety of distributions of neutron flux, fuel power or temperatures in the reactor core, usually the ex-core and in-core neutron detectors are employed. The thermocouples for temperature measurement are installed in the coolant inlet or outlet of the respective fuel assemblies. It is necessary to reconstruct the measurement information of the whole reactor position. However, the reading of different types of detector in the core reflects different aspects of the 3D power distribution. The feasibility of reconstruction the core three-dimension power distribution by using different combinations of in-core, ex-core and thermocouples detectors is analyzed in this paper to synthesize the useful information of various detectors. A comparison of multilayer perceptron (MLP) network and radial basis function (RBF) network is performed. RBF results are more extreme precision but also more sensitivity to detector failure and uncertainty, compare to MLP networks. This is because that localized neural network could offer conservative regression in RBF. Adding random disturbance in training dataset is helpful to reduce the influence of detector failure and uncertainty. Some convolution neural networks seem to be helpful to get more accurate results by use more spatial layout information, though relative researches are still under way.