• 제목/요약/키워드: 2D flow model

검색결과 1,112건 처리시간 0.038초

산불에 의한 열적상승유동 해석에 관한 연구 (A Study on the Model of Thermal Plume Flow in the Forest Fire)

  • 박준상;지영무;전향식;전대근
    • 한국유체기계학회 논문집
    • /
    • 제12권1호
    • /
    • pp.7-15
    • /
    • 2009
  • A study is made of thermal plume flow model for the development of helicopter simulator over the forest fire. For the numerical analysis, a line fire model with Boussinesq fluid approximation, which is idealized by the spreading shape of forest fire on the ground, is adopted. Comparing full 2-D and 3-D numerical solutions with 2-D similarity solution, it has been built a new model that is useful for temperature prediction along the symmetric vertical axis of fire model for both cases of laminar and turbulent flow.

Impact of Bidirectional Interaction between Sewer and Surface flow on 2011 Urban Flooding in Sadang stream watershed, Korea

  • Pakdimanivong, Mary;Kim, Yeonsu;Jung, Kwansue;Li, Heng
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2015년도 학술발표회
    • /
    • pp.397-397
    • /
    • 2015
  • The frequency of urban floods is recently increased as a consequence of climate change and haphazard development in urban area. To mitigate and prevent the flood damage, we generally utilized a numerical model to investigate the causes and risk of urban flood. Contrary to general flood inundation model simulating only the surface flow, the model needs to consider flow of the sewer network system like SWMM and ILLUDAS. However, this kind of model can not consider the interaction between the surface flow and drainage network. Therefore, we tried to evaluate the impact of bidirectional interaction between sewer and surface flow in urban flooding analysis based on simulations using the quasi-interacted model and the interacted model. As a general quasi-interacted model, SWMM5 and FLUMEN are utilized to analyze the flow of drainage network and simulate the inundation area, respectively. Then, FLO-2D is introduced to consider the interaction between the surface flow and sewer system. The two method applied to the biggest flood event occurred in July 2011 in Sadang area, South Korea. Based on the comparison with observation data, we confirmed that the model considering the interaction the sewer network and surface flow, showed a good agreement than the quasi-interacted model.

  • PDF

Axisymmetric Swirling Flow Simulation of the Draft Tube Vortex in Francis Turbines at Partial Discharge

  • Susan-Resiga, Romeo;Muntean, Sebastian;Stein, Peter;Avellan, Francois
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권4호
    • /
    • pp.295-302
    • /
    • 2009
  • The flow in the draft tube cone of Francis turbines operated at partial discharge is a complex hydrodynamic phenomenon where an incoming steady axisymmetric swirling flow evolves into a three-dimensional unsteady flow field with precessing helical vortex (also called vortex rope) and associated pressure fluctuations. The paper addresses the following fundamental question: is it possible to compute the circumferentially averaged flow field induced by the precessing vortex rope by using an axisymmetric turbulent swirling flow model? In other words, instead of averaging the measured or computed 3D velocity and pressure fields we would like to solve directly the circumferentially averaged governing equations. As a result, one could use a 2D axi-symmetric model instead of the full 3D flow simulation, with huge savings in both computing time and resources. In order to answer this question we first compute the axisymmetric turbulent swirling flow using available solvers by introducing a stagnant region model (SRM), essentially enforcing a unidirectional circumferentially averaged meridian flow as suggested by the experimental data. Numerical results obtained with both models are compared against measured axial and circumferential velocity profiles, as well as for the vortex rope location. Although the circumferentially averaged flow field cannot capture the unsteadiness of the 3D flow, it can be reliably used for further stability analysis, as well as for assessing and optimizing various techniques to stabilize the swirling flow. In particular, the methodology presented and validated in this paper is particularly useful in optimizing the blade design in order to reduce the stagnant region extent, thus mitigating the vortex rope and expending the operating range for Francis turbines.

원형관 코팅장치에서 연소 입자의 응축성장에 미치는 2차원 열 및 물질전달의 영향 (Effects of Two-dimensional Heat and Mass Transports on Condensational Growth of Soot Particles in a Tubular Coater)

  • 박성훈
    • 한국입자에어로졸학회지
    • /
    • 제9권3호
    • /
    • pp.163-171
    • /
    • 2013
  • Soot particles emitted from combustion processes are often coated by non-absorbing organic materials, which enhance the global warming effect of soot particles. It is of importance to study the condensation characteristics of soot particles experimentally and theoretically to reduce the uncertainty of the climate impact of soot particles. In this study, the condensational growth of soot particles in a tubular coater was modeled by a one-dimensional (1D) plug flow model and a two-dimensional (2D) laminar flow model. The effects of 2D heat and mass transports on the predicted particle growth were investigated. The temperature and coating material vapor concentration distributions in radial direction, which the 1D model could not accounted for, affected substantially the particle growth in the coater. Under the simulated conditions, the differences between the temperatures and vapor concentrations near the wall and at the tube center were large. The neglect of these variations by the 1D model resulted in a large error in modeling the mass transfer and aerosol dynamics occurring in the coater. The 1D model predicted the average temperature and vapor concentration quite accurately but overestimated the average diameter of the growing particles considerably. At the outermost grid, at which condensation begins earliest due to the lowest temperature and saturation vapor concentration, condensing vapor was exhausted rapidly because of the competition between condensations on the wall and on the particle surface, decreasing the growth rate. At the center of the tube, on the other hand, the growth rate was low due to high temperature and saturation vapor concentration. The effects of Brownian diffusion and thermophoresis were not high enough to transport the coating material vapor quickly from the tube center to the wall. The 1D model based on perfect radial mixing could not take into account this phenomenon, resulting in a much higher growth rate than what the 2D model predicted. The result of this study indicates that contrary to a previous report for a thermodenuder, 2D heat and mass transports must be taken into account to model accurately the condensational particle growth in a coater.

수치모형을 이용한 댐 상류 및 여수로 수리현상 해석 (Analysis of Hydraulic Characteristics Upstream of Dam and in Spillway Using Numerical Models)

  • 김영한;오정선;서일원
    • 한국수자원학회논문집
    • /
    • 제36권5호
    • /
    • pp.761-776
    • /
    • 2003
  • 본 연구에서는 사류 및 부압이 발생하는 자유수면을 가진 댐 상류 및 여수로에서 물의 흐름의 동수역학적인 거동을 파악하기 위하여 수치모형을 적용하였다. 댐 건설시, 댐 상류에서의 유동을 알아보기 위하여 2차원 수치모형인 RMA2를 이용하였고, 접근부에서의 3차원적 흐름과 여수로, 방류관 등에서의 흐름분포를 평가하기 위하여 3차원 CFD 프로그램인 FLUENT를 사용하였다. 수치모의에서는 지형 및 구조물에 관한 세부인자들이 수치모형을 구성하는 데 사용되었다. 한탄강 댐에 적용한 2차원 수치모의 결과, 댐 상류부 여러 지점에서 최대 유속이 1 m/s에 이르는 와류가 발생하는 것을 확인할 수 있었다. 이는 2차원 수치모형이 댐 건설 후 상류하천의 2차원적 유황을 규명하는 데 유용하게 활용될 수 있음을 의미한다. 3차원 수치모의 결과, 수위와 방류조건에 따라서 댐 직상류의 3차원 접근 흐름의 변화가 발생하고 있으며, 여수로, 방류관, 배사관으로 배출되는 유속이 상이하게 나타나고 있음이 밝혀졌다. 댐 상류 100 m지점에서 댐 여수로 중심선에 대한 유속 분포 모의치를 수리모형실험에서의 측정치와 비교한 결과, 두 값이 비슷하게 나타났다. 본 연구 결과, 2, 3 차원 수치모형이 댐 상류부 및 여수로의 흐름을 해석하는 데 있어서 수리모형실험에서 쉽게 수행하기 어려운 다양한 조건을 모의함으로써 댐 설계 최적화에 기여할 수 있으리라 판단된다.

반도체 칩 테스트용 챔버 형상에 따른 유동 균일성에 대한 수치적 연구 (A Numerical Study on the Flow Uniformity according to Chamber Shapes Used for Test of the Semi-Conductor Chip)

  • 이대규;마상범;김성;김정열;강채동;김진혁
    • 한국수소및신에너지학회논문집
    • /
    • 제31권5호
    • /
    • pp.480-488
    • /
    • 2020
  • This study was conducted to improve the flow uniformity inside the chip tester through changing the flow path formation according to the inlet and outlet position of chamber. The internal flow and velocity distributions of the modified chamber models (Cases 1-3) were compared with the reference chamber model through three-dimensional Reynolds-averaged Navier-Stokes equations with k-ε turbulence model. The modified chamber models showed the superior flow uniformity characteristics compared to the reference chamber model. To investigate the flow uniformity in the chip tester, the standard deviation of the velocity was defined and compared. Through the internal flow analysis and assesment of the standard deviation, Case 2 among the test cases including the reference model showed the best flow uniformity generally.

농촌지역의 질산성질소 거동 해석을 위한 모델 개발 및 현장 적용 (Model Development for Analysis of Nitrate Leaching and Its Field Application in a Rural Area)

  • 석희준;전철민
    • 자원환경지질
    • /
    • 제42권6호
    • /
    • pp.561-574
    • /
    • 2009
  • 본 연구에서는 농업지역에서의 양수, 관개, 탈질작용을 고려한 불포화대 및 포화대 지하수 흐름 및 용질이동 모델인 VSFRT2D(Variably Saturated Flow and Reactive Transport model)를 개발하였다. VSFRT2D는 Richards equation을 지하수 흐름 지배방정식으로 이용하며, Thornthwaite 방법을 이용하여 강수가 일어나지 않을 때 지표면 증발산량 계산 절차를 포함하는 새로운 모델을 개발함으로써 기존의 불포화대 모델을 개선하였다. 또한 Monod kinetics에 기반한 생분해 기작을 네 개의 비선형 오염물 거동식과 세 종류의 미생물 거동식을 이용함으로서 탈질작용을 이 모델에 반영하였다. 개발된 모델을 질산성질소로 오염된 홍성 지역의 현장 관측 자료에 적용하였다. 본 연구에서는 강수, 양수, 증발산, 관개, 비료 투여 및 다양한 생분해 과정들이 지하수 흐름 및 오염물 거동에 미치는 효과들을 확인하기 위하여 각각의 과정을 개별적으로 나누어서 수치 모의한 후 각각의 결과를 상호 비교하였다. 수치 모의 결과 이 지역에서의 질산성 질소 농도 변화는 생분해에 의한 영향은 매우 미미하게 나타났다. 반면에 관개에 의한 양수, 강수, 질소 비료 시비에 의해서는 크게 영향을 받았다.

토석류 발생지역 지형자료 구축 및 FLO-2D 모델링 (Terrain Data Construction and FLO-2D Modeling of the Debris-Flow Occurrences Area)

  • 오채연;전계원
    • 한국방재안전학회논문집
    • /
    • 제12권4호
    • /
    • pp.53-61
    • /
    • 2019
  • 토석류의 발생은 산악지역에 위치한 도로나 주택가에 심각한 위험을 초래하며 많은 재산의 손실을 발생시킨다. 본 연구에서는 산악지역에서 발생한 토석류를 모의하기 위해 2개의 유역을 선정하고 공간자료를 구축하였다. 첫 번째 유역의 경우 지상 LiDAR를 활용하여 토석류 발생 구간을 스캔하고 지형 자료를 구축하였으며 두 번째 유역의 경우는 드론을 활용하여 유역의 퇴적부를 촬영하고 DSM(Digital surface model)을 생성하였다. 그리고 토석류 발생이 하류부에 미치는 영향을 분석하기 위해 2차원 상용 모델인 FLO-2D를 사용하여 토석류의 흐름 영역을 시뮬레이션하고 지상 LiDAR 및 드론 측정데이터의 퇴적부와 비교분석하였다.

산불에 의한 열적상승유동 해석에 관한 연구 (A Study on the model of Thermal Plume Flow in the Forest Fire)

  • 지영무;박준상
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.358-361
    • /
    • 2008
  • A study is made of thermal plume flow model for the development of helicopter simulator over the forest fire. For numerical analysis, the Boussinesq fluid approximation and line fire model, which is assumed by the shape of forest fire spreading, are adopted. Comparing 3-D full numerical solutions with 2-D similarity solution, it has been built a new model that is capable of temperature prediction along the symmetric vertical axis in both cases of laminar and turbulent flows.

  • PDF

1D-2D 통합 도시 침수 해석 모형을 이용한 침수 원인 분석에 관한 연구 (Simulation and analysis of urban inundation using the integrated 1D-2D urban flood model)

  • 이승수;노성진;장철희;이동섭
    • 한국수자원학회논문집
    • /
    • 제50권4호
    • /
    • pp.263-275
    • /
    • 2017
  • 고정확도의 도시침수 모의를 위해서는 물리적 개념에 기반한 통합적 수치해석이 필요하다. 본 연구에서는 Lee et al. (2015)이 개발한 1차원 하수관망, 2차원 범람 모형의 국내 적용성을 검토하고, 과거 도시 홍수 사상의 침수 원인 분석을 수행하였다. 본 모형은 이중배수 개념에 기반하여 멘홀 대신 집수구를 지표면과 하수관망 사이의 교환유량 산정 지점으로 이용하므로 보다 실제와 유사하게 침수 과정을 모의할 수 있을 뿐 아니라 지표면 범람 해석시 건물에 의한 차단 효과를 고려할 수 있다. 개발된 모형의 적용성은 서울 사당 유역에서 발생한 침수 사상에 대해서 재현 모의를 통해 검증하였다. 적용 결과, 본 연구에서 개발된 모형은 실제 침수 피해 영역을 실제와 유사하게 모의 하였을 뿐만 아니라 침수 원인을 보다 자세히 분석할 수 있는 장점을 보여주었다.