• 제목/요약/키워드: 2D array detector

검색결과 76건 처리시간 0.028초

INTRODUCTION OF NUC ALGORITHM IN ON-BOARD RELATIVE RADIOMERIC CALIBRATION OF KOMPSAT-2

  • Song, J.H.;Choi, M.J.;Seo, D.C.;Lee, D.H.;Lim, H.S.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.504-507
    • /
    • 2007
  • The KOMPSAT-2 satellite is a push-broom system with MSC (Multi Spectral Camera) which contains a panchromatic band and four multi-spectral bands covering the spectral range from 450nm to 900nm. The PAN band is composed of six CCD array with 2528 pixels. And the MS band has one CCD array with 3792 pixels. Raw imagery generated from a push-broom sensor contains vertical streaks caused by variability in detector response, variability in lens falloff, pixel area, output amplifiers and especially electrical gain and offset. Relative radiometric calibration is necessary to account for the detector-to-detector non-uniformity in this raw imagery. Non-uniformity correction (NUC) is that the process of performing on-board relative correction of gain and offset for each pixel to improve data compressibility and to reduce banding and streaking from aggregation or re-sampling in the imagery. A relative gain and offset are calculated for each detector using scenes from uniform target area such as a large desert, forest, sea. In the NUC of KOMPSAT-2, The NUC table for each pixel are divided as HF NUC (high frequency NUC) and LF NUC (low frequency NUC) to apply to few restricted facts in the operating system ofKOMPSAT-2. This work presents the algorithm and process of NUC table generation and shows the imagery to compare with and without calibration.

  • PDF

CCTV 카메라용 광학계 설계 (Optical System Design for CCTV Camera)

  • 이수천
    • 한국안광학회지
    • /
    • 제13권1호
    • /
    • pp.31-35
    • /
    • 2008
  • 목적: 본 논문은 CCTV 카메라용 렌즈 설계를 triplet형으로 광학 설계를 하였다. 방법: 초점거리를 56 mm, 유효경을 20 mm 그리고 화각을 $5^{\circ}$로 한 망원 렌즈 형태이고, 설계하고자 하는 카메라의 CCD array detector의 크기를 2/3인치로 하였다. 결과: 광학계의 성능은 ray-fan과 spot diagram 그리고 회절 광학적인 MTF를 계산하여 평가하였고, 파장은 Fraunhofer C, d 및 F-line에 대해 achromat 되었으며 MTF 값도 tangential과 sagittal MTF 모두 50 line pairs/mm의 공간 주파수에 70% 정도가 나왔다. 결론: triplet형으로 비교적 저가 보급형 감시용 목적 CCTV 카메라를 설계하였고 충분히 실용적이라 생각된다.

  • PDF

단일 급전부를 갖는 레이다 디텍터용 X, K 밴드 배열 안테나 (X, K-Band Patch Array Antenna Having One Port Feeding for Radar Detector)

  • 주현모;박병철;계영철;이정해
    • 한국전자파학회논문지
    • /
    • 제23권5호
    • /
    • pp.559-569
    • /
    • 2012
  • 본 논문에서는 단일 급전부를 갖는 레이다 디턱테용 X 밴드(10.525 GHz) $1{\times}2$ 배열 안테나와 K 밴드(24.15 GHz) $3{\times}6$ 배열 안테나를 제안한다. 제안된 배열 안테나의 왼편에는 X 밴드 배열 안테나가 있고 오른편에는 K 밴드 배열 안테나가 있다. 두 개의 배열 안테나는 하나의 전송 선로를 통해 급전이 되고, stub가 각 배열 안테나의 앞부분에 있다. 서로 다른 동작 주파수를 갖는 배열 안테나를 일반적인 T-junction을 이용하여 하나의 전송선로로 급전할 경우, 서로 영향을 주어 배열 안테나의 특성이 크게 바뀌게 된다. 이러한 영향을 차단하기 위해 open, short 특성을 이용하여 stub를 설계하였다. 먼저 각 배열 안테나에 stub가 연결되어도 안테나 특성이 바뀌지 않는 것을 확인하였고, 최종적으로 두 개의 배열 안테나를 연결하여 하나의 전송 선로로 급전을 하여도 성능이 바뀌지 않는 것을 확인하였다. 측정한 이득은 X 밴드에서 6.47 dBi, K 밴드에서 13.07 dBi로 시뮬레이션 결과와 잘 일치하였다.

Mechanical design of mounts for IGRINS focal plane array

  • Oh, Jae Sok;Park, Chan;Cha, Sang-Mok;Yuk, In-Soo;Park, Kwijong;Kim, Kang-Min;Chun, Moo-Young;Ko, Kyeongyeon;Oh, Heeyoung;Jeong, Ueejeong;Nah, Jakyuong;Lee, Hanshin;Pavel, Michael;Jaffe, Daniel T.
    • 천문학회보
    • /
    • 제39권1호
    • /
    • pp.53.2-53.2
    • /
    • 2014
  • IGRINS, the Immersion GRating INfrared Spectrometer, is a near-infrared wide-band high-resolution spectrograph jointly developed by the Korea Astronomy and Space Science Institute and the University of Texas at Austin. IGRINS employs three HAWAII-2RG focal plane array (FPA) detectors. The mechanical mounts for these detectors serves a critical function in the overall instrument design: Optically, they permit the only positional compensation in the otherwise "build to print" design. Thermally, they permit setting and control of the detector operating temperature independently of the cryostat bench. We present the design and fabrication of the mechanical mount as a single module. The detector mount includes the array housing, a housing for the SIDECAR ASIC, a field flattener lens holder, and a support base. The detector and ASIC housing will be kept at 65 K and the support base at 130 K. G10 supports thermally isolate the detector and ASIC housing from the support base. The field flattening lens holder attaches directly to the FPA array housing and holds the lens with a six-point kinematic mount. Fine adjustment features permit changes in axial position and in yaw and pitch angles. We optimized the structural stability and thermal characteristics of the mount design using computer-aided 3D modeling and finite element analysis. Based on the computer simulation, the designed detector mount meets the optical and thermal requirements very well.

  • PDF

3차원 위상배열 레이다용 다기능 2채널 수신기 설계 및 제작 (Design and Implementation of Multifunction 2-Channel Receiver for 3 Dimensional Phased Array Radar)

  • 강승민;양진모;송재원
    • 전자공학회논문지D
    • /
    • 제35D권9호
    • /
    • pp.1-12
    • /
    • 1998
  • 표적의 방위각과 거리, 고도 정보를 실시간으로 검출하는 3차원 위상 배열 레이다용 수신기를 제작하였다. 이는 수신기 보호 기능과 감도를 제어하는 초고주파수부와 중간주파수부, 모노펄스 검출기, IQ 위상 검출기, 자동이득 제어부, 수신장치 제어기 등으로 구성되었으며, 동일 표적에 의해 반사된 두 반향 신호의 진폭을 비교하여 고도각 정보의 정확성을 높이기 위해 같은 기능의 2채널 수신기를 구현하였다. 수신기의 TSS 감도는 -98dBm, 수신기의 대역폭은 500MHz, 수신기 전체 이득은 최대 100dB까지 제어가능하며(AGC off시 수동으로), 두 채널간 이득 불균형은 최대 5dB이며, 위상 불균형은 최대 30°이다. 위상 검출기의 이미지 억제율은 평균 30dB이다. 수신기는 패키지 형태의 부품을 고유전율 기판에 실장하여 구현하였다.

  • PDF

이동 물체의 3차원 계측을 위한 PSD 센서 배열 설계 (PSD sensor array design for the 3D measurement of moving objects)

  • 김종만;도용태
    • 센서학회지
    • /
    • 제17권2호
    • /
    • pp.106-113
    • /
    • 2008
  • Perceiving a 3D moving target is important for automated machines including robots in a factory. Although stereovision or ultrasonic ranging is often employed for the purpose, the former requires high-cost systems, and the latter suffers from low-resolution. In this paper, we propose a PSD sensor array to acquire the 3D profile of an object conveyed by a belt. Rectangular parallelepiped target objects at random positions and orientations are assumed. Nine PSD sensors are configured in a $3{\times}3$ array above the belt, and fired in a sequence so that cross-talk can be avoided. Time gaps among sensor readings are compensated to get a result that is obtainable when sensors' measurements are made simultaneously along a sensing line. The system designed is tested with various objects in experiments.

혼 배열 안테나를 이용한 밀리미터파 수동 이미징 센서 연구 (Study Of Millimeter-Wave Passive Imaging Sensor Using the Horn Array Antenna)

  • 임현준;채연식;김미라;이진구
    • 대한전자공학회논문지TC
    • /
    • 제47권2호
    • /
    • pp.74-79
    • /
    • 2010
  • 본 연구에서는 다수의 혼 안테나 배열을 가지는 밀리미터파 수동 이미징 센서를 설계 하였다. 6개의 혼 안테나를 일체형 구조 형태로한 배열 안테나를 제안하였고, 이를 공간상에 효율적으로 배치함으로써, WR-10 구조의 LNA와의 결합이 용이하도록 하였다. 안테나는 94GHz의 중심주파수에서 17.5dBi의 최대 이득을 가지고, W 주파수 대역에서 -25dB 이하의 반사계수 값을 가지도록 설계 하였고, 고해상도의 안테나 배열을 위해 안테나 개구면을 $6mm{\times}9mm$의 작은 크기로 설계하였다. LNA는 양호한 성능의 수신감도를 얻기 위해 55dB 이상의 총 이득과, 5dB 이내의 잡음지수를 가지도록 설계 하였다. 밀리미터 신호를 직류 신호로 변환하기 위해 상용 제로 바이어스 쇼키 다이오드를 사용한 검파기를 제작하였고, 검파기의 성능을 측정한 결과 500mV/mW 이상의 양호한 수신감도를 얻었다.

HPLC/DAD/ESI-MS 및 고체상 추출법을 이용한 뇨시료중 갑상선 호르몬 분석 (Determination of thyroid hormones by solid-phase extraction using high performance liquid chromatograph/diode array detector/electro-spray ionization mass spectrometry in urine samples)

  • 곽선영;문명희;표희수
    • 분석과학
    • /
    • 제19권6호
    • /
    • pp.519-528
    • /
    • 2006
  • 본 연구에서는 뇨시료를 고체상 추출법으로 추출한 후 HPLC/DAD/ESI-MS(high-performance liquid chromatograph/diode array detector/electro-spray ionitation mass spectrometry)를 사용하여 분석하였다. 7종의 thyroid hormones의 HPLC 분리조건은 Hypersil ODS(octadecylsilica) 컬럼(4.6mm I.D., 100 mm length, particle size $5{\mu}m$)을 사용하고 ammonium formate buffer와 acetonitrile을 이동상으로 하여 기울기 용리한 결과 완전 분리가 가능하였으며, UV spectra 및 질량스펙트럼을 확인할 수 있었다. 고체상 추출법에 의한 전처리 최적 조건을 조사한 결과 시료를 pH 3으로 한 후 C18 고체상을 사용하여 4 mL의 methanol/ammonium hydroxide(9:1) 혼합용액으로 용리할 경우 회수율이 89.0-113.1%로 나타났다. HPLC/DAD를 이용하여 10-1000 ng/mL범위에서 검량선을 작성한 결과 $r^2$값은 0.992-0.998 으로 나타났으며 검출한계는 2-4 ng/mL(3.8-13.0 pmol/mL)로 계산되었다.

대면적 X-ray 검출기를 위한 분할 구동 시스템 (Seperate Driving System For Large Area X-ray Detector In Radiology)

  • 이동길;박지군;김대환;남상희;안상호;박효덕
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.388-391
    • /
    • 2003
  • The properties of these detectors can be controlled by electronics and exposure conditions. Flat-panel detectors for digital diagnostic imaging convert incident x-ray images to charge images. Flat panel detectors gain more interest real time medical x-ray imaging. Active area of flat panel detector is $14{\times}17$ inch. Detector is based on a $2560{\times}3072$ away of photoconductor and TFT pixels. X-ray conversion layer is deposited upper TFT array flat panel with a 500m by thermal deposition technology. Thickness uniformity of this layer is made of thickness control technology(5%) of thermal deposition system. Each $139m{\times}139m$ pixel is made of thin film transistor technology, a storage capacitor and charge collection electrode having geometrical fill factor of 86%. Using the separate driving system of two dimensional mosaic modules for large area, that is able to 4.2 second per frame. Imaging performance is suited for digital radiography imaging substitute by conventional radiography film system..

  • PDF

Test of a Multilayer Dose-Verification Gaseous Detector with Raster-Scan-Mode Proton Beams

  • Lee, Kyong Sei;Ahn, Sung Hwan;Han, Youngyih;Hong, Byungsik;Kim, Sang Yeol;Park, Sung Keun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제4권5호
    • /
    • pp.297-304
    • /
    • 2015
  • A multilayer gaseous detector has been developed for fast dose-verification measurements of raster-scan-mode therapeutic beams in particle therapy. The detector, which was constructed with eight thin parallel-plate ionization chambers (PPICs) and polymethyl methacrylate (PMMA) absorber plates, is closely tissue-equivalent in a beam's eye view. The gas-electron signals, collected on the strips and pad arrays of each PPIC, were amplified and processed with a continuous charge.integration mode. The detector was tested with 190-MeV raster-scan-mode beams that were provided by the Proton Therapy Facility at Samsung Medical Center, Seoul, South Korea. The detector responses of the PPICs for a 190-MeV raster-scan-mode proton beam agreed well with the dose data, measured using a 2D ionization chamber array (Octavius model, PTW). Furthermore, in this study it was confirmed that the detector simultaneously tracked the doses induced at the PPICs by the fast-oscillating beam, with a scanning speed of 2 m s-1. Thus, it is anticipated that the present detector, composed of thin PPICs and operating in charge.integration mode, will allow medical scientists to perform reliable fast dose-verification measurements for typical dynamic mode therapeutic beams.