• Title/Summary/Keyword: 2D 영상

Search Result 3,274, Processing Time 0.037 seconds

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF

Results of Three-Dimensional Conformal Radiation Therapy for the Treatment of a Solitary Sternal Relapse of Breast Cancer (흉골에 단독 전이된 유방암의 삼차원 입체조형 방사선 치료 성적)

  • Kim, Hae-Young;Huh, Seung-Jae;Park, Won;Choi, Do-Ho;Kang, Min-Kyu;Yang, Jung-Hyun;Nam, Seok-Jin;Im, Young-Hyuck
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.91-95
    • /
    • 2008
  • Purpose: To evaluate the response and survival rate after three-dimensional conformal radiation therapy(3D-CRT) of patients with a solitary sternal relapse of breast cancer. Materials and Methods: Seventeen patients between May 1996 and June 2005 were evaluated with the salvage 3D-CRT treatment of a solitary sternal relapse of breast cancer. The treatment fields included the gross tumor volume with 2 cm margins. The total radiation dose was $35.0{\sim}61.5$ Gy(biologic effective dose of $43.7{\sim}76.9Gy_{10}$ using an $\alpha/\beta$ ratio of 10 Gy), with a daily dose of $1.8{\sim}3.0$ Gy. The tumor response was evaluated by the change in maximum tumor size via follow up CT scans $1{\sim}3$ months after the completion of treatment. Results: An objective tumor response was achieved in all patients, with a complete response in 5 patients and a partial response in 12 patients. The 5-year overall survival rate was 51.9%(median survival time: 27 months), and the most important factor affecting overall survival was the disease-free interval(interval from primary surgery of breast cancer to the development of sternal metastasis): The 5-year overall survival rate was 61.8% for patients with a disease-free interval ${\geq}12$ months and 0.0% for patients with disease-free interval <12 months(p=0.03). Conclusion: The response to 3D-CRT was good in patients with solitary sternal relapse of breast cancer. Particularly, patients with long disease-free interval from primary surgery survived significantly longer than patients with short disease-free interval from primary surgery.

A study of Development of Transmission Systems for Terrestrial Single Channel Fixed 4K UHD & Mobile HD Convergence Broadcasting by Employing FEF (Future Extension Frame) Multiplexing Technique (FEF (Future Extension Frame) 다중화 기법을 이용한 지상파 단일 채널 고정 4K UHD & 이동 HD 융합방송 전송시스템 개발에 관한 연구)

  • Oh, JongGyu;Won, YongJu;Lee, JinSeop;Kim, JoonTae
    • Journal of Broadcast Engineering
    • /
    • v.20 no.2
    • /
    • pp.310-339
    • /
    • 2015
  • In this paper, the possibility of a terrestrial fixed 4K UHD (Ultra High Definition) and mobile HD (High Definition) convergence broadcasting service through a single channel employing the FEF (Future Extension Frame) multiplexing technique in DVB (Digital Video Broadcasting)-T2 (Second Generation Terrestrial) systems is examined. The performance of such a service is also investigated. FEF multiplexing technology can be used to adjust the FFT (fast Fourier transform) and CP (cyclic prefix) size for each layer, whereas M-PLP (Multiple-Physical Layer Pipe) multiplexing technology in DVB-T2 systems cannot. The convergence broadcasting service scenario, which can provide fixed 4K UHD and mobile HD broadcasting through a single terrestrial channel, is described, and transmission requirements of the SHVC (Scalable High Efficiency Video Coding) technique are predicted. A convergence broadcasting transmission system structure is described by employing FEF and transmission technologies in DVB-T2 systems. Optimized transmission parameters are drawn to transmit 4K UHD and HD convergence broadcasting by employing a convergence broadcasting transmission structure, and the reception performance of the optimized transmission parameters under AWGN (additive white Gaussian noise), static Brazil-D, and time-varying TU (Typical Urban)-6 channels is examined using computer simulations to find the TOV (threshold of visibility). From the results, for the 6 and 8 MHz bandwidths, reliable reception of both fixed 4K UHD and mobile HD layer data can be achieved under a static fixed and very fast fading multipath channel.

Prediction of Prognosis to Concurrent Chemo-Radiotherapy by Standardized Uptake Value of $2-[18^F]$ Fluovo-2-Deoxy-D-Glucose for Nasopharyngeal Carcinomas (비인강암 환자의 예후에서 $2-[18^F]$ Fluoro-2-Deoxy-D-Glucose PET 영상에서 계산되는 Standardized Uptake Value의 의의)

  • Lee Sang-wook;Im Ki Chun;Nam Soon Yuhl;Kim Jae Seung;Choi Eun Kyung;Ahn Seung Do;Shin Seong Soo;Ryu Jin Sook;Kim Sang Yoon;Lee Bong-Jae;Choi Seung-Ho;Kim Sung-Bae;Moon Dae Hyuk
    • Radiation Oncology Journal
    • /
    • v.23 no.1
    • /
    • pp.9-16
    • /
    • 2005
  • Purpose : To prospectively evaluate the use of positron emission tomography with the glucose analog fluoro-deoxyglucose (FDG-PET) to deoxyglucose (FDG-PET) to predict disease-free survival (DFS) after concurrent chemo-radiotherapy (CCRT) in patients with non-disseminated nasopharyngeal carcinoma (NPC). Materials and Methods : We studied 41 patients with non-disseminated NPC scheduled to undergo platinum-based CCRT were eligible for this study. Patients were studied by FDG-PET prior to the CCRT. FDG uptake of tumors were measured with the maximal standardized uptake value (SUV). Results : Complete response rate was $100\%$. In ten patients who presented with any component of treatment failure, the median $SUV_{max}$ was 8.55 (range: $2.49\~14.81$) in any component of failure and the median $SUV_{max}$ was 5.48 (range: $2.31\~26.07$) In the remaining patients without any such failure. Patients having tumors with high FDG uptake had a significantly lower 3-year DFS ($51\%\;{\nu}91\%$, p=0.0070) compared with patients having low uptake tumors. Conclusion : FDG uptake, as measured by the SUV, has potential value in predicting DFS in NPC treated by CCRT, High FDG uptake may be a useful parameter for Identifying patients requiring more aggressive treatment approaches.

Assessment of Bone Metastasis using Nuclear Medicine Imaging in Breast Cancer : Comparison between PET/CT and Bone Scan (유방암 환자에서 골전이에 대한 핵의학적 평가)

  • Cho, Dae-Hyoun;Ahn, Byeong-Cheol;Kang, Sung-Min;Seo, Ji-Hyoung;Bae, Jin-Ho;Lee, Sang-Woo;Jeong, Jin-Hyang;Yoo, Jeong-Soo;Park, Ho-Young;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.1
    • /
    • pp.30-41
    • /
    • 2007
  • Purpose: Bone metastasis in breast cancer patients are usually assessed by conventional Tc-99m methylene diphosphonate whole-body bone scan, which has a high sensitivity but a poor specificity. However, positron emission tomography with $^{18}F-2-deoxyglucose$ (FDG-PET) can offer superior spatial resolution and improved specificity. FDG-PET/CT can offer more information to assess bone metastasis than PET alone, by giving a anatomical information of non-enhanced CT image. We attempted to evaluate the usefulness of FDG-PET/CT for detecting bone metastasis in breast cancer and to compare FDG-PET/CT results with bone scan findings. Materials and Methods: The study group comprised 157 women patients (range: $28{\sim}78$ years old, $mean{\pm}SD=49.5{\pm}8.5$) with biopsy-proven breast cancer who underwent bone scan and FDG-PET/CT within 1 week interval. The final diagnosis of bone metastasis was established by histopathological findings, radiological correlation, or clinical follow-up. Bone scan was acquired over 4 hours after administration of 740 MBq Tc-99m MDP. Bone scan image was interpreted as normal, low, intermediate or high probability for osseous metastasis. FDG PET/CT was performed after 6 hours fasting. 370 MBq F-18 FDG was administered intravenously 1 hour before imaging. PET data was obtained by 3D mode and CT data, used as transmission correction database, was acquired during shallow respiration. PET images were evaluated by visual interpretation, and quantification of FDG accumulation in bone lesion was performed by maximal SUV(SUVmax) and relative SUV(SUVrel). Results: Six patients(4.4%) showed metastatic bone lesions. Four(66.6%) of 6 patients with osseous metastasis was detected by bone scan and all 6 patients(100%) were detected by PET/CT. A total of 135 bone lesions found on either FDG-PET or bone scan were consist of 108 osseous metastatic lesion and 27 benign bone lesions. Osseous metastatic lesion had higher SUVmax and SUVrel compared to benign bone lesion($4.79{\pm}3.32$ vs $1.45{\pm}0.44$, p=0.000, $3.08{\pm}2.85$ vs $0.30{\pm}0.43$, p=0.000). Among 108 osseous metastatic lesions, 76 lesions showed as abnormal uptake on bone scan, and 76 lesions also showed as increased FDG uptake on PET/CT scan. There was good agreement between FDG uptake and abnormal bone scan finding (Kendall tau-b : 0.689, p=0.000). Lesion showed increased bone tracer uptake had higher SUVmax and SUVrel compared to lesion showed no abnormal bone scan finding ($6.03{\pm}3.12$ vs $1.09{\pm}1.49$, p=0.000, $4.76{\pm}3.31$ vs $1.29{\pm}0.92$, p=0.000). The order of frequency of osseous metastatic site was vertebra, pelvis, rib, skull, sternum, scapula, femur, clavicle, and humerus. Metastatic lesion on skull had highest SUVmax and metastatic lesion on rib had highest SUVrel. Osteosclerotic metastatic lesion had lowest SUVmax and SUVrel. Conclusion: These results suggest that FDG-PET/CT is more sensitive to detect breast cancer patients with osseous metastasis. CT scan must be reviewed cautiously skeleton with bone window, because osteosclerotic metastatic lesion did not showed abnormal FDG accumulation frequently.

Analysis on the association between EEG and 2-deoxy-2-[18F]-D-glucose (FDG)-PET findings in children with epilepsy (소아 간질 환아에서 뇌파와 PET과의 연관성에 대한 분석)

  • Hur, Yun Jung;Lee, Joon Soo;Lee, Jong Doo;Kim, Heung Dong
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.3
    • /
    • pp.286-292
    • /
    • 2008
  • Purpose : We performed EEG and PET on children with epilepsy concomitantly in order to evaluate the effects of epileptiform and non-epileptiform discharge of EEG on glucose metabolism. Methods : Seventy three children with epilepsy who had PET and EEG simultaneously were included in our study. The subjects were classified in two ways: (1) based on the frequency of epileptiform discharge and (2) the severity of non-epileptiform discharge. We evaluated the clinical aspects of their seizures, the severity of focal slow waves during the interictal period with the frequency of spikes or sharp waves in order to compare with the PET results. Results : The subjects were divided by the frequency of epileptiform discharge, with 13 in the no/rare group, 7 in the occasional group, and 53 children in the frequent group. The concordant rates with PET in each group were 0%, 42.9%, and 67.9%, respectively, showing high correlations with the frequency of epileptiform discharge (P<0.05, r=0.491). The subjects as divided by the severity of non-epileptiform discharge were 15 in the no group, 25 in the infrequent group, 17 in the intermediate group, and 16 in the continuous group. The concurrence rates with PET for each group were 13.3%, 52.0%, 64.7%, and 68.8%, respectively, also showing a high correlation with the severity of non-epileptiform discharge (P<0.05, r= 0.365). Conclusion : Epileptiform discharge and non-epileptiform discharge in EEG showed a certain association with hypometabolism in PET. We recommend EEG to reduce false lateralization and to localize lesions in cases of high frequency and severity.

THE EFFECTS OF DIETARY CONSISTENCY ON THE TRABECULAR BONE ARCHITECTURE IN GROWING MOUSE MANDIBULAR CONDYLE : A STUDY USING MICRO-CONFUTED TOMOGRAPHY (성장 중인 쥐에서 음식물의 경도가 하악 과두의 해면골에 미치는 영향 : 미세전산화 단층촬영을 이용한 연구)

  • Youn, Seok-Hee;Lee, Sang-Dae;Kim, Jung-Wook;Lee, Sang-Hoon;Hahn, Se-Hyun;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.228-235
    • /
    • 2004
  • The development and proliferation of the mandibular condyle can be altered by changes in the biomechanical environment of the temporomandibular joint. The biomechanical loads were varied by feeding diets of different consistencies. The purpose of the present study was to determine whether changes of masticatory forces by feeding a soft diet can alter the trabecular bone morphology of the growing mouse mandibular condyle, by means of micro-computed tomography. Thirty-six female, 21 days old, C57BL/6 mice were randomly divided into two groups. Mice in the hard-diet control group were fed standard hard rodent pellets for 8 weeks. The soft-diet group mice were given soft ground diets for 8 weeks and their lower incisors were shortened by cutting with a wire cutter twice a week to reduce incision. After 8 weeks all animals were killed after they were weighed. Following sacrifice, the right mandibular condyle was removed. High spatial resolution tomography was done with a Skyscan Micro-CT 1072. Cross-sections were scanned and three-dimensional images were reconstructed from 2D sections. Morphometric and nonmetric parameters such as bone volume(BV), bone surface(BS), total volume(TV), bone volume fraction(BV/TV), surface to volume ratio(BS/BV), trabecular thickness(Tb. Th.), structure model index(SMI) and degree of anisotropy(DA) were directly determined by means of the software package at the micro-CT system. From directly determined indices the trabecular number(Tb. N.) and trabecular separation(Tb. Sp.) were calculated according to parallel plate model of Parfitt et al.. After micro-tomographic imaging, the samples were decalcified, dehydrated, embedded and sectioned for histological observation. The results were as follow: 1. The bone volume fraction, trabecular thickness(Tb. Th.) and trabecular number(Tb. N.) were significantly decreased in the soft-diet group compared with that of the control group (p<0.05). 2. The trabecular separation(Tb. Sp.) was significantly increased in the soft-diet group(p<0.05). 3. There was no significant differences in the surface to volume ratio(BS/BV), structure model index(SMI) and degree of anisotropy(DA) between the soft-diet group and hard-diet control group (p>0.05). 4. Histological sections showed that the thickness of the proliferative layer and total cartilage thickness were significantly reduced in the soft-diet group.

  • PDF

Estimation of Rice Canopy Height Using Terrestrial Laser Scanner (레이저 스캐너를 이용한 벼 군락 초장 추정)

  • Dongwon Kwon;Wan-Gyu Sang;Sungyul Chang;Woo-jin Im;Hyeok-jin Bak;Ji-hyeon Lee;Jung-Il Cho
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.25 no.4
    • /
    • pp.387-397
    • /
    • 2023
  • Plant height is a growth parameter that provides visible insights into the plant's growth status and has a high correlation with yield, so it is widely used in crop breeding and cultivation research. Investigation of the growth characteristics of crops such as plant height has generally been conducted directly by humans using a ruler, but with the recent development of sensing and image analysis technology, research is being attempted to digitally convert growth measurement technology to efficiently investigate crop growth. In this study, the canopy height of rice grown at various nitrogen fertilization levels was measured using a laser scanner capable of precise measurement over a wide range, and a comparative analysis was performed with the actual plant height. As a result of comparing the point cloud data collected with a laser scanner and the actual plant height, it was confirmed that the estimated plant height measured based on the average height of the top 1% points showed the highest correlation with the actual plant height (R2 = 0.93, RMSE = 2.73). Based on this, a linear regression equation was derived and used to convert the canopy height measured with a laser scanner to the actual plant height. The rice growth curve drawn by combining the actual and estimated plant height collected by various nitrogen fertilization conditions and growth period shows that the laser scanner-based canopy height measurement technology can be effectively utilized for assessing the plant height and growth of rice. In the future, 3D images derived from laser scanners are expected to be applicable to crop biomass estimation, plant shape analysis, etc., and can be used as a technology for digital conversion of conventional crop growth assessment methods.

Effects of Radiation Dose and Image Quality at the Coronary Angiography (관상동맥검사에서 선량과 화질에 관한 연구)

  • Ryu, Myung-Song;Choi, Nam-Gil;Han, Jae-Bok;Yang, Sook;Lee, Jong-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.4
    • /
    • pp.367-372
    • /
    • 2012
  • The aim of this study was to assess the effect of exposure factors such as kVp and mA applied by BMI on the image quality and patients absorbed dose of Coronary angiography in CT. Each data sets were into 4groups with different exposure values : Group A at 100kVp, 240mAs, Group B at 120kVp, 240mAs, Group C at 100kVp, 270mAs and Group D at 120kVp, 270mAs, and the mean of the scores of 4 groups was calculated for image quality as 4grades that is, 1(poor), 2(fair), 3(good) and 4(very good). Patient absorbed dose was calculated as DLP on the monitor. In case of absorbed dose, deviation in 2groups at 100kVp was 5.6 $mGy{\cdot}cm$, 11 $mGy{\cdot}cm$, was at 120kVp(DLP) with p<0.05. There was rather difference between groups with 100kVp or 120kVp respectively but the gaps were very little. No significant correlation was found between exposure factors and image quality in any images assessed(p>0.05), and the image quality was sufficient for diagnosis. As we applying coronary angiography, the selection of adequate exposure factors considering BMI identified might be effective for reduction of patient absorbed dose, improvement of image quality and diagnostic accuracy.

ERUPTION PATTERN OF THE MANDIBULAR FIRST MOLAR USING THE CONE BEAM CT (Cone Beam CT를 이용한 하악 제 1대구치 맹출 양상에 관한 연구)

  • Shin, Jeong-Keun;Kim, Jae-Gon;Baik, Byeong-Ju;Yang, Yeon-Mi;Jeong, Jin-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.3
    • /
    • pp.325-336
    • /
    • 2009
  • The purpose of this study was to investigate the eruption pattern of the mandibular first molar in sagittal, frontal and horizontal views using the cone beam CT scanning. CT images were obtained from healthy 83 children (42 boys, 41 girls) between 3 to 10 years of age with a normal dentition according to Nolla stage. 1. In the frontal and horizontal view, the intermolar width decreased continuously with stage and slightly increased at the last stage. 2. In the sagittal and frontal view, eruption distances from occlusal plane were observed the largest change between stage 5 and 7. 3. In the horizontal and sagittal view, mandibular first molar from distal surface of primary second molar moved distally between stage 4 and 6. 4. In the sagittal view, angle from occlusal plane to mesio-distal axis increased between stage 4 and 8. 5. In the frontal view, angle from occlusal plane to bucco-lingual axis increased continuously during all stage. 6. In the horizontal view, angle from midsagittal plane to long axis increased between stage 5 and 8.

  • PDF