• Title/Summary/Keyword: 2D/3D imaging

Search Result 854, Processing Time 0.039 seconds

Evaluation of Clinical Effectiveness of 3D Digital Endoscopic Image (3차원 디지탈 내시경 영상의 임상적 효용성 평가)

  • Song, Chul-Gyu;Kim, Kyeong-Seop;Kim, Nam-Gyun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.5 no.1
    • /
    • pp.26-31
    • /
    • 2002
  • This paper represents the design of 3D endoscopic video system in order to improve visualization and enhance the ability of the surgeon to perform delicate endoscopic surgery. Minimally invasive techniques have set new standards in all surgical may experience less post-operative discomfort, shorter hospitalization, and quicker recuperation. Finally, the aim of the present study was to determine the influence of 2D and 3D video imaging on defined tasks on a laparoscopic trainer.

  • PDF

A Study on 2D-3D Image Conversion using Depth Map Chart Analysis (깊이정보 지도 분석을 통한 2D-3D 영상 변환 연구)

  • Kim, In-Su;Kim, Hyung-Taek;Youn, Joo-Sang;Oh, Se-Woong;Seo, in-Seok;Kim, Nam-Gyu
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2015.01a
    • /
    • pp.205-208
    • /
    • 2015
  • 3D 입체영상을 제작하기 위해서는 2D 영상제작에 비해 오랜 제작 기간과 많은 비용이 발생한다. 비용 절감을 위해 기존의 2D 영상을 3D 입체영상으로 변환하는 연구가 진행되고 있다. 2D 영상을 3D 입체영상으로 변환하는 방식은 자동변환방법과 수동변환방법으로 구분할 수 있으며, 고품질의 2D-3D 변환 영상을 획득하기 위해서는 깊이정보 지도(Depth map chart)를 활용한 수동변환 방법을 많이 사용되고 있다. 하지만 2D-3D 수동변환에 사용되는 깊이정보 지도의 정량적 분석 데이터가 부족하여 사용자가 변환한 이미지에 대한 정확한 기준 깊이값 설정이 어려운 단점이 있다. 본 논문에서는 깊이정보 지도의 깊이값 정보에 대한 정량적 분석 데이터를 바탕으로 한 2D-3D 수동변환 변화범위를 제시함으로써 적정한 영상 변화를 유도할 수 있도록 한다.

  • PDF

Three-Dimensional Map System Using Integral Imaging Technique (집적 영상 기술을 이용한 3차원 지도 시스템)

  • Cho, Myungjin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.11
    • /
    • pp.2799-2804
    • /
    • 2014
  • In this paper, we suggest three-dimensional information extraction map system using integral imaging technique. Integral imaging can record multiple elemental images with different perspectives using a 2D image acquisition device with lenslet array. Using these images, integral imaging can obtain 3D information and display 3D image. In this paper, the position difference between elemental images can be obtained using summation of absolute difference (SAD), and then 3D information can be extracted. Therefore, this technique can find the height information of 3D objects.

Comparison of Contrast-Enhanced T2 FLAIR and 3D T1 Black-Blood Fast Spin-Echo for Detection of Leptomeningeal Metastases

  • Park, Yae Won;Ahn, Sung Jun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.2
    • /
    • pp.86-93
    • /
    • 2018
  • Purpose: Imaging plays a significant role in diagnosing leptomeningeal metastases. However, the most appropriate sequence for the detection of leptomeningeal metastases has yet to be determined. This study compares the efficacies of contrast-enhanced T2 fluid attenuated inversion recovery (FLAIR) and contrast-enhanced 3D T1 black-blood fast spin echo (FSE) imaging for the detection of leptomeningeal metastases. Materials and Methods: Tube phantoms containing varying concentrations of gadobutrol solution were scanned using T2 FLAIR and 3D T1 black-blood FSE. Additionally, 30 patients with leptomeningeal metastases were retrospectively evaluated to compare conspicuous lesions and the extent of leptomeningeal metastases detected by T2 FLAIR and 3D T1 black-blood FSE. Results: The signal intensities of low-concentration gadobutrol solutions (< 0.5 mmol/L) on T2 FLAIR images were higher than in 3D T1 black-blood FSE. The T2 FLAIR sequences exhibited significantly greater visual conspicuity scores than the 3D T1 black-blood sequence in leptomeningeal metastases of the pial membrane of cistern (P = 0.014). T2 FLAIR images exhibited a greater or equal extent (96.7%) of leptomeningeal metastases than 3D T1 black-blood FSE images. Conclusion: Because of its high sensitivity even at low gadolinium concentrations, contrast-enhanced T2 FLAIR images delineated leptomeningeal metastases in a wider territory than 3D T1 black-blood FSE.

3D Gaze Estimation and Interaction Technique (3차원 시선 추출 및 상호작용 기법)

  • Ki, Jeong-Seok;Jeon, Kyeong-Won;Kim, Sung-Kyu;Sohn, Kwang-Hoon;Kwon, Yong-Moo
    • Journal of Broadcast Engineering
    • /
    • v.11 no.4 s.33
    • /
    • pp.431-440
    • /
    • 2006
  • There are several researches on 2D gaze tracking techniques for the 2D screen for the Human-Computer Interaction. However, the researches for the gaze-based interaction to the stereo images or contents are not reported. The 3D display techniques are emerging now for the reality service. Moreover, the 3D interaction techniques are much more needed in the 3D contents service environments. This paper addresses gaze-based 3D interaction techniques on stereo display, such as parallax barrier or lenticular stereo display. This paper presents our researches on 3D gaze estimation and gaze-based interaction to stereo display.

Diagnosis of Rotator Cuff Tears with Non-Arthrographic MR Imaging: 3D Fat-Suppressed Isotropic Intermediate-Weighted Turbo Spin-Echo Sequence versus Conventional 2D Sequences at 3T

  • Hong, Won Sun;Jee, Won-Hee;Lee, So-Yeon;Chun, Chang-Woo;Jung, Joon-Yong;Kim, Yang-Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.4
    • /
    • pp.229-239
    • /
    • 2018
  • Purpose: To assess the diagnostic performance in detecting rotator cuff tears at 3T of non-arthrographic shoulder magnetic resonance imaging (MRI) using 3D isotropic turbo spin-echo (TSE-SPACE) sequence as compared with 2D sequences. Materials and Methods: Seventy-four patients who were arthroscopically confirmed to have underwent non-arthrographic shoulder MRI with 2D sequences and TSE-SPACE were included. Three independent readers retrospectively scored supraspinatus and infraspinatus tendon (SST-IST) and subscapularis tendon (SCT) tears on 2D sequences and TSE-SPACE. Results: The mean sensitivity, specificity, and accuracy of the three readers were 95%, 100%, and 95% on TSE-SPACE and 99%, 93%, and 98% on 2D sequences for detecting SST-IST tears, respectively, whereas those were 87%, 49%, and 68% on TSESPACE and 88%, 66%, and 77% on 2D sequences for detecting SCT tears, respectively. There was no statistical difference between the two sequences, except for in the specificity of one reader for detecting SCT tears. The mean AUCs of the three readers on TSE-SPACE and 2D sequences were 0.96 and 0.98 for detecting SST-IST tears, respectively, which were not significantly different, while those were 0.71 and 0.82 for detecting SCT tears, respectively, which were significantly different (P < 0.05). Conclusion: TSE-SPACE may have accuracy and reliability comparable to conventional 2D sequences for SST-IST tears at non-arthrographic 3T shoulder MRI, whereas TSE-SPACE was less reliable than conventional 2D sequences for detecting SCT tears.

Computational generation method of elemental images using a Kinect sensor in 3D depth-priority integral imaging (3D 깊이우선 집적영상 디스플레이에서의 키넥트 센서를 이용한 컴퓨터적인 요소영상 생성방법)

  • Ryu, Tae-Kyung;Oh, Yongseok;Jeong, Shin-Il
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.1
    • /
    • pp.167-174
    • /
    • 2016
  • In this paper, we propose a generation of 2D elemental images for 3D objects using Kinect in 3D depth-priority integral imaging (DPII) display. First, we analyze a principle to pickup elemental images based on ray optics. Based on our analysis, elemental images are generated with both RGB image and depth image recorded from Kinect. We reconstruct 3D images from the elemental images with the computational integral imaging reconstruction technique and then compare various perspective images. To show the usefulness of the proposed method, we carried out the preliminary experiments. The experimental results reveal that our method can provide correct 3D images with full parallax.

3D Integral Imaging Display using Axially Recorded Multiple Images

  • Cho, Myungjin;Shin, Donghak
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.5
    • /
    • pp.410-414
    • /
    • 2013
  • In this paper, we propose a 3D display method combining a pickup process using axially recorded multiple images and an integral imaging display process. First, we extract the color and depth information of 3D objects for displaying 3D images from axially recorded multiple 2D images. Next, using the extracted depth map and color images, elemental images are computationally synthesized based on a ray mapping model between 3D space and an elemental image plane. Finally, we display 3D images optically by an integral imaging system with a lenslet array. To show the usefulness of the proposed system, we carry out optical experiments for 3D objects and present the experimental results.

Real-Time 3-D Ultrasound Imaging Method using a 2-D Curved Array (이차원 곡면 어레이를 이용한 실시간 3차원 초음파 영상화 기법)

  • 김강식;한호산;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.351-364
    • /
    • 2002
  • Conventional 3D ultrasound imaging using mechanical ID arrays suffers from poor elevation resolution due to the limited depth-of-focus (DOF). On the other hand, 3D imaging systems using 2D phased arrays have a large number of active channels and hence require a very expensive and bulky beamforming hardware. To overcome these limitations, a new real-time volumetric imaging method using curved 2-D arrays is presented, in which a small subaperture, consisting of 256 elements, moves across the array surface to scan a volume of interest. For this purpose, a 2-D curved array is designed which consists of 90$\times$46 elements with 1.5λ inter-element spacing and has the same view angles along both the lateral and elevation directions as those of a commercial mechanical 1-D array. In the proposed method, transmit and receive subapertures are constructed by cutting the four corners of a rectangular aperture to obtain a required image qualify with a small number of active channels. In addition the receive subaperture size is increased by using a sparse array scheme that uses every other elements in both directions. To suppress the grating lobes elevated due to the increase in clement spacing, fold-over array scheme is adopted in transmit, which doubles the effective size of a transmit aperture in each direction. Computer simulation results show that the proposed method can provide almost the same and greatly improved resolutions in the lateral and elevation directions, respectively compared with the conventional 3D imaging with a mechanical 1-D array.

An improved 2D/3D convertible integral imaging with two parallel display devices

  • Choi, Hee-Jin;Park, Jae-Hyeung;Kim, Joo-Hwan;Cho, Seong-Woo;Lee, Byoung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.46-49
    • /
    • 2005
  • In this paper, a novel 2D/3D convertible display system based on integral imaging is proposed. Combining two liquid crystal display panels with integral imaging, it is possible to convert the display between two-dimensional mode and three-dimensional mode without mechanical movement. The proposed method is proven by preliminary experiments.

  • PDF