• Title/Summary/Keyword: 2D/2D matching

Search Result 1,025, Processing Time 0.035 seconds

Evaluation of Usability Both Oblique Verification for Inserted Fiducial Marker of Prostate Cancer Patients (Fiducial Marker가 삽입된 전립선암 환자를 대상으로 한 양사방향 촬영의 유용성 평가)

  • Kim, Koon Joo;Lee, Jung Jin;Kim, Sung Gi;Lim, Hyun Sil;Kim, Wan Sun;Kang, Su Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • Purpose: The way check the movement of the fiducial marker insertion in the treatment of patients with prostate cancer. However the existing methods of fiducial marker verification process difficult to identify the specific location of the marker behind the femur and pelvic bone. So to study the evaluation of maker match with using kilo voltage (KV) X-ray by On-board imager to both oblique verification method. Materials and Methods: Five patients were selected for rectal ballooning and inserted fiducial marker. Compare the position of the fiducial marker of reference plan 2D/2D Anterior/Posterior verification method and 2D/2D both oblique verification method. So to measurement the shift score of X, Y, Z (axis) and measure exposure dose given to patients and compare matching time. Results: 2 dimensional OBI KV X-ray imaging using two-dimensional matching image are orthogonal, so locating fiducial marker matching clear and useful DRR (digital reconstruction radiography) OBI souce angle ($45^{\circ}/315^{\circ}$) matching most useful. 2D/2D both oblique verification method was able to see clearly marker behind the pelvic bone. Also matching time can be reduced accordingly. According to the method of each matching results for each patient in each treatment fraction, X, Y, and Z axis the Mean $value{\pm}SD$ (standard deviation) is X axis (AP/LAT: $0.4{\pm}1.67$, OBLIQUE: $0.4{\pm}1.82$) mm, Y axis (AP/LAT: $0.7{\pm}1.73$, OBLIQUE: $0.2{\pm}1.77$) mm, Z axis (AP/LAT: $0.8{\pm}1.94$, OBLIQUE:$1.5{\pm}2.8$) mm. In addition, the KV X-ray source dose radiation exposure given to the patient taking average when AP/LAT matching is (0.1/2.1) cGY, when $315^{\circ}/45^{\circ}$ matching is (0.27/0.26) cGY. Conclusion: In conclusion for inserted fiducial marker of prostate cancer patients 2D/2D both oblique matching method is more accurate verification than 2D/2D AP/LAT matching method. Also the matching time less than the 2D/2D AP/LAT matching method. Taken as the amount of radiation exposure to patients less than was possible. Suggest would improve the treatment quality of care patients more useful to establish a protocol such as case.

  • PDF

Design of a Dual-Mode Planar Antenna Using a Reconfigurable Matching Network (재구성 정합 회로를 이용한 평판형 이중 모드 안테나 설계)

  • Kim, Yoon Geon;Kay, Youngchul;Choo, Hosung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.12
    • /
    • pp.1337-1342
    • /
    • 2012
  • In this paper, we propose a novel reconfigurable antenna that can change the electrical shape of the matching network using RF switches of PIN diodes. The designed antenna operates at two different modes that are Mode 1 (HSDPA band, 2.1~2.2 GHz) and Mode 2(WiBro WiFi band, 2.3~2.5 GHz). The antenna is built on both sides of a polyarcylate substrate. The measured reflection coefficient shows a matching bandwidth of 547 MHz($S_{11}$ <-3 dB, 2.035~2.582 GHz) for Mode 1 and 600 MHz($S_{11}$ <-3 dB, 2.2~2.8 GHz) for Mode 2, and it shows average vertical gains of -4.4 dBi and -4.5 dBi in x-y plane, respectively.

Analysis of Uncertainties due to Digitally Reconstructed Radiographic (DRR) Image Quality in 2D-2D Matching between DRRs and kV X-ray Images from the On-Board Imager (OBI) (디지털 재구성 방사선영상과 온보드 영상장치를 이용한 2D-2D 정합 시 디지털 재구성 방사선영상의 질이 정합 정확도에 미치는 영향 분석)

  • Cheong Kwang-Ho;Cho Byung-Chul;Kaug Sei-Kwon;Kim Kyoung-Joo;Bae Hoon-Sik;Suh Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.67-76
    • /
    • 2006
  • We evaluated the accuracy of a patient setup error correction due to reference image quality for a 2D-2D matching process. Digitally reconstructed radiographs (DRRs) generated by use of the Pinnacle3 and the Eclipse for various regions of a humanoid phantom and a patient for different CT slice thickness were employed as a reference images and kV X-ray Images from the On-Board Imager were registered to the reference DRRs. In comparison of the DRRs and profiles, DRR image quality was getting worse with an increase of CT image slice thickness. However there were only slight differences of setup errors evaluation between matching results for good and poor reference DRRs. Although DRR image quality did not strongly affect to the 2D-2D matching accuracy, there are still potential errors for matching procedure, therefore we recommend that DRR images are needed to be generated with less than 3mm slice thickness for 2D-2D matching.

  • PDF

A Geocoding Method Implemented for Hierarchical Areal Addressing System in Korea

  • Lee, Ji-Yeong;Kim, Hag-Yeol
    • Spatial Information Research
    • /
    • v.14 no.4 s.39
    • /
    • pp.403-419
    • /
    • 2006
  • The well-blown address matching technology developed by the U.S. Census Bureau was applicable only for street addresses. However, many other addressing systems on the basis of a hierarchy of areas (hierarchical areal addressing system), such as Korean or Japanese addressing system, cannot be suitable for the existing address matching method. This paper, therefore, develops an areal address matching method, especially for Korean addressing system, in order to geocode 2D and 3D locational data of human activities. Thus, this study explains a new approach to dealing with 3D positioning method composed of two geocoding methods, which are a '2D Korean Address Matching' technique and a '3D Address Matching' technique.

  • PDF

Design of MMIC power amplifier using double tuned matching (Double tuned matching에 의한 MMIC 광대역 전력 증폭기의 설계)

  • 김진성;채연식;윤용순;이진구
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2000.11a
    • /
    • pp.150-153
    • /
    • 2000
  • In this paper, we have designed a 2 stage MMIC power amplifier which has flat gains of in-band and reasonable out-band cutoff characteristics using 0.5$\mu\textrm{m}$ MESFET libra교 of ETRI. For the 1st stave, we obtaind P$_{1dB}$ of 9.2 dBm and gain 10.8 dB using 6 finger D-MESFET and P$_{1dB}$ of 18.4 dBm and gain of 10.8 dB using 14 finger D-MESFET for the 2nd stage, which is power matched using LIBRA's embedded TUNER. Also in-band gain flatness and out-band cutoff characteristics are obtained by attaching LC tank in the output matching circuit. The designed 2 stage MMIC power amplifier has bandwidth of 0.95~2.8 GHz, gain of 20 dB and P$_{1dB}$of 17.2 dBm. Especially gain flatness of $\pm$0.8dB was obtained in 1.8~2.5 GHz frequency ranges. And chip size is 1.4$\times$1.4 mm..4 mm.

  • PDF

Automated 2D/3D Image Matching Technique with Dual X-ray Images for Estimation of 3D In Vivo Knee Kinematics

  • Kim, Yoon-Hyuk;Phong, Le Dinh;Kim, Kyung-Soo;Kim, Tae-Seong
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.6
    • /
    • pp.431-435
    • /
    • 2008
  • Quantitative information of a three dimensional(3D) kinematics of joint is very useful in knee joint surgery, understanding how knee kinematics related to joint injury, impairment, surgical treatment, and rehabilitation. In this paper, an automated 2D/3D image matching technique was developed to estimate the 3D in vivo knee kinematics using dual X-ray images. First, a 3D geometric model of the knee was reconstructed from CT scan data. The 3D in vivo position and orientation of femoral and tibial components of the knee joint could be estimated by minimizing the pixel by pixel difference between the projection images from the developed 3D model and the given X-ray images. The accuracy of the developed technique was validated by an experiment with a cubic phantom. The present 2D/3D image matching technique for the estimation of in vivo joint kinematics could be useful for pre-operative planning as well as post-operative evaluation of knee surgery.

The Estimation of the Transform Parameters Using the Pattern Matching with 2D Images (2차원 영상에서 패턴매칭을 이용한 3차원 물체의 변환정보 추정)

  • 조택동;이호영;양상민
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.7
    • /
    • pp.83-91
    • /
    • 2004
  • The determination of camera position and orientation from known correspondences of 3D reference points and their images is known as pose estimation in computer vision or space resection in photogrammetry. This paper discusses estimation of transform parameters using the pattern matching method with 2D images only. In general, the 3D reference points or lines are needed to find out the 3D transform parameters, but this method is applied without the 3D reference points or lines. It uses only two images to find out the transform parameters between two image. The algorithm is simulated using Visual C++ on Windows 98.

E-Band Bond-Wire Modeling and Matching Network Design (E-대역 본드와이어 모델링 및 정합회로 설계)

  • Kim, Kimok;Kang, Hyunuk;Lee, Wooseok;Choi, Doohun;Yang, Youngoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.6
    • /
    • pp.401-406
    • /
    • 2018
  • In this paper, we present E-band bond-wire modeling and a matching network to compensate for the effect of the bond-wire. The impedance of the bond-wires is extracted using three-dimensional electromagnetic simulation. The matching network was designed using a simple structure. The implemented matching network was verified with a commercial 71~81 GHz LNA IC and an interconnection based on the WR-12 waveguide. The matching network increases the transmission coefficient of the system by up to 4.5 dB, power gain by up to 3.12 dB, $P_{1dB}$ by up to 2.2 dB, and improves the gain flatness by ${\pm}1.07dB$.

Concurrent Dual-Band Class-E Power Amplifier Using a Multi-Harmonic Matching Network (Multi-Harmonic Matching Network을 이용한 동시-이중 대역 Class-E 전력 증폭기)

  • Park, Seung-Won;Jeon, Sanggeun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.4
    • /
    • pp.401-410
    • /
    • 2014
  • This paper presents a high-efficiency concurrent dual-band Class-E power amplifier(PA) that is based on a multi-harmonic matching network(MHMN). The proposed MHMN controls the impedance at 1.3 GHz, 2.1 GHz, and their second and third harmonics, respectively, by using transmission lines only rather than switches or lumped components. The dual-band Class-E PA is implemented using Avago ATF-50189 GaAs p-HEMT. The PA exhibits a measured output power of 27.1 dBm and 25.7 dBm, a power gain of 6.1 dB and 4.7 dB, and a drain efficiency of 71.2 % and 60.1 % at 1.3 GHz and 2.1 GHz, respectively.