Changes of Serotype Distribution of Streptococcus pneumoniae Isolated from Children in Korea over a 15 Year-period(1991~2005) (15년간(1991~2005년) 우리나라 소아에서 분리된 폐구균의 혈청형 분포의 변화)

  • Kim, So-Hee;Song, Eun-Kyung;Lee, Jun-Ho;Kim, Nam-Hee;Lee, Jin-A;Choi, Eun-Hwa;Lee, Hoan-Jong
    • Pediatric Infection and Vaccine
    • /
    • v.13 no.2
    • /
    • pp.89-98
    • /
    • 2006
  • Purpose : The prevalence of serotypes can be changed with respect to age of the patients, regions and times of the surveillance. The aim of this study is to analyze changes in serotype distribution of pneumococcal isolates from Korean pediatric patients. Methods : Four hundred and sixty five strains of S. pneumoniae were isolated from various clinical specimens at the Seoul National University Children's Hospital during a 15 year-period, from 1991 to 2005, were subjected to serotype and penicillin susceptibility. The study period was divided into three 5 year-periods, 1991~1995(period I), 1996~2000(period II), and 2001~2005(period III). Results : Common serotypes were 19F, 23F, 19A, 6B, 14, 6A and 9V in decreasing orders of frequency, and these 7 serotypes accounted for 79% of total 465 strains. In the serotype distribution of invasive infection isolates from children <60 months of age, similar serotypes accounted for 70% of 101 strains. In total strains, the proportion of serotype 19A and 6A increased, while that of serotype 19F and 14 decreased. The majority(75~92%) of vaccine types and cross-reactive types from invasive infection isolates was penicillin-resistant, whereas 34.4% of non-vaccine types was penicillin-resistant. Conclusion : Distribution of serotypes of S. pneuomoniae isolated from Korean children has changed significantly over the last 15 years. The surveillance for pneumococcal serotypes should be continued to monitor changes in serotype distribution which are essential for the establishment of pneumococcal vaccine policy.

  • PDF

Distribution of Resource Plants in the Wolmyung Park, Gunsan City (군산시 월명공원일대 자원식물의 분포 현황)

  • Oh, Hyun-Kyung;Kim, Young-Ha;Beon, Mu-Sup
    • Korean Journal of Plant Resources
    • /
    • v.20 no.2
    • /
    • pp.133-144
    • /
    • 2007
  • The vascular plants at the Wolmyung Park was listed 479 taxa: 105 families, 317 genera, 417 species, 1 subspecies, 55 varieties and 6 forms. 479 taxa listed consists of 291 taxa of edible plants (60.8%), 335 taxa of medicinal plants (69.9%), 234 taxa of ornamental plants (48.9%) and 243 taxa of the others (50.7%). Based on the list of the rare plants by the Forest Research Institute, 4 taxa were recorded in the investigated areas; Aristolochia contorta (Preservation priority order, No. 151), Magnolia kobus (No. 187), Prunus yedoensis (No. 110), Berchemia racemesa (No. 67) and based on the list of Korean endemic plants, 9 taxa were recorded; Cephalotaxus koreana, Carex okamotoi, Populus tomentiglandulosa, Prunus yedoensis, Forsythia koreana, Asperula lasiantha, Weigela subsessilis, Adenophora triphylla var. hirsuta, Aster koraiensis. Specific plant species by floral region were total 31 taxa; Prunus yedoensis, Berchemia racemosa in class V, Magnolia kobus, Wistaria floribunda in class IV, 4 taxa (Spiraea salicifolia, Acer palmatum, Asperula lasiantha, etc.) in class III, Caryopteris incana in class II, 22 taxa (Clematis patens, Orixa japonica, Euscaphis japonica, Grewia biloba var. parviflora, etc.) in class I. The naturalized plants in this site were 14 families, 35 genera, 44 species, 2 varieties, 46 taxa and naturalization rate was 9.6% of all 479 taxa vascular plants.

Antibiotic Resistance and Plasmid Profile of Vibrio parahaemolyticus Strains Isolated from Kyunggi-Incheon Coastal Area (경기인천 연안에서 분리된 장염비브리오균의 항생제 내성 및 플라스미드 보유 현황)

  • Han, A-Rheum;Yoon, Young-June;Kim, Jung-Wan
    • Korean Journal of Microbiology
    • /
    • v.48 no.1
    • /
    • pp.22-28
    • /
    • 2012
  • Vibrio parahaemolyticus is one of the major agents responsible for food poisoning during summer in Korea, which is transmitted via seawater or seafoods. Recently, distribution of the bacteria in the marine environment has been increased due to global warming. Great concern also has been raised regarding public hygiene as well as marine culture by the emergence of pathogens with antibiotic resistance. Therefore, distribution of V. parahaemolyticus and antibiotic resistance of the isolates were monitored in 7 coastal areas of Kyonggi Province and Incheon by sampling seawater, fishes and clams monthly. V. parahaemolyticus was detected from 47.7% of 966 samples (seawater 61.9%, seafoods 41.8%) analyzed using $CHROMagar^{TM}$ and TCBS agar plates as well as multiplex PCR. Among 13 antibiotics tested, resistance to vancomycin and ampicillin was observed in 97.3% and 87.3% of the isolates, respectively, and the ratios of them resistant to cephalothin (48.8%) and rifampin (46.1%) were also high. The isolates were most highly sensitive to chloramphenicol (91.7%) and trimethoprim-sulfamethoxazole (91.8%). The ratio of sensitivity for other antibiotics was also high in the descending order of gentamycin (82.3%), tobramycin (74.8%), nalidixic acid (71.6%), tetracyclin (69.4%), cefotaxime (63.0%). About 69% of the isolates showed multiple drug resistance toward 3 antibiotics including vancomycin and ampicillin. Two of them exhibited resistance for 11 antibiotics used in this study. Plasmid profile analysis of the isolates with antibiotic resistance revealed that 55.1% of them retained plasmids of 24 different types. However, no clear inter-relationship between the resistance and the plasmid profile has been observed.

HPF Application Test for PD Detection of XLPE Power Cable (XLPE 전력케이블의 부분방전 검출을 위한 HPF 적용 시험)

  • Kim, Jung-Yoon;Yang, Jong-Kyung;Park, Noh-Joon;Choi, Yong-Sung;Park, Dae-Hee;Lee, Yong-Sung
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.161-165
    • /
    • 2006
  • In this paper, we developed HPF (high pass filter) consists of lumped LC components to decrease the noises that are detected in PD (partial discharge) measuring test, and adapted it to field test. We tested it under laboratory circumstances like the fields, and measured the phase change properties of detected signal in UHF sensor with Lemke Probe and oscilloscope (TDS-3054, Tektronix). As a result, we obtained available data showing the decrease of noises in the experiments with the developed HPF from the joint box of 22.9kV distribution line. The result can be adapted to prevent the degeneration of the XLPE power cable, and to observe and diagnosis the underground power transmission cable at the ultra-high voltage.

Feature Extraction of Fault Current using Fourier Transform in the Multi-Shot Reclosing Scheme (푸리에 변환을 이용한 다중 재폐로방식에서의 사고전류 특징 추출)

  • O, Jeong-Hwan;Yun, Sang-Yun;Kim, Jae-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.2
    • /
    • pp.50-55
    • /
    • 2000
  • This paper presents the feature extraction of fault currents related to the multi-shot reclosing scheme in the power distribution system. In order to get the fault current waveform, we have measured the fault currents by the fault recorders which have been installed at the secondary side of 154/22.9[kV] substation transformer. These waveforms are classified into temporary and permanent fault. For the classified waveforms, Fourier transform is used to extract the feature of the fault current waveforms. After the waveforms are analyzed by using Fourier transform, the magnitude spectrum and the relative variation of THD (Total Harmonic Distortion) are calculated. And then the relative variation of THD is great in the temporary faults, and is small in the permanent faults.

  • PDF

Studies on Benzo(a)pyrene Content in the Surface Soil of Seoul City (서울市 土砂中 Benzo (a) pyrene의 含量에 關한 硏究)

  • 孫東憲;金載翰
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.5 no.2
    • /
    • pp.12-20
    • /
    • 1989
  • Distribution of benzo(a)pyrene (BaP) in Seoul surface soils was investigated with a simple micro-analytical method consisting of ultrasonic extraction, one-dimensional dual band thin-layer chromatographic separation (TLC) and spectrofluorometric determination. The TLC was done in the following condition: thin-layer plate; Kieselguhr G/Acetylated cellulose, Developer; 1st; ether, 2nd; methanol-ether-water (4:4:1, V/V). The results thus obtained were as follows; 1. All the samples collected from various areas were contained detectable amount of benzo(a)pyrene. The range and average of benzo(a)pyrene contents in Seoul areas are 0.20 $\sim$5.90ppm and 1.01 ppm, respectively. 2. Benzo(a)pyrene contents in soils obtained from commercial areas were much higher than those in industrial and residential areas. The contents range in commercial, industrial, and residential areas are 0.31 $\sim$ 5.90 ppm, 0.36 $\sim$ 1.22 ppm and 0.20 $\sim$ 0.67 ppm, respectively. 3. Benzo(a)pyrene contents in soils from major roads were far higher than those from side or park roads. The ranges of benzo(a)pyrene contents in major, park and side road are 0.40 $\sim$ 5.9 ppm, 0.20 $\sim$ 0.70 ppm, 0.31 $\sim$ 1.30 ppm, respectively. These findings suggest strongly that surface soils in Seoul city are polluted by benzo(a)pyrene probably emitted automobiles.

  • PDF

Clinical Pharmacokinetics of Vancomycin in Lymphoma Patients and Normal Volunteers (임파종환자에서 반코마이신의 임상약물동태)

  • Kim, Jae Ho;Choi, Jun Shik;Lee, Jin Hwan
    • Korean Journal of Clinical Pharmacy
    • /
    • v.9 no.2
    • /
    • pp.88-91
    • /
    • 1999
  • The purpose of this study was to compare the pkarmacokinetic parameters of vancomycin using a 2-compartment model in 8 Korean healthy volunteers and 8 lymphoma patients. Vancomycin (1.0 g) was administered by IV infusion over 60 minutes. The $\beta-phase$ rate constant $(\beta)$, apparent volume of distribution at steady srate $(V_{ss})$, total body clearance (CL) and area under the plasma level-time curve (AUC) of vancomycin in healthy volunteers were $0.15\pm0.02\;hr^{-1},\;33.8\pm4.12\;L/kg,\;5.36\pm0.61\;L/hr\;and\;185.8\pm20.5\;{\mu}g/ml{\cdot}hr$, respectively. The corresponding values in lymphoma patients ere $0.09\pm0.02\;hr^{-1},\;38.2\pm5.11\;L/kg,\;4.58\pm0.52\;L/hr\;and\;218.3\pm22.9\;{\mu}g/ml{\cdot}hr$. There were significant differences (p<0.05) in ${\beta}$ and CL between healthy volunteers and lymphoma patients.

  • PDF

Fabrication and Performance Evaluation of MR-16 Lamp Series with Narrow Angular Distribution of Luminous Intensity Using an Aspherical Planar-convex 2×2 Fly-eye Lens Type (평면-비구면 2×2 fly-eye 렌즈형태의 2차 렌즈를 사용한 고효율의 좁은 배광각을 갖는 MR-16 램프 시리즈 제작 및 성능평가)

  • Chu, Kyung-duk;Ryu, Jae Myung;Hong, Chun-Gang;Jeong, Youn Hong;Jo, Jae Heung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.8
    • /
    • pp.25-33
    • /
    • 2017
  • This paper reports the optical design of the MR-16 lamp series with a LED second lens and an aspherical plano-convex lens suitable for a simple and rapid injection molding fabrication method. The fabrication and performance evaluation of the MR-16 lamp series, which was designed with a narrow angular distribution of luminous intensity, were conducted to replace halogen lamps with LED lamps. Four types of LED lamps were fabricated, which have angular distributions of luminous intensity of $22.4^{\circ}$, $31.1^{\circ}$, $37.3^{\circ}$, and $59.9^{\circ}$ and luminous efficiencies of 76.5 lm/W, 75.2 lm/W, 72.0 lm/W, and 77.8 lm/W, respectively, while their spreading angles with an illuminance uniformity of 81% were $3^{\circ}$, $15^{\circ}$, $22^{\circ}$, and $49^{\circ}$, respectively. After eliminating a yellow tail of the LED lamps using a diffusion sheet, the angular distributions of the luminous intensity were measured to be $20.8^{\circ}$, $31.5^{\circ}$, $37.8^{\circ}$, and $68.7^{\circ}$.

A Study for the Improvement of the Fault Decision Capability of FRTU using Discrete Wavelet Transform and Neural Network (이산 웨이블릿 변환과 신경회로망을 이용한 FRTU의 고장판단 능력 개선에 관한 연구)

  • Hong, Dae-Seung;Ko, Yoon-Seok;Kang, Tae-Ku;Park, Hak-Yeol;Yim, Hwa-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1183-1190
    • /
    • 2007
  • This paper proposes the improved fault decision algorithm using DWT(Discrete Wavelet Transform) and ANNs for the FRTU(Feeder Remote Terminal Unit) on the feeder in the power distribution system. Generally, the FRTU has the fault decision scheme detecting the phase fault, the ground fault. Especially FRTU has the function for 2000ms. This function doesn't operate FI(Fault Indicator) for the Inrush current generated in switching time. But it has a defect making it impossible for the FI to be operated from the real fault current in inrush restraint time. In such a case, we can not find the fault zone from FI information. Accordingly, the improved fault recognition algorithm is needed to solve this problem. The DWT analysis gives the frequency and time-scale information. The neural network system as a fault recognition was trained to distinguish the inrush current from the fault status by a gradient descent method. In this paper, fault recognition algorithm is improved by using voltage monitoring system, DWT and neural network. All of the data were measured in actual 22.9kV power distribution system.

A Study on the Minimization of Tie-plate Loss of Cast Resin Transformer using Surface Impedance Boundary Condition (표면 임피던스 경계조건을 이용한 몰드변압기 Tie-plate 손실 최소화에 관한 연구)

  • Hwang, Sung-Ryul;Shin, Pan Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.9
    • /
    • pp.1334-1340
    • /
    • 2017
  • In this paper, a tie-plate shape is optimized by using the numerical technique to reduce the stray load loss of the tie-plate which is a mechanical structure for assembling and supporting of the transformer core. The eddy current loss of the structure is calculated by an electromagnetic field FEM program and the results are compared with 4 different shapes of tie-plates. Since the thickness of the tie-plate is very thin, and the skin depth is very small, the number of FE elements for 3-D transformer model is too big to solve. So, the surface impedance boundary condition (SIBC) is used to reduce the system matrix size and its computing time. To verify the method a 2.5 MVA 22,900/380V distribution transformer is simulated using one objective function and three design variables with some constraints. The final optimized tie-plate has three slots of 6 mm width and 23 mm gap, and the loss is reduced by 75 %. Consequently, the proposed algorithm seems to be considerably applicable to electric machinery as well as power transformer.