• Title/Summary/Keyword: 20MW/$m^2$

Search Result 78, Processing Time 0.024 seconds

Analysis of Smoke Control According to Jet Fan Location in Straight Long Tunnel (제트 팬 설치 위치에 따른 직선터널 내의 제연해석)

  • Byun, Ju-Suk;Lim, Hyo-Jae;Kang, Shin-Hyung;Lee, Jin-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.9
    • /
    • pp.662-668
    • /
    • 2007
  • In this study, jet fans are installed with 4 cases in the straight long tunnel; inlet-side setup, middle-side setup, outlet-side setup, and dispersion setup. A bus is selected as fired car, of which fire size is 20MW. And fired car locates at 100m, 700m, 1500m position from tunnel inlet, respectively. FLUENT, commercial finite-volume code, is used to analyze the performance. The velocity profile, $CO_2$ concentration, temperature distribution are examined for analysis. Performance of smoke control is compared by the backlayering length. Consequently, inlet-side setup of jet fans is a little more efficient than other cases considering the fire occurrence frequency in tunnel.

고온용융물과 콘크리트간의 반응(MCCI): MK1실험결과

  • Noh, Ki-Man;Kim, Jong-Hwan;Kim, Sang-Baek;Shin, Ki-Yeol;Jeong, Mo
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11a
    • /
    • pp.315-320
    • /
    • 1996
  • 원자력 발전소에서의 중대사고시, 고온의 노심 용융물이 원자로 공동으로 떨어지면 노심용융물과 콘크리트간의 반응(MCCI)에 의한 여러가지 현상으로 인해 격납용기의 건전성을 위협할 수 있다. 본 연구에서는 노심 용융물의 모사체로 고온의 Thermite 20kg을 영광 원자력 발전소 3, 4호기에 사용된 콘크리트 시편에 부어 중대사고시 MCCI 현상을 모사하였다. 실험에서는 국내 콘크리트에서의 침식율, 가스 및 입자 발생률을 측정하였다. 실험에서 측정된 용융물의 최고 온도는 약 2230 $^{\circ}C$이고, 콘크리트 시편으로의 최대 하부 열유속은 초기에 약 1.1~1.3 MW/$m^2$로 나타났으며, 전체적인 콘크리트의 침식 깊이는 약 15mm 그리고 초기의 최대 침식율은 129 cm/hr로 나타났다. 향후에 이 실험 결과를 MELCOR 코드의 MCCI 해석 모듈인 CORCON-MOD3의 해석 결과와 비교할 예정이다.

  • PDF

An Experimental Study of Smoke Movement in Tunnel Fires (터널화재시 연기 거동에 관한 실험적 연구)

  • Lee, Sung-Ryong;Kim, Choong-Ik;Ryou, Hong-Sun
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.121-126
    • /
    • 2001
  • In this study, reduced-scale experiments were conducted to understand smoke movements in tunnel fires with the natural ventilation. The 1/20 scale experiments were conducted under the Froude scaling since the smoke movement in tunnels is governed by buoyancy force. Six cases of experiments(pool diameter is 6.5cm, 7.3cm, 8.3cm, 10cm, l2.5cm and l5.4cm), in which vertical vents positioned 1m from the fire source symmetrically, were conducted in order to evaluate the effect of the vent on smoke movement. In case of heat release rate under 2MW, smoke front reached to the tunnel exit about 20 see delayed with ventilation and the smoke velocity was proportional to the power of the heat release rate. Temperature after the vent was lower than without vent. In case of l5.4cm pool, the temperature difference was about $50^{\circ}C$. It was confirmed that the thickness of smoke layer was maintained uniformly under the 35% height of tunnel through the visualized smoke flow by a laser sheet and the digital camcoder.

  • PDF

Effect of Polymer Additives on Drag Reduction for a Plate Type Heat Exchanger in OTEC Applications (고분자 첨가제에 의한 OTEC용 판형 열교환기의 마찰저항감소 효과 연구)

  • Kim, N.S.;Yoon, S.M.;Seo, T.B.;Kim, C.B.
    • Solar Energy
    • /
    • v.19 no.2
    • /
    • pp.37-44
    • /
    • 1999
  • Experimental investigation has been carried out to determine drag reducing effects of polymer additives for a plate type heat exchanger(evaporator or condenser) in OTEC power plant applications, where the pressure drop in the heat exchangers takes up $70{\sim}80%$ of the total pumping power in the existing system. The rate of drag reduction was investigated with various polymer concentrations and mass flow rates. Experiments were undertaken for a test section in Alfa-Laval plate heat exchanger utilizing Poly Ethylene Oxide(Mw $5{\times}10^6$) as polymer additives. Concentrations of polymer additives were 5, 10, 20, 30, 40, 50, 100, 200, 400 wppm at $25^{\circ}C$ and mass flow rates were 0.6kg/s, 0.7kg/s, 0.8kg/s and 0.9kg/s in normal operating ranges for a 15kW Alfa-Laval plate heat exchanger. The maximum effects of drag reductions were found at approximately 0.7kg/s of mass flow rate. The results show that there exists the optimum mass flow rate for the plate heat exchanger to obtain maximum drag reductions. Drag reduction of 20% means considerable savings in pumping power for a large size of OTEC plant.

  • PDF

Preparation of Dextran Microparticles by Using the SAS Process (초임계 반용매 재결정 공정을 이용한 Dextran 입자의 제조)

  • Kang, Dong-Yuk;Min, Byoung-Jun;Rho, Seon-Gyun;Kang, Choon-Hyoung
    • Korean Chemical Engineering Research
    • /
    • v.46 no.5
    • /
    • pp.958-964
    • /
    • 2008
  • In this work, micro-sized dextran particles, which have recently been focused as one of the candidate materials for the Drug Delivery System(DDS), were prepared by means of the Supercritical Antisolvent (SAS) process with $CO_2$. With dimethyl sulfoxide(DMSO) as the solvent, effects of the operating variables such as temperature (308.15~323.15 K), pressure(90~130 bar), solute concentration(10~20 mg/ml), and the molecular weight of the solute(Mw=37,500, 450,000) on the size and morphology of the resulting particles were thoroughly observed. The higher solute concentration led to the larger particles, however, the injection velocity of the solution and pressure did not show significant effects on the resulting particle size. With dextran of the lower molecular weight, the smallest particles were obtained at 313.15 K. On the other hand, the size of the particles from the high molecular weight dextran ranged between $0.1{\sim}0.5{\mu}m$ with an incremental effect of the temperature and pressure. For the solute concentration of 5 mg/ml, the lower molecular weight dextran did not form discrete particles while aggregation of the particles appeared when the solute concentration exceeded 15 mg/ml for the higher molecular weight dextran. It is believed that if the solute concentration is too low, the degree of the supersaturation in the recrystallization chamber would not be sufficient for initiation of the nucleation and growth mechanism. Instead, the spinodal decomposition mechanism leads to formation of the island-like phase separation which appears similar to aggregation of the discrete particles. This effect would be more pronounced for the smaller molecular weight polymer system due to the narrower phase-splitting region.

Manufacturing and testing of flat-type divertor mockup with advanced materials

  • Nanyu Mou;Xiyang Zhang;Qianqian Lin;Xianke Yang;Le Han;Lei Cao;Damao Yao
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2139-2146
    • /
    • 2023
  • During reactor operation, the divertor must withstand unprecedented simultaneous high heat fluxes and high-energy neutron irradiation. The extremely severe service environment of the divertor imposes a huge challenge to the bonding quality of divertor joints, i.e., the joints must withstand thermal, mechanical and neutron loads, as well as cyclic mode of operation. In this paper, potassium-doped tungsten (KW) is selected as the plasma facing material (PFM), oxygen-free copper (OFC) as the interlayer, oxide dispersion strengthened copper (ODS-Cu) alloy as the heat sink material, and reduced activation ferritic/martensitic (RAFM) steel as the structural material. In this study, a vacuum brazing technology is proposed and optimized to bond Cu and ODS-Cu alloy with the silver-free brazing material CuSnTi. The most appropriate brazing parameters are a brazing temperature of 940 ℃ and a holding time of 15 min. High-quality bonding interfaces have been successfully obtained by vacuum brazing technology, and the average shear strength of the as-obtained KW/Cu and ODS-Cu alloy joints is ~268 MPa. And a fabrication route for manufacturing the flat-type divertor target based on brazing technology is set. For evaluating the reliability of the fabrication technologies under the reactor relevant condition, the high heat flux test at 20 MW/m2 for the as-manufactured flat-type KW/Cu/ODS-Cu/RAFM mockup is carried out by using the Electron-beam Material testing Scenario (EMS-60) with water cooling. This paper reports the improved vacuum brazing technology to connect Cu to ODS-Cu alloy and summarizes the production route, high heat flux (HHF) test, the pre and post non-destructive examination, and the surface results of the flat-type KW/Cu/ODS-Cu/RAFM mockup after the HHF test. The test results demonstrate that the mockup manufactured according to the fabrication route still have structural and interfacial integrity under cyclic high heat loads.

Study on an open fuel cycle of IVG.1M research reactor operating with LEU-fuel

  • Ruslan А. Irkimbekov ;Artur S. Surayev ;Galina А. Vityuk ;Olzhas M. Zhanbolatov ;Zamanbek B. Kozhabaev;Sergey V. Bedenko ;Nima Ghal-Eh ;Alexander D. Vurim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1439-1447
    • /
    • 2023
  • The fuel cycle characteristics of the IVG.1M reactor were studied within the framework of the research reactor conversion program to modernize the IVG.1M reactor. Optimum use of the nuclear fuel and reactor was achieved through routine methods which included partial fuel reloading combined with scheduled maintenance operations. Since, the additional problem in planning the fuel cycle of the IVG.1M reactor was the poisoning of the beryllium parts of the core, reflector, and control system. An assessment of the residual power and composition of spent fuel is necessary for the selection and justification of the technology for its subsequent management. Computational studies were performed using the MCNP6.1 program and the neutronics model of the IVG.1M reactor. The proposed scheme of annual partial fuel reloading allows for maintaining a high reactor reactivity margin, stabilizing it within 2-4 βeff for 20 years, and achieving a burnup of 9.9-10.8 MW × day/kg U in the steady state mode of fuel reloading. Spent fuel immediately after unloading from the reactor can be placed in a transport packaging cask for shipping or safely stored in dry storage at the research reactor site.

Fabrication and optoelectrical properties for cdSSe photoconductive cell by using print/sintering (인쇄/소결 방법에 의한 CdSSe 광전도 셀 제작과 광전기적 특성)

  • Hong, Kwang-Joon;Lee, Sang-Youl
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04b
    • /
    • pp.46-50
    • /
    • 2004
  • 인쇄/소결 방법으로 가시영역에서 광감도가 매우 큰 CdSSe 다결정 후막을 만들고 이를 이용하여 광전도 젤을 제작하였다. 후막의 낱알 크기는 $5{\mu}m$ 정도이였다. 광전도 셀은 소결 촉진제로 첨가한 $cucl_2$ 양이 CdSSe 1 g 당 3.06~0.10 mg 정도이변 감도, 광전류와 암전류의 비율이 각각 0.7과 $10^5$ 이상을 나타내었고, Cds 와 CdSe 의 질량비가 1:0, 9:1, 8:2, 7:3, 6:4, 5:5일 때 응답파장은 각각 500nm, 520nm, 540nm, 570nm, 620nm, 660nm였다. 또한 주파수 특성을 나타내는 응답시간은 오름시간과 감쇠시간이 각각 30관 20ms 정도 이였으며 최대허용 소비 전력은 80mw 이상이었다. 이상과 같이 인쇄/소결 방법으로 제작된 광전도 셀은 $cucl_2$ 양이 CdSSe 1g 당 0.06~0.10 mg 정도 주입되면 센서로써 좋은 특성을 나타내었다.

  • PDF

Evaluation of Denitrification Efficiency and Functional Gene Change According to Carbon(Fumarate) Concentration and Addition of Nitrate Contaminated-soil in Batch System (회분식반응조 실험을 통한 탄소원(Fumarate) 주입조건에 따른 지하수 중 탈질율 및 탈질 관련 기능성 유전자 분석)

  • Park, Sunhwa;Kim, Hyun-Koo;Kim, Moon-su;Lee, Gyeong-Mi;Jeon, Sang-Ho;Song, Dahee;Kim, Deok-hyun;Kim, Young;Kim, Tae-seung
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.7
    • /
    • pp.80-89
    • /
    • 2015
  • Nitrate is on the most seriou pollutant encountered in shallow groundwater aquifer in agricultural area. There are various remediation technologies such as ion exchange, reverse osmosis, and biological denitrification to recover from nitrate contamination. Biological denitrification by indigenous microorganism of the technologies has been reviewed and applied on nitrate contaminated groundwater. In this work, we selected the site where the annual nitrate (NO3) concentration is over 105 mg/L and evaluated denitrification process with sampled soil and groundwater from 3 monitoring wells (MW4, 5, 6). In the results, the nitrate degradation rate in each well (MW 4, 5, and 6) was 25 NO3 mg/L/day, 6 NO3 mg/L/day, and 3.4 NO3 mg/L/day, respectively. Nitrate degradation rate was higher in batch system treated with 2 times higher fumarate as carbon source than control batch system (0.42M fumrate/1M NO3), comparing with batch system with soil sample. This result indicates that increase of carbon source is more efficient to enhance denitrification rate than addition of soil sample to increase microbial dynamics. In this work, we also confirmed that monitoring method of functional genes (nirK and nosZ) involved in denitrification process can be applied to evaluated denitrifcation process possibility before application of field process such as in-situ denitrification by push-pull test.

Hydrogenation of Methyl Dodecanoate Using Copper Chromite (분산액에서의 Copper Chromite 합성 및 Methyl Dodecanoate의 수소화반응)

  • Kang, Ho-Cheol;Lee, Sang-Hoon;Park, Jong-Mok;Kim, Dong-Pyo;Lee, Byung Min
    • Applied Chemistry for Engineering
    • /
    • v.20 no.2
    • /
    • pp.201-207
    • /
    • 2009
  • The hydrogenation reaction of methyl dodecanoate for the synthesis of 1-dodecanol has been carried out in the presence of a copper chromite catalyst. The catalysts were synthesized by ceramic method, co-precipitation, and improved co-precipitation method and the particles were characterized by SEM and XRD. Also, the products of the reaction were assigned by GC, GC/MSD and NMR. The particles synthesized by each method showed (1) a spherical shape with the size of 3.2 to $7.0{\mu}m$, (2) an agglomerated spherical shape with the size of 50 to 500 nm and (3) a spherical shape with smaller particle size, respectively. Especially, in order to control the size of particles, the particles were synthesized in various dispersant solutions as Span 80, polyacrylate, and polyethyleneglycols (PEGs). The particles synthesized in PEG (Mw = 4000) solution showed the smallest particle size of 30 to 50 nm and the regularity of the particle size distribution. Our experimental results elucidated that the activity of catalyst for hydrogenation increases with decreasing the size of catalyst particle. The highest yield of dodecanol in the hydrogenation reaction was 95.5% when copper chromite synthesized in the PEG solution was used as a catalyst in the optimized reaction condition.