• Title/Summary/Keyword: 20MW/$m^2$

Search Result 78, Processing Time 0.031 seconds

Variations of Geotechnical Characteristics Following Freeze-Thaw of Terra Nova Bay Rocks, Antarctica (남극 테라노바 만 편마암의 동결-융해에 따른 지반공학적 특성 변화)

  • Kim, YoungSeok;Kim, Kiju;Jang, Hyun-Shic;Jang, Bo-An
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1499-1508
    • /
    • 2013
  • Freeze-thaw tests were performed on gneiss samples collected from Terra Nova Bay, Antarctica in order to examine the engineering properties of rocks with slightly weathered (SW) and moderately weathered (MW). The tests were conducted under temperature ranging from $20{\pm}2^{\circ}C$ to $-20{\pm}2^{\circ}C$. A cycle of test consisted of 5 hours of freezing followed by another 5 hours of thawing under full saturation. In this paper, total 200 cycles of freeze-thaw test were performed with measurements of porosity, absorption, ultrasonic velocity, and shore hardness per each 20 cycle and that of uniaxial compressive strength (UCS) per each 50 cycle. The UCS of the SW rocks approximately decreased 0.07 MPa per a single cycle, while that of MW rocks decreased around 0.2 MPa per a single cycle. During the 200 cycles of SW rocks, the absorption increased from 0.23% to 0.39%, the P-wave velocity decreased from 4,054 m/s to 3,227 m/s and S-wave velocity decreased from 2,519 m/s to 2,079 m/s. Similarly, those of MW rocks changed from 0.65% to 1.6%, 3,207 m/s to 2,133 m/s and 2,028 m/s to 1,357 m/s. In conclusion, it was inferred that the properties of SW rocks experienced approximately 200-300 cycles of freeze-thaw process become close to those of MW rocks.

Immune Cell Stimulating Activity of Wheat Arabinoxylan (밀 arabinoxylan의 면역세포 활성화 작용)

  • Choi, Eun-Mi;Lim, Tae-Soo;Lee, Hye-Lim;Hwang, Jae-Kwan
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.3
    • /
    • pp.510-517
    • /
    • 2002
  • Effects of wheat arabinoxylan on mouse spleen lymphocytes and peritoneal macrophages were examined in vitro. Among three wheat arabinoxylans (A1: low MW, A2: medium MW, A3: high MW), A3$(50{\sim}100\;{\mu}g/mL)$ increased the viability of spleen lymphocytes up to $114{\sim}125%$ of the control. A1 and A3 $(20\;{\mu}g/mL)$ increased the viability of lipopolysaccharide-treated lymphocytes synergistically. Viability of murine peritoneal macrophages treated with wheat arabinoxylans $(10{\sim}100{\mu}g/mL)$ was increased up to $135{\sim}175%$ of the control. The cytotoxic activity of macrophages against murine lymphocytic leukemic cell increased in the presence of wheat arabinoxylan. Phagocytic index of macrophages treated with wheat arabinozylans $(20\;{\mu}g/mL)$ significantly increased $197{\sim}232%$ compared with the control, and lysosomal phosphatase and myeloperoxidase activities also increased significantly (p<0.05). Treatment of wheat arabinoxylans tended to decrease nitrite production, but significantly stimulated $H_2O_2\;and\;O_2$ productions of macrophages (p<0.05). These results indicate that the immunostimulating effect of wheat arabinoxylan may be closely related with lysosomal enzyme activity and reactive oxygen intermediate production of macrophages.

Integrated Photonic Channel Selective Microwave Bandpass Filter Incorporating a 1×2 Switch Based on Tunable Polymeric Ring Resonators (폴리머 링 공진기 기반의 스위치를 이용한 집적광학 채널 선택 마이크로웨이브 대역통과 필터)

  • Kim, Gun-Duk;Lee, Sang-Shin
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.1
    • /
    • pp.79-83
    • /
    • 2007
  • A reconfigurable photonic microwave (MW) channel selective filter was demonstrated incorporating a $1{\times}2$ switch based on two tunable polymeric resonators with different free spectral ranges. Each resonator, consisting of two cascaded rings with an electrode formed on one of them, plays a role as an on/off switch through the thermooptic effect. The optical signal carrying the MW signal is routed to either port of the switch and detected to show the filtered output at the frequency determined by the free spectral range of the corresponding resonator. When the channel centered at 10 GHz was chosen, the extinction ratio was ${\sim}30dB$, the bandwidth 1 GHz, and the electrical power consumption 4.1 mW. For the other channel located at 20 GHz, we have achieved the extinction ratio of ${\sim}30dB$, the bandwidth of 2 GHz, and the required power of 8.0 mW. Finally the crosstalk between the selected and blocked channels was higher than 24 dB.

A study on grid aspect ratio of fire dynamics simulator (FDS의 격자 종횡비에 관한 연구)

  • Kim, Won Ouk;Park, Woe-Chul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.9
    • /
    • pp.923-928
    • /
    • 2015
  • The FDS is one of the most used programs for fire analysis and needs an optimal grid selection for an accurate analysis. This study selected various grid aspect ratios (ARs) for selection of optimal grid and analyzed them with FDS v 6.1.2. A calculation time of 10 min. was used, which is enough to obtain the time average value of temperature changes. Temperature, visibility, and the time average value of mass balance are obtained from 200-600 s, which is a period of maintaining quasi-steady state. Two polyurethane fires of 1 [MW] and 2 [MW] in two enclosures of $10{\times}10{\times}3[m^3]$ and $20{\times}20{\times}3[m^3]$ were considered. Time variations of heat release rates, temperature, visibility, and mass balance were compared for ARs from 1-6. The heat release rates were accurate for all aspect ratios regardless of fire and enclosure sizes. The quasi-steady state temperature and visibility were well predicted for $AR{\leq}5$. Temperature drop and skewness of mass conservation, however, increased with increasing aspect ratio. Therefore, careful investigation of the grid size is recommended in performance-based design when $AR{\geq}3$, where temperature and visibility in early stage of a fire are important parameters. For accurate simulations of enclosure fires, grid sizes of 0.1~0.2 [m] and smaller in the vertical direction and $AR{\leq}2$ are recommended.

Studies on the Changes in Chemical Composition and Microbiological Aspects of Raw Milk by Microwave Heating (Microwave 열처리에 의한 원유의 화학적 및 미생물학적 성상의 변화에 관한 연구)

  • Shin, Byeong Hong;Kim, Jong Woo
    • Korean Journal of Agricultural Science
    • /
    • v.25 no.2
    • /
    • pp.181-198
    • /
    • 1998
  • In order to determine the optimum pasteurization conditions by microwave heating(MWH) at $50^{\circ}C{\sim}70^{\circ}C$ for 30 minute compared with water bath heating(WBH) at $65^{\circ}C$ for 30minute during storage at $5^{\circ}C$, the chemical composition, microbiological changes and keeping quality were examined and the results were as follows: 1. The fat protein lactose, total solid contents of raw milk, at $50{\sim}70^{\circ}C$ for 30 min. in MWH and at 65 for $30^{\circ}C$ min. in WBH did not changed significantly during the storage at $5^{\circ}C$. 2. The pH and acidity for the raw milk untreated were 6.75 and 0.16%, and those of MWH heated and WBH milk wee 6.75~6.50 and 0.16%~0.19%, phosphatase test were negative at $61^{\circ}C$ for 20 min. at $62^{\circ}C$ for 15 min. at $63^{\circ}C$ for 10 min. at $64^{\circ}C$ for 5 min. at $65^{\circ}C$ for 5 min. in MWH and at $65^{\circ}C$ for 30 min. in WBH. 3. Whey protein content was $18.53mg/m{\ell}$ in raw milk untreated, however, those were decreased as the heating temperature increased. The proteolytic activity of treated milk by WBH(44%) was lower than that by MWH(94%). 4. Total bacteria counts were $2.8{\times}10^5CFU/m{\ell}$ in raw milk untreated, $2.8{\times}10^3CFU/m{\ell}$ at $65^{\circ}C$ for 30 min. $2.4{\times}10^3CFU/m{\ell}$ at $70^{\circ}C$ for 30 min. in MWH and $3.0{\times}10^3CFU/m{\ell}$ at $65^{\circ}C$ for 30 min. in WBH. Because total bacteria count did not increased in MWH at $65^{\circ}C$, $70^{\circ}C$ for 30 min. and $65^{\circ}C$ for 30 min. in WBH during the 10 days storaging, Also, total bacteria counts for treated milk were a most drastic decrease after $61^{\circ}C$, $62^{\circ}C$, $63^{\circ}C$, $64^{\circ}C$, $65^{\circ}C$ for 5 min. in MWH. 5. Coliform bacteria counts were $2.6{\times}10^3CFU/m{\ell}$ in raw milk untreated. There were not detected at $55^{\circ}C{\sim}70^{\circ}C$ for 30 min. in MWH and at $65^{\circ}C$ for 30 min. in WBH. Coliform bacteria counts were not detected after $61^{\circ}C$, $62^{\circ}C$, $63^{\circ}C$, $64^{\circ}C$, $65^{\circ}C$ for 5 min. in MWH. 6. Thermoduric bacteria counts were $5.2{\times}10^4CFU/m{\ell}$ in raw milk untreated, $2.0{\times}10^3CFU/m{\ell}$ at $65^{\circ}C$ for 30 min. $1.9{\times}10^3CFU/m{\ell}$ at $70^{\circ}C$ for 30min. in MWH and $2.2{\times}10^3CFU/m{\ell}$ at $65^{\circ}C$ for 30 min. in WBH. Because thermoduric bacteria counts did not increased in MWH at $65^{\circ}C$, $70^{\circ}C$ for 30 min. and $65^{\circ}C$ for 30 min. in WBH during the 10days storaging. Also, thermoduric bacteria counts were a most drastic decrease after $61^{\circ}C$, $62^{\circ}C$, $63^{\circ}C$, $64^{\circ}C$, $65^{\circ}C$ for 5 min. in MWH. 7. Psychrotrophic bacteria counts were $2.8{\times}10^5CFU/m{\ell}$ in raw milk untreated, $2.0{\times}10^1CFU/m{\ell}$ at $65^{\circ}C$ for 30 min. $2.0{\times}10^1CFU/m{\ell}$ at $70^{\circ}C$ for 30 min. in MWH and $3.0{\times}10^1CFU/m{\ell}$ at $65^{\circ}C$for 30 min. in WBH. Because psychrotrophic bacteria counts did not increased in MWH at $65^{\circ}C$, $70^{\circ}C$ for 30min. and $65^{\circ}C$ for 30 min. in WBH during the 10 days storaging. Also, psychrotrophic bacteria counts were a most drastic decrease after $61^{\circ}C$, $62^{\circ}C$, $63^{\circ}C$, $64^{\circ}C$, $65^{\circ}C$ for 5 min. in MWH.

  • PDF

A numerical study on the characteristics of the smoke movement and the effects of structure in road tunnel fire (도로터널 화재시 연기의 전파특성과 구조체에 미치는 영향에 관한 수치 해석적 연구)

  • Yoo, Ji-Oh;Oh, Byung-Chil;Kim, Hyo-Gyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.3
    • /
    • pp.289-300
    • /
    • 2013
  • This study numerically considered the characteristic of smoke movement and the effect of hot smoke gas on tunnel wall surface temperature during road tunnel fire under boundary condition of fire growth curve that is applied to fire analysis in road tunnels. The maximum heat release rate were 20 MW and 100 MW and tunnel air velocities were 2.5 m/s and velocity induced by thermal buoyancy respectively, also the cooling effect of tunnel wall was considered. As results, when tunnel air velocity was constant at 2.5 m/s during tunnel fire, due to the cooling effect of tunnel wall, the smoke layer was rapidly descent after some distance and it flowed the same patterns at the downstream. When heat release rate was 100 MW (and jet fan was not installed), the maximum temperature of tunnel wall surface has risen up to $615^{\circ}C$. The heat transfer coefficient of tunnel wall surface was varied from 13 to $23W/m^2^{\circ}C$ approximately.

Design of MMA-Type Thermosetting Road Markings to Improve Reflectivity (재귀반사도 개선을 위한 MMA계 열경화성 차선도료의 설계)

  • Lee, Seung Bum;Lee, Chang Geun;Hong, In Kwon
    • Applied Chemistry for Engineering
    • /
    • v.26 no.4
    • /
    • pp.439-444
    • /
    • 2015
  • Several attempts to design the best-available thermosetting road markings by using MMA to improve the durability and retroreflectivity are presented in this paper. In order to improve field applicability, the components of main materials were designed by means of reducing the hardening time lower than eight minutes. The optimum mixing ratio of thermosetting road marking was TSRM-6 composed of 15.6 wt% of MMA monomer ($Tg=105^{\circ}C$), 6.0 wt% of PMMA (MW = 70,000, $Tg=60^{\circ}C$) and 1.2 wt% of TMPTA (MW = 338, $Tg=27^{\circ}C$). Also the homogeneous mixing of all components was necessary. The use of ceramic glass beads with an optimized TSRM-6 exhibited excellent performance by achieving retroreflectivity coefficients of 431, 354 and $172mcd{\cdot}m^{-2}{\cdot}lux^{-1}$ for dry, wet and rainy test condition, respectively at two hundred thousand cycles.

Prediction of Very High Critical Heat Flux for Subcooled Flow Boiling in a Vertical Round Tube (수직 원형관에서 서브쿨비등시 매우 높은 임계열유속의 예측)

  • Kwon, Young-Min;Hahn, Do-Hee
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.288-293
    • /
    • 2001
  • A critical heat flux (CHF) prediction method using an artificial neural network (ANN) was evaluated for application to the high-heat-flux (HHF) subcooled flow boiling. The developed ANN predictions were compared with the experimental database consisting of a total of 3069 CHF data points. Also, the prediction performance by the ANN was compared with those by mechanistic models and a look up table technique. The parameter ranges of the experimental data are: $0.33{\leq}D{\leq}37.5mm$, $0.002{\leq}L{\leq}4m$, $0.37{\leq}G{\leq}134Mg/m^2s$, $0.1{\leq}P{\leq}20MPa$, $50\leq{\Delta}h_{sub,in}\leq1660kJ/kg$, and $1.1{\leq}q_{CHF}\leq276MW/m^2$. $276MW/m^2$. It was found that 91.5% of the total data points were predicted within $a{\pm}20%$ error band, which showed the best prediction performance among the existing CHF prediction methods considered.

  • PDF

A Study on the Model Experiment for Smoke Flow in Road Tunnel Fire (도로터널 화재발생시 연기유동에 관한 축소모형실험 연구)

  • Kim, Jung-Yup;Shin, Hyun-Joon;Kang, Se-Gu;Ahn, Kyung-Chul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.6 no.2
    • /
    • pp.141-149
    • /
    • 2004
  • In this study, smoke movement in tunnel fire with natural and longitudinal ventilation systems has been investigated. Reduced-scale experiments were carried out under the Froude scaling using 14.55kW fire source with a wick and experimental data is obtained with 1/18 model tunnel test. Temperature profiles were measured under the ceiling and vertical direction along the center of the tunnel and poisonous gas was measured at emergency exit point. The results show that refuge time for 225m intervals of emergency exit in case of natural ventilation systems is 256 seconds and critical velocity for sufficient back-layer prevention is 2.8m/s for fire strength of 20MW.

  • PDF

Selectivity Estimation Using Compressed Spatial Histogram (압축된 공간 히스토그램을 이용한 선택율 추정 기법)

  • Chi, Jeong-Hee;Lee, Jin-Yul;Kim, Sang-Ho;Ryu, Keun-Ho
    • The KIPS Transactions:PartD
    • /
    • v.11D no.2
    • /
    • pp.281-292
    • /
    • 2004
  • Selectivity estimation for spatial query is very important process used in finding the most efficient execution plan. Many works have been performed to estimate accurate selectivity. Although they deal with some problems such as false-count, multi-count, they can not get such effects in little memory space. Therefore, we propose a new technique called MW Histogram which is able to compress summary data and get reasonable results and has a flexible structure to react dynamic update. Our method is based on two techniques : (a) MinSkew partitioning algorithm which deal with skewed spatial datasets efficiently (b) Wavelet transformation which compression effect is proven. The experimental results showed that the MW Histogram which the buckets and wavelet coefficients ratio is 0.3 is lower relative error than MinSkew Histogram about 5%-20% queries, demonstrates that MW histogram gets a good selectivity in little memory.