• Title/Summary/Keyword: 2-universal

Search Result 2,014, Processing Time 0.027 seconds

A Case Study on Evaluation of Educational Space in point of Universal Design - Focused on G Elementary School - (교육공간에 대한 유니버설 디자인 관점에서의 평가 사례연구(1) - G초등학교 사례를 중심으로 -)

  • Oh, Chan-Ohk;Park, Jin-Kyung
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.5
    • /
    • pp.12-22
    • /
    • 2012
  • The demand on design for human diversity is increasing in the field of spatial design. This study evaluated the spatial environment of G elementary school in point of universal design. The study was carried out by the observing and measuring method and the survey method. It focused on 53 universal design related items which consisted of 5 principles; accessibility, supportiveness, adaptiveness, safety, and equality. The subjects for the survey were 170 students from first to sixth grade of G elementary school. Findings were as follows ; 1) The elementary school had many barriers for the wheelchair users to use. 2) The width of door and passage between desks, and the front and back space in classroom were not wide to pass through. Also, the students responded that the size of desk, chair, and individual locker was not enough. That is, Some items of accessibility and supportiveness were not met in classrooms. 3) Most items related to restroom were evaluated negatively by the students. 4) The dining tables were arranged monotonously in a rows. This emphasized the institutional mood. 5) Some evaluations to their school environment were significantly different by their gender and grade.

  • PDF

Effect of adaptive motion on cyclic fatigue resistance of a nickel titanium instrument designed for retreatment

  • Ozyurek, Taha;Yilmaz, Koray;Uslu, Gulsah
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.1
    • /
    • pp.34-38
    • /
    • 2017
  • Objectives: The aim of this study was to evaluate the cyclic fatigue resistance of the ProTaper Universal D1 file (Dentsply Maillefer) under continuous and adaptive motion. Materials and Methods: Forty ProTaper Universal D1 files were included in this study. The cyclic fatigue tests were performed using a dynamic cyclic fatigue testing device, which had an artificial stainless steel canal with a $60^{\circ}$ angle of curvature and a 5 mm radius of curvature. The files were randomly divided into two groups (Group 1, Rotary motion; Group 2, Adaptive motion). The time to failure of the files were recorded in seconds. The number of cycles to failure (NCF) was calculated for each group. The data were statistically analyzed using Student's t-test. The statistical significant level was set at p < 0.05. Results: The cyclic fatigue resistance of the adaptive motion group was significantly higher than the rotary motion group (p < 0.05). Conclusion: Within the limitations of the present study, the 'Adaptive motion' significantly increased the resistance of the ProTaper Universal D1 file to cyclic facture.

Concurrent Validity, Inter-Tester and Intra-Tester Reliability of Goniometric Measurement of Active Elbow Range of Motion Using 4 Different Types of Measuring Instruments (주관절 가동범위 측정법에 대한 동시타당도와 신뢰도)

  • Current, Marion E.;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.2 no.2
    • /
    • pp.46-55
    • /
    • 1995
  • The purpose of this study was to assess the concurrent validity and reliability of goniometric measurement of joint motion. Subjects were 40 healthy university students. Measurements were performed by 4 inexperienced physical therapy students. Four different instruments were used and three readings were taken with each instrument in random order making a total of 12 readings for flexion of the right elbow of each subject. Goniometers used were 1. universal 2. fluid-based goniometer/inclinometer 3. digital LCD goniometer 4. electronic goniometer/torsiometer. The results were as follows: Concurrent validity was highest (r= .94) with the universal and digital LCD tools. Interrater reliability (Pearson Product Moment Correlation) was good for each tool. Interrater reliability calculated by ICC(2,1) was highest (.96) with the tensiometer and lowest (.78) with the digital LCD goniometer. Intrarater reliability calculated by ICC was excellent (${\geq}.90$) for all instruments. These results show that concurrent validity, intrarater and interrater reliability are very good in the used of all four types of goniometers/inclinometer/tensiometer, even with inexperienced raters. These results confirm the almost universal reliance on hand held goniometers for joint measurement by physical therapists as being a reliable practice. Further research should be done clinically with actual patients.

  • PDF

Process Controllability and Stability in Organic Vapor Phase Deposition

  • Schwambera, M.;Gersdorff, M.;Reinhold, M.;Meyer, N.;Strauch, G.;Marheineke, B.;Heuken, M.;Zhou, T.X.;Ngo, T.;Brown, J.J.;Shtein, M.;Forrest, S.R.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.824-827
    • /
    • 2004
  • High performance green $Ir(ppy)_3$-based phosphorescent OLEDs (PHOLEDs) have been fabricated by organic vapor phase deposition ($OVPD^{TM}$). In addition to demonstrating both efficiency and operational device lifetime comparable to devices built by vacuum thermal evaporation, we report on the controllability and stability of the $OVPD^{TM}$ process. Specifically, run-to-run and day-to-day deposition rate reproducibility of better than 2 % for three consecutive days is demonstrated.

  • PDF

Another Myth: The Implicature Theory of Even

  • An, Young-Ran
    • Korean Journal of English Language and Linguistics
    • /
    • v.2 no.3
    • /
    • pp.403-430
    • /
    • 2002
  • With a view to providing a unitary interpretation of a lexical item, even, this paper proposes that even be understood as a quantifier. To countenance this idea, the quantifier theories will be evaluated against the implicature accounts on the basis of conceptual and empirical evidence. With the help of Bach (1999), the quantifier theories of even are regarded as most viable and plausible. On the other hand, from among different quantifier approaches even will be viewed as a quasi-universal quantifier, which means that even is similar to the universal quantifier but still it is different from it. That is, even introduces a comparison set that is context-dependent and only the salient members of this comparison set will be taken into account when an even-sentence is to be uttered. This observation is based on the formal representation for a universal quantifier in general on the one hand and the truth-conditional contribution of even to the sentence containing it.

  • PDF

An Implimentation of the uniersal signalling equipment using DSP in Digital Switching System (DSP를 이용한 전전자식 교환기용 universal 신호장치의 개발)

  • 장말숙;김수홍;성승희;김근배;하영상;박찬옹
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1987.04a
    • /
    • pp.86-92
    • /
    • 1987
  • We implement an universal signaling equipment including many kinds of singling devices just as R2 MFC seder.receiver DTMF sender/receiver Tone sender sued in Digital Switching System the universal signaling equipment has two parts sender part and receiver part. The sender part is implemnted with ROM-LOOK-UP Table method and the receiver part is implemnted that the equipment satisfies the Recomandations of CCITT. Also the capability of the equipment is evaluated by the LCS(Local Call Simulatior)Test in the TDX-1A system.

  • PDF

DERIVATION MODULES OF GROUP RINGS AND INTEGERS OF CYCLOTOMIC FIELDS

  • Chung, I.Y.
    • Bulletin of the Korean Mathematical Society
    • /
    • v.20 no.1
    • /
    • pp.31-36
    • /
    • 1983
  • Let R be a commutative ring with 1, and A a unitary commutative R-algebra. By a derivation module of A, we mean a pair (M, d), where M is an A-module and d: A.rarw.M and R-derivation, i.e., d is an R-linear mapping such that d(ab)=a)db)+b(da). A derivation module homomorphism f:(M,d).rarw.(N, .delta.) is an A-homomorphism f:M.rarw.N such that f.d=.delta.. A derivation module of A, (U, d), there exists a unique derivation module homomorphism f:(U, d).rarw.(M,.delta.). In fact, a universal derivation module of A exists in the category of derivation modules of A, and is unique up to unique derivation module isomorphisms [2, pp. 101]. When (U,d) is a universal derivation module of R-algebra A, the A-module U is denoted by U(A/R). For out convenience, U(A/R) will also be called a universal derivation module of A, and d the R-derivation corresponding to U(A/R).

  • PDF

Development of The M-PHY AFE Block Using Universal Components (범용 부품을 이용한 M-PHY AFE Block 개발)

  • Choi, Byung Sun;Oh, Ho Hyung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.2
    • /
    • pp.67-72
    • /
    • 2015
  • For the development of UFS device test system, M-PHY specifications should be matched with MIPI-standard which is analog signal protocol. In this paper, the implementation methodology and hardware structure for the M-PHY AFE (Analog Front End) Block was suggested that it can be implemented using universal components without ASIC process. The testing procedure has a jitter problem so to solve the problems we using ASIC process, normally but the ASIC process needs a lot of developing cost making the UFS device test system. In is paper, the suggestion was verified by the output signal which was compared to the MIPI-standard on the Prototype-board using universal components. The board was reduced the jitter on the condition of HS-TX and 5.824 Gbps Mode in SerDes (Serialize-deserializer). Finally, the suggestion and developed AFE block have a useful better than ASIC process on developing costs of the industrial UFS device test system.

Error Model and Accuracy Analysis of a Cubic Parallel Device

  • Lim, Seung-Reung;Park, Woo-Chun;Song, Jae-Bok;Daehie Hong
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.2 no.4
    • /
    • pp.75-80
    • /
    • 2001
  • An error analysis is very important to estimate performance of a precision machine. This study proposes an error analysis for a new parallel device, a cubic parallel device. The cubic parallel manipulator has error sources including upper and lower universal joint errors due to the directional changes in the link and actuation errors. The maximum errors of the end effector are affected by the axial direction changes of each links and the clearances of the universal joints when the parallel manipulator is moving along a path. It is found that the changes of errors mostly occur at the positions where the directions of exerting link forces shift. The error analysis is based on an error model formed from the relation between the universal point errors and the end-effector accuracy. The analysis method can be also used in predicting the accuracy of other parallel devices.

  • PDF