• Title/Summary/Keyword: 2-point calculation

Search Result 462, Processing Time 0.032 seconds

Kinetics calculation of fast periodic pulsed reactors using MCNP6

  • Zhon, Z.;Gohar, Y.;Talamo, A.;Cao, Y.;Bolshinsky, I.;Pepelyshev, Yu N.;Vinogradov, Alexander
    • Nuclear Engineering and Technology
    • /
    • v.50 no.7
    • /
    • pp.1051-1059
    • /
    • 2018
  • Fast periodic pulsed reactor is a type of reactor in which the fission bursts are formed entirely with external reactivity modulation with a specified time periodicity. This type of reactors could generate much larger intensity of neutron beams for experimental use, compared with the steady state reactors. In the design of fast periodic pulsed reactors, the time dependent simulation of the power pulse is majorly based on a point kinetic model, which is known to have limitations. A more accurate calculation method is desired for the design analyses of fast periodic pulsed reactors. Monte Carlo computer code MCNP6 is used for this task due to its three dimensional transport capability with a continuous energy library. Some new routines were added to simulate the rotation of the movable reflector parts in the time dependent calculation. Fast periodic pulsed reactor IBR-2M was utilized to validate the new routines. This reactor is periodically in prompt supercritical state, which lasts for ${\sim}400{\mu}s$, during the equilibrium state. This generates long neutron fission chains, which requires tremendously large amount of computation time during Monte Carlo simulations. Russian Roulette was applied for these very long neutron chains in MCNP6 calculation, combined with other approaches to improve the efficiency of the simulations. In the power pulse of the IBR-2M at equilibrium state, there is some discrepancy between the experimental measurements and the calculated results using the point kinetics model. MCNP6 results matches better the experimental measurements, which shows the merit of using MCNP6 calculation relative to the point kinetics model.

Two Novel 3-D Zinc Compounds with Mixture Ligands of H3BTB and 4,4'-Bipy: Crystal Structures, Blue Fluorescence and Single Point Energy Calculation

  • Zhang, Xiu-Cheng;Xu, Ling;Liu, Wen-Guang;Liu, Bing
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.9
    • /
    • pp.2598-2602
    • /
    • 2010
  • Two 3-D zinc framework compounds, $[Zn_6(BTB)_4(4,4'-bipy)_4(H_2O)_4]{\cdot}9H_2O$ (1) and $[Zn_3(BTB)_2(4,4'-bipy)_2(H_2O)_2]{\cdot}5H_2O$ (2) ($H_3BTB$ = 1,2,3-benzenetricarboxylic acid, 4,4'-bipy = 4,4'-bipyridine), are obtained from the diffusion method and hydrothermal reaction respectively. Though 1 and 2 has the same coordination geometries of zinc atoms and coordination mode of $BTB^{3-}$, their 2-D layers are different: mirror symmetric layers in 1; parallel ones in 2, further connecting by 4,4'-bipy into 3-D frameworks. The hydrothermal reaction of 2 results in a more stable 3-D framework than the one in 1, which is supported by the single point energy calculations. 1 and 2 show similar blue fluorescence at 417 nm, which can be assigned to LMCT.

Calculation of gamma buildup factors for point sources

  • Kiyani, Abouzar;Karami, Abbas Ali;Bahiraee, Marziye;Moghadamian, Hossein
    • Advances in materials Research
    • /
    • v.2 no.2
    • /
    • pp.93-98
    • /
    • 2013
  • Objective of this study is to calculate gamma buildup factors for pointed and isotropic gamma sources in depleted uranium, uranium dioxide, natural uranium, tin, water and concrete using MCNP4C code. The thickness of the media ranges from 0.5 to 10 mean-free-path (mfp) and gamma energy ranges from 0.5 to 10 MeV. Owing to the outstanding accuracy of MCNP in calculation involving gamma interaction, results fairly match those reported previously. The maximum relative error is 2%.

Quality Assurance on Dose Distribution of Ir-192 Line Source (Ir-192 선 선원의 선량분포에 관한 품질보증)

  • Kim, Jong-Eon
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.33-38
    • /
    • 2007
  • The propose of this study is a verification of the correct calculation of the dose around source and the prescription dose of Ir-192 source in the plato treatment planning system. The source and orthogonal coordinates for lateral direction and those for the anterior posterior direction were drawn on a A4 paper and then input into the system. The prescription dose was prescribed to two points with radius 1 cm in the direction of polar angle $90^{\circ} and $270^{\circ} from the center of the source. The doses of prescription point and dose points acquired from the treatment planning system were compared with those from manual calculation using the geometry function formalism derived by Paul King et al. In this analysis, the doses of prescription point were exactly consistent with each other and those of dose points were obtained within the error point of 1.85%. And the system of accuracy was evaluated within 2% of tolerance error. Therefore, this manual dose calculation used for the geometry function formalism is considered to be useful in clinics due to its convenience and high quality assurance.

  • PDF

A Study on Centrifugal Compressor Design Optimization for Increasing Surge Margin (서지 마진 증가를 고려한 원심 압축기 설계 최적화)

  • Chai, Jae-Ha
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.2
    • /
    • pp.38-45
    • /
    • 2008
  • This study presents a numerical procedure to optimize the compressor design to increase the surge margin of compressor with response surface method (RSM). The Box-Behnken design method is used to reduce the number of calculation for fitting the second-order response surface. In order to consider the increase of surge margin during numerical optimization without any calculation at the surge point, the slope of compressor characteristic curve at the design point is suggested as an objective function in the present optimization problem. Mean line performance analysis method is used to get the design and off-design characteristic curves of centrifugal compressor. The impeller exit angle, impeller exit height and impeller radius are chosen as design variables. The optimum shapes show the increase of surge margin for the surge margin optimization and increase of efficiency for the efficiency optimization in comparison with an initial shape.

Calculation of Tissue-Air Ratios(TAR) in Irregularly shaped Field for Co-60 Gamma Radiation (CO-60 감마선에 대한 부정형조사면의 조직공중선량비 (TAR) 계산)

  • Ji Young-Hoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.3 no.1
    • /
    • pp.27-36
    • /
    • 1989
  • In order to calculate the dose on each interest point in five types of irregularly shaped fields used commonly in radiotherapy, the tissue-air ratios (TAR) in these fields for Go-60 gamma radiation were calculated using the newly devised SAR-chart. The TARs calculated from newly method of using the SAR-chart, computer method and approximation method at the interest point were compared to the TARs obtained from measurement. The result are as follows; In case of the interest points on central axis the calculated TARs in irregularly shaped fields by the above mentioned methods were well agreed within the error of $1\%$, whereas for the interest points on off-axis the calculated TARs were resulted in the maximum errors of $2.4\%,\;2.3\%$ and $8.8\%$ respectively. From these results, the accuracy of calculation method of using the SAR-chart was comfirmed.

  • PDF

A Study on the Transaction Volume Calculation model for Improving the Measurement Accuracy of Hydrogen Fuelling Station (수소충전소 계량 정확도 향상을 위한 거래량 산출 모델 연구)

  • JINYEONG CHOI;HWAYOUNG LEE;SANGSIK LIM;JAEHUN LEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.6
    • /
    • pp.692-698
    • /
    • 2022
  • With the expansion of domestic hydrogen fuelling station infrastructure, it is necessary to secure reliability among hydrogen traders, and for this, technology to accurately measure hydrogen is important. In this study, 4 types of hydrogen trading volume calculation models (model 1-4) were presented to improve the accuracy of the hydrogen trading volume. In order to obtain the reference value of model 4, and experiment was conducted using a flow rate measurement equipment, and the error rate of the calculated value for each model was compared and analyzed. As a result, model 1 had the lowest metering accuracy, model 2 had the second highest metering accuracy and model 3 had the highest metering accuracy until a certain point. But after the point, model 2 had the highest metering accuracy and model 3 had the second metering accuracy.

Point Cloud Measurement Using Improved Variance Focus Measure Operator

  • Yeni Li;Liang Hou;Yun Chen;Shaoqi Huang
    • Current Optics and Photonics
    • /
    • v.8 no.2
    • /
    • pp.170-182
    • /
    • 2024
  • The dimensional accuracy and consistency of a dual oil circuit centrifugal fuel nozzle are important for fuel distribution and combustion efficiency in an engine combustion chamber. A point cloud measurement method was proposed to solve the geometric accuracy detection problem for the fuel nozzle. An improved variance focus measure operator was used to extract the depth point cloud. Compared with other traditional sharpness evaluation functions, the improved operator can generate the best evaluation curve, and has the least noise and the shortest calculation time. The experimental results of point cloud slicing measurement show that the best window size is 24 × 24 pixels. In the height measurement experiment of the standard sample block, the relative error is 2.32%, and in the fuel nozzle cone angle measurement experiment, the relative error is 2.46%, which can meet the high precision requirements of a dual oil circuit centrifugal fuel nozzle.

Contact Point Analysis for Wheel/Rail Contact Force Calculation (차륜/레일간의 접촉력 계산을 위한 접촉점 해석 알고리즘)

  • 박정훈;임진수;황요하;김창호
    • Journal of the Korean Society for Railway
    • /
    • v.2 no.3
    • /
    • pp.1-8
    • /
    • 1999
  • In this paper, descibed was the derived algorithm for calculating contact point between wheel and rail and the developed method for rail modeling. The proposed methods use travelling distance to represent rail center line position vector and rail orientation with respect to Newtonian reference frame. The methods call be easily used ill multibody dynamic analysis. Two numerical examples are shown to verify the validity of the proposed methods.

  • PDF