• Title/Summary/Keyword: 2-level

Search Result 56,057, Processing Time 0.067 seconds

Value orientation and the relationship between nurse′s role perception and patient′s expectation on selected routine nursing activities (간호원의 역할인식과 환자의 기대 -기본 간호역할의 가치의식을 중심으로-)

  • 한윤복;김순자;이인자
    • Journal of Korean Academy of Nursing
    • /
    • v.4 no.2
    • /
    • pp.144-158
    • /
    • 1974
  • This study was undertaken in an attempt to; 1) measure value orientation of nursing activities, 2) identify the relationship between nurse's role perception and patient's expectation, and 3) evaluate the pattern of nursing education and nursing service administration. 203 hospitalized adults and 203 professional nurses from 11 general hospitals in Seoul during the period of July to December 1973 were tested according to questionnaire based on 4 categories of clinical nursing activities, 1) physical care, 2) observation and control, 3) psycho-social care and 4) therapeutic measures. Results of the study are as follows: 1. Nurses were more concerned than patients in the physical care category. Significant difference was revealed by p<.01 level (t=2.800). Mean value score of nurses was average (2.84), and mean value score of patients was relative' y low (2.49). None of the physical care category questionnaire items were over 3.5. 2. Respondents from hospitals of total care system revealed significant difference in the physical care category by P〈.025 level. (t=2.242). Mean value score of both group were average level (nurse 2.90, patient 2.53), nurses showed higher concern. 3. Difference between nurse's role perception and patient's expectation in observation and control category was revealed non- significance by p〉0.05. level (t=1.238). Mean value score of both group revealed relatively high (nurse=3.44, patient 3.19). 4. Difference between nurse's role perception and patient〉expectation in psycho-social cart category revealed non- significance by p〉.05 level (t=0.758), Mean value score of both group revealed average level (nurse =2.71, patient =2.53), 5. Non- significant difference was noted between B. S. N. and diploma nurse's role perception in the psycho- social care category by p> 0.1 level (t=0.316). 4. Difference between nurse's role perception and patient's expectation in the rapeutic me assures category revealed non- significance by p〉0.05 level) t=0.503). Horses showed high concern by mean value score 3.56 level and patients relatively high by 3.41. All items of this category revealed very high or relatively high value score.

  • PDF

Three-phase 3-level and 2-level SVPWM Implementation with 100 kHz Switching Frequency using FPGA (FPGA를 이용한 100 kHz 스위칭 주파수의 3상 3-level과 2-level의 SVPWM의 구현)

  • Moon, Kyeong-Rok;Lee, Dong-Myung
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.19-24
    • /
    • 2020
  • This paper presents a 3-level, 2-level SVPWM technique with 100 kHz switching using Verilog HDL, one of the languages of FPGA. In the case of IGBT devices mainly used in inverters, they have a switching frequency around 20kHz. Recent research and development of next-generation power semiconductor devices such as GAN has enabled switching of more than 100kHz, which can miniaturize power converters, and apply various new algorithms due to the injection of harmonics. In the existing system using the IGBT, the control using the DSP is common, but the controller configuration for 100 kHz switching requires the use of FPGA. Therefore, this paper explains the theory and implementation of SVPWM applied to two-level and three-level inverters using FPGAs and verifies the performance through the output waveform. In addition, this paper implements 3-level SVPWM by using only one carrier instead of using two carriers in the conventional method.

N-methyl-N'-nitro-N-nitrosoguanidine Reduces the Intracellular Calcium Level Through NAD Depletion in NIH3T3 Cells

  • Yoon, Yoo-Sik;Shin, In-Cheol;Kim, Jin-Woo;Kang, Ke-Won;Joe, Cheol-O
    • BMB Reports
    • /
    • v.28 no.5
    • /
    • pp.392-397
    • /
    • 1995
  • The effect of N-methyl-N'-nitro-N-nitrosoguanidine (MNNG) on the intracellular $Ca^{2+}$ level was studied in NIH3T3 fibroblast cells. A reduction of the intracellular $Ca^{2+}$ level was observed after exposure to 300 ${\mu}m$ MNNG. However, the intracellular level of $IP_3$, a well-known regulator of $Ca^{2+}$ release from internal storage, was not changed by MNNG treatment. Instead, a reduction of the intracellular NAD level was observed. NAD as well as $IP_3$ stimulated intracellular $Ca^{2+}$ release from permeabilized cells. The treatment of 3-aminobenzamide, which inhibited the MNNG-induced reduction of the NAD level, also prevented the MNNG-induced decrease of the $Ca^{2+}$ level. Our data suggest that MNNG reduces the intracellular $Ca^{2+}$ level by NAD depletion in NIH3T3 cells.

  • PDF

A Study on the Activity and Training Plan of a Field Crew for the Design of Training Scenarios Assuming Chemical Accidents and Terrorism (화학사고·테러를 가정한 훈련 시나리오 설계를 위한 현장 대원의 활동성 분석과 훈련방안에 관한 연구)

  • Kim, Si-Kuk;Choi, Su-Gil;Hong, Sung-chul
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.72-85
    • /
    • 2020
  • This article is a study on the activity of rescue workers for designing simulation training scenarios assuming chemical accidents. On the basis of the complexity of the indoor scene in the case of chemical accidents and terrorism, we designed a 12-step simulation training scenario for two teams to analyze the improvement in firefighters' capabilities. On the basis of activity measurement in the simulation scenario, step 2 of training had the most drops in the maximum heart rate, as follow: N1, from 163 bpm to 153 bpm; N2, from 186 bpm to 151 bpm; N3, from 168 bpm to 162 bpm; and N4, from 166 bpm to 152 bpm. In terms of intensity level in the allowable activity time, it was found that in step 2 both N1 and N2 reduced from Level 5 to Level 3, N3 remained at Level 4, N4 reduced from Level 4 to Level 3, and the maximum allowable activity time increased.

Traits of Water Level Control by Sluice Gates and Halophyte Community Formation in Saemangeum (새만금 배수갑문 수위조절 특성과 염생식물 군락지 형성에 관한 연구)

  • Sin, Myoung-Ho;Kim, Chang-Hwan
    • Korean Journal of Environment and Ecology
    • /
    • v.24 no.2
    • /
    • pp.186-193
    • /
    • 2010
  • In order to examine the traits of sluice gate water control, halophyte community formation and their inter-relations in Saemangeum, both water level condition and halophyte community formation were analyzed periodically and spatially on the topographic map with Surfer, Saemageum Spatial Analysis System, and related field reports. The traits of water level condition are that average water level in the growing period of halophytes was similar to annual average water level, annual low level and high level appeared in the growing period, and water level was usually maintained within a range of -1.0m~0.5m above mean sea level, but it has changed more frequently year by year. Routine water level control, natural disaster prevention, construction, and civil appeal took major percentages of the reasons for sluice gate's opening and shutting. Since 2007, not only the overall control frequency of sluice gate but also its control frequency for construction and natural disaster prevention have increased outstandingly. Halophyte community had formed at a rate of 1,209ha/year in the 4,315 ha land in 2008, 6.3 times larger than in 2005, and 2,382 ha above around 1.0m was estimated to be artificially vegetated, 89.1 % of the 2,673ha-size sown area. High water level was found to be a more possible determinant than average water level or low water level in halophyte community formation and it was thought to be secondary factors whether tillage was conducted or/and whether surface sealing formed.

Comparative analysis of methods for sediment level estimation in dam reservoir (댐 저수지의 퇴사위 결정 방법에 관한 연구)

  • Joo, Hong Jun;Kim, Hung Soo;Cho, Woon ki;Kwak, Jae won
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.1
    • /
    • pp.61-70
    • /
    • 2018
  • This study examined how to determine the optimal sediment level in dam reservoir for efficient plan and operation of dam. Currently, Korea is applying a horizontally accumulated method for sediment level estimation for the safety design of dam and so the method estimated relatively higher level than others. However, the sediment level of dam reservoir should be accurately estimated because it is an important factor in assessing life cycle of a dam. The sediment level in dam reservoir can be determined by SED-2D model linked with RMA-2, horizontally accumulated method, area increment method, and empirical area reduction method. The estimated sediment level from each method was compared with the observed sediment level measured in 2007 in Imha dam reservoir, Korea and then the optimal method was determined. Also, the future sediment level was predicted by each method for the future trend analysis of sediment level. As the results, the most accurate sediment level was estimated by the empirical area reduction method and the future trend of sediment level variation followed the past trend. Therefore, we have found that the empirical area reduction method is a proper one for more accurate estimation of sediment level and it can be validated by the results from a numerical model of SED-2D linked with RMA-2 model.

KOMPSAT2 TERMINAL POLAR STATION MASS PRODUCTION TEST

  • Kang, Ji-Hoon;Lee, Chol;Kim, Tae-Hoon;Ahn, Sang-Il
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.375-377
    • /
    • 2008
  • The KOMPSAT2 Terminal Polar Station was recently installed at near North Pole, Tromso, and Toulouse. The K2PS consists of one receiving station and two processing sites. The receiving station has been installed at SvalSat ($N78^{\circ}$, $E15^{\circ}$ ), and the two receiving sites have been installed at KSAT (Kongsberg Satellite Service AS), Tromso, Norway ($N69^{\circ}$ ,$E18^{\circ}$ ) and SISA, Toulouse, France ($N43^{\circ}$ ,$E1^{\circ}$ ). The products ofK2PS system can be classified to two categories: Level 1R product and Level 1G product. The Level 1R product is radiometric corrected product with RPC (Rational Polynomial Coefficients) and the Level 1G product is geometric corrected product with POD (Precise Orbit Data) and PAD (Precise Attitude Data) data based on Level 1R product. To meet a SISA (Spot Image SA)'s requirement, K2PS system has high performance product producing capability. This paper describes overall K2PS systems' production generation flow and the mass production test result of K2PS systems.

  • PDF

A Study on the perception Level of Nursing Students in the First Clinical practice (첫 임상 실습에 대한 간호학생의 인지 정도에 관한 연구)

  • Park Chung-Ja;Lee Kyung-Hee
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.1 no.2
    • /
    • pp.149-164
    • /
    • 1994
  • This stidy was carried out for purpose of investigating the degree of perception in the First clinical practice. The data of this study were collected by self-reported questionnaire composed of 5point rating scale measure the ideal level, satisfaction level and Stress level. For the analysis of the data, percentage, MANOVA, ANOVA and Scheffe test were 216 nursing students in 1 Junior College and 2 university in Taegu. Data was administrated from October 4 through 13, 1994 The results were as follow : 1. The average mean Score for the ideal level was 3.91 with a maximum possible score 5points. The highest mean score was infection controll 4.40 and the lowest mean score was comfort measure 3.44. The average mean score for the satisfaction level was 3.33 with a maximum possible score 5points. The highest mean score was Medication 3.54 and the lowest mean score was communication 3.01. The average mean score for stress level was 3.10 with a maximum possible score 5points. The highest mean score was spiritual and psychological care 3.45, the lowest mean score was Temperature controll 2.51. 2. In the analysis of the relationship between the ideal level, Satisfaction level and Stress level, no significant differance was found in college and university, religion, admission, satisfaction, health, economy, parent 3. In the analysis of the relationship between the ideal level, satisfaction level, stress level and general characteristics, significant difference was found in economicststus in the ideal level. Significant difference was found in economic status(upper class, middle class)in Scheffe test of the ideal level.

  • PDF

ANALYSIS OF TWO COMMODITY MARKOVIAN INVENTORY SYSTEM WITH LEAD TIME

  • Anbazhagan, N.;Arivarignan, G.
    • Journal of applied mathematics & informatics
    • /
    • v.8 no.2
    • /
    • pp.519-530
    • /
    • 2001
  • A two commodity continuous review inventory system with independent Poisson processes for the demands is considered in this paper. The maximum inventory level for the i-th commodity fixed as $S_i$(i = 1,2). The net inventory level at time t for the i-th commodity is denoted by $I_i(t),\;i\;=\;1,2$. If the total net inventory level $I(t)\;=\;I_1(t)+I_2(t)$ drops to a prefixed level s $[{\leq}\;\frac{({S_1}-2}{2}\;or\;\frac{({S_2}-2}{2}]$, an order will be placed for $(S_{i}-s)$ units of i-th commodity(i=1,2). The probability distribution for inventory level and mean reorders and shortage rates in the steady state are computed. Numerical illustrations of the results are also provided.

Multi-unit Level 2 probabilistic safety assessment: Approaches and their application to a six-unit nuclear power plant site

  • Cho, Jaehyun;Han, Sang Hoon;Kim, Dong-San;Lim, Ho-Gon
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1234-1245
    • /
    • 2018
  • The risk of multi-unit nuclear power plants (NPPs) at a site has received considerable critical attention recently. However, current probabilistic safety assessment (PSA) procedures and computer code do not support multi-unit PSA because the traditional PSA structure is mostly used for the quantification of single-unit NPP risk. In this study, the main purpose is to develop a multi-unit Level 2 PSA method and apply it to full-power operating six-unit OPR1000. Multi-unit Level 2 PSA method consists of three steps: (1) development of single-unit Level 2 PSA; (2) extracting the mapping data from plant damage state to source term category; and (3) combining multi-unit Level 1 PSA results and mapping fractions. By applying developed multi-unit Level 2 PSA method into six-unit OPR1000, site containment failure probabilities in case of loss of ultimate heat sink, loss of off-site power, tsunami, and seismic event were quantified.