On the Measurement Technique of Void Fraction by Single Camera Two Phase PIV (단일 카메라 입자영상유속계를 이용한 이상유동 기포율 측정방법)

  • Choi, Dong-Whan;Sung, Jae-Yong;Yoo, Jung-Yul
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1558-1563
    • /
    • 2004
  • A measurement technique for the void fraction and the bubble dynamics in gas-liquid two-phase flows has been proposed using a time-resolved two-phase PIV system. For the three-dimensional evaluation of the bubble information, both the images from the front and side views are simultaneously recorded into a high speed CCD camera by reflecting the side image into the front view with the help of a $45^{\circ}$ oriented mirror. Then, a stereo-matching technique is applied to calculate the void fraction, bubble size and shape. To obtain the rising bubble velocities, the 2-frame PTV method was applied. Consequently, the present technique shows good feasibility for the measurements of the volume fractions, mean diameters, aspect ratios and velocities of the bubbles at the three-dimensional point of view.

  • PDF

THEORITICALL ANALYSIS OF TEMPERATURE DISTRIBUTION IN TWO-DIMENSIONAL FIELD USING F.E.M (유한요소법을 이용한 2차원 Field 내의 온도분포의 이론적 해석)

  • Kim, N.H.;Choi, C.S.;Choi, H.H.;Hong, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1292-1295
    • /
    • 1987
  • In noninvasive temperature measurement within body, this paper is presented temperature measurement method in security and with effect from Applicator by electromagnetic, and it is analyzed heat generation quantity or temperature rise distribution by computer simulation within body. In this paper, two-dimensional model is considered and temperature distribution produced by RF capacitive heating system is analyzed by using Finit Element Method (F.E.M). A passibility of temperature distribution control is examined based on the position and size of Applicator.

  • PDF

Development of Digital Particle Holographic System for Measurements of the Characteristics of Spray Droplets (분무 액적 특성 계측을 위한 디지털 입자 홀로그래피 시스템의 개발)

  • Yan, Yang;Kang, Bo-Seon
    • Journal of ILASS-Korea
    • /
    • v.15 no.2
    • /
    • pp.53-60
    • /
    • 2010
  • This study presents development of digital particle holographic system and its application to spray field to measure three-dimensional velocities and sizes of spray droplets. A double exposure hologram recording system with synchronization system for time control was established and digital holograms can be recorded in a short time interval. To process recorded holograms, the correlation coefficient method was used for focal plane determination of particles. To remove noises and improve the quality of holograms and reconstructed images, the Wiener filter was adopted. The two-threshold and image segmentation methods were used in binary image transformation. For particle pairing, the match probability method was adopted. The developed system was applied to spray field and three-dimensional velocities and sizes of spray droplets were measured. The measurement results of digital holographic system were compared with those made by laser instruments, PDPA(Phase Doppler Particle Analyzer), which proved the feasibility of in-line digital particle holographic system as a good measurement tool for spray droplets.

Video-based 3-dimensional tracking system (영상을 이용한 3차원 위치 추적 시스템 개발1)

  • 박경수;반영환;이안재;임창주
    • Proceedings of the ESK Conference
    • /
    • 1996.10a
    • /
    • pp.160-165
    • /
    • 1996
  • This paper presents the development of video-based 3-dimensional tracking system. Measurement of human motion is important in the application of ergonomics. The system uses advanced direct video measurement technology. Passive retro-reflecting markers are attached to a subject and movements of markers are observed by two CCD cameras. Infrared light emitted near the CCD cameras is reflected by the markers and is detected by the cameras. The image ae captured by Samsung MVBO2 board and the center of markers is calculated by DSP program. The position of markers are transferred from MVB02 board to the computer through AT bus. The computer then tracks the position of each marker and saves the data. This system has dynamic accuracy with 1% error and the sampling rate to 6-10 Hz, and can analyse the trajectory and speed of the marker. The results of this study can be used for operators motion analysis, task analysis, and hand movement characteristic analysis.

  • PDF

Noncontact Type Three Dimensional Profile Measurement for CAD Modeling of Sculptured Surface (자유곡면의 CAD 모델링을 위한 비접촉식 삼차원 형상측정)

  • Park, H.G.;Park, Y.B.;Kim, S.W.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.1
    • /
    • pp.5-14
    • /
    • 1995
  • An optical measurement method of three dimensional surface profiles which is named the slit beam projection is suggested and practically implemented. This method is intended especially for noncontact and fast digitization of sculptured surfaces for CAD modeling and die manufacturing. Its basic principles are based on geometric optics. Deatiled optical principles and an sub-pixel image processing technique to enhance the measuring resolutions are described in this study. The measuring performances of the slit beam projection are presented and discussed to demonstrate that an actual measuring accuracy of below .+-. 0.2mm can be achived over the whole measuring range(500mm*300mm*200mm)

  • PDF

Ultra High-speed 3-dimensional Profilometry Using a Laser Grating Projection System

  • Park, Yoon-Chang;Ahn, Seong-Joon;Kang, Moon-Ho;Kwon, Young-Chul;Ahn, Seung-Joon
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.4
    • /
    • pp.464-467
    • /
    • 2009
  • The grating projection method with phase-shifting technique is very useful in measuring the 3-dimensional (3D) shape with high accuracy and speed. In this work, we have developed an ultra high-speed digital laser grating projection system using a high-power laser diode and a highsensitivity CMOS camera. With our system, the optical measurement required to find out the profile of a 3D object could be carried out within 2.6 ms, which is a significant ($\sim$10 times) improvement compared with those of the previous studies.

Fabrication of Two-Dimensional Array Hydrophones and Application to Ultrasonic Field Measurement (2차원 배열 수중청음기의 제작과 초음파 음장 측정에의 응용)

  • Ha, Kang-Lyeol;Kim, Moo-Joon;Kang, Gab-Joong;Hyun, Byung-Gook;Chae, Min-Ku;Imano, Gazuhiko
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.5
    • /
    • pp.320-328
    • /
    • 2001
  • Two-dimensional array hydrophones with $8{\times}8$ elements were designed and fabricated using the PVDF(Polyvinylidene fluoride) piezoelectric film, and the method and system for ultrasonic field measurement in several MHz $\sim$ tens of MHz band using the hydrophones was established. The characteristics of frequency response relating to the backing materials were analyzed with the Mason equivalent circuit for design, and the accuracy of ultrasonic field measurement relating to the sizes and kerfs of piezoelectric elements was discussed. Good results of the measurement of ultrasonic field formed by a circular plane transducer of 2.25MHz in water were obtained by the system with the array hydrophones.

  • PDF

Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions

  • Jiang, Tingting;Lee, Sang-Mi;Hou, Yanan;Chang, Xin;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.46 no.3
    • /
    • pp.129-136
    • /
    • 2016
  • Objective: To investigate the dimensional accuracy of digital dental models obtained from the dental cone-beam computed tomography (CBCT) scan of alginate impressions according to the time elapse when the impressions are stored under ambient conditions. Methods: Alginate impressions were obtained from 20 adults using 3 different alginate materials, 2 traditional alginate materials (Alginoplast and Cavex Impressional) and 1 extended-pour alginate material (Cavex ColorChange). The impressions were stored under ambient conditions, and scanned by CBCT immediately after the impressions were taken, and then at 1 hour intervals for 6 hours. After reconstructing three-dimensional digital dental models, the models were measured and the data were analyzed to determine dimensional changes according to the elapsed time. The changes within the measurement error were regarded as clinically acceptable in this study. Results: All measurements showed a decreasing tendency with an increase in the elapsed time after the impressions. Although the extended-pour alginate exhibited a less decreasing tendency than the other 2 materials, there were no statistically significant differences between the materials. Changes above the measurement error occurred between the time points of 3 and 4 hours after the impressions. Conclusions: The results of this study indicate that digital dental models can be obtained simply from a CBCT scan of alginate impressions without sending them to a remote laboratory. However, when the impressions are not stored under special conditions, they should be scanned immediately, or at least within 2 to 3 hours after the impressions are taken.

A Study on Structural Intensity Measurement of Semi-infinite Beam (반무한보의 진동 인텐시티 계측에 대한 연구)

  • 이덕영;박성태
    • Journal of KSNVE
    • /
    • v.7 no.1
    • /
    • pp.43-53
    • /
    • 1997
  • This paper investigated the practical use for measuring the structural intensity (power flow per width of cross section) in a uniform semi-infinite beam in flexural vibration. The structural intensity is obtained as a vector at a measurement point, One-dimensional structural intensity can be obtained from 4-point cross spectral measurement, or 2-point measurement on the assumption of far field. The measurement errors due to finite difference approximation and phase mismatch of accelerometers are examined. For precise measurements, it would be better to make the value of k$\delta$(wave number x space between accelerometers) between 0.5 and 1.0. Formulation of the relation between bending waves in structures and structural intensity makes it possible to separate the wave components by which one can get a state of the vibration field. Experimental results are obtained from 2- and 4-point measurement performed at 200mm (near field) and 400mm (far field) apart from excitation point in random excitation. the results are compared with the theoretical values and measured values of input power spectrum in order to verify the accuracy of structural intensity method, 2-point method is suggested as the practical structural intensity method.

  • PDF