• Title/Summary/Keyword: 2-dimensional analysis

Search Result 5,875, Processing Time 0.037 seconds

Verification of Two Dimensional Hydrodynamic Model Using Velocity Data from Aerial Photo Analysis (항공사진분석 자료를 이용한 2차원 하천흐름 해석모형의 검증)

  • Seo, Il Won;Kim, Sung Eun;Minoura, Yasuhisa;Ishikawa, Tadaharu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.6B
    • /
    • pp.515-522
    • /
    • 2011
  • The hydrodynamic models are widely used in the research for analysis of flow characteristics and design of hydraulic structure and river channel. These models need to be calibrated with observed data. But, there are few field data of two-dimensional flow velocity in flood because the direct measurement of the flood flow velocity are very dangerous. For this reason the results of two-dimensional numerical models are usually calibrated and verified with only a few observed data. Moreover, the verification of numerical models for the design flood is usually carried out using the result of one-dimensional model, HEC-RAS. In this study, using the flow velocity profile extracted from the aerial photos of a flood of the Tone River in Japan, two-dimensional numerical models, RAM2 in RAMS, RMA2 in SMS, and one-dimensional numerical model, HEC-RAS which are most widely used in research and design work are verified and the validity for verification of two-dimensional models with HEC-RAS is reviewed. The results showed that the water surface elevation of HEC-RAS, RAM2 and RMA2 models have similar results with observed data. But, the velocity results of RAM2 and RMA2 models in the floodplain have some difference with the velocity from aerial photo analysis. And the velocity result of HEC-RAS has big difference with the sectional averaged value of velocity from aerial photo analysis.

Design and Analysis of 2-Dimensional Near-Field Focusing Plates Lens (근거리에서의 2차원 전계 집속 평판 렌즈 설계 및 해석)

  • Kim, Young-Guk;Lim, Sung-Joon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.1037-1042
    • /
    • 2011
  • Since J.B.Pendry proposed the concept of "perfect lens" there have been many researches which focus electric fields. However they used 1 dimensional lens. In contrast, this paper suggests 2 dimensional lens calculated from angular-spectrum method. 2-dimensional focusing is achieved in nearfield. This result implies that the proposed lens can be used for wireless power transfer, imaging system, and sensing systems.

Two-Dimensional Correlation Analysis of Sum-Frequency Vibrational Spectra of Langmuir Monolayers

  • Lee, Jonggwan;Sung, Woongmo;Kim, Doseok
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.558-563
    • /
    • 2014
  • Sum-frequency generation spectra of a Langmuir monolayer on water surface at varying surface areas were studied with two-dimensional correlation analysis. Upon enlarging the area/molecule of the Langmuir monolayer, the sum-frequency spectra changed reflecting the conformation change of the alkyl chains of the molecules in the monolayer. These changes stood out more clearly by employing two-dimensional correlation analysis of the above sum-frequency spectra. Features not very pronounced in the original spectra such as closely-spaced spectral bands can also be easily distinguished in the two-dimensional correlation spectra.

Dimensional Characteristics of Impeller Output Using 3D Printers (3D 프린터를 이용한 임펠러 출력물의 치수 특성)

  • Kong, Jeong-Ri;Kim, Hae-Ji
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.9
    • /
    • pp.56-62
    • /
    • 2022
  • This study analyzed the output precision of 3D printing methods. The inner impeller of the centrifugal compressor was printed in as a sheet with 100% packing density using two methods: field deposition modelling and stereolithography. Dimensional differences between the initial CAD and printed models were evaluated using a 3D scanner. To investigate the dimensional characteristics of the 3D printed impeller, 3D dimension analysis and point dimension analysis were performed. The point dimension analysis was divided into 3D and 2D for comparative analysis.

Design and analysis of two-dimensional binary phase masks for the fabrication of two-and three-dimensional periodic structures (2차원 및 3차원의 주기적인 구조 제작을 위한 2차원 이진 위상마스크의 설계와 분석)

  • 김남식;원영희;고근하;조두진
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.1
    • /
    • pp.17-24
    • /
    • 2001
  • Two-dimensional binary-phase diffraction gratings which can be employed to fabricate two- and three-dimensional periodic structures are designed and analyzed using rigorous coupled-wave analysis. These gratings serve as phase-masks which generate several diffracted waves from a normally incident beam and thus can produce a periodic interference pattern in space via nearfield holography. The properties of the diffracted beams can be controlled by varying the polarization and wavelength of the incident beam, surface-profile, groove depth and duty cycle of the mask. For the two-dimensional structure, optimum results can be obtained when the diffraction efficiency of the zero-order beam is minimized while that of the first-order maximized. On the other hand, when the diffraction efficiency of the zero-order is appreciable or even greater than other orders, we can obtain a variety of three-dimensional interference patterns which may be used to fabricate photonic crystals of tetragonal-body-centered and hexagonal structures in a submicron scale. scale.

  • PDF

Application of Simulated Three Dimensional CT Image in Orthognathic Surgery (악교정 수술에서 모의 조종된 3차원 전산화 단층촬영상의 응용)

  • Kim Hyung-Don;Yoo Sun-Kook;Lee Kyoung-Sang;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.363-385
    • /
    • 1998
  • In orthodontics and orthognathic surgery. cephalogram has been routine practice in diagnosis and treatment evaluation of craniofacial deformity. But its inherent distortion of actual length and angles during projecting three dimensional object to two dimensional plane might cause errors in quantitative analysis of shape and size. Therefore, it is desirable that three dimensional object is diagnosed and evaluated three dimensionally and three dimensional CT image is best for three dimensional analysis. Development of clinic necessitates evaluation of result of treatment and comparison before and after surgery. It is desirable that patient that was diagnosed and planned by three dimensional computed tomography before surgery is evaluated by three dimensional computed tomography after surgery. too. But Because there is no standardized normal values in three dimension now and three dimensional Computed Tomography needs expensive equipments and because of its expenses and amount of exposure to radiation. limitations still remain to be solved in its application to routine practice. If postoperative three dimensional image is constructed by pre and postoperative lateral and postero-anterior cephalograms and preoperative three dimensional computed tomogram. pre and postoperative image will be compared and evaluated three dimensionally without three dimensional computed tomography after surgery and that will contribute to standardize normal values in three dimension. This study introduced new method that computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms. and for validation of new method. in four cases of dry skull that position of mandible was displaced and four patients of orthognathic surgery. computer-simulated three dimensional image and actual postoperative three dimensional image were compared. The results were as follows. 1. In four cases of dry skull that position of mandible was displaced. range of displacement between computer-simulated three dimensional images and actual postoperative three dimensional images in co-ordinates values was from -1.8 mm to 1.8 mm and 94% in displacement of all co-ordinates values was from -1.0 mm to 1.0 mm and no significant difference between computer-simulated three dimensional images and actual postoperative three dimensional images was noticed(p>0.05). 2. In four cases of orthognathic surgery patients, range of displacement between computer­simulated three dimensional images and actual postoperative three dimensional images in coordinates values was from -6.7 mm to 7.7 mm and 90% in displacement of all co-ordinates values was from -4.0 to 4.0 mm and no significant difference between computer-simulated three dimensional images and actual postoperative three dimensional images was noticed(p>0.05). Conclusively. computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms. Therefore. potentiality that can construct postoperative three dimensional image without three dimensional computed tomography after surgery was presented.

  • PDF

Three Dimensional Gait Analysis of Normal Adults with Electrogoniometer Domotion (3차원 관절 전기측각기를 이용한 정상성인의 보행분석결과)

  • Choi, Jong Woo;Kim, Sei Joo;Seo, Kwan Sik;Ko, Sung Bum;Yoon, Joon Shik
    • Annals of Clinical Neurophysiology
    • /
    • v.5 no.2
    • /
    • pp.197-201
    • /
    • 2003
  • Background: The aim of this study is to present the basic reference data of kinematic gait analysis of normal Korean adults with 3 dimensional electrogoniometer, $Domotion^{(R)}$. Method: The basic kinematic gait parameters of hip, knee and ankle joints on the sagittal plane were obtained from 10 healthy adults with 5 repetition for each. Three-dimensional gait analysis was performed with $Domotion^{(R)}$ electrogoniometer in 10 meters long flat floor. Each data collected was processed with IBM PC equipped with gait analysis program. Results: Mean maximal hip flexion was $23.05^{\circ}{\pm}4.62^{\circ}$and mean maximal hip extension was $6.46^{\circ}{\pm}1.30^{\circ}$. Knee flexion was observed with two peak values. The first peak knee flexion was $6.50^{\circ}{\pm}2.07^{\circ}$ at 20.4% of gait cycle and the second peak flexion was $50.34^{\circ}{\pm}2.23^{\circ}$ at 75.8% of gait cycle. Mean maximum ankle dorsiflexion was $5.57^{\circ}{\pm}1.19^{\circ}$ at 44% of gait cycle and mean maximum ankle plantar flexion was $15.51^{\circ}{\pm}1.73^{\circ}$ at 68.5% of gait cycle. Conclusion: We concluded three dimensional gait analysis with electrogoniometer $Domotion^{(R)}$ offers a valid and reliable kinematic data and the application of this tools for clinical gait evaluation will be helpful in management of pathological gait.

  • PDF

Three-dimensional Rotordynamic Analysis Considering Bearing Support Effects (베어링 지지 효과를 고려한 3차원 로터동역학 해석)

  • Park, Hyo-Keun;Kim, Dong-Man;Kim, Yu-Sung;Kim, Myung-Kuk;Chen, Seung-Bae;Kim, Dong-Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.2 s.119
    • /
    • pp.105-113
    • /
    • 2007
  • In this study, three-dimensional rotordynamic analyses have been conducted using equivalent beam, hybrid and full three-dimensional models. The present computational method is based on the general finite element method with rotating gyroscopic effects of the rotor system. General purpose commercial finite element code, SAMCEF which includes practical rotordynamics module with various types of rotor analysis tools and bearing elements is applied. For the purpose of numerical verification, comparison study for a benchmark rotor model with support bearings is performed first. Detailed finite element models based on three different modeling concepts are constructed and then computational analyses are conducted for the realistic and complex three-dimensional rotor system. The results for rotor stability and mass unbalance response are presented and compared with the experimental vibration test data conducted herein.

Classification Technique for Ultrasonic Weld Inspection Signals using a Neural Network based on 2-dimensional fourier Transform and Principle Component Analysis (2차원 푸리에변환과 주성분분석을 기반한 초음파 용접검사의 신호분류기법)

  • Kim, Jae-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.6
    • /
    • pp.590-596
    • /
    • 2004
  • Neural network-based signal classification systems are increasingly used in the analysis of large volumes of data obtained in NDE applications. Ultrasonic inspection methods on the other hand are commonly used in the nondestructive evaluation of welds to detect flaws. An important characteristic of ultrasonic inspection is the ability to identify the type of discontinuity that gives rise to a peculiar signal. Standard techniques rely on differences in individual A-scans to classify the signals. This paper proposes an ultrasonic signal classification technique based on the information tying in the neighboring signals. The approach is based on a 2-dimensional Fourier transform and the principal component analysis to generate a reduced dimensional feature vector for classification. Results of applying the technique to data obtained from the inspection of actual steel welds are presented.

Discharge Characteristic Analysis with a Ramp Reset Waveform Using 2-Dimensional Simulation in the PDP (AC PDP에서 2차원 수치해석을 이용한 Ramp Reset 구동파형에 따른 방전 특성 분석)

  • Park, Suk-Jae;Choi, Hoon Young;Seo, Jeong-Hyun;Lee, Seok-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.192-194
    • /
    • 2003
  • In this paper, we present a 2-Dimensional simulation model of the discharge in an ac plasma display panel cell. Therefore, we study a ramp reset waveform in an ac plasma display panel discharge cell using 2-Dimensional simulation. Finally We research a connection between priming particles' density and stability.

  • PDF