• Title/Summary/Keyword: 2-Phase Induction Motor

Search Result 196, Processing Time 0.023 seconds

Analysis on the Operation Characteristics of Induction Motor Operated by Asymmetric Unbalanced Voltage (비대칭 불평형 전압 운전시 유도전동기의 동작 특성 해석)

  • Kim, Jong-Gyeum;Sohn, Hong-Kwan;Jeong, Jong-Ho;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.2
    • /
    • pp.58-64
    • /
    • 2004
  • Most of the loads in industrial power distribution systems are balanced and connected to three power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating voltage unbalance. Voltage unbalance is a condition in a polyphase system in which the rms values of the line-to-line voltages or the phase angles between consecutive line-to-line voltages, are not all equal. Slight voltage unbalance generates a disproportionately high current unbalance at the motor stator winding. This paper presents a scheme on operation states of a three-phase induction motor under unbalanced voltages. The three-phase voltages applied to the stator winding of the studied induction motor are controlled by respectively adjusting the magnitude and phase angle of each phase. The voltage unbalanced factor(VUF) of the three-phase source voltages can then be varied to examine the different values of VUF on machine's operation characteristics.

Open Fault Diagnosis Method for Five-Phase Induction Motor Driving System (5상 유도전동기 구동 시스템을 위한 인버터의 개방고장진단 방법)

  • Baek, Seung-Koo;Shin, Hye-Ung;Kang, Seong-Yun;Park, Choon-Soo;Lee, Kyo-Beum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.2
    • /
    • pp.304-310
    • /
    • 2016
  • This paper proposes a fault diagnosis method for an open-fault in inverter driving five-phase induction motor. The five-phase induction motor has a high output torque and small torque ripple in comparison to three-phase. The best advantage of the five-phase induction motor is fault diagnosis and tolerant control using redundancy of phases. This paper uses an inverter as a power converter for driving a five-phase induction motor. If a switch of inverter occurs to the open-fault, this problem is the influence on the output current and output torque. To solve this problem, there is need of an accurate diagnosis and fault switch distinction. Therefore, this paper propose a fault detection method of the open-fault switches for the fault diagnosis. First, analyzing the pattern for the open-circuit fault of one phase. next, analyzing the pattern for the open-circuit fault of each inverter switches. Through the pattern analysis, It defines the scope of each of the failure switch. Thereafter, By using an algorithm that proposes to perform a fault diagnosis method. The proposed algorithm is verified from the experiment with the 1.5 kW five-phase induction motor.

Low-Cost Current Measurement Method for Vector Control of 2-Phase Induction Motor (2상 유도전동기의 벡터제어를 위한 저가형 전류측정 방법)

  • Oh, Kwang-Ho;Yoon, Duck-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.634-638
    • /
    • 2015
  • Phase currents should be measured in real time for vector control of a 2-phase induction motor. Generally, the phase currents of the motor are measured using two Hall current sensors installed at the output terminal of an inverter. Unfortunately, Hall current sensors are expensive and uneconomical because a vector-controlled inverter for 2-phase induction motor is mainly used in low-power and low-price applications. This paper proposes a low-cost current measurement method using two shunt resistors instead of expensive Hall current sensors. The proposed method can measure the phase currents under all operating conditions of the motor. This method was applied to an experimental vector-controlled inverter for 2-phase induction motor of 220[V]/360[W] and was verified through computer simulations and experimentation.

Modified Direct Torque Control System of Five Phase Induction Motor

  • Kim, Nam-Hun;Kim, Min-Huei
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.266-271
    • /
    • 2009
  • In this paper, improved direct torque control(DTC) of five-phase induction motor(IM) is proposed. Due to the additional degrees of freedom, five-phase IM drives present unique characteristics. One of them is the ability of enhancing the torque producing capability of the motor. Also five-phase motor drives possess many others advantage compared with the traditional three-phase motor drives. Such as, reducing the amplitude and increasing of frequency of torque pulsation, reducing amplitude of current per phase without increasing the voltage per phase and increasing the reliability. The direct torque control method is advantageous when it is applied to the five-phase IM. Because the five-phase inverter provides 32 space vectors in comparison to 8 space voltage vectors by the three-phase inverter. The 32 space voltage vectors are divided into three groups according to their magnitudes. The characteristics and dynamic performance of traditional five-phase DTC are analyzed and new DTC for five-phase IM is proposed. Therefore, a more precise flux and torque control algorithm for the five-phase IM drives can be suggested and explained. For presenting the superior performance of the pro-posed direct torque control, experimental results is presented using a 32 bit fixed point TMS320F2812 digital signal processor

Analysis of The Generating Torque Characteristics of 2-Phase lnduction Motor in Phase Control. (이상유도전동기의 립상제어시 발생토오크에 대한 해석)

  • 원종수;장도현
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.5
    • /
    • pp.289-297
    • /
    • 1988
  • In this paper, the analysis of a generating torque characteristics of 2-phase induction motor driven with the phase control method is presented. The generating torque equations which represent average torque and pulsating torque are derived from the elementary machine model. The calculating equations which can get the values of average torque and pulsating torque is expressed by the parameters of the equivalent circuit of 2-phase induction motor. According to the calculating equations, these performance characteristics are investigated under various conditions. Finally, a strategy to eliminate non-linearity and pulsating torque generated in driving 2-phase induction motor with the phase control method is presented.

  • PDF

A Study on the Digital Control of Single Phase Induction Motor Driven by the Full Bridge Resonant Inverter(2) (전브리지 공진형 인버터에 의한 단상 유도전동기의 디지탈 제어에 관한 연구(2))

  • 노영오;박진길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.5
    • /
    • pp.86-98
    • /
    • 1993
  • The application of A.C. motor for servo system is rapidly increased according to the recent advance of power electronics and digital control techniques. The induction motor which has a simple structure and needs less maintenance has become to be used widely in the industrial field for the speed and position control recently. In this paper, the full-bridge resonant inverter is applied to the speed control of single phase inducting motor. The digital PID control algorithm is used and the control parameter is determined by the Zigler-Nichols transient response method. The speed control is carried out by the one chip micro-processor(intel EV 8097BH) and control program is developed by the assembly language. By the experimental result, it is confirmed that the speed of single phase induction motor driven by full bridge series inverter can be smoothly controlled by a digital PID controller.

  • PDF

Vector Control for Two-Phase Inverter-Fed Two-Phase Induction Motors (2상 유도전동기 구동 2상 인버터의 벡터 제어)

  • Jang, Do-Hyun;Cho, Young-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.310-317
    • /
    • 2007
  • In this paper, the system equation for the balanced two-phase induction motor is derived and the characteristics for speed control is also analyzed in the region of constant torque and constant power. The modified vector control theory is applied to two-phase motor drive system. The speed of two-phase motor drive can be controlled precisely by the modified indirect vector control theory. The modified vector control theory is simpler comparing to the conventional vector control because of the simpler axis transformation. The computer simulations and the experimental results presented to confirm the vector control for two-phase inverter fed two phase induction motor system.

The Study of the Stray Load Loss and Mechanical Loss of Three Phase Induction Motor considering Experimental Results

  • Kim, Dong-Jun;Choi, Jae-Hak;Chun, Yon-Do;Koo, Dae-Hyun;Han, Pil-Wan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.121-126
    • /
    • 2014
  • The accurate determination of induction motor efficiency depends on the estimation of the five losses of stator and rotor copper loss, iron loss, mechanical loss and stray load loss. As the mechanical and stray load losses are not calculated by electro-magnetic analysis, the values of these two losses are very important in induction motor design. In this paper, the values of mechanical loss and stray load loss are proposed through investigating testing data from commercial products of three phase induction motors under 37kW. If the values of this paper are applied to motor design, the accuracy of design and analysis can be improved. The losses of motors are obtained by using load and no-load test results following IEC 60034-2-1 standard.

FEA & Topology Optimization of Single-Phase Induction Motor for Rotary Compressor (로터리 컴프레서용 단상 유도모터의 유한요소해석 및 위상 최적설계)

  • Wang, Se-Myung;Kang, Je-Nam
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.7
    • /
    • pp.351-356
    • /
    • 2002
  • The oil circulation rate (OCR) of the rotary compressor is a crucial factor affecting the performance and reliability of air-conditioning systems. In this paper, topology optimization of the single-phase induction motor of rotary compressor is carried out for reducing the OCR. The nonlinear transient characteristic of single-phase induction motor for rotary compressor is analyzed by using FLUX2D. The topology optimization for electromagnetic systems is developed using the finite element method (FEM). The topology optimization is applied to a single-phase induction motor for reducing the OCR. For validation, optimize induction motors are manufactured and tested.

A Study on the Performance Improvement of Rotor Structure Modifications in Single-Phase Motors for Compressor Applications (압축기용 단상 전동기의 회전자 자계구조 변경에 따른 성능에 관한 연구)

  • Tae-Uk Jung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.2_2
    • /
    • pp.325-332
    • /
    • 2024
  • Contemporary power systems demand efficient and sustainable technologies. Single-phase induction motors, while widely used, face efficiency challenges due to inherent rotor losses. Proposed solutions include the Line-start Permanent Magnet Synchronous Motor (LSPMSM), leveraging permanent magnets for enhanced energy density but facing demagnetization and cost issues. Alternatively, the Line-start Synchronous Reluctance Motor (LSRM) operates as a hybrid motor without permanent magnets, reducing rotor losses and potentially improving efficiency. This paper focuses on designing an LSRM rotor for air conditioner compressors, analyzing start-up characteristics and efficiency through finite element analysis. A comparative study with single-phase induction motors provides insights for future motor technology selection, balancing efficiency and other requirements.