• 제목/요약/키워드: 2-D numerical analysis

검색결과 1,634건 처리시간 0.04초

Comparative Analysis of Spontaneous Infectious Spondylitis : Pyogenic versus Tuberculous

  • Lee, Yangwon;Kim, Bum-Joon;Kim, Se-Hoon;Lee, Seung-Hwan;Kim, Won-Hyung;Jin, Sung-Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권1호
    • /
    • pp.81-88
    • /
    • 2018
  • Objective : Spondylitis is often chemotherapy resistant and requires long-term treatment. Without adequate chemotherapy, the outcome can be fatal or result in severe neurologic damage. Therefore, differentiating the etiology of spondylitis is very important, particularly in spontaneous cases. As the prevalence of tuberculosis in Korea has decreased in recent years, updated clinical research about spondylitis is warranted. Methods : From April 2010 to March 2016, data from spondylitis patients were collected retrospectively. In total, 69 patients (51 with pyogenic spondylitis and 18 with tuberculous spondylitis) were included. Clinical data, laboratory findings including erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP) level, measurements of Cobb angles at the initial and final follow-up, and radiologic features on magnetic resonance imaging (MRI) scans were evaluated. To test differences between the pyogenic and tuberculous groups, numerical data were compared using the student's t-test and Mann-Whitney U test, and categorical data were compared using the chi-square test and Fisher's exact test. Results : The patients' mean age was 60.0 years. Male sex was slightly predominant (56.5%). There was no difference in mean age and sex between the two groups. The pyogenic group had a relatively higher proportion of immunocompromised patients. The peak CRP value was higher in the pyogenic group than in the tuberculous group (14.08 mg/dL and 8.50 mg/dL, respectively, p=0.009), whereas the ESR was not significantly different between the groups (81.5 mm/h and 75.6 mm/h, respectively, p=0.442). Radiologically, the presence of disc space sparing and vertebral body collapse differed between the groups. In the tuberculous group, the disc was more commonly preserved on contrast-enhanced MRI (50% and 23.5%, respectively, p=0.044), and vertebral body collapse was more common (66.6% and 15.7%, respectively, p<0.001). The mean length of hospitalization was longer in the pyogenic group (56.5 days and 41.2 days, respectively, p=0.001). Four mortality cases were observed only in the pyogenic group. The most commonly isolated microorganism in the pyogenic group was Staphylococcus aureus(S. aureus) (methicillin susceptible S. aureus and methicillin resistant S. aureus [MRSA] in 8 and 4 cases, respectively). Conclusion : The clinical and radiological manifestations of spontaneous spondylitis differ based on the causative organism. Pyogenic spondylitis patients tend to have a higher CRP level and a more severe clinical course, whereas tuberculous spondylitis patients present with destruction of the vertebral body with disc sparing more frequently. The presence of MRSA is increasing in community-acquired spondylitis cases.

전자기 수치 해석을 이용한 Combo 표준 보정 시험편의 MRPC Probe 와전류 신호 모사 및 평가 (Simulation and Evaluation of ECT Signals From MRPC Probe in Combo Calibration Standard Tube Using Electromagnetic Numerical Analysis)

  • 유주영;송성진;정희준;공영배
    • 비파괴검사학회지
    • /
    • 제26권2호
    • /
    • pp.90-98
    • /
    • 2006
  • 원전 증기 발생기 세관의 MRPC probe 신호를 검사하고 평가하기 위해서는 일반적으로 Combo 표준 보정 시험편 신호가 신호 보정을 위해 사용된다 이렇듯 Combo 표준 보정 시험편 신호는 신호 평가에 중요한 영향을 미치지만, probe 상태나 관 주위의 여러 요소에 의해 쉽게 영향을 받기 때문에 결함 평가 요소인 신호의 크기 값과 위상각을 왜곡시킬 수 있다. 따라서 본 연구는 이런 문제점을 극복하기 위해 Combo 표준 보정 시험편의 실제 신호를 모사 신호로 대체하는 가능성을 알아보기 위해 실험을 해 보았다 이를 위해 MRPC probe와 Combo 표준 보정 시험편의 특성을 조사하였으며 계산 수행을 위해 체적 적분 방법으로 계산되는 상용 전자기 해석 프로그램인 VIC-3D를 사용하였고 모사 신호를 생성한 후 실험 신호와 비교를 통해 신호의 정확성을 확인하였다. 마지막으로, 모사 신호를 이용한 결함 평가를 위하여 실제 결함과 가공 결함에 대해 위상각과 크기 값의 항목으로 평가하여 실제 결함 평가자에 의한 결과와 비교하였다.

p-수렴 경계요소법에 의한 L-형 영역을 갖는 2차원 포텐셜 문제 해석 (Analysis of 2-D Potential Problem with L-shape Domain by p-Convergent Boundary Element Method)

  • 우광성;조준형
    • 한국전산구조공학회논문집
    • /
    • 제22권1호
    • /
    • pp.117-124
    • /
    • 2009
  • 2차원 포텐셜 문제를 해석하기 위해 고차의 르장드르 형상함수에 기초를 둔 p-수렴 경계요소법이 제안되었다. p-수렴 경계요소법은 종래의 경계요소법에서 사용되는 형상함수와 성질이 다른 르장드르 다항식을 형상함수로 사용한다. p-수렴 유한요소법과 마찬가지로 고차의 형상함수에 따른 절점의 위치가 경계상에서 정해지지 않는다. 따라서 형상함수가 증가함에 따라 선형방정식을 구성하기 위한 수단으로 선점법을 이용하였다. p-수렴 경계요소법에서 선점법은 비대칭 계층적 선점법과 대칭 비계층적 선점법을 선택하여 수치해석을 수행하였다. 선택점들은 형상함수가 증가함에 따라 증가하는 성질을 나타내며 계층적 또는 대칭적으로 선택될 수 있다. p-수렴 경계요소법에서 나타나는 특이 적분항을 계산하기 위해 special numeric quadrature technique와 semi-analytical integration technique를 사용하였다. 사각모서리부에서 특이성을 가지는 L-형 영역문제를 해석한 결과 적은 수의 자유도에서 기존문헌의 결과와 차이가 거의 없는 정도인 $10^{-2}%$단위 이하의 정확도를 보여주었다. 또한 같은 조건에서는 대칭형 선점의 위치를 이용해 계산한 값이 가장 높은 정확도를 보여주었다.

2차원 부정류 모형을 이용한 둔치의 수리특성 분석 (Analysis of Hydraulic Characteristics of Flood Plain Using Two-Dimensional Unsteady Model)

  • 구영훈;송창근;김영도;서일원
    • 대한토목학회논문집
    • /
    • 제33권3호
    • /
    • pp.997-1005
    • /
    • 2013
  • 낙동강의 횡단면은 복단면 형태를 띄고 있으므로, 여름철 집중호우에 의해서 하천유량이 증가하면 둔치 상부까지 하천수위가 상승하는 특징이 있다. 또한 최근 강우강도 및 홍수 빈도의 증가로 인해 관련 피해가 급증하고 있으며, 이는 홍수터에 설치된 공원과 같은 친수시설들의 침수피해와 직접적으로 연관되므로, 극한강우 시 둔치에서의 수리학적 영향분석이 필요하다고 판단된다. 본 연구에서는 다양한 친수시설들이 조성되어 있는 강정고령보와 달성보 사이를 모의구간으로 선정하여 태풍 산바에 의해 첨두홍수량이 발생한 시점을 전후로 총 42시간에 걸친 수치모의를 실시하였다. 2차원 부정류 모형인 FaSTMECH 모의결과와 수위관측소에서 실측된 실측수위와 비교하여 모형의 적용성을 검토한 결과 $R^2$는 0.990, AME는 0.195, RMSE는 0.252로 높은 상관관계를 보였다. 그리고 검증된 FaSTMECH 모형을 이용하여 태풍 사상 시 홍수터 내에 위치해 있는 캠핑장과 생태공원 등과 같은 친수시설이 침수되는 시간 및 침수심, 침수 유속 및 전단력 등을 분석하였다.

Analysis of the Climate inside Multi-span Plastic Greenhouses under Different Shade Strategies and Wind Regimes

  • He, Keshi;Chen, Dayue;Sun, Lijuan;Huang, Zhenyu;Liu, Zhenglu
    • 원예과학기술지
    • /
    • 제32권4호
    • /
    • pp.473-483
    • /
    • 2014
  • In this work, the effects of shade combination, shade height and wind regime on greenhouse climate were quantified. A two-dimensional (2-D) computational fluid dynamics (CFD) model was developed based on an 11-span plastic greenhouse in eastern China for wind almost normal to the greenhouse orientation. The model was first validated with air temperature profiles measured in a compartmentalized greenhouse cultivated with mature lettuce (Lactuca sativa L., 'Yang Shan'). Next, the model was employed to investigate the effect of shade combinations on greenhouse microclimate patterns. Simulations showed similar airflow patterns in the greenhouse under different shade combinations. The temperature pattern was a consequence of convection and radiation transfer and was not significantly influenced by shade combination. The use of shade screens reduced air velocity by $0.02-0.20m{\cdot}s^{-1}$, lowered air temperature by $0.2-0.8^{\circ}C$ and raised the humidity level by 0.9-2.0% in the greenhouse. Moreover, it improved the interior climate homogeneity. The assessment of shade performance revealed that the external shade had good cooling and homogeneity performance and thus can be recommended. Furthermore, the effects of external shade height and wind regime on greenhouse climate parameters showed that external shade screens are suitable for installation within 1 m above roof level. They also demonstrated that, under external shade conditions, greenhouse temperature was reduced relative to unshaded conditions by $1.3^{\circ}C$ under a wind speed of $0.5m{\cdot}s^{-1}$, whereas it was reduced by merely $0.5^{\circ}C$ under a wind speed of $2.0m{\cdot}s^{-1}$. Therefore, external shading is more useful during periods of low wind speed.

개별요소해석법을 이용한 지오그리드 격자 크기와 도상자갈재료 입도분포 상관관계 평가 (Evaluation of the Relationship between Geogrid Rib Size and Particle Size Distribution of Ballast Materials using Discrete Element Method)

  • 피지현;오정호
    • 대한토목학회논문집
    • /
    • 제36권1호
    • /
    • pp.143-149
    • /
    • 2016
  • 본 연구에서는 지오그리드로 보강된 자갈도상재료들의 전단거동을 대형직접전단시험과 개별요소법을 기반으로 한 PFC 3D프로그램을 사용하여 검토하였다. 직접전단시험은 각기 다른 입도분포를 갖는 자갈도상에 대해 실험을 수행 하였다. 실험 결과, 지오그리드로 보강되지 않은 경우 입경이 큰 입자가 많은 입도분포를 갖는 재료의 전단강도가 증가함을 확인한 반면, 지오그리드로 보강된 경우에는 전단강도 변화가 지오그리드 입자 크기와 입도분포에 따라서 증가 혹은 감소하는 경향을 보였다. 개별요소수치해석을 통해서 실험 결과를 검증하고자 하였으며 이를 위해서 실제 사용된 지오그리드 인장강도를 갖도록 미시 물성치를 민감도 분석을 통해 확보 하였으며, 각기 다른 격자 크기를 가진 지오그리드에 동일하게 적용하여 도상재료 입도분포에 따른 상관관계를 비교하여 보았다. 해석결과 입도분포에 따라 적합한 보강효과를 보이기 위해서는 그에 적합한 지오그리드의 격자크기가 형성됨을 확인하였으며, 평균입자크기에 비해 최소 2배 이상의 격자크기가 확보되어야 하는 것으로 확인하였다. 지오그리드의 영향범위가 일정한 깊이 내에 형성되는 것을 확인하였다.

저궤도 관측위성 임무계획(Mission Planning)을 위한 기상수치예보 GRIB Data 분석 (Analysis of NWP GRIB Data for LEO Satellite Mission Planning)

  • 서정수;서석배;배희진;김은규
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 춘계학술대회 논문집
    • /
    • pp.178-186
    • /
    • 2006
  • 기상 수치예보는 (Numerical Weather Pridiction, NWP)는 바람, 기온, 등과 같은 기상요소의 시간 변화를 나타내는 물리방정식을 컴퓨터로 풀어 미래의 대기 상태를 예상하는 과학적인 방법으로 지구를 상세한 격자 2진부호(GRIdded Binary, 이하 GRIB)로 나누어 그 격자점에서의 값으로 대기 상태를 나타낸다. 지구 각지에서의 각종 관측자료를 기초로 격자점상의 현재값을 구한다. 대용량의 격자데이터는 이진형태이어서 컴퓨터, 서버 저장장치에서 동일형태 데이터로 존재한다. 우리나라 최초의 저궤도 관측 위성인 다목적 실용위성 KOMPSAT-1호(이하, 아리랑 위성1호)는 전자광학카메라(Electro Optical Camera, EOC)를 탑재하여 1999년 12월 21일에 발사된 이후 2006년 1월 현재까지 6여년간 성공적으로 임무를 수행, 7049여회의 영상을 획득하여 국가적으로 귀중한 자료로 활용하고 있다. 아리랑 위성1호는 일일 2-3회 EOC영상을 획득하고 있으며, 임무계획(Mission Planning)은 MP(Mission Planner)가 사용자로부터 자료를 수집하여 임무분석 및 계획 서브시스템(MAPS)에 의해 계산되어진 위성의 제도예측 데이터에 촬영하고자하는 목표지점 좌표를 입력하여 자동명령생성기(KSCG)에 의해 계산된 촬영 경사각도(Tilt)값을 위성에 전송하여 목표지역의 영상을 획득하게 된다. 위성영상 획득에 있어 고가의 위성을 운영하면서 기상의 상태를 정확히 예측하여 실패없이 유효한 영상을 획득하는 것이 무엇보다 중요하다. 본 논문에서는 효율적인 위성임무계획을 위한 기상수치예보 자료를 분석하여 앞으로 발사하게 될 고해상 카메라 탑제위성인 아리랑 위성2호와 3호에 적용하고자 한다. the sufficient excess reactivity to override this poisoning must be inserted, or its concentration is decreased sufficiently when its temporary shutdown is required. As ratter of fact, these have an important influence not only on reactor safety but also on economic aspect in operation. Considering these points in this study, the shutdown process was cptimized using the Pontryagin's maximum principle so that the shutdown mirth[d was improved as to restart the reactor to its fulpower at any time, but the xenon concentration did not excess the constrained allowable value during and after shutdown, at the same time all the control actions were completed within minimum time from beginning of the shutdown.및 12.36%, $101{\sim}200$일의 경우 12.78% 및 12.44%, 201일 이상의 경우 13.17% 및 11.30%로 201일 이상의 유기의 경우에만 대조구와 삭제 구간에 유의적인(p<0.05) 차이를 나타내었다.는 담수(淡水)에서 10%o의 해수(海水)

  • PDF

자폐장애 환자의 세포유전학적 분석 (CYTOGENETIC ANALYSIS OF CHILDREN WITH AUTISM)

  • 정철호;이제영;박영남;박종한;김정범;김재룡;전효진
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • 제5권1호
    • /
    • pp.108-117
    • /
    • 1994
  • 자폐장애와 fragile X증후군의 관련성과 자폐장애 환자에서 특이한 염색체 이상유무를 알고자 자폐장애 환자 29명을 대상으로 하고 질병대조군으로 정신지체 환자 30명을 대상으로 하여, 1) PHA 자극 말초혈 임파구의 G분염에 의한 상용 염색체검사를 실시하여 염색체 이상 유무를 확인하고, 2) MTX를 함유한 배지에서 fragile site 분석을 각각 실시하였다. 연구결과 G 분염에 의한 상용 염색체검사에서는 자폐장애군과 정신지체군에서 모두 46XX 혹은 46XY로서 정상 핵형을 보였으며, fragile site 분석결과에서 fra X(q27.3)은 두 군 모두에서 한 명도 발견되지 않았다. Fragile X 이외의 염색체 이상을 보인 예는 자폐장애군 11명(37.9%), 정신지체군에서 10명(33.3%) 발견되었으나 자폐장애군과 정신지체군 상호간에 유의성 있는 차이는 발견할 수 없었으며, fragile site와 gap이 A, B, C, D, E군에서 다양하게 분포되어 있어 의미있는 분절 부위는 없었다. Fragile site가 관찰된 세포의 수는 자폐장애군에서 31개로 관찰한 모든 중기 세포의 3.6%에 해당하였고 정신지체군에서 29개, 3.2%가 발견되었으며 gap이 관찰된 세포의 수는 자폐장애군에서 43개로 관찰한 모든 중기세포의 4.9%에 해당하였고 정신지체군에서 35개, 3.9%가 발견되었다. 이상의 결과에서, 본 연구에서 조사대상으로 한 자폐장애군에서는 fragile(X)(q27.3)가 한 예에서도 관찰되지 않아, fragile X 증후군에 의한 자폐장애는 매우 드물 것으로 생각되며, fragile X증후군을 자폐장애의 직접적인 원인으로는 생각하기 힘들다. 그리고 자폐장에 환자에서 관찰되는 fragile site와 gap은 정신지체군에서도 비슷한 빈도 및 양상으로 관찰되는 바 자폐장애 환자의 특이한 소견은 아니었다.

  • PDF

터널 화재 시 열부력을 고려한 제연용 제트팬 용량산정에 관한 기초 연구 (A fundamental study on the jet fan capacity for smoke control considering thermal buoyancy force in tunnel fires)

  • 이호형;최판규;조종복;이승철;이창우
    • 한국터널지하공간학회 논문집
    • /
    • 제20권2호
    • /
    • pp.501-511
    • /
    • 2018
  • 최근 '도로터널 방재시설 설치 및 관리지침'의 개정으로 인해 터널 내 제연용 제트팬의 용량 산정 시에는 열부력을 고려하도록 규정하고 있다. 그러나 열부력을 고려하는 세부방법론에 대한 규정이 없어, 이에 대한 세부적인 추가 연구가 필요한 실정이다. 본 연구에서는 터널 내 화재 시 열부력을 고려하기 위하여 3차원 수치해석 시뮬레이션을 수행하여 터널 내열부력을 계산하고, 화재차량의 진행방향에 따라 열부력과 차량항력의 관계, 즉, 화재차량의 위치에 따른 터널 내 제연용 제트팬 용량 산정방법에 대하여 검토를 수행하였다. 분석결과에 따르면, 하향경사 터널의 경우에는 열부력이 터널 내 저항력으로 작용하며, 터널 내 화재연기를 제연하기 위해 필요한 제연팬의 승압력은 단순히 터널 입구부의 열부력 값과 출구부의 차량항력값에 의해 단순히 결정되지 않으며, 터널 내 화재차량의 위치에 따라 종합적인 검토가 필요한 것으로 분석되었다.

3차원 수치모의를 이용한 보 접속부 세굴 특성 분석 (Analysis of Characteristics for Bank Scour around Low Dam using 3D Numerical Simulation)

  • 정석일;여창건;윤광석;이승오
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2011년도 정기 학술발표대회
    • /
    • pp.102-102
    • /
    • 2011
  • 보는 하천에서 취수나 하상유지를 위한 하천횡단구조물로 일반적으로 본체, 물받이, 바닥보호공 등으로 구성되며 제방 연결부 호안 및 밑다짐 등에 대한 설계기준이 하천설계기준에 제시되어 있다. 그러나 태풍 루사나 매미에 의한 피해사례를 보면 하천 횡단 구조물 본체가 파괴되는 피해 뿐만 아니라, 구조물과 제방과의 연결부가 세굴이 발생되어 붕괴되는 사례가 많이 발생하고 있다. 하천설계기준 해설(2009)에는 이러한 보와 제방의 연결부 부분을 연결호안이라하여 관련 기준을 제시하고 있으나, 설치구간의 길이를 정할 때 하천의 규모나 하도의 특성을 고려하지 못하고 일률적으로 결정하도록 하고 있다. 이에 건설기술연구원의 '보 및 낙차공 설계기술 개발 연구보고서'(윤광석 등, 2006)에서는 고정상 실험을 통해 연결호안 설치구간에 대한 실험식을 제시하였다. 본 연구에서는 3차원 수치모의를 통하여 건설기술연구원에서 수행하였던 실험을 재현하고, 제방을 이동상으로 하여 인자들 간의 상호 관계를 밝히며, 그 특성을 분석하고자 한다. 그리고 윤광석 등(2006)에 의해 제시된 실험식에 적용하여 검증하였다. 수치모의는 유량을 $0.7{\sim}2.8m^3/sec$까지 변화하며 수행하였으며, 유사의 대표입경은 0.63mm로, 상류수심은 1.0m로 일정하게 유지하였다. 수치모의는 평형세굴 발생 후, 최소 모의시간의 10%정도 지난 시간까지 하였다. 수치모의 결과는 다음과 같다. (1) 유량이 증가함에 따라 유속 및 Froude 수가 증가하여 상 하류부 세굴 발생 범위와 폭은 증가하였다. (2) 상류는 하류에 비해 유량에 따른 세굴발생 범위가 상대적으로 작게 나타났으며, 이는 하류단에 비해 상류단의 유속 및 Froude 수의 차이가 작았기 때문인 것으로 판단된다. (3) 세굴의 폭을 측정함으로써 세굴에 가장 취약한 부분을 짐작할 수 있으며, 설계에 반영되어 호안이나 옹벽의 두께결정에 적용한다면 세굴에 대해 좀 더 안전한 설계가 될 수 있을 것이다. (4) 건설기술연구원(2006)에서 제시한 식(1)과의 비교를 통해 수치모의 결과가 식(1)로부터 계산된 값보다 작음을 알 수 있으며, 그 이유는 식(1)의 범위는 와류영역구간을 나타내서 연결호안 설치구간 길이를 제시하고 있는 반면, 본 연구의 수치모의 결과는 세굴이 발생한 범위를 제시하였기 때문이다. 향후 보 높이와 좀 더 다양한 유량에 대한 경우를 수치모의하고, 이동상 제방에 대한 실험을 통해 명확한 식을 제안 할 것이다.

  • PDF