• 제목/요약/키워드: 2-D mirror

검색결과 160건 처리시간 0.024초

Optical Design and Fabrication of a Large Telephoto Zoom Lens with Fixed f/2.8 and Light Autofocus Lens

  • Ryu, Jae Myung;Gang, Geon Mo;Lee, Hyuck Ki;Lee, Ki Woo;Heu, Min;Jo, Jae Heung
    • Journal of the Optical Society of Korea
    • /
    • 제19권6호
    • /
    • pp.629-637
    • /
    • 2015
  • Compact system cameras (CSCs) are commonly used nowadays and feature enhanced video functions and thin yet light interchangeable lenses. They differ from digital single-lens reflex (DSLR) cameras in their lack of mirror boxes. CSCs, however, have autofocus (AF) speeds lower than those of conventional DSLRs, requiring weight reduction of their AF groups. To ensure the marketability of large telephoto zoom lenses with fixed f/2.8 regardless of field angle variation, in particular, light weight AF groups are essential. In this paper, we introduce a paraxial optical design method and present a new, large, telephoto zoom lens with f/2.8 regardless of the field angle variation, plus a lightweight AF group consisting of only one lens. Using the basic paraxial optical design and optimization methods, we fabricated a new and lighter zoom lens system, including a single-lens, lightweight AF group with almost the same performance.

주얼리 3D 모델링의 이커머스 마케팅 활용연구 - 메타버스 플랫폼을 중심으로 (Study on Utilization of Jewelry 3D Modeling in E-commerce Marketing - Focusing on Metaverse Platform)

  • 강혜림
    • 문화기술의 융합
    • /
    • 제9권2호
    • /
    • pp.581-587
    • /
    • 2023
  • 글로벌 팬데믹으로 전 세계는 삶과 생존을 최우선의 가치로 방향성을 정립하고 디지털 기술을 활용한 새로운 패러다임을 만들어왔다. 언택트는 편리성의 가치를 넘어 방역과 위생 관점에서 필수적인 가치로 변하였고, 산업체 전반의 프로세스를 집체형에서 비대면으로 전환시켰다. 플랫폼은 가상공간에서 유기적인 커뮤니티를 형성하고, 기업은 실재감 기반의 새로운 서비스를 시작하였다. 현실과 유사한 환경 구축에 필요한 실재감을 위해 평면 이미지 중심의 2D에서 다면화된 3D로 정보는 표현, 저장되고 있다. 기업은 메타버스 플랫폼의 증강현실, 가상세계, 거울세계 등의 유형을 필두로 3D 모델링을 활용한 마케팅을 전개하고 있다. 이러한 변화의 시대 흐름에서 국내외 주얼리 브랜드 이커머스 환경의 3D 모델링 현황과 사례를 분석하고, 3D 모델링에 대한 주얼리 산업체의 활용 방안을 제시하는 데 본 연구의 목적이 있다.

FIMS에 사용되는 비축 포물 원통형 반사경의 제작과 성능 시험 결과 (MANUFACTURING AND TEST RESULTS OF OFF-AXIS PARABOLIC CYLINDER MIRROR FOR FIMS)

  • 유광선;육인수;선광일;이윤우;남욱원;신종호;홍소진;이대희;진호;오승한;이진근;민경욱;한원용;박장현
    • Journal of Astronomy and Space Sciences
    • /
    • 제18권3호
    • /
    • pp.239-248
    • /
    • 2001
  • 2002년에 발사 예정인 과학 위성 1호의 주 탑재체로 원자외선 분광기가 실릴 예정이다. 원자외선 분광기는 영상과 분광의 기능을 함께 수행하게 되는데, 광학 부품 중 포물 원통 만가경의 경우 천문 관측용으로는 제작된 바가 없어 제작과 이에 관련된 측정 방법을 새로이 고안하여 제작시험이 이루어 겼다. 관측 목표로부터 도출된 사양 중에서 성능과 가장 밀접한 관계가 있는 형상오차의 경우 ~ $lambda/cm$의 한계를 만족하였으며, 산란장과 연관된 표면 거칠기의 경우 새로이 고안된 비구면 pitch polishing의 방법으로 $R_{q}$의 값이 1 nm 이하로 감소하였으며, 이로써 전체 파장 영역에서 0.02, 즉 2% 미만의 빛이 산란됨을 간접적으로 확인하였다.

  • PDF

HMD(Head Mounted Display)에서 시선 추적을 통한 3차원 게임 조작 방법 연구 (A Study on Manipulating Method of 3D Game in HMD Environment by using Eye Tracking)

  • 박강령;이의철
    • 대한전자공학회논문지SP
    • /
    • 제45권2호
    • /
    • pp.49-64
    • /
    • 2008
  • 최근에 휴먼 컴퓨터 인터페이스 분야에서 사용자의 시선 위치를 파악하여 더욱 편리한 입력장치를 구축하고자 하는 연구가 많이 진행되고 있다. 하지만 복잡한 하드웨어 구성으로 제품의 가격이 매우 비싸고, 까다로운 사용자 캘리브레이션 과정으로 인해 시스템의 사용에 어려움을 겪는다. 본 논문에서는 HMD(Head Mounted Display)에 USB 카메라와 적외선을 반사시키는 hot-mirror와 적외선 조명을 이용한 시선 추적 모듈을 부착하고, 이를 통해 획득한 눈 영상의 2차원적인 분석과 간단한 사용자 캘리브레이션 과정을 통해 시선 위치를 파악하는 방법을 제안한다. HMD는 사용자의 얼굴 움직임과 함께 움직이므로, 얼굴움직임에 영향을 받지 않는 시선 추적 시스템을 구현할 수 있다. 또한, 시선 추적 시스템을 3차원 1인칭 슈팅 게임에 적응하여, 캐릭터의 시선 방향을 조정하고, 적 캐릭터를 조준하여 사격이 가능하도록 하여, 게임의 몰입감과 흥미성을 높일 수 있게 하였다. 실험 결과, 한 대의 데스크톱 컴퓨터 환경에서 게임과 시선 추적 시스템이 실시간으로 동작 가능했으며, 약 $0.88^{\circ}$의 시선 위치 추출 오차를 보였다. 또한 3차원 1인칭 슈팅게임에서 일반 마우스의 역할을 시선 추적 시스템이 문제없이 대신할 수 있음을 확인하였다.

A PLC-Based Optical Sub-assembly of Triplexer Using TFF-Attached WDM and PD Carriers

  • Han, Young-Tak;Park, Yoon-Jung;Park, Sang-Ho;Shin, Jang-Uk;Kim, Duk-Jun;Park, Chul-Hee;Park, Sung-Woong;Kwon, Yoon-Koo;Lee, Deug-Ju;Hwang, Wol-Yon;Sung, Hee-Kyung
    • ETRI Journal
    • /
    • 제28권1호
    • /
    • pp.103-106
    • /
    • 2006
  • We have fabricated a planar lightwave circuit (PLC) hybrid-integrated optical sub-assembly of a triplexer using a thin film filter (TFF)-attached wavelength division multiplexer (WDM) and photodiode (PD) carriers. Two types of TFFs were attached to a diced side of a silica-terraced PLC platform, and the PD carriers with a $45^{\circ}$ mirror on which pin-PDs were bonded were assembled with the platform. A clear transmitter eye-pattern and minimum receiver sensitivity of -24.5 dBm were obtained under 1.25 Gb/s operation for digital applications, and a second-order inter-modulation distortion (IMD2) of -70 dBc was achieved for an analog receiver.

  • PDF

Spot 영상과 Kompsat-2 영상에서의 궤도 자세각 모델의 성능 비교 (Comparison of Orbit-attitude Model between Spot and Kompsat-2 Imagery)

  • 정재훈;김태정
    • 대한원격탐사학회지
    • /
    • 제25권2호
    • /
    • pp.133-143
    • /
    • 2009
  • 이 논문은 엄격한 물리적 센서 모델인 궤도 자세각 모델이 위성체의 자세제어 방식이 다른 두 위성 영상에 적용한 경우 나타나는 성능의 차이를 기술한다. 영상 취득 시 Spot 위성은 거울 회전(mirror-tilt) 방식을 채택하고 있으며 Kompsat-2 위성은 몸통 회전(body-tilt) 방식을 채택하고 있다. 이 논문은 선행 연구에서 이미 우수한 성능이 검증된 궤도 자세각 모델로 연구의 범위를 제한하며 미지수 조합에 따른 센서 모델 정확도 및 3차원 좌표 산출 정확도를 통해 두 영상에서 나타나는 모델 성능의 차이를 비교한다. 실험 결과는 동일한 궤도 자세각 모델이 두 영상에 대해 다른 성능이 나타남을 보여주고 있으며 Spot 위성의 경우에는 자세 각 미지수가 포함된 모델을, Kompsat-2 영상의 경우에는 많은 개수의 미지수를 갖는 모델을 사용하는 것이 효율적임을 제안한다. 이는 동일한 모델이라 하더라도 센서의 영상 취득 방식과 그로 인한 자세 추정의 정확도에 따라 다르게 적용되는 것이 효과적일 수 있음을 나타낸다. 이러한 차이를 이해하는 것은 향후 모델 정확도 개선과 새로운 영상에 대한 모델 적용을 위한 중요한 토대가 될 것이다.

우심증에 동반된 선천성 심장질환의 치험 2례 (Two Cases Reports of Dextrocardia with Congenital Heart Disease)

  • 김준우;김원곤;유세영
    • Journal of Chest Surgery
    • /
    • 제28권7호
    • /
    • pp.698-703
    • /
    • 1995
  • Dextrocardia means right-sided position of the heart in the chest irrespective of the cause. For the absolute diagnosis of the dextrocardia, the segmental analysis of heart is necessary. Once the segmental analysis of the dextrocardia is made, it is often relatively easy to identify the presence of any associated defects based on conventional methods including physical examination, EKG, echocardiography, and angiocardiography. Two cases of dextrocardia with congenital heart disease were treated surgically.A eleven - months old boy was operated under diagnosis of ASD, VSD, and bilateral SVC with mirror - image dextrocardia {I,L,I} by primary closure of ASD and VSD.A twenty-four months old girl was operated under diagnosis of ASD, VSD, and PS with corrected TGA {I,D,D} by primary closure of ASD, VSD and dilatation of pulmonary stenosis. Both of them were discharged healthily after operation.

  • PDF

Low Cost Omnidirectional 2D Distance Sensor for Indoor Floor Mapping Applications

  • Kim, Joon Ha;Lee, Jun Ho
    • Current Optics and Photonics
    • /
    • 제5권3호
    • /
    • pp.298-305
    • /
    • 2021
  • Modern distance sensing methods employ various measurement principles, including triangulation, time-of-flight, confocal, interferometric and frequency comb. Among them, the triangulation method, with a laser light source and an image sensor, is widely used in low-cost applications. We developed an omnidirectional two-dimensional (2D) distance sensor based on the triangulation principle for indoor floor mapping applications. The sensor has a range of 150-1500 mm with a relative resolution better than 4% over the range and 1% at 1 meter distance. It rotationally scans a compact one-dimensional (1D) distance sensor, composed of a near infrared (NIR) laser diode, a folding mirror, an imaging lens, and an image detector. We designed the sensor layout and configuration to satisfy the required measurement range and resolution, selecting easily available components in a special effort to reduce cost. We built a prototype and tested it with seven representative indoor wall specimens (white wallpaper, gray wallpaper, black wallpaper, furniture wood, black leather, brown leather, and white plastic) in a typical indoor illuminated condition, 200 lux, on a floor under ceiling mounted fluorescent lamps. We confirmed the proposed sensor provided reliable distance reading of all the specimens over the required measurement range (150-1500 mm) with a measurement resolution of 4% overall and 1% at 1 meter, regardless of illumination conditions.

드롭숄더 슬리브의 어깨각도 변화에 따른 패턴 연구 (Study of Patterns According to Changes in Shoulder Angle in Drop Shoulder Sleeves)

  • 이하은;이은혜;최정욱
    • 한국의상디자인학회지
    • /
    • 제26권2호
    • /
    • pp.15-32
    • /
    • 2024
  • Modern fashion manifests in forms that mirror the diverse lifestyles and personalities of consumers. It transcends mere aesthetic designs and embodyies practicality. There is a preference for comfortable, highly functional attire, leaning towards easy wear. Casual wear, in particular, embraces a sense of freedom not found in standard business attire. It seeks a comfortable, natural silhouette through tactile fabrics rather than sportswear. Loose, drop shoulder sleeves enhance comfort and mobility and often become key elements in casual wear designs. Given that clothing must balance aesthetics with functionality, especially across various activities, it is natural to prioritize functional design. Research on patterns suited for dynamic conditions is imperative. The rise of drop shoulder styles necessitates the development of corresponding sleeve patterns. It is crucial to differentiate pattern drafting methods due to the resulting silhouette variations. This study aims to categorize drop shoulder pattern drafting techniques based on shoulder extension and angle dimensions. Each method will be examined, and drop shoulder sleeve patterns and wear forms will be studied using a 3D virtual system. This research holds significance in providing valuable insights and foundational data for designing diverse drop shoulder sleeve patterns, contributing to their practical development and advancement.

A급 CMOS 전류 콘베이어 (CCII) (Class A CMOS current conveyors)

  • 차형우
    • 전자공학회논문지C
    • /
    • 제34C권9호
    • /
    • pp.1-9
    • /
    • 1997
  • Novel class A CMOS second-generation current conveyors (CCII) using 0.6.mu.m n-well standard CMOS process for high-frequency current-mode signal processing were developed. The CCII consists of a regulated current-cell for the voltage input and a cascode current mirror for the current output. In this architecture, the two input stages are coupled by current mirrors to reduce the current input impedance. Measurements of the fabricated cCII show that the current input impedance is 308 .ohm. and the 3-dB cutoff frequency when used as a voltage amplifier extends beyond 10MHz. The linear dynamic ranges of voltage and current are from -0.5V to 1.5V and from -100.mu.A to +120.mu.A for supply voltage V$\_$DD/ = -V$\_$SS/=2.5V, respectively. The power dissipation is 2 mW and the active chip area is 0.2 * 0.2 [mm$\^$2/].

  • PDF