• Title/Summary/Keyword: 2-D mirror

Search Result 161, Processing Time 0.029 seconds

A Design of Class A Bipolar Current Conveyor(CCII) with Low Current-Input Impedance and Its Offset Compensated CCII (낮은 전류-입력 임퍼던스를 갖는 A급 바이폴라 전류 콘베이어(CCII)와 그것의 오프셋 보상된 CCII 설계)

  • Cha, Hyeong-U
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.10
    • /
    • pp.754-764
    • /
    • 2001
  • Class A bipolar second-generation current conveyor (CCII) with low current-input impedance and its offset-compensated CCII for high-accuracy current-mode signal processing are proposed. The CCIIs consist of a regulated current-cell for current input, a emitter follower for voltage input, and a cascode current mirror lot current output. In these architecture, the two input stages are coupled by current mirror to reduce the current input impedance. Experiments show that the CCII has impedance of 8.4 Ω and offset voltage of 40 mV at current input terminal. To reduce this offset, the offset-compensated CCII adopts diode-connected npn and pnp transistor in the proposed CCII. Experiments show that the offset-compensated CCII has current input impedance of 2.1 Ω and offset voltage of 0.05 mV. The 3-dB cutoff frequency of the CCIIs when used as a voltage follower extends beyond 30 MHz. The power dissipation is 7.0 mW

  • PDF

Molecular Beam Epitaxy of InAs/AlSb HFET's on Si and GaAs Substrates

  • Oh, Jae-Eung;Kim, Mun-Deok
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.6 no.3
    • /
    • pp.131-135
    • /
    • 2006
  • High electron mobility transistors with InAs channels and antimonide barriers were grown on Si and GaAs substrates by means of molecular beam epitaxy. While direct growth of Sb materials on Si substrate generates disordered and coalescences 3-D growth, smooth and mirror-like 2D growth can be repeatedly obtained by inserting AlSb QD layers between them. Room-temperature electron mobilities of over 10,000 $cm^2/V-s$ and 20,000 $cm^2/v-s$ can be routinely obtained on Si and GaAs substrates, respectively, after optimizing the buffer structure as well as maintaining InSb-like interface.

Four-Channel Differential CMOS Optical Transimpedance Amplifier Arrays for Panoramic Scan LADAR Systems (파노라믹 스캔 라이다 시스템용 4-채널 차동 CMOS 광트랜스 임피던스 증폭기 어레이)

  • Kim, Sang Gyun;Jung, Seung Hwan;Kim, Seung Hoon;Ying, Xiao;Choi, Hanbyul;Hong, Chaerin;Lee, Kyungmin;Eo, Yun Seong;Park, Sung Min
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.9
    • /
    • pp.82-90
    • /
    • 2014
  • In this paper, a couple of 4-channel differential transimpedance amplifier arrays are realized in a standard 0.18um CMOS technology for the applications of linear LADAR(laser detection and ranging) systems. Each array targets 1.25-Gb/s operations, where the current-mode chip consists of current-mirror input stage, a single-to-differential amplifier, and an output buffer. The input stage exploits the local feedback current-mirror configuration for low input resistance and low noise characteristics. Measurements demonstrate that each channel achieves $69-dB{\Omega}$ transimpedance gain, 2.2-GHz bandwidth, 21.5-pA/sqrt(Hz) average noise current spectral density (corresponding to the optical sensitivity of -20.5-dBm), and the 4-channel total power dissipation of 147.6-mW from a single 1.8-V supply. The measured eye-diagrams confirms wide and clear eye-openings for 1.25-Gb/s operations. Meanwhile, the voltage-mode chip consists of inverter input stage for low noise characteristics, a single-to-differential amplifier, and an output buffer. Test chips reveal that each channel achieves $73-dB{\Omega}$ transimpedance gain, 1.1-GHz bandwidth, 13.2-pA/sqrt(Hz) average noise current spectral density (corresponding to the optical sensitivity of -22.8-dBm), and the 4-channel total power dissipation of 138.4-mW from a single 1.8-V supply. The measured eye-diagrams confirms wide and clear eye-openings for 1.25-Gb/s operations.

Development of Ultrasonic Wave Propagation Imaging System

  • Chia, Chen-Ciang;Lee, Jung-Ryul;Kim, Jong-Heon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.283-292
    • /
    • 2009
  • Laser-based ultrasonic sensing requires the probe with fixed fecal length, but this requirement is not essential in laser-based ultrasonic generation. Based on this fact, we designed a pulsed laser-based ultrasonic wave propagation imaging (UWPI) system with a tilting mirror system for rapid scanning of target, and an in-line band-pass filtering capable of ultrasoaic mode selection. 1D-temporal averaging, 2D-spatial averaging, and 3D-data structure building algorithms were developed far clearer results allowing fur higher damage detectability. The imaging results on a flat stainless steel plate were presented in movie and snapshot formats which showed the propagation of ultrasound visible as a concentric wavefield emerging from the location of an ultrasonic sensor. A hole in the plate with a diameter of 1 mm was indicated by the scattering wavefields. The results showed that this robust UWPI system is independent of focal length and reference data requirements.

A Study on the Possibility of Pattern Design Using CAD System (With concentration on the change of coat basic pattern) (CAD System을 이용한 패턴디자인설계 활용가능성에 관한 연구(I)-Coat 원형을 중심으로-)

  • 김옥경
    • Journal of the Korean Society of Costume
    • /
    • v.20
    • /
    • pp.49-62
    • /
    • 1993
  • The purpose of this research was to utilize of Pattern Design System(P.D.S) by using AM-300 The conclusion were like these : 1. A coat of basic pattern was selected by design sketch. 2. The basic pattern was input into computer by digitizing. 3. The basic pattern was change into designed shape by using various skills. This system were enabled to draw straight lines, curves, delete lines, sections of lines, extend lines, cut pattern into sections, measure line or section reproduce whole pattern shape of section, rotate and mirror pattern and complete patterns. 4. Automatic grading of finished master pattern have been developed by creation and modification of grading rules of basic pattern. 5. Production pattern added seam allowance, not-ches was generated by P.D.S menu option. 6. Finished pattern design was plotted out 100% and 20% size by AM-300 Plotter. This results will be the basic materials to develop the CAD SYSTEM if some problems were improve. Furthermore, the utilization of P.D.S is expected to be developing in pattern making process.

  • PDF

Development of Wind Noise Analysis Procedure and Its Verification Using CFD Tool around an OSRVM (CFD를 이용한 OSRVM 주변의 공력소음 해석과정 개발 및 검증)

  • Park, Hyun-Ho;Han, Hyun-Wook;Kim, Moon-Sang;Ha, Jong-Paek;Kim, Yong-Nyun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.4
    • /
    • pp.92-102
    • /
    • 2012
  • The process of the wind noise analysis around an OSRVM is developed and is verified by simulating unsteady flow field past a generic OSRVM mounted on the flat plate at the Reynolds number of $Re_D=5.2{\times}10^5$ based on the mirror diameter. The transient flow field past a generic OSRVM is simulated with various turbulence models, namely DES-SA, LES Constant SGS, and LES Dynamic SGS. The sound radiation is predicted using the Ffowcs- Williams and Hawkings analogy. For the present simulation, the 6.35million cells are generated. Time averaged pressure coefficients at 34 locations on the surface of the generic OSRVM are compared with the available experimental data. Also, 12 Sound Pressure Levels located on the surrounding mirror are compared with the available experimental data. Both of them show good agreements with experimental data.

Cytotoxicity(MTT) evaluation of dental instruments made of polymers (치과용 폴리머 기구의 세포독성(MTT) 평가)

  • Choi, Eun-Mi
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.8
    • /
    • pp.187-195
    • /
    • 2021
  • In order to assess the cell toxicity of 10 instruments made of polymers, the MTT assay which utilizes the L-929 cell was selected. Specimens were eluted at a temperature of 37℃ for 24 hours at a rate of 4g per 20mL, RPMI 1640, and then was positively and negatively contrasted with a control test solution, in accordance with the Notification No. 2020-12 Protocols of Medical Apparatus Biological Safety from the Ministry of Drug and Food Safety. As a result of 24 hours of incubation in 37℃, 5% CO2 Incubator and assessment using an ELISA reader, the results of Intraoral camera indiciated a cellular viability of more than 70% at a 50% eluate. But, the Plastic impression tray, 3D printing tweezer, Impression disposable syringe, Dental floss holder, Hand implant scaler, Surgical retractor, Oral scanner tip, Dental mirror, and the Water pick tip all reported a cellular viability of more than 70% at a 100% eluate, which indicates that do not exhibit cytotoxicity, thus allowing it to be used in contact with the mucous membrane of the oral cavity.

Development and performance test of a complex laser interferometer for simultaneously measuring displacement and 2-D angles (변위 각도 동시 측정용 복합 레이저 간섭계의 제작과 특성 분석)

  • Kim J.W.;Kim J.A.;Kang C.S.;Eom T.B.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.573-576
    • /
    • 2005
  • A compact linear and angular displacement measurement device was developed by combining a Michelson interferometer and an autocollimator to characterize the movement of a precision stage. A Michelson interferometer and an autocollimator are typical devices for measuring linear and angular displacement, respectively. By controlling the polarization of reflected beam from the target mirror of the interferometer, some part of light was retro-reflected to the light source and the reflected beam was used for angle measurement. The interferometer and the autocollimator use the same optic axis and the target mirror can be easily and precisely aligned orthogonal to the optic axis by monitoring the autocollimator s signal. The autocollimator was designed for angular resolution of 0.1 arcsec and dynamic range of 60 arcsec. The nonlinearity error of interferometer was minimized by trimming the gain and offset of the photodiode signals. Through the experiments, we evaluate the performance of measurement device and discuss its applications.

  • PDF

Colorimetric Design of Dichroic Mirrors in 3-LCD Projection Systems (3판식 액정 프로젝션 시스템의 다이크로익 미러의 색채학적 설계)

  • Kim, Jee-Hong
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.9
    • /
    • pp.70-77
    • /
    • 1998
  • A new method is proposed for the design of the dichroic mirrors in 3-LCD projection systems for color separation/composition. Rather than simply basing the color performance criterion on luminance or chromatic saturation only, the optimum design parameters can be found by maximizing the perceived color gamut in a 3-D uniform color space. In this method, the half-power wavelengths were optimized by maximizing the volume of the reproducible color gamut in a CIELUV uniform color space for 2 typical viewing conditions, with proper colorimetric analysis of color reproduction in 3-LCD projection systems.

  • PDF

A 3D Solder Paste Inspection System Using Multiple Slit Rays (다중 슬릿광을 이용한 3차원 Solder Paste 검사 시스템)

  • Cho, Tai-Hoon;Huh, Byoung-Hweh
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.2
    • /
    • pp.151-157
    • /
    • 2002
  • A 3-dimenstional automatic solder paste inspection system is described that can be used to find defects occurring in solder paste printing process. This system extracts height and volume information very fast as well as area of solder paste printed, using multiple slit ray projection and Galvano-mirror scanning. Methods are presented on calibration of camera and slit projector, real-time image processing of multiple slit images, determination of reference height, and extraction of paste height information are proposed. Performance of the system was successfully demonstrated through field tests.