• 제목/요약/키워드: 2-D duct

검색결과 156건 처리시간 0.026초

해양 구조물용 공조덕트 열유동에 관한 수치해석 (Numerical Analysis on the Thermal and Fluid in Air Conditioning Duct for Marine Offshore)

  • 이중섭;이병호;진도훈
    • 한국기계가공학회지
    • /
    • 제18권2호
    • /
    • pp.7-13
    • /
    • 2019
  • This study is about distributions of heat transfer in air conditioning duct used for marine and oil drilling ship. As the convective heat transfer coefficient increased, heat transfer was conducted dynamically to inside as it exited to the outlet of duct. So, it was checked that the amount of heat transfer generated at duct increased as the convective heat transfer coefficient increased. In case the convective heat transfer coefficient was low, the temperature of duct showed the relatively high temperature distribution due to the temperature influence of internal fluid as the heat transfer between the outside and inside of the duct. In case of temperature distribution generated the volume of the duct along the change of the convective heat transfer coefficient, it was found out that the temperature descended as heat transfer was promoted and the convective heat transfer coefficient increased.

Static Structural Analysis on the Mechanical behavior of the KALIMER Fuel Assembly Duct

  • Kim, Kyung-Gun;Lee, Byoung-Oon;Woan Hwang;Kim, Young ll;Kim, Yong su
    • Nuclear Engineering and Technology
    • /
    • 제33권3호
    • /
    • pp.298-306
    • /
    • 2001
  • As fuel burnup proceeds, thermal gradients, differential swelling, and inter-assembly loading may induce assembly duct bowing. Since duct bowing affects the reactivity, such as long or short term power-reactivity-decrement variations, handling problem, caused by top end deflection of the bowed assembly duct, and the integrity of the assembly duct itself. Assembly duct bowing were first observed at EBR-ll in 1965, and then several designs of assembly ducts and core restraint system were used to accommodate this problem. In this study, NUBOW-2D KMOD was used to analyze the bowing behavior of the assembly duct under the KALIMER(Korea Advanced Liquid MEtal Reactor) core restraint system conditions. The mechanical behavior of assembly ducts related to several design parameters are evaluated. ACLP(Above Core Load Pad) positions, the gap distance between the ducts, and the gap distance between the duct and restraint ring were selected as the sensitivity parameter for the evaluation of duct deflection.

  • PDF

돈사 덕트 환기시스템의 효율 분석 (Analysis of Ventilation Efficiency by Duct System in Pig House)

  • 송준익;유용희;이덕수;최희철;강희설;김태일;전병수;박치호;김형호
    • 한국축산시설환경학회지
    • /
    • 제8권2호
    • /
    • pp.73-78
    • /
    • 2002
  • The experiment was carried out to investigate the optimal air velocity for improving the ventilation efficiency of duct ventilation system used in Korean swine building. The results are followed ; In 2.2 m height of duct, the air velocity of hole was 5.0 m/s as the over level of recommendation. In different hole interval, the air velocity was various of 4.6${\sim}$11.6 m/s in narrow hole interval, 5.4${\sim}$10.9 m/s in broad hole interval. But the air velocity was 6.6${\sim}$7.7 m/s in duct system pierced hole with equal interval, and it was equal velocity in different parts of duct in this hole interval.

  • PDF

이차 냉각 유로를 가진 회전덕트에서 열/물질전달 특성 (II) - 덕트 종횡비에 따른 영향 - (Detailed Measurement of Heat/Mass Transfer in a Rotating Two-Pass Duct (II) - Effects of Duct Aspect Ratio -)

  • 김경민;김윤영;이동호;조형희
    • 대한기계학회논문집B
    • /
    • 제28권8호
    • /
    • pp.921-928
    • /
    • 2004
  • Measurements of local heat/mass transfer coefficients in rotating two-pass ducts are presented. Ducts of three different aspect ratios (W/H), 0.5, 1.0 and 2.0, are employed with a fixed hydraulic diameter ($D_h$) of 26.7 nm. $90^{\circ}$-rib turbulators are attached on the leading and trailing walls symmetrically. The rib height-to-hydraulic diameter ratio ($e/D_h$) is 0.056, and the rib pitch-to-rib height ratio (p/e) is 10. The experimental conditions are the same as those of the previous part of the study. As the rib height-to-duct height ratio (e/H) increases, the core flow is more disturbed and accelerated in the midsections of ribs. Therefore, the obtained data show higher heat/mass transfer in the higher aspect ratio duct. Dean vortices also augment heat/mass transfer in the turn and in the upstream region of the second pass. However, the effect becomes less significant for the higher aspect ratio because the surface area increases in the present geometric condition. The effect of rotation produces heat/mass transfer discrepancy.

Experimental and Numerical Studies on the Possibility of Duct Flow Low-power Generation Using a Butterfly Wind Turbine

  • Hara, Yutaka;Kogo, Shohei;Takagaki, Katsuhiro;Kawanishi, Makoto;Sumi, Takahiro;Yoshida, Shigeo
    • International Journal of Fluid Machinery and Systems
    • /
    • 제10권1호
    • /
    • pp.19-29
    • /
    • 2017
  • An objective of this study is to demonstrate the validity of using a small wind turbine to recover the fluid energy flowing out of an exhaust duct for the generation of power. In these experiments, a butterfly wind turbine of a vertical axis type (D = 0.4 m) is used. The output performance is measured at various locations relative to the exit of a small wind tunnel (W = 0.65 m), representing the performance expected in an exhaust duct flow. Two-dimensional numerical analysis qualitatively agrees with the experimental results for the wind turbine power coefficient and rate of energy recovery. When the turbine is far from the duct exit (more than 2.5 D), an energy recovery rate of approximately 1.3% is obtained.

엔진베이 환기용 이젝터시스템 개발 (Development of an Ejector System for the Engine-Bay Ventilation)

  • 임주현;김용련;전상인;장성호;이상효
    • 항공우주시스템공학회지
    • /
    • 제8권1호
    • /
    • pp.30-35
    • /
    • 2014
  • This study has been conducted to develop an ejector system applied in the aircraft engine-bay ventilation system. Tandem-Ejector was selected as a component of ventilation system because it could achieve high ventilation performance in spite of motive flow with small flow rate. Tandem-Ejector is composed of a primary nozzle and two mixing ducts ($1^{st}$ mixing duct and $2^{nd}$ mixing duct). In this study, 1-D Tandem-Ejector model has been built with conservation laws and isentropic relation for 1-D ejector sizing and performance prediction. Computational Fluid Dynamics(CFD) has been conducted to investigate ejector performance and flow characteristics in the ejector. Also, Tandem-Ejector performance tests have been conducted to obtain ejector pumping performance and to investigate stand-off (gap between primary nozzle and $1^{st}$ mixing duct inlet) effect on ejector pumping performance.

사각덕트내의 유체유동에 관한 수치계산과 실험의 비교 (The comparison between Numerical Computation and Experiment on Fluid Elow in Rectangular Duct)

  • 윤영환;배택희;박원구
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.71-74
    • /
    • 2002
  • Fluid flow in a rectangular duct system are measured by W laser doppler velocity meter, and also computed by commercial software of STAR-CD for comparison between then First, for a rectangular duct with 90 degree metered elbow, the fluid flow with Reynolds numbs's of 1,508 is predicted by assumption of both laminar and turbulent models. But, even though the Reynolds number is less than 2,300-3,000, the computation by turbulent model is close to the experimental data. Moeover, the computation by turbulent model for Reynolds number of 11,751 also predicts the experimental data satisfactorily. Second, for a rectangular duct with two branch ducts, the ratios between flow rates in the two branches are invariant to Reynolds number according to both of numerical and experimental results.

  • PDF

차량 화재시험장치 설계를 위한 수치해석적 연구 (The Development of Fire Test Facility using the Numerical Analysis)

  • 유용호;김흥열
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.919-922
    • /
    • 2008
  • The objective of this study is to design the full-scale fire test facility of the railroad vehicle with CFD simulation. In the results, the step expansion system should be good enough for the measuring system. Uniform flow is achieved at eight-to-ten diameters of the expanded duct behind the step for moderate expansion ratios($D_{orifice}/D_{duct}$ = 2 being a good choice). To optimization of the fire products collector system with 5 dampers, the additional CFD simulation was also carried out. These results will be help for the railroad fire safety research.

  • PDF

정4각 덕트 입구영역에서 천이파동유동의 속도분포와 입구길이에 관한 연구 (A study on velocity profiles and inlet length of developing transitional pulsating flows in the entrance region of a square duct)

  • 유영태;모양유;홍성삼
    • 오토저널
    • /
    • 제15권2호
    • /
    • pp.92-104
    • /
    • 1993
  • In the present study, the velocity profiles and entrance length of developing transitional pulsating flows are investigated both analytically and experimentally in the entrance region of a square duct. The systems of conservation equations for transitional pulsating flows in a square duct are solved analytically by linearizing the non-linear convective terms. Analytical solutions are obtained in the form of infinite series for velocity pofiles. The experimental study for the air flow in a square duct(40mm*40mm*4000mm) is carried out to measure velocity profiles and other parameters by using a hot-wire anemometer with a data acquisition and processing system. The distribution of velocity profiles( $u_{ps}$ / $u_{m,ta}$) in the decelerating period is higher than in the accelerating period. The distribution of the axial component of the axial component of velocity in the transitional flow is nearly uniform in the central region of the duct, and decrease rapidly near the wall. The entrance length correlation of the transitional pulsating flows in a square duct is obtained to be $L_{e}$/ $D_{h}$=0.83 $A_{1}$R $e_{ta}$ /(.omega. sup+1)$^{2}$TEX>

  • PDF

기울어진 덕트 내 헬리컬 코일의 자연대류 열전달 (Natural Convection Heat Transfer of an Inclined Helical Coil in a Duct)

  • 박주현;정범진
    • 에너지공학
    • /
    • 제23권2호
    • /
    • pp.13-20
    • /
    • 2014
  • 헬리컬 코일이 덕트 내부에 있을 때, 기울기에 따른 자연대류 열전달을 실험적으로 측정하였다. 고부력 조건을 구현하기 위하여 유사성에 기초하여 열전달 실험을 대신하여 물질전달 실험을 수행하였다. RaD 수 $4.55{\times}10^6$에서, 턴(Turn) 수를 1~10, P/D를 1.3~5, 헬리컬 코일의 기울기를 $0^{\circ}{\sim}90^{\circ}$까지 변화시켰다. 헬리컬 코일의 턴 수가 1일 때, 측정된 $Nu_D$ 수는 McAdams의 수평관 자연대류 열전달 상관식과 거의 일치하였다. 기울어진 덕트 내 헬리컬 코일의 자연대류 열전달은 피치, 턴 수, 덕트 높이에 따라 복합적으로 변화하였고 이는 속도 효과, 굴뚝 효과, 예열 효과로 분석되었다. 본 연구의 결과는 Compact heat exchanger에서의 자연대류 열전달에 대한 현상학적 분석에 기여한다.