• Title/Summary/Keyword: 2-D Motion

Search Result 1,431, Processing Time 0.026 seconds

Automated Markerless Analysis of Human Gait Motion for Recognition and Classification

  • Yoo, Jang-Hee;Nixon, Mark S.
    • ETRI Journal
    • /
    • v.33 no.2
    • /
    • pp.259-266
    • /
    • 2011
  • We present a new method for an automated markerless system to describe, analyze, and classify human gait motion. The automated system consists of three stages: I) detection and extraction of the moving human body and its contour from image sequences, ii) extraction of gait figures by the joint angles and body points, and iii) analysis of motion parameters and feature extraction for classifying human gait. A sequential set of 2D stick figures is used to represent the human gait motion, and the features based on motion parameters are determined from the sequence of extracted gait figures. Then, a k-nearest neighbor classifier is used to classify the gait patterns. In experiments, this provides an alternative estimate of biomechanical parameters on a large population of subjects, suggesting that the estimate of variance by marker-based techniques appeared generous. This is a very effective and well-defined representation method for analyzing the gait motion. As such, the markerless approach confirms uniqueness of the gait as earlier studies and encourages further development along these lines.

A convergence analysis of a differential method for 2-D motion parameter estimation (미분 추정 기법에 의한 2파원 이동 파라미터 추정의 수렴 특성 분석)

  • 이상희;유국열;김재균
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.7
    • /
    • pp.1869-1882
    • /
    • 1998
  • In this paper, we investigae convergence behaviors of a differential method for 2-D motion parameter estimation. While the differential method is widely studied for motion compensated prediction in video coding, little attention hs been paid to its convergence properties. Based on the nonseparable exponential covariance image model, we derive the estimates of update terms for the 2- and 6-parameter motion models. And, the effect of noise, spatial correlation, choice of spatial gradient measures, andthe size of a region, are quantitatively anlyzed in relation to the convergence speed. Some empirical results are presented to verify the analysis.

  • PDF

Analysis of Respiratory Motion Artifacts in PET Imaging Using Respiratory Gated PET Combined with 4D-CT (4D-CT와 결합한 호흡게이트 PET을 이용한 PET영상의 호흡 인공산물 분석)

  • Cho, Byung-Chul;Park, Sung-Ho;Park, Hee-Chul;Bae, Hoon-Sik;Hwang, Hee-Sung;Shin, Hee-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.174-181
    • /
    • 2005
  • Purpose: Reduction of respiratory motion artifacts in PET images was studied using respiratory-gated PET (RGPET) with moving phantom. Especially a method of generating simulated helical CT images from 4D-CT datasets was developed and applied to a respiratory specific RGPET images for more accurate attenuation correction. Materials and Methods: Using a motion phantom with periodicity of 6 seconds and linear motion amplitude of 26 mm, PET/CT (Discovery ST: GEMS) scans with and without respiratory gating were obtained for one syringe and two vials with each volume of 3, 10, and 30 ml respectively. RPM (Real-Time Position Management, Varian) was used for tracking motion during PET/CT scanning. Ten datasets of RGPET and 4D-CT corresponding to every 10% phase intervals were acquired. from the positions, sizes, and uptake values of each subject on the resultant phase specific PET and CT datasets, the correlations between motion artifacts in PET and CT images and the size of motion relative to the size of subject were analyzed. Results: The center positions of three vials in RGPET and 4D-CT agree well with the actual position within the estimated error. However, volumes of subjects in non-gated PET images increase proportional to relative motion size and were overestimated as much as 250% when the motion amplitude was increased two times larger than the size of the subject. On the contrary, the corresponding maximal uptake value was reduced to about 50%. Conclusion: RGPET is demonstrated to remove respiratory motion artifacts in PET imaging, and moreover, more precise image fusion and more accurate attenuation correction is possible by combining with 4D-CT.

The method to estimate 3-D coordinates of lower trunk muscles using orientation angles during a motion (몸통 운동시 지향각(Orientation angles)을 이용한 허리 근육의 3차원 위치 좌표 추정 기법)

  • Lim, Young-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.1
    • /
    • pp.125-133
    • /
    • 2002
  • The purpose of this study was to develop a method for estimating 3-D coordinates of lower trunk muscles using orientation angles during a motion. Traditional 3-D motion analysis system with DLT technique was used to track down the locations of eight reference markers which were attached on the back of the subject. In order to estimate the orientations of individual lumbar vertebrae and musculoskeletal parameters of the lower trunk muscle, the rotation matrix of the middle trunk reference frame relative to the lower trunk reference frame was determined and the angular locations of individual lumbar vertebrae were estimated by partitioning the orientation angles (Cardan angles) that represent the relative angles between the rotations of the middle and lower trunks. When the orientation angles of individual intervertebral joints were known at a given instant, the instantaneous coordinates of the origin and insertion for all selected muscles relative to the L5 local reference frame were obtained by applying the transformation matrix to the original coordinates which were relative to a local reference frame (S1, L4, L3, L2, or L1) in a rotation sequence about the Z-, X- and Y-axes. The multiplication of transformation matrices was performed to estimate the geometry and kinematics of all selected muscles. The time histories of the 3-D coordinates of the origin and insertion of all selected muscles relative to the center of the L4-L5 motion segment were determined for each trial.

Optimal design of a flexure hinge-based XY AFM scanner for minimizing Abbe errors and the evaluation of measuring uncertainty of AFM system (원자현미경용 XY 스캐너의 아베 오차 최소화를 위한 최적 설계 및 원자 현미경의 측정 불확도 평가)

  • Kim D.M.;Lee D.Y.;Gweon D.G.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1438-1441
    • /
    • 2005
  • To establish of standard technique of nano-length measurement in 2D plane, new AFM system has been designed. In this system, measurement uncertainty is dominantly affected by the Abbe error of XY scanning stage. No linear stage is perfectly straight; in other words, every scanning stage is subject to tilting, pitch and yaw motion. In this paper, an AFM system with minimum offset of XY sensing is designed. And XY scanning stage is designed to minimize rotation angle because Abbe errors occur through the multiply of offset and rotation angle. To minimize the rotation angle optimal design has performed by maximizing the stiffness ratio of motion direction to the parasitic motion direction of each stage. This paper describes the design scheme of full AFM system, especially about XY stage. Full range of fabricated XY scanner is $100um\times{100um}$. And tilting, pitch and yaw motion are measured by autocollimator to evaluate the performance of XY stage. Using this AFM system, 3um pitch specimen was measured. As a result, the uncertainty of total system has been evaluated.

  • PDF

A Review of Motion Capture Systems: Focusing on Clinical Applications and Kinematic Variables (모션 캡처 시스템에 대한 고찰: 임상적 활용 및 운동형상학적 변인 측정 중심으로)

  • Lim, Wootaek
    • Physical Therapy Korea
    • /
    • v.29 no.2
    • /
    • pp.87-93
    • /
    • 2022
  • To solve the pathological problems of the musculoskeletal system based on evidence, a sophisticated analysis of human motion is required. Traditional optical motion capture systems with high validity and reliability have been utilized in clinical practice for a long time. However, expensive equipment and professional technicians are required to construct optical motion capture systems, hence they are used at a limited capacity in clinical settings despite their advantages. The development of information technology has overcome the existing limit and paved the way for constructing a motion capture system that can be operated at a low cost. Recently, with the development of computer vision-based technology and optical markerless tracking technology, webcam-based 3D human motion analysis has become possible, in which the intuitive interface increases the user-friendliness to non-specialists. In addition, unlike conventional optical motion capture, with this approach, it is possible to analyze motions of multiple people at simultaneously. In a non-optical motion capture system, an inertial measurement unit is typically used, which is not significantly different from a conventional optical motion capture system in terms of its validity and reliability. With the development of markerless technology and advent of non-optical motion capture systems, it is a great advantage that human motion analysis is no longer limited to laboratories.

Low Complexity Motion Estimation Search Method for Multi-view Video Coding (다시점 비디오 부호화를 위한 저 복잡도 움직임 추정 탐색 기법)

  • Yoon, Hyo-Sun;Kim, Mi-Young
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.5
    • /
    • pp.539-548
    • /
    • 2013
  • Although Motion estimation (ME) plays an important role in digital video compression, it requires a complicated search procedure to find an optimal motion vector. Multi-view video is obtained by capturing one three-dimensional scene with many cameras at different positions. The computational complexity of motion estimation for Multi-view video coding increases in proportion to the number of cameras. To reduce computational complexity and maintain the image quality, a low complexity motion estimation search method is proposed in this paper. The proposed search method consists of four-grid diamond search patten, two-gird diamond search pattern and TZ 2 Point search pattern. These search patterns exploit the characteristics of the distribution of motion vectors to place the search points. Experiment results show that the speedup improvement of the proposed method over TZ search method (JMVC) can be up to 1.8~4.5 times faster by reducing the computational complexity and the image quality degradation is about to 0.01~0.24 (dB).

Two-Dimensional Entropy Minimizing Autofocusing of Millimeter-Wave (W-Band) FMCW SAR (밀리미터파(W 밴드) 탐색기용 FMCW SAR 영상의 2차원 엔트로피 최소 자동 초점 기법)

  • Park, Jaehyun;Chun, Joohwan;Lee, Hyukjung;Song, Sungchan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.4
    • /
    • pp.316-319
    • /
    • 2018
  • To detect the ground moving target, forward-looking SAR images obtained from the FMCW radar can be exploited. However, the quality of the SAR image is deteriorated due to the turbulence or fluctuation because of the flight path condition during the missile movement. We herein propose an entropy-minimizing autofocus method to compensate the motion error of forward-looking SAR. In particular, owing to the geometry of the forward-looking SAR, the motion error affects the SAR image in the two-dimensional (2D) form (azimuth and time axis). Therefore, we suggest a 2D autofocus method for the motion compensation.

The elbow is the load-bearing joint during arm swing

  • Bokku Kang;Gu-Hee Jung;Erica Kholinne;In-Ho Jeon;Jae-Man Kwak
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.2
    • /
    • pp.126-130
    • /
    • 2023
  • Background: Arm swing plays a role in gait by accommodating forward movement through trunk balance. This study evaluates the biomechanical characteristics of arm swing during gait. Methods: The study performed computational musculoskeletal modeling based on motion tracking in 15 participants without musculoskeletal or gait disorder. A three-dimensional (3D) motion tracking system using three Azure Kinect (Microsoft) modules was used to obtain information in the 3D location of shoulder and elbow joints. Computational modeling using AnyBody Modeling System was performed to calculate the joint moment and range of motion (ROM) during arm swing. Results: Mean ROM of the dominant elbow was 29.7°±10.2° and 14.2°±3.2° in flexion-extension and pronation-supination, respectively. Mean joint moment of the dominant elbow was 56.4±12.7 Nm, 25.6±5.2 Nm, and 19.8±4.6 Nm in flexion-extension, rotation, and abduction-adduction, respectively. Conclusions: The elbow bears the load created by gravity and muscle contracture in dynamic arm swing movement.

Construction of 3D shapes of objects from reconstructed 3D points (복원된 3차원 점들로부터 3차원 객체 모양 구성)

  • Mlyahilu, John;Kim, Jongnam
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2018.10a
    • /
    • pp.822-824
    • /
    • 2018
  • Estimation of 3-D objects from 2-D images is inherently performed by either motion or scene features methods as it has been described in different literatures. Structure from motion as a method employed in this study uses calibrated camera and reconstructed 3-D points from the structure of the scene for reliable and precise estimates. In this study we construct 3-D shapes using color pixels and reconstructed 3-D points to determine observable differences for the constructed 3-D images. The estimation using reconstructed 3-D points indicates that the sphere is recovered by the use of scale factor due to its known size while the one obtained by using color pixels has look similar to the former but different in the scales of the axes.