• Title/Summary/Keyword: 2-질량 시스템

Search Result 221, Processing Time 0.022 seconds

Simulation of Scooped Swing in High Bar Using Lagrange's Method : A Case Study (라그랑지 방법을 이용할 철봉 몸굽혀 휘돌기 동작의 시뮬레이션)

  • Hah, Chong-Ku
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.4
    • /
    • pp.234-240
    • /
    • 2007
  • The purpose of this paper was to architecture optimal model of the scooped swing in high bar. The scooped swing was modeled to the double pendulum and was simulated with the Lagrange's equation of motion. Lagrange's method based on a energy approaching method was implemented as a equation of motion. The subject was a national man-gymnast(age 18yrs, height 153 cut mass 48 kg) and the high bar of SPIETH company was used to measure the scooped swing. Qualisys system(six MCU-240 cameras, QTM software)was used to capture data for imaging analysis. The solution of a model and data processing were solved in Mathematica5.0. The results were as follows: First model value of maximum bar displacement was longer than experimental value, that is, 0.02 m. Second, both angular pattern of segment1(HAT) had a increasing curve but curve patterns had a different concave and convex me. Third the experimental value of maximum angular angle of segment2(total leg) had larger than model value, that is, $4^{\circ}$. Conclusively, model parameters were quasi-optimized to obtain a quasi-match between simulated and actual performances. It hopes to simulate a human model by means of integrating musculoskeletal and neuromuscular system in the future study.

Experimental Study of Low-Frictional Behavior for Sliding Slab Track (슬라이딩 궤도의 저마찰 거동에 대한 실험적 연구)

  • Kim, Tae-Gu;Jung, Dong-Ki;Lee, Kyoung-Chan
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.2
    • /
    • pp.241-247
    • /
    • 2017
  • Railway bridges with continuously welded rail have a limitation of span length due to track-bridge interaction. In order to overcome this, a sliding slab track system has been developed that comprises with a low-frictional sliding layer between the bridge deck and the track slab to isolate the longitudinal behavior between the bridge and the track. In this study, a real scale track system is prepared to experimentally evaluate the longitudinal frictional behavior. Applied loading rates were 0.2, 1.0, 5.0 and 10mm/min; vertical mass on the track are track slab only, 5,000 and 10,000kg added mass, respectively. Test results showed that the resulting frictional coefficients varied from 0.22 to 0.33. In addition, 10,000 cycle loadings were applied to simulate repetitive sliding to represent 30 years of service life. The frictional coefficient increase was measured and found to be 7% of that of the initial loading stage, which means that the sliding layer is adequate to provide low-frictional behavior for the sliding slab track system. Effects of changes of the frictional coefficient of the sliding layer were analyzed by rail-structure interaction analysis.

A Study on the Electrochemical Performance of Fe-V Chloric/Sulfuric Mixed Acid Redox Flow Battery Depending on Electrode Activation Temperature (Fe-V Chloric/Sulfuric Mixed Acid 레독스흐름전지 전극의 활성화 온도에 따른 전기화학적 성능 고찰)

  • Lee, Han Eol;Kim, Dae Eop;Kim, Cheol Joong;Kim, Taekeun
    • Applied Chemistry for Engineering
    • /
    • v.31 no.6
    • /
    • pp.639-645
    • /
    • 2020
  • Among the components of redox flow battery (RFB), the electrode serves as a diffusion layer of an electrolyte and a path for electrons and also is a major component that directly affects the RFB performance. In this paper, chloric/sulfuric mixed acidwas used as a supporting electrolyte in RFB system with Fe2+/Fe3+ and V2+/V3+ as redox couple. The optimum electrode and activation temperature were suggested by comparing the capacity, coulombic efficiency and energy efficiency according to the electrode type and activation temperature. In the RFB single cell evaluation using 5 types of carbon electrodes used in the experiments, all of them showed close to the theoretical capacity to retain the reliability of the evaluation results. GFD4EA showed relatively excellent energy efficiency and charge/discharge capacity. In order to investigate the electrochemical performance according to the activation temperature, GFD4EA electrode was activated by heat treatment at different temperatures of 400, 450, 500, 600 and 700 ℃ under an air atmosphere. Changes in physical properties before and after the activation were observed using electrode mass retention, scanning electron microscope (SEM), XPS analysis, and electrochemical performance was compared by conducting RFB single evaluation using electrodes activated at each temperature given above.

Design and Fabrication of 4-beam Silicon-Micro Piezoresistive Accelerometer for TPMS Application (TPMS용 4빔 실리콘 미세 압저항형 가속도센서의 설계 및 제작)

  • Park, Ki-Woong;Kim, Hyeon-Cheol
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.2
    • /
    • pp.1-8
    • /
    • 2012
  • This paper presents the accelerometer which is a key component of TPMS(Tire Pressure Monitoring System). Generally a piezoresistive accelerometer has characteristics of lower cost, better linearity and better immunity about the environmnet noise than a capacitive one. Three types of piezoresistive accelerometers are degined and simulated using ANSYS program. The best one is a piezoresistive sensor which is supported by four beams located at the center of the edge of the mass after comparing the characteristics of resonant frequency of the three types. Considering the sensor size and a simulated maximum stress and maximum displacement, the length of beams is set as $200{\mu}m$. The size of a piezoresistive accelerometer is $3.0mm{\times}3.0mm{\times}0.4mm$. The sensor output is characterized by measuring the output characteristic depending on angle. As a result the offset voltage of the accelerometer is 43.2 mV and its sensitivity is $42.5{\mu}V/V/g$. The temperature bias drift is measured. The shock durability of the sensor is 1500g and the measuring range is 0 ~ 60 g.

p-Type Activation of AlGaN-based UV-C Light-Emitting Diodes by Hydrogen Removal using Electrochemical Potentiostatic Activation (전기화학적 정전위 활성화를 사용한 수소 제거에 의한 AlGaN기반의 UV-C 발광 다이오드의 p-형 활성화)

  • Lee, Koh Eun;Choi, Rak Jun;Kumar, Chandra Mohan Manoj;Kang, Hyunwoong;Cho, Jaehee;Lee, June Key
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.4
    • /
    • pp.85-89
    • /
    • 2021
  • AlGaN-based UV-C light-emitting diodes (LEDs) were applied for p-type activation by electrochemical potentiostatic activation (EPA). The p-type activation efficiency was increased by removing hydrogen atoms through EPA treatment using a neutral Mg-H complex that causes high resistance and low conductivity. A neutral Mg-H complex is decomposed into Mg- and H+ depending on the key parameters of solution, voltage, and time. The improved hole carrier concentration was confirmed by secondary ion mass spectroscopy (SIMS) analysis. This mechanism eventually improved the internal quantum efficiency (IQE), the light extraction efficiency, the leakage current value in the reverse current region, and junction temperature, resulting in better UV-C LED lifetime. For systematic analysis, SIMS, Etamax IQE system, integrating sphere, and current-voltage measurement system were used, and the results were compared with the existing N2-annealing method.

Low Temperature Latent Heat Storage Material of Cooling Characteristics According to Concentration of TMA (TMA 농도에 따른 저온잠열축열물질의 냉각특성)

  • Kim, Chang-Oh;Chung, Hyun-Ho;Chung, Nak-Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.2
    • /
    • pp.173-178
    • /
    • 2010
  • The ice storage system uses water for low temperature latent heat storage. However, a refrigerator capacity are increased and COP are decreased due to supercooling of water in the course of phase change from liquid to solid. This study investigates the cooling characteristics of the TMA-water clathrate compound including TMA (Tri-methyl-amine, $(CH_3)_3N$) of 20~25 wt% as a low temperature latent heat storage material. The results showed that the phase change temperature are increased and the supercooling degree and the specific heat are decreased according to the weight concentration of TMA increased. Especially, the clathrate compound containing TMA 25wt% has the average phase change temperature of $5.8^{\circ}C$ and the supercooling degree of $8.0^{\circ}C$, retention time of liquid phase for 651sec and specific heat of 3.499 kJ/kgK in the cooling process. This expressed good than different concentration of TMA cooling characteristic. Like this, to apply TMA 25wt%-water clathrate compound is determined by advantageous as the low temperature latent heat storage material.

Estimation of Potential Evapotranspiration using LAI (LAI를 고려한 잠재증발산량 추정)

  • Kim, Joo-Hun;Kim, Kyung-Tak
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.8 no.4
    • /
    • pp.1-13
    • /
    • 2005
  • In the process of a hydrology circulation, evapotranspiration is considered a very important factor to build a plan for the development of water resources and to operate water resources system. This study purposes to estimate daily potential evapotranspiration quantity in consideration of energy factors of the surface by using spatial information such as Landsat TM (ETM+) data, DEM and Landcover. Kyounan-cheon, Han River is selected as a target area, and landcover is divided by vegetation and non-vegetation covered area. Penman-Monteith equation which considers leaf-area index is used to estimate potential evapotranspiration quantity of vegetation covered area. The combination method (energy burget and aerodynamic method) is used in non-vegetation covered area. Among the input data for estimating potential evapotranspiration, NDVI, SR and Albedo is formed by Landsat, TM and ETM+ from 1986 through 2002. ground heat flux is estimated by using NDVI distribution map, LAI distribution map is drawn by using SR distribution map. The result of estimation shows that the average potential evapotranspiration in the whole basin is about 1.8-3.2mm/day per each cell. THe results of estimating potential evapotranspiration quantity by each landcover are as follows; water surface 3.6-4.9mm/day, city 1.4-3.1mm/day, bareland 1.4-3.5mm/day, grassland 1.7-3.7mm/day, forest 1.7-3.0mm/day and farmland 1.8-3.6mm/day. The potential evapotranspiration quantity is underestimated in comparison with observed evaporation data by evaporation pan, but it is considered that it has physical propriety.

  • PDF

Optimization Design of Damping Devices for a Super-Tall Building Using Computational Platform (전산플랫폼을 이용한 초고층구조물의 감쇠장치 최적화 설계)

  • Joung, Bo-Ra;Lee, Sang-Hyun;Chung, Lan;Choi, Hyun-Chul
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.2
    • /
    • pp.145-152
    • /
    • 2015
  • In the study, the effects of damping devices on damping ratio increase and wind-load reduction were investigated based on the computational platform, which is one of the parametric modeling methods. The computational platform helps the designers or engineers to evaluate the efficacy of the numerous alternative structural systems for irregular Super-Tall building, which is crucial in determining the capacity and the number of the supplemental damping devices for adding the required damping ratios to the building. The inherent damping ratio was estimated based on the related domestic and foreign researches conducted by using real wind-load records. Two types of damping devices were considered: One is inter-story installation type passive control devices and the other is mass type active control devices. The supplemental damping ratio due to the damping devices was calculated by means of equivalent static analysis using an equation suggested by FEMA. The optimal design of the damping devices was conducted by using the computational platform. The structural element quantity reduction effect resulting from the installation of the damping devices could be simply assessed by proposing a wind-load reduction factor, and the effectiveness of the proposed method was verified by a numerical example of a 455m high-rise building. The comparison between roof displacement and the story shear forces by the nonlinear time history analysis and the proposed method indicated that the proposed method could simply but approximately estimate the effects of the supplemental damping devices on the roof displacement and the member force reduction.

PHOTOMETRIC SOLUTIONS AND SPOT MODEL OF THE CONTACT BINARY AB ANDROMEDAE (접촉쌍성 AB Andromedae의 측광해와 흑점모델)

  • Lee, Jae-Woo;Kim, Chun-Hwey;Han, Won-yong;Jin, Ho;Oh, Kyu-Dong
    • Journal of Astronomy and Space Sciences
    • /
    • v.20 no.2
    • /
    • pp.123-132
    • /
    • 2003
  • We performed CCD photometric observations of the W-type contact binary AB And for 10 nights from November 1995 to December 1999 using the 61-cm reflector and BVR filters at Sobaeksan Optical Astronomy Observatory. From our observations, the seasonal light curves of AB And for 1995, 1996 and 1999 were completed and 8 new times of minimum light were determined. Newly obtained light curves show that strong light variations occurred in AB And during the past five years. We adopted the 1996 light curves as reference ones and obtained the photometric solutions of them with contact mode in the Wilson-Devinney binary code. Assuming such light variations were produced by the existence of a star spot (or star spots) in the analysis, we derived the system parameters and analyzed the 1995 and 1999 light curves by adjusting only the spot parameters. As the results, we interpreted that those light variations are produced by the simultaneous existence of a hot spot and a cool spot on the secondary. We could infer that the hot spot on the secondary is produced due to mass exchange between the components suggested by Lee (1999).

Investigation of Bacterial Contamination of Liquid Soaps Used in Public Restroom (공공 화장실에서 사용하는 액체 손세정제의 세균 오염도 조사)

  • Hong, Seung Bok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.3
    • /
    • pp.214-220
    • /
    • 2020
  • Handwashing with soap is an important practice to reduce the transmission of potentially pathogenic microorganisms, but liquid soaps with refillable dispensers are prone to extrinsic bacterial contamination. This study investigated the bacterial contamination of liquid soaps in 58 public restrooms in six buildings. The bacteria were identified by a biochemical test and MALDI-TOF mass spectrophotometry. The antimicrobial susceptibility was determined using the Vitek II system. Of the 58 restrooms examined, 27(46.55%) were using a refill dispenser, of which 25(92.59%) were contaminated with bacteria. The bacteria recovered from the soaps ranged from 1.6×103 to 2.7×105 CFU/mL. Serratia liquefaciens (12), Achromobacter xylosoxidans (9), S. marcescens (4), Staphylococcus pastueri (1), and Achromobacter spanius (1) were isolated. Except for one A. xylosoxidans, bacteria of the same species isolated in the same building showed a unique resistance pattern. In conclusion, handwashing with contaminated soap may play a role in the transmission of bacteria in public health settings. Therefore, it is necessary to limit the use of refillable liquid soaps in the restrooms of hospitals used by patients with reduced immunity.